• Title/Summary/Keyword: 10 MV X-ray

Search Result 205, Processing Time 0.028 seconds

The Prognostic Factors Affecting Survival in Muscle Invasive Bladder Cancer Treated with Radiotherapy (방사선치료를 받은 근 침윤성 방광암의 예후 인자)

  • Chung Woong-Ki;Oh Bong-Ryoul;Ahn Sung Ja;Nah Byung Sik;Kwon Dong-Deuk;Park Kwangsung;Ryu Soo-Bang;Park Yang-IL
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.130-138
    • /
    • 2002
  • Purpose : This study analyzed the prognostic factors affecting the survival rate and evaluated the role of radiation therapy in muscle-invading bladder cancer. Materials and Methods : Twenty eight patients with bladder cancer who completed planned definitive radiotherapy in the Departments of Therapeutic Radiology and Urology, Chonnam National University Hospital between Jan. 1986 to Dec. 1998 were retrospectively analyzed. The reviews were peformed based on the patients' medical records. There were 21 males and 7 females in this study. The median of age was 72 years old ranging from 49 to 84 years. All patients were confirmed as having transitional cell carcinoma with histological grade 1 in one patient, grade 2 in 15, grade 3 in 9, and uninformed in 3. Radiation therapy was peformed using a linear accelerator with 6 or 10 MV X-rays. Radiation was delivered daily with a 1.8 or 2.0 Gy fraction size by 4 ports (anterior-posterior, both lateral, alternatively) or 3 ports (Anterior and both lateral). The median radiation dose delivered to the isocenter of the target volume was 61.24 Gy ranging from 59 to 66.6 Gy. The survival rate was calculated by the Kaplan-Meier method. Multivariate analysis was peformed on the prognostic factors affecting the survival rate. Results : The survival rate was $76\%,\;46\%,\;33\%,\;33\%$ at 1, 2, 3, 5 years, respectively, with 19 months of median survival. The potential factors of age (less than 70 years vs above 70), sex, diabetes mellitus, hypertension, hydronephrosis, 1-stage (T3a vs T3b), TUR, chemotherapy, total duration of radiotherapy, radiation dose (less than 60 Gy vs above 60 Gy), and the treatment response were investigated with uniand multivariate analysis. Un univariate analysis, the T-stage (p=0.078) and radiation dose (p=0.051) were marginally significant, and the treatment response (p=0.011) was a statistically significant factor on the survival rate. Multivariate analysis showed there were no significant prognostic factors affecting the survival rate. Conclusion : The treatment response and radiation dose are suggested as th은 statistically significant factors affecting the survival rate of muscle invasive bladder cancer. A Further prospective randomized study is needed to confirm these prognostic factors.

Results of Concurrent Chemoradiotherapy and Intraluminal Brachytherapy in Esophageal Carcinoma - Retrospective Analysis with Respect to Survival - (식도암에서 동시 항암화학방사선요법과 관내근접치료의 결과 -생존율을 중심으로 한 후향적 분석-)

  • Nam Taek-Keun;Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Song Ju-Young
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • Purpose : Evaluate the efficacies and toxicities of concurrent chemoradiotherapy (CCRT), with or without intraluminal brachytherapy (ILB), using a retrospective analysis in esophageal carcinomas with respect to survival. Materials and Methods : From April 1995 to July 2001, a total of 65 patients, diagnosed with an esophageal carcinoma, were treated by CCRT, with 21 also treated by ILB after CCRT. External radiotherapy was peformed using 6 or 10 MV X-rays, with a dose range of $46.8~\69.6$ Gy (median; 59.4). The ILB was peformed using high-dose-rate brachytherapy with Ir-192. The fractionation of ILB was 3 Gy by 4, or 5 Gy by 2 fractions. Cisplatin $(75\;mg/m^2)$ was given on each first day of weeks 1, 5, 9 and 13, and 5-FU $(1,000\;mg/m^2)$ as a continuous infusion for the first 4 days of each course. Results : The median survival time of all patients was 15 months, and the 1, 2 and 3-year survival rates were 55.4, 29.2 and $20.7\%$, respectively. The 2-year survival rates of the patients with and without ILB were 33.3 and $27.3\%$, respectively (p=0.80). The 2-year survival rates of the patients with a complete, partial and no response were 44.1, 13.8 and $0\%$, respectively (p=0.02). The response to treatment was the only significant factor affecting the overall survival from a multivariate analysis. Conclusion : This study has shown that the survival outcomes of CCRT were much better than previous results with radiotherapy alone. However, the addition of ILB after CCRT showed no advantage over that of CCRT alone.

Study on Development of Acute Index Through Peripheral Blood Test in Total Body Irradiation Patients (방사선 전신조사 환자의 말초혈액 검사를 통한 급성장애 지표개발에 관한 연구)

  • Park, Young-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.91-103
    • /
    • 2001
  • In those patients who underwent radiation therapy with 10 MV X-ray for bone marrow transfer, compared the effect of high dose irradiation on peripheral blood were investigated in randomly selecting 18 patients. thus, changes in the levels of peripheral blood (WBC, Seg. neutrophil, Lymphocyte, RBC, Hemoglobin, Hematocrit ratio, GOT, GPT) were observed for 25 days after irradiation with the peripheral blood levels before irradiation in these patients and in 32 controls. Among changes in peripheral blood, the level of WBC was $8.63\%$ after radiation therapy with as much decrease as $0.22{\times}103{\pm}0.19{\times}103/mm^3$ compared with $2.51{\times}103{\pm}1.29{\times}103/mm^3$ before radiation therapy, and was only $6.35\%$ of $7.17{\times}103/mm^3{\pm}1.46{\times}103/mm^3$ in the controls, showing statistical significance (P<0.01, r2=0.9151). In the morphologic test of WBC, the level of Seg. neutrophil was decreased as much as to $20.53\%$ with $14.17{\pm}21.60\%$ compared with $69.00{\pm}25.60\%$ before irradiation, and decreased down to $24.39\%$ compared with $58.09{\pm}7.62\%$ in the controls (P<0.05, r2=0.6316). The number of lymphocyte increased as much as 3.94 folds at $79.91{\pm}27.30\%$ compared with $20.29{\pm}21.15\%$ before irradiation and was 2.39 times higher than $33.46{\pm}6.79\%$ in the controls (P<0.05, r2=0.7337). Although the change in the number of RBC was little with $3.18{\times}106{\pm}0.41{\times}106/mm^3$ before irradiation and $4.66{\times}106{\pm}0.43{\times}106/mm^3$ in the controls, no statistical significance was present (P>0.05). In addition, The number of hemoglobin was low compared with before irradiation and with the controls, but none showed statistical significance (P>0.05). Similarly, although the hematocrit ratio was low compared with before irradiation and with the controls, no statistical significance was present (P>0.05). In the values of the histologic examinations GOT and GPT, there is statistical significance between those from with before irradiation and with the controls (P<0.05). Thus, among peripheral blood, the number of WBC decreased drastically for a certain period after total body irradiation with high dose radiation, and the levels of Seg. neutriphil and lymphocyte decreased significantly after irradiation in the lymphocyte morphologic test. The results of the present study suggest that the possibility of developing the first to determine initially those patients who might develop radiation acute impairment using the usual peripheral blood test of patients to be exposed to high dose irradiation.

  • PDF

Radiotherapy Results of Midline Malignant Reticulosis (MMR) (중심선 악성 세망증의 방사선 치료 결과)

  • Yun, Sang-Mo;Kim, Jae-Cheol
    • Radiation Oncology Journal
    • /
    • v.14 no.4
    • /
    • pp.291-297
    • /
    • 1996
  • Purpose : This study was performed to evaluate survival, failure patterns, and prognostic factors of MMR patients after radiation therapy. We also discussed the need for chemotherapy. Materials and Methods : A retrospective analysis was done for 23 patients with MMR who were treated with radiation therapy from June 1985 to November 1992. There were 19 male and 4 female patients, The patients' age ranged from 17 to 71 years (median 39 years). Systemic symptoms including fever, weight loss, or malaise were found in $30\%$ of the patients. The nasal cavity was most frequently involved No patients had nodal involvement at diagnosis. There were 2 patients with distant metastasis at presentation. Radiation therapy was delivered five times a week, 1.8 Gy daily, total $45\~54$ Gy (median 50.4 Gy) using 6 MV X-ray No patients received chemotherapy as initial treatment. Results : Overall 5-year and 10-year survival rates were $52.4\%$ and $44.1\%$, respectively. Seventy Percent(12/17) of the patients achieved complete response to radiotherapy, and $29.4\%$ (5/17) achieved partial response. The Patients with complete response showed a better 5-year survival rate than those with partial response ($66.9\%$ vs. $20\%$. p=0.004). Symptom duration before diagnosis, the presence of systemic symptom, and the number of primary sites had no influence on survival. The patterns of failure were as follows: local failure(1), failure in adjacent site(1), local and distant failure(1) distant metastasis(2). and conversion to malignant lymphoma(1). We could not find factors associated with the patterns of failure. Conclusion : The most important facto associated with survival was the response to radiotherapy. Seventeen percent of the patients had distant metastasis, and the salvage after distant metastasis was not successful. However. about $50\%$ of the patients could achieve long-term survival with local radiation therapy alone. Therefore, chemotherapy of MMR should be done after a prospective randomized study for the factors associated with distant metastasis.

  • PDF

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

Radiotherapy Result of the Carcinoma of Uterine Cervix (자궁경부암의 방사선치료성적)

  • Park, Charn-Il;Ha, Sung-Whan;Kang, Soon-Beom;Lee, Hyo-Pyo;Shin, Myon-Woo
    • Radiation Oncology Journal
    • /
    • v.2 no.1
    • /
    • pp.107-113
    • /
    • 1984
  • One hundred sixty one patients with the carcinoma of uterine cervix received curative radiotherapy at the Department of Therapeutic Radiology, Seoul National University Hospital between December, 1979 and December, 1982. According to FIGO classification; stage $I_a 1(0.6\%)\;1_b\;8(5.0\%),\;II_a\;31(19.3\%),\;II_b\;66(41.0\%),\;III_a\;3(1.8\;%),\;III_b\;46(28.6\%)\;and\;IV_a\;6(3.7\;%)$. The proportion of early stage cancer is too small because most of them treated by surgery. External beam whole pelvic irradiation was done first with 10MV x-ray or Co-60 gamma ray upto 4,000 or 5,000 rad for early and advanced cases, followed by one or two courses of intracavitary radiation using Fletcher-Suit Applicator loading c Cs-137. Supplementary external radiation to pelvic side wall to bring dose to 6,000 or 6,500 rads, if there is parametrial involvement or positive pelvic lymph node. Of the 161 Patients, 49 Patients were lost to follow-up but only 22 patients were lost in disease free state. And so, 86.3 percent of the patients were followed to time of recurrence or to date. The results are as follows ; 1. Locoregional control rates according to stage is: stage I $100\%,\;II_a\;90.3\;%,\;II_b\;75.8\%,\;III_a\;66.7\%,\;III_b\;58.7\%\;and\;IV_a\;16.7\%$, respectively. 2. Persistent or recurrent disease were localized in pelvic cavity in 32 of 50 patients and 6 had distant metastasis only. 3. Rectal bleeding was the most common complication and appeared mostly between 6 and 24 months after radiotherapy. Most of them had transient minor bleeding and only 2 patients needed transfusion and 1 patient needed colostomy due to rectovaginal fistula. 4. The 3 year disease free survival rate is: stage I $100\%,\;II_a\;78.0\%,\;II_b\;60.6\%,\;III_a\;66.7\;III_b\;46.3\%\;and\;IN_a\;16.7\%$, respectively.

  • PDF

Film Dosimetry for Intensity Modulated Radiation Therapy : Dosimetric Evaluation (필름을 사용한 세기변조치료법에 대한 선량측정)

  • Ju Sang Gyu;Yeo Inhwan Jason;Huh Seung Jae;Choi Byung Ki;Park Young Hwan;Ahn Yong Chan;Kim Dae Yong;Kong Young Kun
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.172-178
    • /
    • 2002
  • Purpose : X-ray film over responds to low-energy photons in relative photon beam dosimetry because its sensor is based on silver bromide crystals, which are high-Z molecules. This over-response becomes a significant problem in clinical photon beam dosimetry particularly in regions outside the penumbra. In intensity modulated radiation therapy (IMRT), the radiation field is characterized by multiple small fields and their outside-penumbra regions. Therefore, in order to use film dosimetry for IMRT, the nature the source of the over-response in its radiation field need to be known. This study is aimed to verify and possibly improve film dosimetry for IMRT. Materials and Method : Modulated beams were constructed by a combination of five or seven different static radiation fields using 6 MeV X-rays. In order to verify film dosimetry, we used X-ray film and an ion chamber were used to measure the dose profiles at various depths in a phantom. In addition, in order to reduce the over-response, 0.01 inch thick lead filters were placed on both sides of the film. Results : The measured dose profiles showed a film over-response at the outside-penumbra and low dose regions. The error increased with depths and approached 15% at a maximum for the field size of $15{\times}15cm^2$ at 10 cm depth. The use of filters reduced the error to 3%, but caused an under-response of the dose in a perpendicular set-up. Conclusion : This study demonstrated that film dosimetry for IMRT involves sources of error due to its over-response to low-energy Photons. The use of filers can enhance the accuracy in film dosimetry for IMRT. In this regard, the use of optimal filter conditions is recommended.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer (자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향)

  • Kang, Min-Kyu;Huh, Seung-Jae;Han, Young-Yih;Park, Won;Ju, Sang-Gyu;Kim, Kyoung-Ju;Lee, Jeung-Eun;Park, Young-Je;Nam, Hee-Rim;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.130-137
    • /
    • 2004
  • Purpose : In radiotherapy for cervix cancer, both 3-dimensioal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) could reduce the dose to the small bowel (SB), while the small bowel displacement system (SBDS) could reduce the SB volume in the pelvic cavity. To evaluate the effect of the SBDS on the dose to the SB in 3D-CRT and IMRT plans, 3D-CRT and IMRT plans, with or without SBDS, were compared. Materials and Methods : Ten consecutive uterine cervix cancer patients, receiving curative radiotherapy, were accrued. Ten pairs of computerized tomography (CT) scans were obtained in the prone position, with or without SBDS, which consisted of a Styrofoam compression device and an individualized custom-made abdominal immobilization device. Both 3D-CRT, using the 4-field box technique, and IMRT plans, with 7 portals of 15 MV X-ray, were generated for each CT image, and proscribed 50 Gy (25 fractions) to the isocenter. For the SB, the volume change due to the SBDS and the DVHs of the four different plans were analyzed using palled t-tests. Results : The SBDS significantly reduced the mean SB volume from 522 to 262 cm$^{3}$ (49.8$\%$ reduction). The SB volumes that received a dose of 10$\~$50 Gy were significantly reduced in 3D-CRT (65$\~$80$\%$ reduction) and IMRT plans (54$\~$67$\%$ reduction) using the SBDS. When the SB volumes that received 20$\~$50 Gy were compared between the 3D-CRT and IMRT plans, those of the IMRT without the SBDS were significantly less, by 6$\~$7$\%$, than those for the 3D-CRT without the SBDS, but the volume difference was less than 1$\%$ when using the SBDS. Conclusion : The SBDS reduced the radiation dose to the SB in both the 3D-CRT and IMRT plans, so could reduce the radiation injury of the SB.