• Title/Summary/Keyword: 1단 압력

Search Result 244, Processing Time 0.027 seconds

체결 및 이탈겸용 4-팁 와셔 부품 설계

  • 김형원;문순일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.19-19
    • /
    • 1997
  • 휴대용 미사일의 1단과 2단 추진기관은 체결부품에 의하여 연결되어 발사관 내에서 운반되어지며, 발사 시 1단 추진기관이 분리되게 된다. 이때에 분리력은 1단 추진기관의 압력에 의하여 제공되고 체결부품인 4-팁 와셔는 어느 압력 이상을 받으면 추진기관의 1단과 2단을 분리한다. 정적시험을 하여 구한 결과를 해석치 와 비교했으며 실제상황에 유사한 동적 시험을 하여 필요한 안전계수를 구하였다.

  • PDF

Effect of needle tip design and position, and irrigant flow rate on apical pressure (주사침 말단의 형상과 위치, 세척액 주입속도가 치근단에 작용하는 압력에 미치는 영향)

  • Lee, Chang-Ha;Jo, Seol-Ah;Lim, Bum-Soon;Lee, In-Bog
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.275-286
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of needle tip design and position, and irrigant flow rate on apical pressure (AP) during root canal irrigation. Five human mandibular premolars were instrumented up to #35 (0.06 taper) using nickel-titanium rotary instruments. Three different needles according to change of needle tip design (notched, side-vented, and flat) were positioned at the point of 1, 3, and 5 mm from the apical constriction (needle tip position). For each needle tip design and position, APs were measured with varying flow rates of 0.05, 0.1, 0.2, and 0.3 ml/s. When the other conditions were controlled, AP increased with decreasing needle tip position or increasing irrigant flow rate (p<0.05). The AP of flat needle was the highest, followed by notched, side-vented needle for the same needle tip position and irrigant flow rate. The APs at needle tip position of 1 mm or with more than 0.1 ml/s flow rate were higher than central venous pressure (5.88 mmHg) for all conditions. Flat needle was not recommended for clinical use due to sharp increase of AP with changing needle tip position and irrigant flow rate. For safe and effective root canal irrigation, irrigant should be applied with the needle tip position of 3 mm and flow rate of less than 0.05 ml/s.

Basic Study on the Regenerator of Stirling Engine (III) - Temperature Distribution and Pressure drop property of the regenerator with steel wire - (스털링 기관용 재생기에 관한 기초 연구(III) - 철선을 축열재로 한 재생기의 온도 분포와 압력 강하 특성 -)

  • 김태한;오대건;이정택
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.548-557
    • /
    • 2002
  • 본 연구는 스털링 기관의 성능에 가장 큰 영향을 미치는 재생기의 설계에 적합한 축열재를 찾을 목적으로 단일 철선 종류(ø0.7, ø0.9, ø1.2, ø1.6, ø2.0, ø2.7), 복합 철선 4종류 (ø1.6-ø1.2, ø1.2-ø1.6, ø0.9-ø1.2, ø1.2-ø0.9), 철망-철선을 서로 다르게 혼합한 축열재 8종류(150-ø0.9, 150-ø01.2, ø0.9-150, ø1.2-150, 150-ø0.9-150, 150-ø1.2-150, 150-ø1.6-150, 150-ø2.0-150)을 공시 축열재로 하여 스털링 기관의 운전조건과 동일한 왕복 유동 상태에서 축열재의 삽입 방법에 따른 온도 분포 및 압력 강하 특성에 관한 실험을 수 행한 결과를 요약하면 다음과 같다. 1. 단일 철선을 축열재로 사용한 경우, 재생기 양단의 온도차는 단일 철선의 직경이 작을수록 커지는 경향을 보였으나, 양단의 압력 차는 단일 철선의 직경이 커질수록 작아졌다. 단일 철선 ø0.7과 ø0.9의 성능은 이들 2종류의 공시 축열재의 성능을 비교하기 위하여 재생기 양단의 온도차 증가에 따른 기관의 압력증가량과 압력강하 곡선의 차를 비교한 결과, 거의 비슷함을 알 수 있었으며 최적치를 나타냈다. 2. 복합 철선 4종류의 경우, 가열부 쪽에 ø1.2, 냉각부 쪽에 ø0.9를 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차가 큰 반면, 압력 차는 적으므로 재생기 축열재로서 더 적합한 것으로 나타났다. 복합 철선을 사용할 경우 가열부 쪽보다 냉각부 쪽에 철선 직경이 작은 것을 삽입하는 것이 효과적임을 알 수 있다. 또한 철선의 직경이 큰 것의 조합보다는 직경이 작은 철선의 조합이 재생기 양단의 온도차가 큼을 알 수 있다. 3. 철망-철선 혼합재를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.

  • PDF

Analysis on the Internal Flow of the Hydraulic Dual Chambers Applying Various Orifice (다양한 오리피스를 이용한 연결형 공압 챔버 내부 유동 해석)

  • Cho, Kihong;Park, Jungho;Kim, Euiyong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.58-64
    • /
    • 2014
  • Hydraulic dual chamber, as the simulator for a dual pulse rocket motor, was tested by a high pressure device with various orifice-hole size being applied. Pressure difference occurs between 1st chamber and 2nd chamber depending on area ratio of the orifice to nozzle throat. Studying a design configuration of the orifice is essential to the motor development because pressure difference severely affects the rocket motor performance. It is noticed in this study that energy dissipation is caused by the vortex flow originating from the orifice as the 2nd chamber is operated. The flow field is simulated by a commercial computational fluid dynamics program, ANSYS FLUENT V14.5.

Design of Velocity and Pressure Compounded Impulse Turbine (속도 및 압력 복합형 충동 터빈 설계)

  • Jeong, Eun-Hwan;Park, Pyun-Goo;Kim, Jin-Han
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.185-192
    • /
    • 2010
  • Design of velocity-compounded turbine for 75ton class LRE turbopump application and pressure compounded turbine for 30ton class LRE turbopump has been performed. 1D calculation and CFD analysis were conducted in determining blade and flow passage shape of velocity compounded turbine iteratively. Finally, 23.1% improved specific power and 5% reduced weight turbine to the original design was developed. In case of pressure-compounded supersonic turbine design, rotational speed was increased by 50% and the effect of carryover ratio, 2nd nozzle installation angle, leakage flow of 2nd nozzle, and work sharing factor was studied. Final 1D design resulted 36% increased specific power and 51% reduced weight comparing to the original single-row impulse turbine. It is anticipated that nozzle flow path design will be very important for the accomplishment of expected performance of pressure-compounded turbine and nozzle shape optimization will be conducted through the CFD analysis.

Prediction of the Thermal Efficiency at Increased Pressure Ratio in an F-Class Gas Turbine with Operating Data (F급 가스터빈의 압력비 증가 시 운전데이터를 이용한 열효율 변동 예측)

  • Park, Joon-Chul;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-sun;Lee, Jae Heon
    • Plant Journal
    • /
    • v.10 no.3
    • /
    • pp.39-44
    • /
    • 2014
  • The gas turbine thermal efficiency has been predicted when the compressor pressure ratio increases from the previously set 13.5. Thermal efficiency has been predicted from 14.2 up to 18.2 at which the turbine work reaches its maximum value on the assumption that isentropic efficiency of the compressor and the turbine are constant using the operating data at the pressure ratio of 13.5. 35.11% of thermal efficiency has been acquired by the performance test when the pressure ratio increased to 16.2 since replacing the compressor low pressure stages. It's been approved that predicting thermal efficiency using the operating data at the pressure ratio of 13.5 is useful within 7.86% of tolerance as the figure measured by the performance test.

  • PDF

Design and static structural analysis of KSLV-I upper stage cowls (KSLV-I 상단부 카울 설계 및 구조 해석)

  • An, Jae-Mo;Kim, Kwang-Soo;Jang, Young-Soon
    • Aerospace Engineering and Technology
    • /
    • v.6 no.2
    • /
    • pp.111-118
    • /
    • 2007
  • KSLV-I which is being developed in KARI is composed with two stages, and adaptor ring is used for coupling stage. Cables for interconnecting between stage is exposed on the outside. Also 8 pyro bolts which are installed in adaptor ring are used for separation of stage. In general, cowl is used for protecting exposed parts or structure which are anxious about damage from outer environment. In KSLV-I, two kind of cowls are designed. The one is umbilical cowl, and the other is pyro bolt cowl. Because cowl is exposed on the outside, heat and pressure load developed from air have effect on cowls. Therefore verification of structural strength through static analysis is required. In this study, static analysis in load condition except heat load is accomplished. In result of analysis, structural strength of pyro bolt cowl is verified. But breakage of umbilical cowl is confirmed in pressure load condition. So design of umbilical cowl is modified for satisfying required structural strength. And structural strength of umbilical cowl through analysis is verified.

  • PDF

Centrifugal Compressor Performance Assessment by Experiments and Numerical Simulations (수치해석 및 성능시험을 통한 원심압축기 성능 평가)

  • Kang, Young-Seok;Park, Tae-Choon;Yang, Soo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.341-344
    • /
    • 2009
  • 본 연구에서는 허브 대 팁의 비가 큰 원심형 압축기의 성능시험을 수행하였으며, 이를 수치해석 결과와 비교하였다. 압력비의 경우 작동 회전수에서 성능시험과 수치해석의 결과의 경향이 일치하는 것을 확인하였다. 성능시험에서 임펠러의 성능은 매우 높게 나타났으나, 1단 및 2단 디퓨져에서 손실이 발생하여 전체적인 압력비 및 효율이 떨어지는 것을 확인하였다. 수치해석을 통해 내부 유동장을 확인한 결과 1단 디퓨져 및 2단 디스월러에서 격렬한 2차 유동으로 인한 유로차폐효과가 주 손실원인임을 확인하였다.

  • PDF

Fabrication of silicon piezoresistive pressure sensor for a biomedical in-vivo measurements (생체 in-vivo 측정용 실리콘 압저항형 압력센서의 제조와 그 특성)

  • Bae, Hae-Jin;Son, Seung-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.148-155
    • /
    • 2001
  • A pressure sensor on the tip of a catheter which is utilized to measure the in-vivo pressure in a human body was fabricated and the characteristic of the pressure sensor as measured. To fit into a catheter with 1 mm caliber, samples of $150\;{\mu}m$(thickness) ${\times}$ (600, 700, 800, 900, 1000) ${\mu}m$(width) ${\times}2\;mm$(length) was fabricated. The thicker face with $450\;{\mu}m$ thickness of SDB wafer was made thin to $134\;{\mu}m$ thickness using KOH etchant and it made possible to fabricate sensor cell with the width shorter than 1 mm. Different to the whitstone bridge sensor, we formed one piezoresistor and one reference resistor in sensor. Therefore there are possibilities of reduction of the sensitivity, then by using the simulation tool ANSYS 5.5.1, the location and the type of the piezoresistor was optimized. Another piezoresistor type of sensor which contain one longitudinal and one transverse piezoresistor was fabricated at the same time, but the sensitivity was not improved very much. To get the output versus the pressure, a constant current source and a implementation amplifier was used. As a result, the maximum sensitivity of the sensor with one piezoresistor was $1.6\;{\mu}V/V/mmHg$.

  • PDF

하이브리드 모터를 적용한 초소형 공중발사체 설계

  • 권순탁;이창진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.77-77
    • /
    • 2002
  • 초소형 공중발사체 설계 시 하이브리드 모터의 적용가능성에 대한 연구를 실시하였다. HTPB/LOX를 추진제로 하여 마차바퀴형 연료 그레인, 산화제 탱크 가압방식을 사용하였고, 성능특성을 계산하기 위하여 하이브리드 연료의 연소율이 일정하다고 가정 하였다. 본 연구에 사용된 임무는 중량 3.5kg의 나노위성을 근지점 고도 200km, 원지점 고도 1,500km의 타원궤도로 진입시키는 것을 목적으로 하는 로켓의 1단 부분에 관한 것으로 1단의 발사속도는 M=1.3, 발사고도는 12km, 연소종료 고도는 40km이다. 1단에 대한 페이로드 중량은 127.5kg이고, 속도증가분($\Delta$V)은 3,330m/s이다. 모선은 F-4E를 사용하였고 모선의 특성상 발사체의 총 중량이 1,000kg이하로 제한되고 길이와 직경이 5m${\times}$5m로 제한되나 1단에 대한 길이의 제한조건은 현재까지 명확히 정립되지 않은 상태이다. 설계과정에서의 변수는 연료 그레인 포트 개수, 초기 산화제 플럭스, 연소실 압력을 사용했고, 설계 제한조건은 추진제 중량, 평균 비추력, 평균 추력, 연소시간, 1단 길이, 직경, 연소시간이고, 이들의 범위는 모선의 특성과 초소형 공중발사체의 임무특성에 맞게 설정하였다.

  • PDF