• 제목/요약/키워드: 10 injection

검색결과 8,281건 처리시간 0.07초

Hole drilling angle이 가솔린 직접 분사식 인젝터의 내부 유동에 미치는 영향 (Effects of Hole Drilling Angle on Internal Flow of Gasoline Direct Injection Injector)

  • 김휘준;박성욱
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.197-203
    • /
    • 2021
  • In gasoline direct injection injectors, cavitation can be generated inside the hole because of their high injection pressure. In this paper, the effects of cavitation development in injector were investigated depending on the various hole drilling angles were investigated by a numerical method. In order to verify the internal flow model, injection rate and injection quantity of individual holes were measured. The BOSCH long tube method was used to measure the injection rate. As a result, even if the hole diameters were the same, the discharge coefficient differed by up to 10% depending on the hole angle. Moreover, if the hole drilling angle became greater than 30°, the area coefficient and the discharge coefficient decreased as the nozzle outlet was blocked due to cavitation.

기액분리기를 적용한 가스 인젝션 히트펌프의 성능 향상에 관한 실험적 연구 (The Performance Improvement of a Gas Injection Heat Pump with a Flash Tank)

  • 손길수;김동우;최성경;김용찬
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.297-305
    • /
    • 2017
  • Air-source heat pumps are widely used in residential heating systems. However, the decrease in the capacity of the heat pump is unavoidable when operating at very low and high ambient temperatures. The vapor injection technique is considered a promising technology to overcome this problem. Recent research on vapor injection cycles have mainly adopted a scroll compressor with an internal heat exchanger at severe operating conditions. This study measured the COP and EER of a gas injection heat pump using a flash tank with an inverter-driven rotary compressor at severe operating conditions. Compared to non-injection heat pumps, the heating capacity and COP of the gas injection heat pump improved up to 15% and 2.9%, respectively, at outdoor temperatures of $-10^{\circ}C$ to $7^{\circ}C$. The cooling capacity of the gas injection heat pump was 11% higher than the non-injection heat pump at an outdoor temperature of $35^{\circ}C$. At the same time, the EER of the gas injection heat pump was similar to that of the non-injection heat pump.

디젤오염토양의 Bench Scale 처리에 있어서 벤팅모드 비교 (Comparison of Venting Modes for Bench Scale Treatment of Diesel Contaminated Soil)

  • 김영암;이용희;이동선;서명교
    • 한국환경보건학회지
    • /
    • 제32권5호
    • /
    • pp.499-505
    • /
    • 2006
  • Bioventing efficiency was compared in a continuous and an intermittent(6hr injection and 6hr rest) air injection mode. Two lab-scale columns which packed with 5 kg of soil artificially contaminated by diesel oil were operated. The columns were maintained at the $25^{\circ}C{\pm}2.5$ in order to minimize the effect of exterior temperature variation. The flow rate of air injection mode were maintained constantly at the flow rate of 10 ml/min. The moisture of the columns was stably maintained at $60{\sim}80%$ of field capacity. The nutrient compounds were added to make C:N:P ratio as 100:10:l. The continuous and intermittent injection modes showed 67.56% and 69.63% reduction of initial TPH concentration during 90 days, respectively. Two venting modes showed similar results in the analysis of the trends of the hydrocarbon utilizing bacterial counts for operating periods. The carbon dioxide production rate of the continuous injection mode was higher than that of intermittent injection mode. The loss of diesel oil by volatilization in the continuous and intermittent injection modes were about 5% and 1%, respectively. The lower volatilization loss in the intermittent injection mode suggested that the biodegradation of TPH in the intermittent injection mode was greater than that of the continuous mode. These results suggested that the intermittent injection mode is more efficient than the continuous venting mode.

Minimize Web Applications Vulnerabilities through the Early Detection of CRLF Injection

  • Md. Mijanur Rahman;Md. Asibul Hasan
    • International Journal of Computer Science & Network Security
    • /
    • 제23권2호
    • /
    • pp.199-202
    • /
    • 2023
  • Carriage return (CR) and line feed (LF), also known as CRLF injection is a type of vulnerability that allows a hacker to enter special characters into a web application, altering its operation or confusing the administrator. Log poisoning and HTTP response splitting are two prominent harmful uses of this technique. Additionally, CRLF injection can be used by an attacker to exploit other vulnerabilities, such as cross-site scripting (XSS). Email injection, also known as email header injection, is another way that can be used to modify the behavior of emails. The Open Web Application Security Project (OWASP) is an organization that studies vulnerabilities and ranks them based on their level of risk. According to OWASP, CRLF vulnerabilities are among the top 10 vulnerabilities and are a type of injection attack. Automated testing can help to quickly identify CRLF vulnerabilities, and is particularly useful for companies to test their applications before releasing them. However, CRLF vulnerabilities can also lead to the discovery of other high-risk vulnerabilities, and it fosters a better approach to mitigate CRLF vulnerabilities in the early stage and help secure applications against known vulnerabilities. Although there has been a significant amount of research on other types of injection attacks, such as Structure Query Language Injection (SQL Injection). There has been less research on CRLF vulnerabilities and how to detect them with automated testing. There is room for further research to be done on this subject matter in order to develop creative solutions to problems. It will also help to reduce false positive alerts by checking the header response of each request. Security automation is an important issue for companies trying to protect themselves against security threats. Automated alerts from security systems can provide a quicker and more accurate understanding of potential vulnerabilities and can help to reduce false positive alerts. Despite the extensive research on various types of vulnerabilities in web applications, CRLF vulnerabilities have only recently been included in the research. Utilizing automated testing as a recurring task can assist companies in receiving consistent updates about their systems and enhance their security.

Morphine 정주를 이용한 술후 통증 조절시 진토제 일회 정주의 지속적 항오심 및 항구토 효과 (Continuous Antiemetic Effects of Single Intravenous Injection of Antiemetics during Postoperative Pain Control with Morphine)

  • 최기선;안치홍;박성식;임동건;백운이;박진웅
    • The Korean Journal of Pain
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 1997
  • Background : This study was designed to evaluate the continuous effects of single intravenous injection of antiemetics on nausea and vomiting during continuous morphine injection for postoperative pain control. Methods : Prior to the study, we divided patients into two major groups according to the type of surgery performed intra-abdominal(Open: O) and non intra-abdominal(Close: C). When patients regained orientation after routine general anesthesia, enflurane-$O_2-N_2O$, we injected bolus dose of morphine and started continuous injection of morphine for postoperative pain control(Group I; Control). After bolus injection and just before continuous injection, we injected single dose of droperidol(Group II) or ondansetron(Group III). Mean arterial blood pressure, heart rate, pain score and symptom-therapy score were checked at 10 minutes, 4, 8, 16, 24, 36 hours after continuous morphine injection. Results : The pain score of group III was lower than group II(10 min.) and group I(24, 36 hours) in the open group. Symptom-therapy score of group III(10 min., 4, 24 hours) and group II(10 min.) were lower than group I in the open group. In the close group, symptom-therapy score of group III(8 hours) was lower than group I. Conclusions : Single intravenous injection of antiemetics have a tendency of lowering symptom-therapy score for 36 hours in spite of their relatively short elimination half-life.

  • PDF

포항분지 해상 CO2 주입정 시추 완결 및 구축 (Drilling and Completion of CO2 Injection Well in the Offshore Pohang Basin, Yeongil Bay)

  • 원경식;이대성;김상준;최성도
    • 지질공학
    • /
    • 제28권2호
    • /
    • pp.193-206
    • /
    • 2018
  • 본 연구는 "포항분지 해상 소규모 $CO_2$ 주입실증 프로젝트"의 일환으로 경상북도 포항시 영일만에 설치된 해상 플랫폼에서 $CO_2$ 주입 실증을 위한 주입정 시추 및 완결(well drilling and completion)을 수행하였다. 주입정 시추(well drilling)는 포항분지 해상지역 퇴적지층에 설치한 해상플랫폼의 상부부터 해저면까지 케이싱 설치를 시작으로 단계별로 굴진 공경을 축소하면서 케이싱 설치 및 시멘트 그라우팅(cement grouting)을 시행하며 진행하였다. 최종심도 816.5 m 까지 공경 4 7/8 inch (${\Phi}124mm$) 규격으로 굴진하여 심도 746.5~816.5 m 구간에 유공 케이싱을 설치하여 주입구간을 형성하였다. $CO_2$ 주입을 위한 주입공 완결(well completion)을 위하여 주입관, 패커(packer), 주입탑(christmas tree)을 설치하였다. 주입공을 완결하고 주입 플랜트 설비를 설치하여 $CO_2$ 시험 주입을 성공적으로 수행하였다. 현재의 주입설비는 100톤 규모의 소규모 주입 실증을 위한 설비로서 향후 주입설비 격상을 통하여 총 1만톤의 중규모 실증 주입설비로 추가적인 연구개발을 진행하고 있다.

역방향스월자기주입 시일의 누설 성능에 관한 실험 연구 (Test Results of Leakage Performance for Anti-Swirl Self-Injection Seals)

  • 김창호;이용복
    • Tribology and Lubricants
    • /
    • 제7권2호
    • /
    • pp.41-45
    • /
    • 1991
  • An experimental investigation for leakage performance of five anti-swirl self-injection seals was carried out to select an optimum configuration for minimum leakage. Test results show that the self-injection mechanism with a plain seal generally degrades the leakage performance of noncontacting seals; however, through a series of the test program, an optimum anti-swirl self injection seal was selected to obtain a comparable leakage performance with a damper seal. A 12 holes anti-swirl and anti-leakage self-injected. configuration with a labyrinth surface gives minimum leakage among the tested anti-swirl self-injection seals.

분사압력변화가 분무특성에 미치는 영향에 관한 수치적 고찰 (Numerical Analysis of the Effect of Injection Pressure Variation on Spray Characteristics)

  • 박권하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.113-119
    • /
    • 1997
  • This paper addresses to the injection pressure effect on the diesel spray. The injection pressure is varied from 10MPa, in general system, upto 200MPa, in high pressured system in order to understand the effect. The gas phase is modelled in terms of the Eulerian continuum conservation equations of mass, momentum, energy and fuel vapour fraction. The liquid phase is modelled following the discrete droplet model approach in Lagrangian form. The droplet distributions, vapor fractions and gas flows are analyzed in various injection pressure cases.

  • PDF

사출압축성형 공정에 대한 유한요소 해석 (Finite Element Analysis of Injection/Compression Molding Process)

  • 이호상
    • 소성∙가공
    • /
    • 제13권2호
    • /
    • pp.180-187
    • /
    • 2004
  • A computer code was developed to simulate the filling stage of the injection/compression molding process by a finite element method. The constitutive equation used here was the compressible Leonov model. The PVT relationship was assumed to follow the Tait equation. The flow-induced birefringence was related to the calculated flow stresses through the linear stress-optical law. Simulations of a disk part under different process conditions including the variation of compression stroke and compression speed were carried out to understand their effects on birefringence variation. The simulated results were also compared with those by conventional injection molding.

실명한 절대 녹내장견에 대한 겐타마이신 초자체내 주사: 13두 (Intravitreal Gentamicin Injection in the Absolute and Blind Glaucoma Dogs: 13 Cases)

  • 김완희;강선미;권오경
    • 한국임상수의학회지
    • /
    • 제19권4호
    • /
    • pp.461-463
    • /
    • 2002
  • Pharmacological ablation of the ciliary body by intravitreal injection of a cytotoxic dose of gentamicin was utilized for the treatment of absolute glaucoma in 13 dogs. Complications of this procedure were hyphema(2), corneal opacity(2), iris bombe(1), cataract(1) and chronic inflammation(1). Injection time was one time in 10 dogs, two times in 2 dogs and 3 times in a dog. Intravitreal injection of gentamicin was thought as a economic salvage procedure and has resulted in successful lowering of intraocular pressure.