• 제목/요약/키워드: 1-g shaking table model test

검색결과 51건 처리시간 0.024초

진동대 모형실험을 통한 보강토 옹벽의 거동 특성 (Behavior of Reinforced Earth Retaining Wall by Shaking Table Test)

  • 윤원섭;윤부열
    • 한국산업융합학회 논문집
    • /
    • 제22권6호
    • /
    • pp.637-647
    • /
    • 2019
  • In this study, we analyzed seismic behavior of reinforced earth retaining wall through the model test in order to characterize the behavior of reinforced earth retaining wall during earthquake. A scale model test was performed based on similitude ratio in accordance with law of similitude due to time and financial constraints on real scale modeling experiments. Seismic resistance characteristics of each seismic waves were analyzed by assessing the variations measured through excitation of the excited acceleration of 0.05g, 0.1g, 0.15g, and 0.2g. The results of this study, it would be important to obtain reasonable and abundant data on ground properties and seismic design in preparation for earthquakes when assessing the safety of block type reinforced earth retaining wall confined to model experiment. Acquisition of those data and systematic analytical techniques are considered likely to have a significant effect on the decrease of structure damage caused by earthquakes in Korea which has recently witnessed frequent occurrence of earthquakes.

진동대시험을 이용한 DCM공법에 따른 방파제의 동적거동 분석 (Analysis on the Dynamic Behavior of Breakwater with the DCM Method Using the Shaking Table Test)

  • 김영준;박인준
    • 한국지반환경공학회 논문집
    • /
    • 제23권5호
    • /
    • pp.25-32
    • /
    • 2022
  • 최근 우리나라에 리히터 규모 5.0 이상의 지진발생 2건과 규모가 낮은 지진발생이 많아짐에 따라 지진피해가 늘어나면서 내진설계에 대한 많은 연구와 관심이 높아지고 있으며, 그 중 최근 발생한 포항지진으로 인해 항만시설물에 대한 내진설계에도 관심이 높아졌다. 본 연구에서는 1g 진동대시험을 통하여 항만구조물 중 직립식, 경사식 방파제에 대한 지진 시 발생하는 동적거동에 대해서 실험 및 분석을 하였다. 이를 위해 사상법칙을 적용한 모델에 장주기(Hachinohe), 단주기(Ofunato), 인공지진파 총 세가지 지진파를 적용하고, 연약지반의 DCM 공법 보강 여부를 고려하여 실험하였다. 진동대시험결과를 기초로 지진 시 DCM 공법 보강 여부에 따라 직립식과 경사식 방파제의 동적거동에 대하여 가속도 및 수평·수직 변위를 분석하였다. 검토 결과 직립식 및 경사식 방파제 동적거동은 DCM 공법 보강을 한 경우에 지지력 및 강성이 높아짐에 따라 가속도의 증폭이 억제되는 경향을 나타내었다.

중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험 (Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame)

  • 이한선;우성우
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.241-252
    • /
    • 1998
  • 이 연구의목적은 여러 수준의 지진에 대한 비내진 상세를 가진 저층 모멘트 저항 골조의 실제 반응을 관찰하기 위한 것이다. 우선 모델에 대한 축소율은 사용된 진동대의 용량을 고려하여 1 : 5 로 결정하였으며 상사성의 법칙에 따라 모델을 제작하였다. 그 다음에 이 모델에 대해 Taft N21E 지진가속도 기록의 최대 지진가속도를 0.12g. 0.2g, 0.4g로 조정하여 진동대를 이용한 지진모의실험을 수행하였다. 각 층별 횡방향 가속도와 변위, 그리고 구조물의 취약부위에서 국부변형이 측정되었다. 밑면 전단력은 손수 만든 로드셀을 이용하여 측정하엿다. 각 지진모의실험 전과 후에는 고유주기와 감쇠비의 변화를 살펴보기 위해 자유진동실험을 수행하였다. 전체거동과 국부거동에 대한 실험결과를 분석한 결과, 이 모델은 우리나라의 현행 내진 설계 기준에서의 설계지진 즉, 0.12g의 최대 지진가속에 대해서는 선형탄성으로 거동하였다. 최대 밑면 전단력은 1.8tf 로 설계 밑면 전단력의 약 4.7배로나타났다.이 실험모델은 높은 수준의 지진모의실험에서도 양호한 성능을 나타내었다. 높은 수준의지진에 대한 저항의 주요요소는 1)높은 초과강도, 2)기본주기의 증가, 그리고 3)비탄성 변형에 의한 얼마간의 에너지소산이다. 이 실험에서 모델의 층간변위는 대략 허용한계 내에 있었다.

1g 진동대시험에서 사면의 위치에 따른 경계조건 영향평가 (Effects of Slope Location on the Boundary Condition in the 1g Shaking Table Test)

  • 정수근;김용;김대현
    • 지질공학
    • /
    • 제32권4호
    • /
    • pp.535-545
    • /
    • 2022
  • 내진설계에서 지반의 안정성을 향상시키기 위해서는 지진하중을 받는 지반의 동적거동을 이해하는 것이 필수적이다. 따라서 지반의 동적거동을 이해하는데 진동대 시험은 중요한 실험 중 하나이다. 이러한 진동대 시험에서 가장 중요한 인자 중 하나인 경계조건에 대한 영향성을 확인하고자 하였다. 본 연구의 목적은 지진하중에 의한 모형사면의 위치별 경계조건의 영향성을 확인하고자 한다. 연성토조(laminar shear box, LSB)안에 모형사면을 제작하여 위치에 따라 경계조건의 영향을 확인하였다. 토조 벽면으로부터 100, 50, 25 cm 지점에 각각의 모형사면을 조성하여 동일한 크기의 정현파 지진하중을 입력하였다. 그 결과, 모형사면에 대한 진동대 실험 시 25 cm 지점에 위치한 경우는 경계조건의 영향을 크게 받아 가속도가 증폭하는 모습을 확인할 수 있었으며 50~100 cm 지점에 위치한 경우 경계조건의 영향이 감소하여 적합한 위치로 판단되었다.

진동대 실험을 통한 암반비탈면의 변위 거동 특성 (Displacements Behavior of Rock Slope by Shaking Table Test)

  • 윤원섭;강종철;박연준
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.245-254
    • /
    • 2020
  • This study investigated the so far little-researched characteristics of the behaviors of rock slopes at the time of an earthquake. For the selection of the rock block, a proper model was formed by applying the similarity in consideration of the roughness and strength of the rock slope(10m) on the site, and shaking table tests were carried out according to seismic excitement acceleration, and seismic waves. In the case of the inclination angle of the joint plane of 20°, the long period wave at 0.3g or more at the time of the seismic excitement surpassed the length of 100mm, the permissible displacement (0.01H, H:slope height), which brought about the collapse of the rock; the short period wave surpassed the permissible displacement at 0.1g, which caused the collapse of the slope. The rock slope was close to a rigid block and a structure more vulnerable to the long period wave than to the short period wave. It collapsed in the short period wave even at the seismic amplitude smaller than the maximum design acceleration in Korea.

Comparison of numerical and analytical solutions for reinforced soil wall shaking table tests

  • Zarnani, Saman;El-Emam, Magdi M.;Bathurst, Richard J.
    • Geomechanics and Engineering
    • /
    • 제3권4호
    • /
    • pp.291-321
    • /
    • 2011
  • The paper describes a simple numerical FLAC model that was developed to simulate the dynamic response of two instrumented reduced-scale model reinforced soil walls constructed on a 1-g shaking table. The models were 1 m high by 1.4 m wide by 2.4 m long and were constructed with a uniform size sand backfill, a polymeric geogrid reinforcement material with appropriately scaled stiffness, and a structural full-height rigid panel facing. The wall toe was constructed to simulate a perfectly hinged toe (i.e. toe allowed to rotate only) in one model and an idealized sliding toe (i.e. toe allowed to rotate and slide horizontally) in the other. Physical and numerical models were subjected to the same stepped amplitude sinusoidal base acceleration record. The material properties of the component materials (e.g. backfill and reinforcement) were determined from independent laboratory testing (reinforcement) and by back-fitting results of a numerical FLAC model for direct shear box testing to the corresponding physical test results. A simple elastic-plastic model with Mohr-Coulomb failure criterion for the sand was judged to give satisfactory agreement with measured wall results. The numerical results are also compared to closed-form solutions for reinforcement loads. In most cases predicted and closed-form solutions fall within the accuracy of measured loads based on ${\pm}1$ standard deviation applied to physical measurements. The paper summarizes important lessons learned and implications to the seismic design and performance of geosynthetic reinforced soil walls.

상사법칙 검증을 위한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests for Similitude Laws)

  • 김성렬;황재익;김명모
    • 한국지반공학회논문집
    • /
    • 제22권5호
    • /
    • pp.59-67
    • /
    • 2006
  • 동일한 흙으로 조성된 모형지반에 대하여 1-g 모형실험과 원심모형실험을 수행하고 그 결과를 비교하였다. 원형지반은 10m 두께의 수평하고 느슨한 포화 사질토 지반으로 가정하였다. 1-g 모형실험은 1/20 축소모형, 원심모형실험은 1/40 축소모형을 이용하였다. 원심모형실험의 경우 점성유체를 사용하여 동적시간에 대한 상사비와 과잉간극수압소산시간에 대한 상사비가 동일하도록 하였다. 원심모형실험의 계측결과는 원형지반의 거동으로 가정하였다. 그리고, 1-g모형실험에 정상상태개념 및 두 가지 시간상사비 등을 적용하여 원형지반의 거동을 모사하고자 하였다. 동일한 위치에서의 과잉간극수압, 지반가속도 그리고 지표 침하량 등을 계측하여 비교하였다. 실험결과 지반의 투수계수가 작아서 진동 중 과잉간극수압 소산의 영향이 작고, 소산시간상사비를 적절하게 결정하면 1-g 모형실험으로부터 원형지반의 과잉간극수압 거동을 모사할 수 있는 것으로 나타났다.

진동대 실험을 통한 흙막이 벽체의 변위 거동 특성 (Displacements Behavior of Retaining Walls by Shaking Table Test)

  • 윤원섭;윤부열;양철규;박연준
    • 한국산업융합학회 논문집
    • /
    • 제21권6호
    • /
    • pp.409-418
    • /
    • 2018
  • In this study, experiments were carried out after fabricating and installing a physical model considering the size of the prototype. In the model test, the number of struts placed on the wall and the applied acceleration were selected as test variables. Two different types of waves, long-period and short-period, were applied with magnitudes of 0.05g, 0.1g, 0.2g, and 0.3g. Measured are displacements at specified points. As a result of the analysis, displacement exceeding the allowable displacement of the wall occurred at an acceleration greater than 0.05g to 0.1g depending on the seismic waves applied. Therefore guidelines have to be established through further studies for aseismic design of earth retaining walls.

진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가 (Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test)

  • 하익수;김용성;서민우;박동순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

액상화 지반에 대한 1-g 모형실험과 원심모형실험의 비교 연구 (Comparison of 1-g and Centrifuge Model Tests on Liquefied Sand Grounds)

  • 김성렬;황재익;;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.97-104
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.

  • PDF