• Title/Summary/Keyword: 1층 운동제어

Search Result 5, Processing Time 0.022 seconds

Development and Evaluation of 1 Layer Polar Motion Control System for Solar Tracker (태양광 추적장치용 1층 구조의 극좌표 운동기구 개발 및 평가)

  • Kim, Sun Ho;Kim, Byung Cheol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.67-73
    • /
    • 2010
  • Finding sufficient supplies of clean energy for future is one of the society's most important challenges according to technologies. Alternative renewable energy source such as sun energy can be substituted for exceeding human energy need. The main factor affect to solar performance is a collective intensity. To enhance intensity, suitable equipment is a solar tracker. This paper presents design and evaluation of 1 layer polar motion control system for solar tracker suitable for building integrated system. To evaluation of tracking accuracy and adaptability, solar tracker with 64 links is implemented. In experimental results, the accuracy of tracking has under ${\pm}0.0287^{\circ}$ and the thickness has under 140mm.

Study on the Motion Control of Tall Buliding Using Mega-Sub System (주(主)-부(副)구조 시스템을 이용한 초고층 건물의 진동제어에 관한 연구)

  • 김진구;송영훈
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.1 no.3
    • /
    • pp.29-35
    • /
    • 1997
  • The megastructure combined with the modular concept is an effcient structural system adequate for ultra-tail buildings for the future. An ingeneous structural control system can be developed by separating the internal subframe in one or many modules from the external megaframe, thus taking advantage of the effect of tuned mass dampers without adding any aditional mass. This so called mega-subcontrol system is generally modeled by a 20DF system for parametric study and for finding optimal values of the parameters. In this study the equation of motion for the system is obtained frist and the preconditions for the simplified modeling are investigated. Finally the optimal value for the subsreucture strffness is fomputed with given mass and damping ratios and transfer functions for responses are abtained for white noise ground exitation to verify the effectiveness of the mega-subcontrol system.

  • PDF

A Study on Separation Control by Local Suction in Front of a Hemisphere in Laminar Flow (층류경계층 내 반구 전방의 국부적인 흡입에 의한 표면 박리 제어)

  • Kang, Yong-Duck;An, Nam-Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.1
    • /
    • pp.92-100
    • /
    • 2018
  • Vortical systems are considered a main feature to sustain turbulence in a boundary layer through interaction. Such turbulent structures result in frictional drag and erosion or vibration in engineering applications. Research for controlling turbulent flow has been actively carried out, but in order to show the effect of vortices in a turbulent boundary layer, it is necessary to clarify the mechanism by which turbulent energy is transferred. For this purpose, it is convenient to demonstrate and capture phenomena in a laminar boundary layer. Therefore, in this study, the interactions of disturbed flow around a hemisphere on a flat plate in laminar flow were analyzed. In other words, a street of hairpin vortices was generated following a wake region formed after flow separation occurred over a hemisphere. Necklace vortices surrounding the hemisphere also appeared due to a strong adverse pressure gradient that brought high momentum fluid into the wake region thereby leading to an increase in the frequency of hairpin vortices. To mitigate the effect of these necklace vortices, local suction control was applied through a hole in front of the hemisphere. Flow visualization was recorded to qualitatively determine flow modifications, and hot-film measurements quantitatively supported conclusions on how much the power of the hairpin vortices was reduced by local wall suction.

Electrical properties of multilayer actuator and linear ultrasonic motor using low temperature PZW-PMN-PZT ceramics (저온소결 PZW-PMN-PZT 세라믹을 이용한 적층액츄에이터 및 선형초음파 모터의 전긱적 특성)

  • Lee, Il-Ha;Yoo, Ju-Hyun;Hong, Jae-Il;Jeong, Yeong-Ho;Yoon, Hyun-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.206-206
    • /
    • 2008
  • 압전소자를 이용한 초음파 모터는 전자기적 원리로 동작하는 기존의 모터에 비해 구조가 간단하고 소형, 경량화가 가능하며 저속에서 큰 토크가 가능하고 ${\mu}m$단위 까지 정밀제어가 가능하다는 장점 등으로 인해 그 응용분야가 점차 확대되고 있다. 초음파 모터의 원리는 수평과 수직방향에서 변위가 타원형 운동을 형성하는 것이다. 따라서 선택한 타원운동의 방식에 의해서 모터의 형상이 달라진다. 초음파 모터는 액츄에이터를 사용하여 만들기 때문에 액츄에이터의 특성은 모터의 타원변위나 토크에 영향을 미친다. 단판형 액츄에이터에 비하여 적층 액츄에이터는 입력 임피던스를 낮추어 낮은 구동전압에서 구동이 가능하며 큰 변위와 토크를 발생하기 때문에 진동자의 수명 향상과 구동전압을 낮추기에 적합하다. 적층 액츄에이터는 변위량이나 응력 등을 개선하기 위해서 전기기계 결합계수(kp) 및 압전 d상수가 큰 재료가 요구되며, 고전압에서 장시간 구동 시 마찰에 의한 열손실을 감소시키기 위해 높은 기계적 품질계수(Qm)를 가져야한다. 적층 시 내부전극으로 사용하는 Pd, Pt가 함유된 전극은 가격이 비싸 제조비용을 상승시킨다. 상대적으로 값싼 Ag전극을 사용하면 비용절감을 할 수 있지만 융점이 낮아서 저온소결이 불가피하다. 따라서, 특성이 우수한 적층 액츄에이터를 제조하기 위해서 저손실, 저온소결 할 수 있는 액츄에이터 재료가 필요한 실정이다. L1-B4 혈 선혈 초음파 모터는 L1모드와 B4모드의 공진 주파수가 일치하여야 큰 변위를 얻을 수 있는데 이전의 논문에서 Atila를 이용한 시뮬레이션 결과를 분석한 봐 있다. 적층 액츄에이터의 층수를 5,7,9,11,13,15층으로 하여 L1-B4모드에서의 공진주파수를 비교한 결과 13 층일 때 두 모드가 비슷한 공진주파수를 보였고, 티원변위궤적도 다른 층수에 비해 크게 나타났다. 본 연구에서는 시뮬레이션 결과 가장 좋은 특성을 보인 13층 액츄에이터로 선형 초음파 모터를 제작하였다. 또한, 액츄에이터는 압전 및 유전특성이 우수한 저온소결 PZW-PMN-PZT세라믹을 이용하여 제작하였고, 내부전극으로 Ag전극을 사용하였다. 제작된 13 층 선형초음파모터를 가지고 프리로드 및 전압에 따른 속도를 조사하였고, 시뮬레이션 결과와 비교해 보았다.

  • PDF

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.