• Title/Summary/Keyword: 1 $\times$ 4 array

Search Result 384, Processing Time 0.028 seconds

Analysis of Four Pesticides, Isoproturon, Phenmedipham, Pyridate and Nitenpyram Residues by High-Performance Liquid Chromatography with Diode-Array Detector (HPLC를 이용한 Isoproturon, Phenmedipham, Pyridate 및 Nitenpyram 4종 성분의 잔류농약 분석법 개발)

  • Yang, Sung-Yong;Koo, Yun-Chang;Wang, Zeng;Heo, Kyeong;Kim, Hyeong-Kook;An, Eun-Mi;Shin, Han-Seung;Lee, Jin-Won;Lee, Kwang-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.8
    • /
    • pp.1165-1170
    • /
    • 2010
  • A method for the determination of four pesticide compounds, urea (isoproturon), bis-carbamate (phenmedipham), thiocarbamate (pyridate) and vinyllidenediamine (nitenpyram) were examined and analyzed by HPLC with C-18 column ($250\;mm{\times}4.6\;mm$, $5\;{\mu}m$ diameter particle size). Mobile phase consisted of deionized water, acetonitrile and 50 mM $KH_2PO_4$ (pH 2.5). Isoproturon and phenmedipham analytical condition was isocratic elution of the column with 50% solvent A (acetonitrile) and 50% solvent B (deionized water); pyridate was 85% solvent A (acetonitrile) and 15% solvent B (deionized water) at a flow rate of 1 mL/min; and nitenpyram analytical condition was 90% solvent A (50 mM $KH_2PO_4$, pH 2.5) and 10% solvent B (acetonitrile) at a flow rate of 1 mL/min. In results, retention times were 6.12, 8.63, 9.40 and 12.76 min for isoproturon, phenmedipham, pyridate and nitenpyram, respectively. All injection volumes were $10\;{\mu}L$ and the limit of quantitation was 0.05 mg/kg for four pesticide compounds, respectively. Recovery rate test was performed with three farm products, rice, apple and soybean. Four pesticide compounds were spiked at concentrations of 0.05, 0.1 and 0.5 mg/kg. The recovery rates were ranged from 70.18% to 118.08% and the standard deviations of all experiments were within 10%.

Characterization of Rabbit Retinal Ganglion Cells with Multichannel Recording (다채널기록법을 이용한 토끼 망막 신경절세포의 특성 분석)

  • Cho Hyun Sook;Jin Gye-Hwan;Goo Yong Sook
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.228-236
    • /
    • 2004
  • Retinal ganglion cells transmit visual scene as an action potential to visual cortex through optic nerve. Conventional recording method using single intra- or extra-cellular electrode enables us to understand the response of specific neuron on specific time. Therefore, it is not possible to determine how the nerve impulses in the population of retinal ganglion cells collectively encode the visual stimulus with conventional recording. This requires recording the simultaneous electrical signals of many neurons. Recent advances in multi-electrode recording have brought us closer to understanding how visual information is encoded by population of retinal ganglion cells. We examined how ganglion cells act together to encode a visual scene with multi-electrode array (MEA). With light stimulation (on duration: 2 sec, off duration: 5 sec) generated on a color monitor driven by custom-made software, we isolated three functional types of ganglion cell activities; ON (35.0$\pm$4.4%), OFF (31.4$\pm$1.9%), and ON/OFF cells (34.6$\pm$5.3%) (Total number of retinal pieces = 8). We observed that nearby neurons often fire action potential near synchrony (< 1 ms). And this narrow correlation is seen among cells within a cluster which is made of 6~8 cells. As there are many more synchronized firing patterns than ganglion cells, such a distributed code might allow the retina to compress a large number of distinct visual messages into a small number of ganglion cells.

  • PDF

Fabrication of Large Area Transmission Electro-Absorption Modulator with High Uniformity Backside Etching

  • Lee, Soo Kyung;Na, Byung Hoon;Choi, Hee Ju;Ju, Gun Wu;Jeon, Jin Myeong;Cho, Yong Chul;Park, Yong Hwa;Park, Chang Young;Lee, Yong Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.220-220
    • /
    • 2013
  • Surface-normal transmission electro-absorption modulator (EAM) are attractive for high-definition (HD) three-dimensional (3D) imaging application due to its features such as small system volume and simple epitaxial structure [1,2]. However, EAM in order to be used for HD 3D imaging system requires uniform modulation performance over large area. To achieve highly uniform modulation performance of EAM at the operating wavelength of 850 nm, it is extremely important to remove the GaAs substrate over large area since GaAs material has high absorption coefficient below 870 nm which corresponds to band-edge energy of GaAs (1.424 eV). In this study, we propose and experimentally demonstrate a transmission EAM in which highly selective backside etching methods which include lapping, dry etching and wet etching is carried out to remove the GaAs substrate for achieving highly uniform modulation performance. First, lapping process on GaAs substrate was carried out for different lapping speeds (5 rpm, 7 rpm, 10 rpm) and the thickness was measured over different areas of surface. For a lapping speed of 5 rpm, a highly uniform surface over a large area ($2{\times}1\;mm^2$) was obtained. Second, optimization of inductive coupled plasma-reactive ion etching (ICP-RIE) was carried out to achieve anisotropy and high etch rate. The dry etching carried out using a gas mixture of SiCl4 and Ar, each having a flow rate of 10 sccm and 40 sccm, respectively with an RF power of 50 W, ICP power of 400 W and chamber pressure of 2 mTorr was the optimum etching condition. Last, the rest of GaAs substrate was successfully removed by highly selective backside wet etching with pH adjusted solution of citric acid and hydrogen peroxide. Citric acid/hydrogen peroxide etching solution having a volume ratio of 5:1 was the best etching condition which provides not only high selectivity of 235:1 between GaAs and AlAs but also good etching profile [3]. The fabricated transmission EAM array have an amplitude modulation of more than 50% at the bias voltage of -9 V and maintains high uniformity of >90% over large area ($2{\times}1\;mm^2$). These results show that the fabricated transmission EAM with substrate removed is an excellent candidate to be used as an optical shutter for HD 3D imaging application.

  • PDF

Optimization of Backside Etching with High Uniformity for Large Area Transmission-Type Modulator

  • Lee, Soo-Kyung;Na, Byung-Hoon;Ju, Gun-Wu;Choi, Hee-Ju;Lee, Yong-Tak
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.319-320
    • /
    • 2012
  • Large aperture optical modulator called optical shutter is a key component to realize time-of-flight (TOF) based three dimensional (3D) imaging systems [1-2]. The transmission type electro-absorption modulator (EAM) is a prime candidate for 3D imaging systems due to its advantages such as small size, high modulation performance [3], and ease of forming two dimensional (2D) array over large area [4]. In order to use the EAM for 3D imaging systems, it is crucial to remove GaAs substrate over large area so as to obtain high uniformity modulation performance at 850 nm. In this study, we propose and experimentally demonstrate techniques for backside etching of GaAs substrate over a large area having high uniformity. Various methods such as lapping and polishing, dry etching for anisotropic etching, and wet etching ([20%] C6H8O7 : H2O2 = 5:1) for high selectivity backside etching [5] are employed. A high transmittance of 80% over the large aperture area ($5{\times}5mm^2$) can be obtained with good uniformity through optimized backside etching method. These results reveal that the proposed methods for backside etching can etch the substrate over a large area with high uniformity, and the EAM fabricated by using backside etching method is an excellent candidate as optical shutter for 3D imaging systems.

  • PDF

Desulfurization efficiency in photobioreactors dependent on the irradiation type of light sources (광생물반응기내 광조사 유형별 탈황 효율)

  • An, Jin Young;Kim, Byung Woo
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.71-78
    • /
    • 2000
  • Removal rates of hydrogen sulfide were investigated to known effects of several light sources with external and internal irradiation on the desulfurization using C. thiosulfatophilum. In the case of internal illumination system, optical-fiber photobioreactor was applied to increase the light availability. Furthermore, sunlight was used as the main light energy in the daytime and metal-halide lamp was applied as an additional light energy at night. Light energy of 99% was saved by the application of the LED's array in comparison with the incandescent light source. $H_2S$ removal rates at 5,000 lux in a 4-L photobioreactor were shown as 0.040, 0.138, 0.136, and 0.134 (${\mu}mol$ $H_2S/min$)/(mg protein/L), respectively, in the following order of light sources, when several light sources such as fluorescent, energy-saving, incandescent, halogen lamp, and filtered light at 460 nm were applied. Removal rate per unit cell concentration with the internal light diffused optical-fibers increased about 1 six times as much as that with the external light sources. Removal rate per unit cell concentration, using sunlight in the daytime and a metal-halide lamp at night, was 0.41 less than 0.869 (${\mu}mol$ $H_2S/min$)/(mg protein/L) using a 400 W metal-halide lamp day and night, since the automatic sunlight collection system can transmit the light intensity as only 10% of that with a metal-halide lamp.

  • PDF

Validation and Determination of Glycyrrhizic Acid as a Marker Substance in Bu-Zhong-Yi-Qi-Tang by HPLC/DAD (HPLC/DAD에 의한 보중익기탕 중의 글리시리진산 정량분석법의 확립)

  • Baek, Ju-Hyun;Kim, Sun-Min;Ahn, Ji-Won;Cho, Chang-Hee;Oh, Mi-Hyune;Cho, Jung-Hee;Lee, Mi-Kyeong;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.52 no.1
    • /
    • pp.7-11
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the determination of glycyrrhizic acid was developed for the quality control of traditional herbal medicinal preparation Bu-Zhong-Yi-Qi-Tang (BZYQT), which is well-known herbal medicine used as tonic. RP-HPLC analysis was carried out using Capcell pak $C_{18}$ MG column $(5\;{\mu},\;150{\times}4.6\;mm)$ and a mobile phase consisting of acetonitrile and water containing 0.03% phosphoric acid (pH 2.46) at a flow rate of 1.0 ml/min. The optimum wavelength for the detection of the glycyrrhizic acid was found at 250 nm using diode-array UV/VIS detector. The glycyrrhizic acid in BZYQT shows good linearity $(r^2>0.999)$ in the range of $15\;{\mu}g/ml$ to 500 ${\mu}g/ml$. The limit of detection (LOD) was less than 5 ng and R.S.D for intra-day and inter-day reproducibility was less than 7%. The mean recovery of the glycyrrhizic acid was $97.3{\sim}113.0%$. These results suggest that the developed HPLC method is simple and efficient, and could be contributed for the quality control of commercial BZYQT products.

Image Edge Detector Based on a Bump Circuit and the Neighbor Pixels (Bump 회로와 인접픽셀 기반의 이미지 신호 Edge Detector)

  • Oh, Kwang-Seok;Lee, Sang-Jin;Cho, Kyoungrok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.149-156
    • /
    • 2013
  • This paper presents a hardware edge detector of image signal at pixel level of CMOS image sensor (CIS). The circuit detects edges of an image based on a bump circuit combining with the pixels. The APS converts light into electrical signals and the bump circuit compares the brightness between the target pixel and its neighbor pixels. Each column on CIS 64 by 64 pixels array shares a comparator. The comparator decides a peak level of the target pixel comparing with a reference voltage. The proposed edge detector is implemented using 0.18um CMOS technology. The circuit shows higher fill factor 34% and power dissipation by 0.9uW per pixel at 1.8V supply.

Quality Evaluation of Modified Bo-Yang-Hwan-O-Tang by Capillary Electrophoresis and High-performance Liquid Chromatography

  • Chen, Jianbo;Wu, Enqi;Zhu, Hongmei;Lee, Kwan-Jun;Chu, Van Men;Cho, Cheong-Weon;Kim, Young-Ho;Park, Yong-Ki;Lee, Won-Jae;Kang, Jong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2666-2670
    • /
    • 2011
  • High-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) were used to identify five active components in the modified herbal decoction Bo-Yang-Hwan-O-Tang (mBHT), i.e., amygdalin, decursin, paeoniflorin, salvianolic acid B, and calycosin-7-O-${\beta}$-D-glycoside. These components were identified by comparing their retention times and mass spectra with those of reference compounds. The conditions of both analytical methods were optimized and validated. Sufficient separation of target analytes was achieved using a buffer consisting of 40 mM sodium borate and 60 mM sodium dodecylsulfate (SDS) containing 10% methanol (pH 9.5) at 250 nm for CE analysis and gradient elution with a water-methanol mobile phase and ultraviolet (UV) photodiode array detector (DAD) at 250 nm for HPLC analysis. The mBHT components were determined within 65 min by HPLC and 16 min by CE. All calibration curves showed high linearity (R > 0.999) within the ranges tested. Intra-day and inter-day precision were less than 1.6% and 1.8% for HPLC and 2.5% and 4.8% for CE, respectively. The accuracy of the methods ranged from 98.8% to 102.3% for HPLC and from 95.9% to 108.2% for CE.

Effect of Design Factors on the Performance of Stratified Thermal Storage Tank (성층축열조의 성능에 대한 설계인자의 영향)

  • Chung Jae Dong;Park Joohyuk;Cho Sung-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1077-1083
    • /
    • 2004
  • This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.

Study of Magnetic Field Shielded Sputtering Process as a Room Temperature High Quality ITO Thin Film Deposition Process

  • Lee, Jun-Young;Jang, Yun-Sung;Lee, You-Jong;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.288-289
    • /
    • 2011
  • Indium Tin Oxide (ITO) is a typical highly Transparent Conductive Oxide (TCO) currently used as a transparent electrode material. Most widely used deposition method is the sputtering process for ITO film deposition because it has a high deposition rate, allows accurate control of the film thickness and easy deposition process and high electrical/optical properties. However, to apply high quality ITO thin film in a flexible microelectronic device using a plastic substrate, conventional DC magnetron sputtering (DMS) processed ITO thin film is not suitable because it needs a high temperature thermal annealing process to obtain high optical transmittance and low resistivity, while the generally plastic substrates has low glass transition temperatures. In the room temperature sputtering process, the electrical property degradation of ITO thin film is caused by negative oxygen ions effect. This high energy negative oxygen ions(about over 100eV) can be critical physical bombardment damages against the formation of the ITO thin film, and this damage does not recover in the room temperature process that does not offer thermal annealing. Hence new ITO deposition process that can provide the high electrical/optical properties of the ITO film at room temperature is needed. To solve these limitations we develop the Magnetic Field Shielded Sputtering (MFSS) system. The MFSS is based on DMS and it has the plasma limiter, which compose the permanent magnet array (Fig.1). During the ITO thin film deposition in the MFSS process, the electrons in the plasma are trapped by the magnetic field at the plasma limiters. The plasma limiter, which has a negative potential in the MFSS process, prevents to the damage by negative oxygen ions bombardment, and increases the heat(-) up effect by the Ar ions in the bulk plasma. Fig. 2. shows the electrical properties of the MFSS ITO thin film and DMS ITO thin film at room temperature. With the increase of the sputtering pressure, the resistivity of DMS ITO increases. On the other hand, the resistivity of the MFSS ITO slightly increases and becomes lower than that of the DMS ITO at all sputtering pressures. The lowest resistivity of the DMS ITO is $1.0{\times}10-3{\Omega}{\cdot}cm$ and that of the MFSS ITO is $4.5{\times}10-4{\Omega}{\cdot}cm$. This resistivity difference is caused by the carrier mobility. The carrier mobility of the MFSS ITO is 40 $cm^2/V{\cdot}s$, which is significantly higher than that of the DMS ITO (10 $cm^2/V{\cdot}s$). The low resistivity and high carrier mobility of the MFSS ITO are due to the magnetic field shielded effect. In addition, although not shown in this paper, the roughness of the MFSS ITO thin film is lower than that of the DMS ITO thin film, and TEM, XRD and XPS analysis of the MFSS ITO show the nano-crystalline structure. As a result, the MFSS process can effectively prevent to the high energy negative oxygen ions bombardment and supply activation energies by accelerating Ar ions in the plasma; therefore, high quality ITO can be deposited at room temperature.

  • PDF