• Title/Summary/Keyword: 1차 냉각재

Search Result 44, Processing Time 0.021 seconds

An Investigation of Fluid Mixing with Direct Vessel Injection (직접용기주입에 따른 유체혼합에 관한 연구)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.63-77
    • /
    • 1994
  • The objective of this work is to investigate fluid mixing phenomena related to pressurized thermal shock(PTS) in a pressurized water reactor(PWR) vessel downcomer during transient cooldown with direct vessel injection(DVI) using test models. The test model designs were based on ABB Combustion Engineering(C-E) System 80+ reactor geometry. A cold leg small break loss-of-coolant accident(LOCA) md a main steam line teak were selected as the potential PTS events for the C-E System 80+. This work consist of two parts. The first part provides the visualization tests of the fluid mixing between DVI fluid and existing coolant in the downcomer region, and the second part is to compare the results of thermal mixing tests with DVI in the other test model. Row visualization tests with DVI have clarified the physical interaction between DVI fluid and primary coolant during transient cooldown. A significant temperature drop was observed in the downcomer during the tests of a small break LOCA Measured transient temperature profiles agree well with the predictions by the REMIX code for a small break LOCA and with the calculations by the COMMIX-1B code for a steam line break event.

  • PDF

An Investigation of Transient Responses of CANDU-6 PHTS Using DSNP (DSNP Language를 이용한 CANDU-6 PHTS 과도상태)

  • 전용준;박지원;오세기;정근모
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.103-114
    • /
    • 1995
  • 본 연구는 원자력발전소용 시뮬레이션 언어인 DSNP(Dynamic Simulator for Nuclear Power-plants)언어를 이용하여 CANDU-6 발전소 운전 모사 프로그램을 구성함으로써 핵심계통인 1차 냉각재 계통(PHTS)과 2차 계통 일부가 정상 및 과도조건에서 보일 수 있는 운전 상태를 연구하였다. DSNP 프로그램은 원자로심과 증기발생기에서의 열전달 모델, 열수송계통 펌프 모델 및 가압기 열수력 모델을 포함하고 있으며, 파이프(pipe)라는 단위 구성체를 이용하여 1차 냉각재계통을 노드화하여 계통 모사가 실현된다. 정상상태 100% 전출력 운전시 대표적인 운전변수를 기준으로 DSNP 결과와 CANDU-6 발전소 설계치를 비교해 본 결과 서로 매우 근사한 값을 나타내었으며, 이는 과도상태 모사의 초기조건으로 합당한 것으로 판단된다. 본 연구에서 선택된 과도상태 모사시 DSNP 프로그램은 매우 안정된 최종정상상태를 얻음에 따라 원자로의 기계 물리학적 변화를 합리적으로 모사하고 있음을 알 수 있었다. 최종 정상상태 회귀 이전의 동적 거동을 원자로 설계자료인 예비 안전성 평가 보고서(PSAR)와 비교한 결과 단기적 거동은 PSAR 결과와 다소 다른 점이 있었으나 전체적으로 합리적인 운전변수 값을 얻을 수 있었다. 단기적 거동에 대한 입증은 원자로 운전 자료를 통하여 가능할 것으로 사료된다. 이상과 같이 본 연구를 통해 구성한 DSNP 프로그램은 보완 및 개선의 여지가 있으나 현재의 수준으로도 CANDU-6 발전소의 일부 과도상태 모사가 가능한 것으로 판단된다.

  • PDF

A Study on Crystallization of Thermoplastic Aromatic Polymer (열가소성 방향족 폴리머의 결정화 특성에 대한 연구)

  • Park, Dong-Cheol;Park, Chang-Wook;Shin, Do-Hoon;Kim, Yun-Hae
    • Composites Research
    • /
    • v.31 no.2
    • /
    • pp.63-68
    • /
    • 2018
  • Thermoplastic composite has been limitedly used in high performance aerospace industry due to relatively low mechanical properties even though it has various advantages. But, thermoplastic aromatic polymer composite has recently been researched and utilized much. In this study, PEEK and PPS neat resin film as representative thermoplastic aromatic polymer were processed through continuous heating, cooling and reheating cycle. Property change such as glass transition temperature and melting temperature were identified and crystallinity variation by different cooling rate were evaluated. In the first (heating) run, polymer specimens were kept for 5 minutes at higher temperature than melting point to remove previous thermal history, and crystallization reaction was controlled by adjusting cooling rate to 2, 5, 10, 20 and $40^{\circ}C/minute$ in the second (cooling) run. In the third (heating) run, specimen crystallinity were verified by measuring the melting enthalpy. The initial specimens containing high portion of amorphous structure exhibited cold crystallization and clear glass transition in the first run whereas they did not show in the third run due to the increase of crystalline structure portion. As cooling rate decreases through the second cooling run, the crystallinity of the specimen increased. PEEK polymer had 21.9~39.3% crystallinity depending on cooling rate change whereas PPS polymer showed 29.1~31.2%.

600MW(e) CANDU PHTS Flow Instability and Interconnect Effect

  • Won Jae Lee;Jin Soo Kim;Goon Cherl Park
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.290-301
    • /
    • 1985
  • 600MW(e) CANDU Primary Heat Transport System (PHTS) is composed of the two “figure-of-eight” loops and is designed to operate with the 4% Reactor Outlet Header (ROH) quality at its rated power. This existence of the two compressible regions and the positive flow-qualitly-void feedbacks are the sources of the PHTS flow instability. To ensure the PHTS stability, ROH-ROH interconnect pipes are installed as passive systems. This paper describes the investigation of the PHTS flow instability at its design full power condition. Also studied are the interconnect effect and the inherent system damping effect on the system stability. The time domain stability analyses are accessed by using the ATHER/MOD-I code which is the improved version of the KAERI developed ATHER code. Under the most adverse system modelling, the “figure-of-eight” symmetric loop shows divergent flow oscillations. Under with the interconnect, the PHTS stability is remarkably enhanced so that the system becomes stable. However, even under the conservative pressurizer modelling, the PHTS shows the more convergent flow oscillations. With the interconnect and the pressurizer modelling, its stability is highly credited. Conclusively, the inherent system damping by pressurizer itself can credit the PHTS stability without the interconnect.

  • PDF

Development of temperature monitoring system of pressurizer surge tine thermal stratification (원전 원자로 냉각재 계통의 가압기 밀림배관 열성층 온도 감시 시스템 개발)

  • Ro, Jae-Hee;Kwon, Seok-Geon;Yi, Uk-Kun;Kim, Jung-Sun;Shon, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2501-2503
    • /
    • 2000
  • 본 연구는 윈자력발전소 원자로 냉각재 계통의 가압기 밀림배관내에서 서로 다른 온도의 유체가 밀도차에 의해 분리된 채 존재하는 열성층의 온도를 감시할 수 있는 시스템을 개발한다. 개발된 온도 감시 시스템은 국내원자력발전소 중 가장 오래된 고리원자력발전소 1호기의 수명연장과 관련하여 가압기 밀림배관의 열성층 온도를 측정하므로써 열성층화에 따른 배관의 건정성 여부를 평가하는데 사용한다.

  • PDF

The Verification Test for the Primary Piping System of Nuclear Power Plant (원자력 발전소 1차계통 배관 건전성 평가)

  • Lee, Hyun;Kim, Yearn-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.318-321
    • /
    • 1995
  • 원자력 발전소의 안전성 보장 및 신뢰성 향상을 위하여 시운전 단계에서 원자력 발전소내 안전등급에 해당하는 배관계통의 상태 확인을 위하여 각종시험을 하도록 되어있다. 특히 새로운 설계기념, 크기 또는 용량을 갖는 원자로 모델에 대해서는 필수적으로 건전성 평가를 하게 되었다. 이를 위해 발전소 건설기간에 시행하는 고온 기능시험 중에 원자로 주변 주요 시스템인 원자로 냉각재 루프 계통에 대한 건전성 확인을 위해 압전형 고온 가속도 센서를 이용하여 정상운전상태의 진동을 측정하여 시스템 진동거동을 규명하였다. 배관시스템의 일상운전상태는 유체의 흐름과 기기운전이 일정한 정상상태와 펌프의 기동 또는 정지 및 밸브의 급격한 개폐등으로 발생하는 과도상태로 나눌 수 있다. 따라서 두 가지 상태의 진동을 측정해야 한다. 배관계통은 정상운전 상태로 설계수명을 유지할 수 있어야 하므로 정상진도잉 최소화 되어야 한다. 진동 평가기준은 배관재질의 응력(S/N 커브) 곡선을 참조하여 설계수명내에 손상이 일어나지 않도록 재료의 허용응력을 산정하고 이를 진동변위로 환산하여 정한 것이며 이 값에 측정 데이타를 비교하여 1차계통 배관의 건전성을 확인하였다.

  • PDF

Measurement and Analyses of Radiation -Assessment of Defected Fuel by Analysis of Reactor Coolant Activities- (방사선 측정 및 해석 연구 -원자로 냉각수중의 방사능해석에 의한 결함핵연료봉의 평가-)

  • Yang, Jae-Choon;Oh, Hi-Peel;Jun, Jae-Shik;Lee, Ho-Yon;Oh, Heon-Jin;Chung, Moon-Kyu;Park, Hae-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.2
    • /
    • pp.139-145
    • /
    • 1986
  • An improved mothod of assessing fuel status by analyzsis of the fission product in the reactor coolant system is proposed. The release mechanism of specific fission products is established for determination of the coefficients in the equations which relate the radioactivities with the amount of defected fuel. Knock-out and migration models are employed in the formulation of the release mechanism. The influence of the tramp uranium is quantified. Sample calculations were made for KNU 1 reactor system using the I-131 and I-133 concentrations in the primary coolant. The estimated number of defected fuel pins in the third and sixth cycles appeared to be $9.34{\pm}1.13\;and\;0.294{\pm}0.092$, respectively.

  • PDF

A Study on Corrosion Product Behavior Prediction for Domestic PWR Primary System by using CRUDTRAN (CRUDTRAN을 이용한 국내 PWR 1차계통내 부식생성물 거동예측에 관한 연구)

  • Song, Jong Soon;Yoon, Tae-Bin;Lee, Sang-Heon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.4
    • /
    • pp.253-262
    • /
    • 2015
  • Radionuclide deposited on the surface of several internal and external systems in a nuclear power plant is created by the activation of corrosion products from nuclear reactor structural materials and fission products. Especially, the constant contact between water and the surface corrodes the inside where primary system makes coolants and corrosion products mixed. Also, these are circulated along the systems. For comparing models, CRUDTRAN, DISER, MIGA-RT and CPAIR codes are analyzed to predict the quantity of radionuclide and corrosion product of primary reactor that are used at the stage of designing. The corrosion products behavior of domestic PWR primary system was predicted by using CRUDTRAN. This study aims to increase the reliability of corrosion product evaluation model by comparing the actual values and calculated values with the data of a Westing House-type Nuclear Power Plant.

Ion Exchange Modeling with Sequencing Chemical Equilibrium (연속화학평형 모델을 이용한 이온교환 모델링)

  • 이인형;안현경
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.306-308
    • /
    • 2002
  • 원자로냉각재계통(Reactor Coolant System) 및 사용 후 저장조정화계통(Spent Fuel Pool Purification System)에는 양ㆍ음이온 교환수지가 충진된 혼상 이온교환수지탑을 설치하여 계통수에 존재하는 방사성 핵종을 제거하고 있으며, 정화율을 나타내는 제염계수(Decontamination Factor)가 특정값 이하이면 수지를 교체하고 있다. 그러나 특정 핵종에 대한 제염계수가 수지 사용기간에 관계없이 기준값 이하로 나타나고 있고, 수지탑의 성능을 예측하고 있지 못하는 실정이다. 원자력발전소 1차 계통에 설치되어 불순물을 제거하는 이온교환 수지탑에 대한 연속화학평형모델에 적용한 결과 수지탑에서 이온 용출은 수지에 대한 이온 선택도 순서와 동일하고 냉각재계통에는 붕산이 주성분이므로 음이온수지에서 붕산이 가장 먼저 누출된다. 그리고 붕산으로 포화된 음이온수지의 음이온 불순물 제거능력은 저하되지 않으며, 리튬으로 포화된 양이온수지의 양이온 불순물 제거능력은 저하된다.

원자로 냉각재 배관용 SA516-Gr.70 강의 파괴저항성에 미치는 온도 및 하중속도의 영향

  • 윤지현;이봉상;오용준;김진원;홍준화
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.48-53
    • /
    • 1998
  • 원자력 발전소 배관계통에 파단전 누설 (LBB) 설계개념의 적용을 위해서는 원자로 가동온도에서의 재료의 파괴저항성 평가가 필수적이다. 본 연구에서는 국내 원자로의 1차 냉각계통배관의 엘보우 소재로 사용되는 SA516-Gr.70 강의 파괴저항성에 미치는 DSA (Dynamic Strain Aging, 동적변형시효) 영향을 고찰하였다. 파괴저항성 평가를 위해 원자로 가동온도를 포함한 상온~50$0^{\circ}C$ 온도영역에서 준정적 하중에서부터 지진 하중 정도의 동적 하중까지 하중속도를 달리하여 직류전위차법 (DCPD) 이용하여 J-R 시험을 행하였다. J-R 시험결과, SA516-Gr.70 강은 특정한 온도와 하중속도의 조합에서 파괴저항성이 크게 떨어지는 양상을 보였으며, 낮은 파괴저항성을 나타내는 온도는 하중속도가 증가함에 따라 높은 온도쪽으로 이동하는 전형적인 DSA 감수성을 보였다. 인장시험을 통해서도 큰 폭의 serration 이 관찰되었으며 SA516-Gr.70 강에서 파괴저항성의 변화와 DSA 현상과의 연관성을 고찰하였다.

  • PDF