• Title/Summary/Keyword: 1차 전기장

Search Result 95, Processing Time 0.029 seconds

Negative Apparent Resistivity in Resistivity Method (전기비저항탐사에서 음의 겉보기 비저항)

  • Cho In-Ky;Kim Jung-Ho;Chung Seung-Hwan;Suh Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.199-205
    • /
    • 2002
  • In the resistivity method, the potential difference between two grounded electrodes is measured and this can be positive or negative. The apparent resistivity and the potential difference have the same polarity. Since the electric field is the gradient of the potential, the polarity of the potential difference depends on the direction of the electric field. If the direction of the vector connecting two grounded electrodes is the same to that of the electric field, the measured potential difference and the apparent resistivity become positive. If the opposite is the case, they become negative. In general, the primary electric field and the vector connecting two potential electrodes have the same direction in a surface resistivity method. In this case, the measured potential difference is always positive because the primary electric field is greater than the secondary field. Therefore, the apparent resistivity is always positive if noise is free and topography is flat. The secondary field component, however, can be greater than the primary field component along the vector connecting two potential electrodes in the cross-hole resistivity method. Furthermore, if the secondary electric field and the vector connecting two potential electrodes have an opposite direction, the apparent resistivity become negative. Consequently, the apparent resistivity may be negative in the region where the primary electric field component along the vector connecting two potential electrodes is very small.

플라즈마 전기적 진단 기술

  • Yu, Sin-Jae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.91.1-91.1
    • /
    • 2016
  • 플라즈마 전기적인 진단 방법이라 함은 플라즈마에 전기장을 인가하고 이로 인해 도출되는 전류와 그 위상차를 구하여 플라즈마의 임피던스를 얻는 방법을 통칭한다. 이러한 방법은 임피던스라는 raw data에서 출발하지만 플라즈마와 전기장의 상호작용에 따라 다양한 플라즈마 진단 모델이 적용될 수 있으며, 이러한 모델을 통해 다양한 플라즈마 변수 (플라즈마 밀도, 온도, 전위 등등)들을 도출할 수 있는 것이 특징이라고 할 수 있다. 본 발표에서는 진단에 사용되는 주파수와 진단기의 형상에 따라 달라지는 외부 전기장와 플라즈마의 전기적인 상호작용을 살펴보고, 어떻게 플라즈마 전기적 진단기술이 성립되는지를 다양한 전기적 진단 기술을 소개하면서 설명하고자 한다.

  • PDF

EXB 하전입자빔 에너지 필터의 광학 특성

  • Jo, Bok-Rae;Heo, In-Hye;Park, In-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.608-608
    • /
    • 2013
  • 직선운동하는 하전입자의 진행방향에 수직한 평면상에 서로 직교하는 전기장과 자기장을 걸어주면, 하전입자에는 전기장에 의한 힘 $F_E$와 자기장과 속도 v에 의한 로렌츠력 $F_B=q(v{\times}B)$가 동시에 작용하게 된다. 이때 Wien 조건 $F_B=-F_E$를 만족하는 질량 $m_A$과, 에너지 $E_A$를 가지는 하전입자 A는 휘지 않고 직선운동을 계속하나, 하전입자 A와 다른 에너지 $E_B(=E_A+{\delta}E)$나 질량 $m_B$ $(=m_A+{\delta}m)$을 가지는 하전입자는 휘게 되며, 그 휘는 정도는 ${\delta}E$${\delta}m$에 비례하게 된다. 이 현상을 이용하여 다양한 종류의 에너지 또는 질량 분석기가 독일, 미국, 일본 등의 분석기기 선진국에서 개발되어 왔고, 전자현미경의 이미지 필터로도 활용되고 있으며, 통상 EXB 필터 또는 발명자의 이름을 딴 Wien 필터로 불리어지고 있다. $E{\times}B$ 필터는 일반적인 하전입자빔 렌즈와 다른 광학특성을 가진다. 예를 들면 3차 이상의 기하 수차만 가지는 일반 렌즈와는 달리 $F_B$, $F_E$ 전자기력에 의해 다양한 2차 기하 수차를 가지게 되며, 초점거리 등의 1차 광학 특성도 일반 렌즈와는 다른 경향을 보여준다. 본 발표에서는 $E{\times}B$ 필터의 전후로 각각 6극자+4극자를 조합시킨 보정기를 배치시켜 필터의 에너지 분해능의 성능을 향상시킬 수 있음을 빔 궤도 방정식을 분석적으로 계산하여 보여준다. 위 에너지 필터 구성에서 4극자는 1차 광학 특성을 조정하는 역할을 하며 6극자는 2차 수차를 줄여주는 역할을 한다. 수치해석을 통해서는 6극자+4극자를 조합시킨 보정기와 $E{\times}B$ 필터의 좀더 정확한 전극 전압 등의 제어 수치를 추출하고, 빔 궤도 방정식 분석을 통한 수차 보정 알고리즘이 유효함을 보여준다.

  • PDF

Automatic Shimming Algorithm (Automatic Shimming 알고리즘)

  • Kim, C.Y.;Kim, H.J.;Kim, S.M.;Ahn, C.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.2885-2887
    • /
    • 1999
  • 초고속 영상 기법의 Echo Planar Imaging과 Spiral Scan Imaging 기법은 자기장의 inhomogeneity에 영향을 많이 받게 된다. 본 논문에서는 자기장의 inhomogeneity를 보정하는 기능인 shimming 기능을 자동으로 실행할 수 있는 알고리즘을 구현하였다. 자기장의 inhomogeneity를 보정하기 위해서 자기장에 생성될 수 있는 spherical harmonic function중 1차에 대해 보정을 시도하였고, 기존의 알고리즘보다 뛰어난 결과를 얻을 수 있었다.

  • PDF

Light modulation properties of the penferroelectric BLN-PZT ceramics (준강유전 BLZ-PZT 세라믹의 광변조특성)

  • 류기원;정장호;박인길;이영희
    • Electrical & Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.454-460
    • /
    • 1993
  • 본 연구에서는 준강유전 특성을 갖는 xBa(L $a_{1}$2/N $b_{1}$2/) $O_{3}$- (1-x)Pb(Z $r_{y}$ $Ti_{1-y}$) $O_{3}$ (x=8.5, 9.0[mol.%], y=65, 70[mol.%]) 세라믹을 2단 소성법으로 제작한 후, 조성 및 인가전계에 따른 전기광학 특성 및 광변조 특성을 측정하였다. 인가전계가 증가함에 따라 8.5/65/35 시편을 제외한 전조성에서 유효복굴절이 2차 함수적으로 변화하는 2차 전기광학 특성을 나타내었으며 2차 전기광학계수, 반파장전압 및 ON-OFF ratio는 9.0/65/35 시편에서 각각 6.17x$10^{-16}$[ $m^{2}$/ $v^{2}$], 136[V], 252의 가장 우수한 값을 나타내었다. 9.0/70/30, 9.0/65/35 및 8.5/70/30 시편에 대해 광변조 특성을 측정한 결과, 입사광의 세기를 인가전압에 의해 변조시킬 수 있음을 관찰하였다.다.

  • PDF

Ohmic Heating Characteristics of Fermented Soybean Paste and Kochujang (된장 및 고추장의 Ohmic heating 특성)

  • Cho, Won-Il;Kim, Do-Un;Kim, Young-Suk;Pyun, Yu-Ryang
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.791-798
    • /
    • 1994
  • Ohmic heating is a food processing operation in which heat is internally generated within foods by the passage of alternating electric current. The process enables highly viscous paste foods such as Kochujang, and fermented soybean paste to be heated very fast. In order to develope the novel pasteurization process of paste foods, static Ohmic heating system was built, and heating characteristic during Ohmic heating under various conditions were studied. Electric conductivities of Kochujang and fermented soybean paste at room temperature were 1.865 S/m and 2.510 S/m, respectively and increased linearly with increasing temperature. Specific heating rate was highly dependent on the frequency. The highest heating rate was achieved at 5 KHz for Kochujang and 20 KHz for fermented soybean paste. Uniform heating throughout the sample was achieved during Ohmic heating with low frequency electrical currents, however above 5 KHz frequency, surface temperature was several degrees higher than the bulk.

  • PDF

Sterilization of Yakju(Rice Wine) on a Serial Multiple Electrode Pulsed Electric Field Treatment System (직렬배열 다중전극 고전압 펄스 전기장 처리장치를 이용한 약주의 살균)

  • Mok, Chull-Kyoon;Lee, Sang-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.356-362
    • /
    • 2000
  • Yakju(rice wine) was sterilized with high-voltage square-wave pulses of $1\;{\mu}s$ duration at various electric field strengths and frequencies on a serial multiple electrode pulsed electric field(PEF) treatment system consisted of 7 electrodes connected in series. The initial microbial counts of Yakju were $1.88{\times}10^3{\sim}2.13{\times}10^4$ CFU/mL for total aerobes, $1.55{\times}10^3{\sim}2.85{\times}10^4$ CFU/mL for lactic acid bacteria and $1.72{\times}10^3{\sim}2.39{\times}10^4$ CFU/mL for yeasts. The sterilization of microorganisms in Yakju was a first order reaction and the sterilization effect increased as the field strength and the frequency increased. The $D_{Hz}-value$ and the $D_{PEF}-value$ decreased with the electric field strength. Yeast showed lower $D_{PEF}-value$ than bacteria. Lactic acid bacteria showed lower $D_{PEF}-value$ than general aerobic bacteria under the electric field strength below 30 kV/cm, but higher ones under that above 40 kV/cm. The $Z_{PEF}-value$ of general aerobic bacteria, lactic acid bacteria and yeast in Yakju were 39.4, 49.3 and 47.6 kV/cm, respectively. The PEF sterilization resulted in less changes in color and sensory properties than heat sterilization, and the PEF treated Yakju showed superior quality to the heat treated one. The commercial sterilization of Yakju was accomplished with 2-cycle treatment on the tested serial PEF treatment system.

  • PDF

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

과학위성 1호 전력부

  • 신구환;임철우;신근수;김진규;이현우;임종태
    • Bulletin of the Korean Space Science Society
    • /
    • 2003.10a
    • /
    • pp.61-61
    • /
    • 2003
  • 과학위성 1호는 2003년 9월 26일 러시아 플레세츠크 발사장에서 발사되었다. 고도 690Km 상공에서 원형궤도를 그리며 우주에서의 임무수행을 시작했다. 과학위성 1호의 1차 전지는 태양으로부터 생산된 전기에너지를 사용하며, 2차 전지는 NiCd Battery를 사용한다. 이와 같이 1차 전지와 2차 전지를 최적의 상태로 제어하여 위성의 전력공급시스템으로써의 역할을 수행하게 될 과학위성 1호 전력시스템은 크게 Solar Power Regulator(SPR), Power Supply Unit(PSU), Power Distribution Unit(PDU), 및 Battery Cell Monitor / Pyrotechnic Device Support Equipment(BM/PDSE)로 구성 되어있다. 따라서, 본 논문에서는 과학위성 1호의 전력공급을 담당하는 System Unit 별 기능, 신호흐름, 전력분배 원칙 등에 대하여 연구하였다.

  • PDF