• 제목/요약/키워드: 1,2-dichlorobenzne

검색결과 2건 처리시간 0.015초

Solubilization Isotherms of Chlorobenzene in ionic Surfactant Solutions

  • Baek, Ki-Tae;Yang, Ji-Won
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.201-204
    • /
    • 2003
  • Solubilization isotherms of 1-chlorobenzene (MCB) and 1, 2-dichlorobenzene (DCB) were investigated in ionic surfactant solutions such as sodium dodecyl sulfate (SDS), cetylpyridinium chloride (CPC), and dedecyltrimethylammonium chloride (DMAC). The solubilization extent of DCB was much higher than that of MCB because of the main driving force of solubilization Is hydrophobic interactions between chlorobenzenes and hydrophobic interior of ionic micelles and DCB is more hydrophobic than MCB. CPC showed highest solubilization capacity because of longest hydrophobic tails. Simultaneous solubilization of MCB and DCB decreased slightly the extent solubilization of both MCB and DCB because the solubilization locus in the micelles is same.

  • PDF

오존산화에 의한 수처리공정에서 VOCs의 제거 특성 (VOCs Removal in Drinking Water Treatment Process by Ozonation)

  • 한명호;최준호;임학상
    • 상하수도학회지
    • /
    • 제11권2호
    • /
    • pp.65-75
    • /
    • 1997
  • Removal characteristics of volatile organic carbons(VOCs) by ozone oxidation and other processes in the raw water of the 1st Nakdong water treatment plant were investigated. Dichrolomethane, toluene and other 7 compounds were detected in the raw water. With regard to detected 4 compounds in finally treated water, it was found that VOCs could not be removed effectively by traditional water treatment process. Benzene, 1,2-dichlorobenzne were not detected in the raw water but they were detected in the process of treatment. The compound of highest detection frequency was dichloromethane. When the raw water was controlled at pH 7, temperature $20^{\circ}C$, 5 minutes as contact time, 10 minutes as reaction time, the removal rate of THMFP, $KMnO_4$ demand, TOC, $UV_{254nm}$ and $NH_3-N$ were 46.4%, 22%, 19.6%, 31% and 8%, respectively. From estimating the finally treated water qualities in 7 kinds of treatment processes, P-6 process(raw water-chlorination-coagulation-ozonation) was most effective for organics removal and THMs control. Removal efficiencies for $KMnO_4$ demand and TOC by the process which combined preozonation with coagulation was twice better than only preozonation. $NH_3-N$ removal rate was shown as 10% by P-3 process(raw water-coagulation-ozonation), but 83% of $NH_3-N$ was removed by P-4 process(raw water-coagulation-chlorination). It was found that the chlorination is more effective than the ozonation for the NH3-N removal as commonly known.

  • PDF