• Title/Summary/Keyword: 1. Heart valve prosthesis

Search Result 88, Processing Time 0.029 seconds

Clinical Results of Aortic Valve Replacement (대동맥판 치환술의 임상 성적)

  • Na, Guk-Ju;O, Jeong-U;An, Byeong-Hui;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.152-157
    • /
    • 1997
  • From August 1986 until June 1995, single aortic valve replacement was performed in 65 patients at the Chonnam National University Hospital. worthy-eight were male and 17 were female patients, ranging from 19 to 68 years of age(median : 43 years). The causes of the valve lesions were rheumatic in 29 patients (44.6%), bicuspid aortic valve in 6 patients (6.2%), endocarditis in 6 patients(6.2%), unknown in others. Concomitant surgical procedures were performed in 10 patients : repair of congenital defect in 5, pericardiectomy in 1, coronary artery bypass grafting in 1, noncoronary sinus plication in 1, Valsalva sinus aneurysmectomy in 1, subaortic membrane resection in 1 Used valves were 51. Jude-Medical valve in 42, Duromedics valve in 22, Bjork-Shiley valve in 2, Carpentier-Edward valve in 1. There were 3 hospital deaths (4.6%), and 2 late deaths (3.2%). Follow-up was 95.2% complete. The 10-year acturlal survival rate was 85.3%. Postoperative complications were low cardiac utput in 8, arrythmia in 5, valve related hemolysis in 1, cerebral infarction in 1, and gastrointestinal bleeding in 2. Reoperation was performed in 4 for surgical bleeding, in 3 for paravalvular leak. The mean improvement in New York Heart Association functional class is from 2.79 $\pm$ 0.66 preoperatively to 1.25 $\pm$ 0.49 postoperatively(p < 0.001) The change of cardiothoracic ratio from preoperative to postoperative is 0.57 $\pm$ 0.06 to 0.54 $\pm$ 0.05 (p < 0.05). The left ventricular ejection fraction change is not significant perioperatively. There are no mechanical failures. This early and intermediate-term follow-up suggests that in adults in whom valve repair is not possible, the mechanical valve is a reliable and durable prosthesis with good hemodynamic function and a low rate of thromboembolic event.

  • PDF

Hemolytic Anemia due to Tiny Prosthetic Paravalvular Leakage (작은 인공판막주위 누출에 의한 용혈성 빈혈)

  • 문광덕;김대영
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.444-448
    • /
    • 1996
  • Hemolytic anemia due to tiny prosthetic paravalvular leakage is one of a complication of prosthetic valve replacement. Mild Hemolysls usually occurs after aortic valve replacement with mechanical valve but rarely occurs in mitral valve position especially in case of tissue valve. Cardiac valves fabricated from biologic material are associated with a reduced incidence of hemolytic anemia. Hemolysis was reported in patients with an lonescu-Shiley bovine pericardial xenograft prosthesis in the aortic position but not in the mitral site. A 41-year-old female patient was admitted due to sudden development dark colored urine. About 10 years ago the patient was underwent MVR (Mitral Valve Re lacement) with fTmm lonescu-Shiley valve due to MR (Mitral regurgitation). Echocardiographic examination showed mild degree of mitral regurgitation with valvular thickening. However, there was no definitive evidence of paravalvular leakage. The peripheral blood smear showed nomochromic normocytic anemia, but the hematologic and urinary examination revealed severe hemolytic evidence. Mitral valve replacement with St. Jude Medical valve (27mm) was done and intraoperatively, a tiny paravalvular leakage was found which was regarded as the point of hemolysis. The hemolytic evidence completely disappeared. We are reporting a case of severe hemolytic anemia due to tiny prosthetic paravalvular leakage with a review of the literature.

  • PDF

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

Long Term Outcomes of Aortic Root Replacement: 18 Years' Experience

  • Bang, Ji Hyun;Im, Yu-Mi;Kim, Joon Bum;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won;Jung, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.46 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • Background: We reviewed the long-term outcomes of aortic root replacement at Asan Medical Center and investigated the predictors affecting mortality. Materials and Methods: A retrospective analysis was performed on 225 consecutive adult patients undergoing aortic root replacement with mechanical conduits (n=169), porcine aortic root prosthesis (n=23), or aortic homografts (n=33) from January 1992 to September 2009. The median follow-up duration was 6.1 years (range, 0 to 18.0 years). Results: The porcine root group was older than the other groups (freestyle $55.9{\pm}14.3$ years vs. mechanical $46.3{\pm}14.6$ years, homograft $48.1{\pm}14.7$ years; p=0.02). The mechanical group had the highest incidence of the Marfan syndrome (mechanical 22%, freestyle 4%, homograft 3%; p=0.01). Surgery performed for infective endocarditis was more frequent in the homograft group (mechanical 10%, freestyle 10%, homograft 40%; p<0.001). The overall 30-day mortality was 5.3% (12/225). Actuarial survival rates in the mechanical, porcine root, and homograft groups were 79.4%, 81.5%, and 83.5% at 5 years and 67%, 61.9%, and 61.1% at 10 years, respectively (p=0.73). By multivariate analysis, preoperative diabetes mellitus, older age, and longer cardiopulmonary bypass time were independent predictors of mortality. Incidence of postoperative complications, including infective endocarditis and thromboembolism were comparable in all of the groups. Conclusion: Aortic root replacement can be safely performed with different types of prostheses as the outcome was not affected by the choice of prosthesis. Further studies are required to assess the long-term durability of biological prostheses.

Continuous "Over and Over" Suture for Tricuspid Ring Annuloplasty

  • Park, Kwon-Jae;Woo, Jong-Soo;Jeong, Sang-Seok;Yi, Jung-Hoon
    • Journal of Chest Surgery
    • /
    • v.45 no.1
    • /
    • pp.19-23
    • /
    • 2012
  • Background: A ring implantation in the tricuspid annulus requires many interrupted mattress sutures for correction of tricuspid regurgitation (TR). In this study, tricuspid ring annuloplasty was performed by 2-0 polypropylene continuous suture instead of multiple interrupted 2-0 polyester mattress sutures, and the efficacy of the method was evaluated. Materials and Methods: This study included 20 patients who underwent tricuspid ring annuloplasty by continuous suture between May 2009 and July 2010. Four of the patients had an isolated TR, and the rest had a left-sided cardiac lesion. The concomitant tricuspid annuloplasty was performed after the left-sided heart surgery was completed and a Duran flexible ring prosthesis was used. Results: There was no perioperative mortality or conduction problem. More than a moderate degree of TR was improved to less than a mild degree after the procedure. After the ring annuloplasty, the right atrial volume decreased from $123.7{\pm}69.2mL$ to $74.5{\pm}37.4mL$, and the mean right atrial pressure was lowered from $18.7{\pm}12.2mmHg$ to $8.9{\pm}5.5mmHg$. Conclusion: The continuous "over and over" suture may be a useful procedure for fixing the ring to the annulus and making an intentional annular placation in performing tricuspid ring annuloplasty.

Midterm Results of Aortic Valve Replacement Using Tissue Valve (조직판막을 이용한 대동맥판막치환술의 중기성적)

  • Moon, Duk-Hwan;Lee, Jae-Won;Kim, Yun-Seok;Cho, Won-Chul;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.627-634
    • /
    • 2010
  • Background: The durability of the tissue valve is important in choice between a mechanical valve and a tissue valve in cardiac surgery. We studied the mid-term results of tissue valve in the aortic position. Material and Method: The subjects were 380 patients who had undergone aortic prosthesis replacement between May 1990 and March 2009. We retrospectively analyzed hospital and outpatient records: the mean age was $69{\pm}9$ years; the male to female ratio was 227 : 162; and the mean follow-up duration was $46.7{\pm}40.8$ months (range 0~196 months). Result: 389 surgical cases in total had been taken with 380 patients. Early death occurred in 15 patients (3.9%). Overall survival rate at 1, 5 and 10 years were 92.3%, 78.1% and 54.2% respectively. Freedom from reoperation at 1, 5 and 10 years were 98.4%, 97.1% and 91.7% respectively. Freedom from structural valvular deterioration at 1, 5 and 10 years were 96.1%, 92.3% and 88.0% respectively. In the multivariate analysis of preoperative risk factors, young age (p<0.001) was significant risk factor for reoperation. High peak velocity in the postoperative period (p=0.034) and young age (p=0.029) were significant risk factors for structural valvular deterioration. Old age (p=0.001), long bypass time (p=0.035), concomitant coronary artery bypass graft surgery (p=0.003) and preoperative low left ventricular ejection fraction (p=0.003) were significant factors for early mortality. Preoperative estimated glomerular filtration rate (< 60 mL/min) (p=0.025) and persistent left ventricular hypertrophy (p=0.032) were the risk factors for late mortality. Conclusion: This study showed that the freedom from reoperation and the freedom from structural valvular deterioration in aortic tissue valve replacement were acceptable. It will be necessary to conduct further studies with long-term follow-up and more patients.

The change of QRS duration after pulmonary valve replacement in patients with repaired tetralogy of Fallot and pulmonary regurgitation

  • Yun, Yuni;Kim, Yeo Hyang;Kwon, Jung Eun
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.11
    • /
    • pp.362-365
    • /
    • 2018
  • Purpose: This study aimed to analyze changes in QRS duration and cardiothoracic ratio (CTR) following pulmonary valve replacement (PVR) in patients with tetralogy of Fallot (TOF). Methods: Children and adolescents who had previously undergone total repair for TOF (n=67; median age, 16 years) who required elective PVR for pulmonary regurgitation and/or right ventricular out tract obstruction were included in this study. The QRS duration and CTR were measured pre- and postoperatively and postoperative changes were evaluated. Results: Following PVR, the CTR significantly decreased (pre-PVR $57.2%{\pm}6.2%$, post-PVR $53.8%{\pm}5.5%$, P=0.002). The postoperative QRS duration showed a tendency to decrease (pre-PVR $162.7{\pm}26.4$ msec, post-PVR $156.4{\pm}24.4$ msec, P=0.124). QRS duration was greater than 180 msec in 6 patients prior to PVR. Of these, 5 patients showed a decrease in QRS duration following PVR; QRS duration was less than 180 msec in 2 patients, and QRS duration remained greater than 180 msec in 3 patients, including 2 patients with diffuse postoperative right ventricular outflow tract hypokinesis. Six patients had coexisting arrhythmias before PVR; 2 patients, atrial tachycardia; 3 patients, premature ventricular contraction; and 1 patient, premature atrial contraction. None of the patients presented with arrhythmia following PVR. Conclusion: The CTR and QRS duration reduced following PVR. However, QRS duration may not decrease below 180 msec after PVR, particularly in patients with right ventricular outflow tract hypokinesis. The CTR and ECG may provide additional clinical information on changes in right ventricular volume and/or pressure in these patients.

Long Term Results of Rastelli Operation with a Mechanical Valve (기계 판막을 이용한 라스텔리 수술의 장기 성적)

  • Choi, Se-Hoon;Kim, Kwan-Chang;Kwak, Jae-Gun;Kim, Chang-Young;Lee, Jeong-Ryul;Kim, Yong-Jin;Rho, Joon-Ryang;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.12 s.269
    • /
    • pp.900-905
    • /
    • 2006
  • Background: Homografts and bioprostheses are most commonly used for Rastelli operation in congenital heart disease, but the limited durability is responsible for multiple reoperations associated with increased morbidity This study evaluated long-term results after Rastelli operation with a mechanical valved conduit. Material and Method: A total of 20 patients underwent Rastelli operation with mechanical valved conduit from January 1990 to July 1992. Operative mortality was 1 of 20 patients, and a retrospective review of 19 patients(10 males, 9 females) was done. Initial diagnosis was congenitally corrected transposition of great arteries(cc-TGA, n=4), complete TGA (n=2), ventricular septal defect with pulmonary atresia(VSD with PA, n=9), truncus arteriosus(n=2), double outlet right ventricle with pulmonary stenosis(DORV with PS, n=2). The mean age at Rastelli operation was $4.6{\pm}3.4$ years, and mean follow-up period was $12.8{\pm}2.7$ years. Patients underwent Rastelli opearation using 16 CarboMedics mechanical valve, and 3 Bjork-Shiley mechanical valve($17{\pm}2$ mm). Result: There were 15 reoperations for failed mechanical valved conduit. The freedom from reoperation at 5 and 10 years was 53% and 37%. Most patients were received oral anticoagulation with warfarin, and maintained the international normalized ratio(INR) of 1.5 to 2.0. There was no anticoagulation or thromboembolism related complication. There was a significant difference in the causes of a conduit failure between early(within 3 years) and late(after 3 years) failure groups. The six patients reported early prosthetic valve failure, mainly due to valvular dysfunction by thrombosis or pannus formation. The other nine patients reported late prosthetic valve failure, mainly due to dacron conduit stenosis at anastomosis sites, whereas their valvar motion was normal except 1 patient. Conclusion: To avoid early prosthetic valve failure, strict anticoagulation therapy would be helpful. About the late development of obstructive intimal fibrocalcific peels within the Dacron conduit, an improvement of conduit material is necessary to reduce late prosthetic valve failure. In selected patients, the long term results were satisfactory.

Opelative Risk and Results of Reoporation for Heart Valve Prostheses (인공심장판막 재치환술에 대한 수술 위험 인자 및 결과)

  • 김철환;김경훈
    • Journal of Chest Surgery
    • /
    • v.30 no.10
    • /
    • pp.973-978
    • /
    • 1997
  • We reviewed data of 64 patients who underwent reoperation because of prosthetic valve malfunction from January 1991 to December 1995. The indications for reoperation were prosthetic valve failure(primary tissue failure: 53 patients, 82.8%), prosthetic valve thrombosis(6 patients, 9.4%), paravalvular leak(3 patients, 4.7%), prosthetic valve endocarditis(2 patients, 3.6%). Prosthetic valve failure developed most frequently in mitral portion(40 patients, 75%), prosthetic valve thrombosis also in mitral portion(4 patients, 67%), paravalvular leak significantly in aortic portio (3 patients, 100%). Explant period was longest in prosthetic valve failure(mean 107.4 $\pm$ 24.6 months), shortest in prosthetic valve endocarditis with prosthetic valve thrombosis(1 patient, 1 month). Mean explant period, defined as from first valve replacement operation to redo-valve replacement operatopn, was 109.2$\pm$ 10.7 months in mitral portion, 97.8$\pm$ 10.4 months in aortic portion, 109.5$\pm$ 10.4 months in total. Overall hospital mortality was 9.38%. The most common cause of death was the low cardiac output(4 patients), other causes were bleeding(1 patient), CNS injury(1 patient). Preoperative NYHA class IV(P=0.011), emergency operation(P=0.011), prosthetic valve endocarditis(P=0.001) were the independent risk factors, but age, sex, explant period, ACC time, double valve replacement, valve position, second reoperation did not appear to be significant risk factors. Mean follow up period was 28.8 $\pm$ 17.8 months. Actuarial survival at 3 year was 92.0$\pm$6.2%, 2 year event-free survival w s 84.3$\pm$6.1%. We propose that patients undergoing reoperation because of prosthetic valve failure are carfully controlled and selected in regarding to above mentioned risk factors NYHA class IV, emergency operation, prosthetic valve endocarditis in preoperative state. About other risk factors possible, there is necessary of following study.

  • PDF

Simple Interrupted Suturing for Aortic Valve Replacement in Patients with Severe Aortic Stenosis

  • Lee, Jun Oh;Lee, Chee-hoon;Kim, Ho Jin;Kim, Joon Bum;Jung, Sung-Ho;Joo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.332-338
    • /
    • 2020
  • Background: Attaining an adequate effective orifice area (EOA) is definitive goal in aortic valve replacement (AVR). The simple interrupted suture (SIS) technique could be a solution to achieve this goal, but limited data are available in the literature. This study aimed to compare hemodynamic differences between the SIS and non-everting mattress suture (NMS) techniques. Methods: From our database, 215 patients who underwent AVR for severe aortic stenosis were extracted to form the overall cohort. From March 2015 to November 2016, the SIS technique was used in 79 patients, while the NMS technique was used in 136 patients. Hemodynamic outcomes were evaluated, as detected by transthoracic echocardiography and computed tomography. Results: There were no significant differences in baseline characteristics between the 2 groups. On immediate postoperative echocardiography, the SIS group showed a significantly wider EOA (1.6±0.4 vs. 1.4±0.5 ㎠, p=0.007) and a lower mean pressure gradient (PG) (13.3±5.4 vs. 17.0±6.0 mm Hg, p<0.001) than the NMS group. On follow-up echocardiography, the SIS group continued to have a wider EOA (1.6±0.4 vs. 1.4±0.3 ㎠, p<0.001) and a lower mean PG (11.0±5.1 vs. 14.1±5.5 mm Hg, p<0.001). There was no significant difference in paravalvular leakage. Conclusion: The SIS technique for AVR was associated with a wider EOA and a lower mean PG. The SIS technique could be a reasonable option for AVR.