• Title/Summary/Keyword: 1-type curve

Search Result 793, Processing Time 0.029 seconds

A study on the Flood Frequency Analyzed in Consideration of Low Outliers. (Low Outliers를 고려한 홍수빈도분석에 관한 연구)

  • 이순혁;홍성표;박명근
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.4
    • /
    • pp.62-70
    • /
    • 1988
  • This study was conducted to solve the problems for the unsuitable parameters and the uncertainty of design flood can be appeared by low outliers were inclined to the lower part from the trend of the balance of the data. Derivation of reasonable design flood was attempted finally by modification of low outliers with analysis of flood frequency by means of Log Pearson Type Ill distribution. Three subwatersheds were selected as studying basins with the annual maximum series including low outliers along Geum River basin. The results through this study were analyzed and summarized as follows. 1. Log Pearson Type In distribution was confirmed as a reasonable one by X$^2$ goodness of fit test at Gong Ju, Gyu Am, og Cheon watershed along Geum River basin. 2. Probable flood flows for each watershed were derivated by flood frequency curve with outliers. 3. Weighted skew coefficient for each watershed was calculated for the evaluation of freq- uency factor which is needed for the modification of low outlier. 4. It was confirrned that adjusted frequency curve has a lower tendency than that of deletion of low outlier in common at all watersheds. 5. Final probable flood flows were derivated by modification with evaluation of modified basic statistics for three watersheds. 6. In comparison with a frequency curve with modification and one with outlier, The former has a higher probable flood flow within three years of return periods than that of the latter, and vice versa over three years of return periods.

  • PDF

Applicability Evaluation of PSC-U Type Girder and Precast Deck to the Vertical Curves in Urban Maglev Train Route (도심형 자기부상열차 선로 종곡선 구간에서의 PSC-U 형 거더와 프리캐스트 바닥판 적용성 평가)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Lee, Yun-Seok;Ma, Hyang-Wook;Oh, Hyun-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.24-30
    • /
    • 2008
  • One of the characteristics of the Maglev Train is the prominent capability of upgoing. Maglev train with the aim of longitudinal slope 7/100 is under development by the Center for Urban Maglev Program in Korea. To realize these slope, vertical curves must be inserted before and after the slope. The inserted curve has the radius of 3,000m generally. The insertion of these vertical curve results in the additional differences between the girder upper face and the guide rail, and the alignments are controlled by cast in place concrete at present. In this study, for longitudinal curved route with longitudinal slope 6/100, the applicability of PSC-U type girder and precast deck was evaluated for the span length 25m, 30m and vertical curve radii with 3,000m and 1,500m with respect to longitudinal slope 6/100.

  • PDF

Design and EM Analysis of Dual Band Hilbert Curve Based Wilkinson Power Divider

  • Kaur, Avneet;Singh, Harsimran;Malhotra, Jyoteesh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.5
    • /
    • pp.257-260
    • /
    • 2016
  • In this paper, two configurations (T-type and Y-type) of dual band Wilkinson Power Divider based upon Hilbert curves are presented. Formerly, the concept of Hilbert Curves was implemented in only designing microstrip antennas. In power dividers, this is the very first attempt of incorporating them for size reduction. In addition to this, an effect of inculcation of high-dielectric constant layer (Hafnium-oxide, HfO2, εr= 25) between a substrate and top metallization in both configurations was investigated. The proposed configurations are designed on a high resistive silicon substrate (HRS) for L and S bands with resonating frequencies of 1.575 and 3.4 GHz. Both configurations have return loss that is better than 20 dB and an insertion loss of around 6 dB; isolation better than 30 dB was achieved for both models.

A method of Determination of Fracture Toughness of Reactor Pressure Vessel Steel by J Integral (J적분을 이용한 원자력 압력용기강의 파괴인성치의 결정)

  • 오세욱;임만배;김진선
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.111-119
    • /
    • 1995
  • The elastic-plastic fracture toughness($J_{IC}$) and fracture resistance (J-R curve) of SA508-3 alloy steel used for nuclear reactor pressure vessel are investigated by using CT-type specimens. Fracture toughness tests are conducted by unloading compliance method and multiple specimen method at room temperature, -2$0^{\circ}C$ and 20$0^{\circ}C$. The apparent negative crack growth phenomenon which usually arises in partial unloading compliance test is well known. The negative crack growth phenomenon in determining J sub(IC) or J-R cure from partial unloading compliance experiments may be eliminated by the offset technique. In this study, the evaluation of $J_{IC}$ multiple specimen method recommended by the JSME gives the most reliable results by using half-size CT(similar-type) specimens.

  • PDF

The Dependence of Type Ia Supernova Luminosities on the Global and Local Properties of Host Galaxies in the YONSEI Supernova Catalog

  • Kim, Young-Lo;Kang, Yijung;Lee, Young-Wook
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.62.3-63
    • /
    • 2018
  • Trends of Type Ia supernova (SN Ia) luminosities with the properties of host galaxies are important to study the underlying physics for an SN progenitor system and explosion mechanism. In the YONSEI SN catalog, we have a sample of ~600 SN and host data in the wider redshift range, and two independent light-curve models, SALT2 and MLCS2k2. From this catalog, here we present that SNe Ia in low-mass, globally and locally star-forming environments are fainter than those in high-mass, globally and locally passive environments, after light-curve shape and color or extinction corrections. Our results are then compared to previous studies, and show consistent results.

  • PDF

The effects of circumstellar medium on Type Ic supernova light curve and color evolution and implications for LSQ14efd

  • Jin, Harim;Yoon, Sung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.64.3-64.3
    • /
    • 2019
  • A bright post-breakout emission was detected for a Type Ic supernova (SN Ic) LSQ14efd, which was among the first for SNe Ic. To explain the early-time light curve and color evolution, the effects of the circumstellar medium (CSM) are investigated. Four main parameters, CSM mass, CSM radius, nickel distribution, and explosion energy, are systematically explored in multi-group radiation hydrodynamics simulations, STELLA. Matching the model light curves and color evolution with the observation, we could constrain the parameter space and find out the best fit models. Our results imply that the progenitor suffered a strong mass loss shortly before the explosion and had a massive CSM of ~0.1 M.

  • PDF

PHOTOMETRIC SOLUTIONS OF W UMA TYPE STARS: GSC2576-0319 AND GSC2584-1731 (W UMa형 식쌍성 GSC2576-0319와 GSC2584-1731의 측광해)

  • Lee, Chung-Uk;Lee, Jae-Woo;Jin, Ho;Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.4
    • /
    • pp.311-318
    • /
    • 2006
  • High-precision photometric observations were performed in BVI bandpasses using Am robotic telescope at Mt. Lemmon Observatory for two binary stars, which are reclassified as W UMa-type systems from ROTSE(Robotic Optical Transient Search Experiment) follow-up observations and show peculiar light variations. In order to analyze W UMa-type eclipsing binaries systematically, the light curve analysis script using 2005 version of Wilson-Devinney binary code is constructed. The orbital inclinations of GSC2S84-1731 and GSC2576-0319 are $43.^{\circ}5\;and\;57.^{\circ}6$ from light-curve analysis, respectively. Spot model is applied to explain the asymmetric light curve for GSC2S84-1731 and the spot parameters are derived.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

Killing Rate Curve and Antivacterial Activity against Various Pathogenic Bacteria in the Presence of Enrofloxacin and Colistin (병원성미생물에 대한 Enrofloxacin과 Colistin의 배합비육에 따른 항균작용과 균의 사멸속도)

  • 윤효인;김민규;박승춘
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.215-222
    • /
    • 1997
  • Enrofloxacin-colistin combination, widely used in Gram negative infections in veterinary sector, was investigated in terms of MIC and initial killing rate using E coli k 88ab, Salmonella typhimurium, Pasteurella multocida type A, Bordetella bronchiseptica and Staphylococcus aureus as test organisms. On the basis of MICs of enrofloxacin-colistin combination against the above bacteria, killing rates of the combination of enrofloxacin and colistin at the ratio of 5:0, 4:1, 3:2, 1:1, 2:3, 1:4 and 0:5, indicated high and rapid antibacterial acitivities against all but Staphylococcus aureus R-209, with the number of bacteria reducing to less than one percent within two hours. At the MIC of enrofloxacin or colistin, both antibacterials showed the highest killing rates during 2-4 hours against Gram negatives such as E coli K88ab,Pasteurella multocida type A and Bodetella bronchiseptica but allowed the regrowth of the same pathogens thereafter. On the while, the combination of two antibacterials at a fourth MIC resulted in high killing rate without bacterial regrowth during 24 hours, suggesting the synergistic antivacterial effects. The combination, however, did not show favourable activity against Gram negatime S typhimurium and Gram positive S aureus ergistic antibacterial activity against Gram negatime pathogens but also colistin showed LPS-neutraization, we could suggest the combination should provide clinically positive therapeutic armarium in Gram negative infections.

  • PDF