• Title/Summary/Keyword: 1-D simulation

Search Result 3,645, Processing Time 0.04 seconds

Feature Extraction Algorithm for Distant Unmmaned Aerial Vehicle Detection (원거리 무인기 신호 식별을 위한 특징추출 알고리즘)

  • Kim, Juho;Lee, Kibae;Bae, Jinho;Lee, Chong Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.114-123
    • /
    • 2016
  • The effective feature extraction method for unmanned aerial vehicle (UAV) detection is proposed and verified in this paper. The UAV engine sound is harmonic complex tone whose frequency ratio is integer and its variation is continuous in time. Using these characteristic, we propose the feature vector composed of a mean and standard deviation of difference value between fundamental frequency with 1st overtone as well as mean variation of their frequency. It was revealed by simulation that the suggested feature vector has excellent discrimination in target signal identification from various interfering signals including frequency variation with time. By comparing Fisher scores, three features based on frequency show outstanding discrimination of measured UAV signals with low signal to noise ratio (SNR). Detection performance with simulated interference signal is compared by MFCC by using ELM classifier and the suggested feature vector shows 37.6% of performance improvement As the SNR increases with time, the proposed feature can detect the target signal ahead of MFCC that needs 4.5 dB higher signal power to detect the target.

GIS-based Estimation of Climate-induced Soil Erosion in Imha Basin (기후변화에 따른 임하댐 유역의 GIS 기반 토양침식 추정)

  • Lee, Khil Ha;Lee, Geun Sang;Cho, Hong Yeon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3D
    • /
    • pp.423-429
    • /
    • 2008
  • The object of the present study is to estimate the potential effects of climate change and land use on soil erosion in the mid-east Korea. Simulated precipitation by CCCma climate model during 2030-2050 is used to model predicted soil erosion, and results are compared to observation. Simulation results allow relative comparison of the impact of climate change on soil erosion between current and predicted future condition. Expected land use changes driven by socio-economic change and plant growth driven by the increase of temperature and are taken into accounts in a comprehensive way. Mean precipitation increases by 17.7% (24.5%) for A2 (B2) during 2030-2050 compared to the observation period (1966-1998). In general predicted soil erosion for the B2 scenario is larger than that for the A2 scenario. Predicted soil erosion increases by 48%~90% under climate change except the scenario 1 and 2. Predicted soil erosion under the influence of temperature-induced fast plant growth, higher evapotranspiration rate, and fertilization effect (scenario 5 and 6) is approximately 25% less than that in the scenario 3 and 4. On the basis of the results it is said that precipitation and the corresponding soil erosion is likely to increase in the future and care needs to be taken in the study area.

Assessment of System Reliability and Capacity-Rating of Concrete Box-Girder Highway Brdiges (R.C 박스거교의 체계신뢰성 해석 및 안전도 평가)

  • 조효남;신재철
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.187-198
    • /
    • 1995
  • This paper develops practical and reallstic reliabllity models and methods for the evaluation of system rehability and system rellabllity based ratlng of R.C box glrder bridge superstructures. The precise prediction of reberved carrying capacity of bridge as d system is extremely difficult especially when the brldges are highly redundant and slgnlficantly deter 1or;itcd or dainagetl. Thls papel proposes a nt2w approach for the evaluation of reseived system c,drrying capaaty of br~dges in terms ot equ~vdleiit system strength, which may b~ ddcflned as a brtdge system strength correipcmdlng tu the system rehability of the bridge. This cm be ticrAvcd from an Inverse process bami or1 the con~ept of FOSM(F1rst Order Second Moment) form of system reliabihty index. The sf rength llmt state models for K C box girder br~dges suggested In the paper dre based on the basi~ bending and shear strength And thc system reliatxllty pro,~lerri of box gritier super structure 1s formuldted as parallel serles models obtalncd f ~ o m thc FMA(Fdilure blode Rp proath) based on major failure mc>clmusrns or c~itlcal fdure ,>tatcs of each nuder .WOSM(Ad-vanced First Order Second Moment) and IST(1mportance Sampling Technique) simulation algorithm are used for the reliability analysis of the proposed models.

Computer Simulation for the Thermal Analysis of the Energy Storage Board (에너지 축열보드 열해석을 위한 컴퓨터 수치해석)

  • 강용혁;엄태인;곽희열
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.224-232
    • /
    • 1999
  • Latent heat storage system using micro-encapsuled phase change material is effective method for floor heating of house and building. The temperature profile in capsule block and flow rate of hot water are important parameters for the development of heat storage system. In the present study, a mathematical model based on 3-D, non-steady state, Navier-Stokes equations, scalar conservation equations and turbulence model ($\kappa$-$\varepsilon$), is used to predict the temperature profiles in capsule and the velocity vectors in hot water pipe. The multi-block grids and fine grids embedding are used to join the circle in hot water pipe and square in capsule block. The phase change process of the capsule is quite complex not only because the size of phase change material is very small, but also because phase change material is mixed with the cement to form thermal storage block. In calculation, it's assumed that the phenomena of phase change is limited only the thermal properties of phase change material and the change of boundary is not happened in capsule. The purpose of this study is to calculate the temperature profiles in capsule block and velocity vectors in hot water pipe using the numerical calculation. Two kinds of thermal boundary condition were considered, the first (case 1) is the adiabatic condition for the both outside surfaces of the wall, the second (case 2) is the case in which one surface is natural convection with atmosphere and another surface is adaibatic. Calculation results are shown that the temperature profile in capsule block for case 1 is higher than that for case 2 due to less heat loss in adaibatic surface. Specially, in the domain of near Y=0, the difference of temperature is greater in case 1 than in case 2. The detailed experimental data of capsule block on the temperature profile and the thermal properties such as specific heat and coefficient of heat transfer with the various temperature are required to predict more exact phenomena of heat transfer.

  • PDF

Analysis of Characteristics for Bank Scour around Low Dam using 3D Numerical Simulation (3차원 수치모의를 이용한 보 접속부 세굴 특성 분석)

  • Jung, Suk Il;Yeo, Chang Geon;Yoon, Gwang Seok;Lee, Seung Oh
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.102-102
    • /
    • 2011
  • 보는 하천에서 취수나 하상유지를 위한 하천횡단구조물로 일반적으로 본체, 물받이, 바닥보호공 등으로 구성되며 제방 연결부 호안 및 밑다짐 등에 대한 설계기준이 하천설계기준에 제시되어 있다. 그러나 태풍 루사나 매미에 의한 피해사례를 보면 하천 횡단 구조물 본체가 파괴되는 피해 뿐만 아니라, 구조물과 제방과의 연결부가 세굴이 발생되어 붕괴되는 사례가 많이 발생하고 있다. 하천설계기준 해설(2009)에는 이러한 보와 제방의 연결부 부분을 연결호안이라하여 관련 기준을 제시하고 있으나, 설치구간의 길이를 정할 때 하천의 규모나 하도의 특성을 고려하지 못하고 일률적으로 결정하도록 하고 있다. 이에 건설기술연구원의 '보 및 낙차공 설계기술 개발 연구보고서'(윤광석 등, 2006)에서는 고정상 실험을 통해 연결호안 설치구간에 대한 실험식을 제시하였다. 본 연구에서는 3차원 수치모의를 통하여 건설기술연구원에서 수행하였던 실험을 재현하고, 제방을 이동상으로 하여 인자들 간의 상호 관계를 밝히며, 그 특성을 분석하고자 한다. 그리고 윤광석 등(2006)에 의해 제시된 실험식에 적용하여 검증하였다. 수치모의는 유량을 $0.7{\sim}2.8m^3/sec$까지 변화하며 수행하였으며, 유사의 대표입경은 0.63mm로, 상류수심은 1.0m로 일정하게 유지하였다. 수치모의는 평형세굴 발생 후, 최소 모의시간의 10%정도 지난 시간까지 하였다. 수치모의 결과는 다음과 같다. (1) 유량이 증가함에 따라 유속 및 Froude 수가 증가하여 상 하류부 세굴 발생 범위와 폭은 증가하였다. (2) 상류는 하류에 비해 유량에 따른 세굴발생 범위가 상대적으로 작게 나타났으며, 이는 하류단에 비해 상류단의 유속 및 Froude 수의 차이가 작았기 때문인 것으로 판단된다. (3) 세굴의 폭을 측정함으로써 세굴에 가장 취약한 부분을 짐작할 수 있으며, 설계에 반영되어 호안이나 옹벽의 두께결정에 적용한다면 세굴에 대해 좀 더 안전한 설계가 될 수 있을 것이다. (4) 건설기술연구원(2006)에서 제시한 식(1)과의 비교를 통해 수치모의 결과가 식(1)로부터 계산된 값보다 작음을 알 수 있으며, 그 이유는 식(1)의 범위는 와류영역구간을 나타내서 연결호안 설치구간 길이를 제시하고 있는 반면, 본 연구의 수치모의 결과는 세굴이 발생한 범위를 제시하였기 때문이다. 향후 보 높이와 좀 더 다양한 유량에 대한 경우를 수치모의하고, 이동상 제방에 대한 실험을 통해 명확한 식을 제안 할 것이다.

  • PDF

A Molecular Dynamics Simulation Study of Hydroxyls in Dioctahedral Phyllosilicates (분자동역학 시뮬레이션을 이용한 이팔면체 점토광물 수산기 연구)

  • Son, Sangbo;Kwon, Kideok D.
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.209-220
    • /
    • 2016
  • Clay minerals are a major player to determine geochemical cycles of trace metals and carbon in the critical zone which covers the atmosphere down to groundwater aquifers. Molecular dynamics (MD) simulations can examine the Earth materials at an atomic level and, therefore, provide detailed fundamental-level insights related to physicochemical properties of clay minerals. In the current study, we have applied classical MD simulations with clayFF force field to dioctahedral clay minerals (i.e., gibbsite, kaolinite, and pyrophyllite) to analyze and compare structural parameters (lattice parameter, atomic pair distance) with experiments. We further calculated vibrational power spectra for the hydroxyls of the minerals by using the MD simulations results. The MD simulations predicted lattice parameters and interatomic distances respectively deviated less than 0.1~3.7% and 5% from the experimental results. The stretching vibrational wavenumber of the hydroxyl groups were calculated $200-300cm^{-1}$ higher than experiment. However, the trends in the frequencies among different surface hydroxyl groups of each mineral was consistent with experimental results. The angle formed by the surface hydroxyl group with the (001) plane and hydrogen bond distances of the surface hydroxyls were consistent with experimental result trends. The inner hydroxyls, however, showed results somewhat deviated from reported data in the literature. These results indicate that molecular dynamics simulations with clayFF can be a useful method in elucidating the roles of surface hydroxyl groups in the adsorption of metal ions to clay minerals.

3-D Simulation of Pyroelectric IR Sensor and Design of Optimized Peripheral Circuit (초전형 적외선 센서의 3차원 모델링과 최적화된 주변회로 설계)

  • Min, Kyung-Jin;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.10
    • /
    • pp.33-41
    • /
    • 2000
  • Pyroelectric characteristics such as voltage responsivity, noise equivalent power and detectivity are modeled 3-dimensionaly considering th interaction of each parameters. Also, the circuit is designed to set up the frequency band width and the signal amplification of the pyroelectric IR sensor. The case of low frequency region shows that the voltage response increases with the independence of the sensor area as the thickness decreases. In the high frequency region, it is found that the voltage response with the load resistor of 20$G{\Omega}$ increases with the independence of the sensor thickness as the sensor area decreases. In the low frequency region, the detectivity becomes excellent at th load resistor of 20$G{\Omega}$, the sensor area larger than $4{\times}10^{-10}m^2$ and the sensor thickness thinner than $1{\times}10^{-5}m$, while, in the high frequency region, it shows high value at the sensor thickness thinner than $1{\times}10^{-5}m$ and the sensor area smaller than $2{\times}10^{-10}m^2$ with the independence of the load resistor. In the circuit design, quasi-boot-strap circuit is employed, in which a single op-amp is connected to the drain of JFFT. Desirable frequency band width, amplification rate and the remarkable drop of noise of about 56% from that of conventional circuits with double op-amps are obtained.

  • PDF

Influence of twisting angle between fixed contact and movable contact on arc driving force in 3petal spiral type vacuum interrupter (3petal spiral type vacuum interrupter에서 가동접점전극과 고정접점전극간의 마주보는 각도의 변화가 아크구동력에 미치는 영향)

  • Kim, Byoung-Chul;Yun, Jae-Hun;Lee, Seung-Soo;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.480-480
    • /
    • 2008
  • Vacuum circuit breaker(VCB) is now emerging as an alternative of gas circuit breaker(GCB) which uses SF6 gas as insulating material whose dielectric strength is outstanding. But we have to reduce SF6 gas because SF6 gas is one of greenhouse gas and efforts to reduce greenhouse gas are now trend of the world. Therefore, we can say VCB is the optimal alternative of GCB because vacuum is environmentally friendly. The vacuum interrupter is the core part of VCB to interrupt arcing current. There are mainly two methods to extinguish arc. One is radial magnetic field (RMF) method and the other is axial magnetic field (AMF) method. We deals with RMF method in this paper. Compared with AMP, RMF arc quenching method has different principle to extinguish arc. In case of RMF method, pinch effect is much larger than AMF method. Because of pinch effect RMF type contact electrodes have the single large spot which is severly damaged and melted while AMF type contact electrodes have small and multiple spots which are slightly damaged and melted. To prevent contact electrode being damaged and melted from high temperature-arc, RMF method uses Lorentz force to move arc. In this paper we calculated and compared the arc driving force of two cases and we analyzed the force acting on each part of arc by means of commercial finite element method software Maxwell 3D. They have 3petals and we considered two cases. One is the case when fixed(upper) and movable(lower) contacts are in mirror arrangement (Case 1). The other is the case when one of two contacts (movable contact) is revolved at maximum angle as possible as it can be (Case 2). And at each case above, we analyzed arc driving force at two positions, position 1 is the closest to the center of contact and position 2 is near the edge of petal on fixed contact. As a result we could find that Case 2 generated stronger arc driving force than Case 1 at position 1. But at position 2 Case 1 generated stronger arc driving force than Case 2. This simulation method can contribute to optimizing spiral-type electrode designs in a view of arc driving force.

  • PDF

Computational Optimization of Bioanalytical Parameters for the Evaluation of the Toxicity of the Phytomarker 1,4 Napthoquinone and its Metabolite 1,2,4-trihydroxynapththalene

  • Gopal, Velmani;AL Rashid, Mohammad Harun;Majumder, Sayani;Maiti, Partha Pratim;Mandal, Subhash C
    • Journal of Pharmacopuncture
    • /
    • v.18 no.2
    • /
    • pp.7-18
    • /
    • 2015
  • Objectives: Lawsone (1,4 naphthoquinone) is a non redox cycling compound that can be catalyzed by DT diaphorase (DTD) into 1,2,4-trihydroxynaphthalene (THN), which can generate reactive oxygen species by auto oxidation. The purpose of this study was to evaluate the toxicity of the phytomarker 1,4 naphthoquinone and its metabolite THN by using the molecular docking program AutoDock 4. Methods: The 3D structure of ligands such as hydrogen peroxide ($H_2O_2$), nitric oxide synthase (NOS), catalase (CAT), glutathione (GSH), glutathione reductase (GR), glucose 6-phosphate dehydrogenase (G6PDH) and nicotinamide adenine dinucleotide phosphate hydrogen (NADPH) were drawn using hyperchem drawing tools and minimizing the energy of all pdb files with the help of hyperchem by $MM^+$ followed by a semi-empirical (PM3) method. The docking process was studied with ligand molecules to identify suitable dockings at protein binding sites through annealing and genetic simulation algorithms. The program auto dock tools (ADT) was released as an extension suite to the python molecular viewer used to prepare proteins and ligands. Grids centered on active sites were obtained with spacings of $54{\times}55{\times}56$, and a grid spacing of 0.503 was calculated. Comparisons of Global and Local Search Methods in Drug Docking were adopted to determine parameters; a maximum number of 250,000 energy evaluations, a maximum number of generations of 27,000, and mutation and crossover rates of 0.02 and 0.8 were used. The number of docking runs was set to 10. Results: Lawsone and THN can be considered to efficiently bind with NOS, CAT, GSH, GR, G6PDH and NADPH, which has been confirmed through hydrogen bond affinity with the respective amino acids. Conclusion: Naphthoquinone derivatives of lawsone, which can be metabolized into THN by a catalyst DTD, were examined. Lawsone and THN were found to be identically potent molecules for their affinities for selected proteins.

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.