• Title/Summary/Keyword: 04A25

Search Result 1,413, Processing Time 0.038 seconds

Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature

  • Gundogar, Mustafa;Uslu, Gulsah;Ozyurek, Taha;Plotino, Gianluca
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.3
    • /
    • pp.37.1-37.8
    • /
    • 2020
  • Objectives: This study aims to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium (NiTi) rotary files at body temperature. Materials and Methods: In total, 80 VDW.ROTATE (25/0.04), TruNatomy (26/0.04), 2Shape (25/0.04), and HyFlex CM (25/0.04) NiTi rotary files (n = 20 in each group) were subjected to static cyclic fatigue testing at body temperature (37℃) in stainless-steel artificial canals prepared according to the size and taper of the instruments until fracture occurred. The number of cycles to fracture (NCF) was calculated, and the lengths of the fractured fragments were measured. The data were statistically analyzed using a 1-way analysis of variance and post hoc Tamhane tests at the 5% significance level (p < 0.05). Results: There were significant differences in the cyclic fatigue resistance among the groups (p < 0.05), with the highest to lowest NCF values of the files as follows: VDW.ROTATE, HyFlex CM, 2Shape, and TruNatomy. There was no significant difference in the lengths of the fractured fragments among the groups. The scanning electron microscope images of the files revealed typical characteristics of fracture due to cyclic fatigue. Conclusions: The VDW.ROTATE files had the highest cyclic fatigue resistance, and the TruNatomy and 2Shape files had the lowest cyclic fatigue resistance in artificial canals at body temperature.

Isolation and Characterization of Aerobic Trichloroethylene Cometabolizing Bacterium (호기적 Trichloroethylene 공동대사 세균의 분리 및 특성)

  • 김호성;박근태;손홍주;박성훈;이상준
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.99-103
    • /
    • 2001
  • Several microorganisms which degrade phenol and trichloroethylene(TCE) were isolated from the activated sludge of a wastewater treatment plant. Among them, one isolate EL-04J showed the highest degradability and was identified as a Pseudomonas species according to morphological, cultural and biochemical properties. The phenol-induced cells of Pseudomonas EL-04J, which were preincubated in the mineral salts medium containing phenol as a sole carbon source, degraded 90% of 25$\mu$M TCE within 20h. This strain could also utilize some of methylated phenol derivatives (o-cresol, m-cresol and p-cresol) as the sole source of carbon and energy. Cresol-induced cells of Pseudomonas EL-04J also cometabolized TCE.

  • PDF

A Comparison of Stainless Steel K-file, Profile .04, and Quantec LX Instruments to Shape Curved Root Canals in vitro (Stainless Steel K-file, Profile .04와 Quantec LX를 이용한 만곡 근관 형성후의 근관형태의 변화에 관한 비교연구)

  • Lim, Kyung-A;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.133-143
    • /
    • 2000
  • 목 적: 통상적인 근관성형 과정에서 근관형태의 직선화 경향을 발견할수 있으며 그 결과 만곡이 심한 근관에서 이상적인 근관 형태를 얻기가 어려움으로 인해 이를 극복하기 위한 많은 기구들과 근관 성형법들이 개선되었고 소개되었다. 본 연구에서는 수통형 Stainless Steel K-file, Niti 엔진 구동형 Profile .04와 Quantec LX file를 이용하여 만곡 근관의 성형 후 최종 근관 형태를 비교하고 평가하고자 한다. 방 법: 본 실험은 Bramante등의 방법을 변형하여 술 전의 근관 형태와 술 후의 근관 형태를 비교하였다. Schneider의 방법에 따라 $12^{\circ}$에서 $68^{\circ}$ 이내에 만독도를 가진 45개의 발거된 상하악 대구치의 근심근관들을 선택하여 15개씩 3개의 군으로 나누고 알루미늄으로 제작된 mold에 투명한 교정용 레진으로 매몰하였다. 근첨에서 2.5, 5, 8mm 지점에서 절단하고 각 mold에 재조립한 후 다음과 같이 근관 성형을 시행하였다. 제 1 군은 SS K-file를 이용하여 Step-back 방법; 제 2 군은 NiTi 엔진 구동형인 Profile .04 ; 제 3 군은 NiTi 엔진 구동형인 Quantec LX file로 근관 성형하였다. 술 전과 술 후에, 각 시편들을 입체 현미경으로 사진 촬영하여 근관 중심 위치 이동률, 근관성형 후 면적과 모양, 잔존 상아질의 최 소 두께를 Sigma scan / image software program으로 계산하고 One way ANOVA로 통계적 유의성을 검증하였다. 결 론: 1. Profile .04와 Quantec LX는 SS K-file보다 근관성형시 근관의 본 형태를 유지하는 경향이 있었으나 통계적으로 유의성이 없었다(p>0.05). 2. 근관 성형 후 면적은 Profile .04 엔진 구동형 NiTi file를 이용한 군이 다른 군과 비해 가장 적었으나 통계적으로 유의성이 없었다(p>0.05). 2. 모든 방법들은 같은 부위에서 같은 방향으로 전이되는 양상을 보였다. 즉, 근단부에서는 바깥쪽으로, 중앙부에서는 안쪽으로 전이하려는 경향이 있었다. 그러나, 치관부에는 그러한 법칙이 적용되지 않아 전이되는 양상이 안쪽이나 바깥쪽으로 구별되지 않게 일어났다. 3. 술 후에 근관의 모양은 원형, 타원형, 불균일한 형태들이 다양하게 나타났지만, Profile .04와 Quantec LX를 사용했을 때 주로 원형 형태의 근관을 보여주었으며 Stainless Steel K-file은 타원형이나 불균일한 근관 형태를 보였다.

  • PDF

The Effects of the Stirrup Length Fitted to the Rider's Lower Limb Length on the Riding Posture for Less Skilled Riders during Trot in Equestrian (승마 속보 시 미숙련자에게 적용한 하지장 비율 74.04% 등자길이 피팅의 기승자세 효과)

  • Hyun, Seung-Hyun;Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.3
    • /
    • pp.335-342
    • /
    • 2015
  • Objective : The purposes of this study was to analyze the effects of the stirrup length fitted to the rider's lower limb length and it's impact on less skilled riders during trot in equestrian events. Methods : Participants selected as subjects consisted of less skilled riders(n=5, mean age: $40.02{\pm}10.75yrs$, mean heights: $169.77{\pm}2.08cm$, mean body weights: $67.65{\pm}7.76kg$, lower limb lengths: $97.26{\pm}2.35cm$, mean horse heights: $164.00{\pm}5.74cm$ with 2 type of stirrups lengths(lower limb ratio 74.04%, and 79.18%) during trot. The variables analyzed consisted of the displacement for Y axis and Z axis(head, and center of mass[COM]) with asymmetric index, trunk front-rear angle(consistency index), lower limb joint(Right hip, knee, and ankle), and average vertical forces of horse rider during 1 stride in trot. The 4 camcorder(HDR-HC7/HDV 1080i, Spony Corp, Japan) was used to capture horse riding motion at a rate of 60 frames/sec. Raw data was collected from Kwon3D XP motion analysis package ver 4.0 program(Visol, Korea) during trot. Results : The movements and asymmetric index didn't show significant difference at head and COM, Also, 74.04% stirrups lengths in trunk tilting angle showed significant difference with higher consistency than that of 79.18% stirrups lengths. Hip and knee joint angle showed significant difference with more extended posture than that of 74.04% stirrups lengths during trot. Ankle angle of 79.18% stirrups length showed more plantarflexion than that of 74.04% stirrups lengths. Average vertical force of rider showed significant difference with higher force at 79.18% stirrups lengths than that of 74.04% stirrups lengths during stance phase. Conclusion : When considering the above, 74.04% stirrups length could be effective in impulse reduction with consistent posture in rather less skilled horse riders.

Iron and vitamin D status in breastfed infants and their mothers

  • Kang, Yu Sun;Kim, Joon Hwan;Ahn, Eun Hee;Yoo, Eun-Gyong;Kim, Moon Kyu
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.8
    • /
    • pp.283-287
    • /
    • 2015
  • Purpose: We assessed the relationships between iron and vitamin D statuses in breastfed infants and their mothers and evaluated the determinants of iron and vitamin D deficiencies in breastfed infants. Methods: Seventy breastfed infants aged 4-24 months and their mothers participated in this study from February 2012 to May 2013. Complete blood counts, total iron binding capacity, and levels of C-reactive protein, iron, ferritin, calcium, phosphate, alkaline phosphatase, and 25-hydroxyvitamin D (25(OH)D) in infants and their mothers were measured. Results: A history of maternal prepregnancy anemia was associated with lower ferritin and 25(OH)D levels in both infants and their mothers. The 25(OH)D level of infants correlated with maternal 25(OH) D levels. The independent risk factors for iron deficiency in breastfed infants were the duration of breastfeeding (odds ratio [OR], 6.54; 95% confidence interval [CI], 1.09-39.2; P=0.04) and infant body weight (OR, 2.65; 95% CI, 1.07-6.56; P=0.04). The determinants for vitamin D deficiency were the infant's age (OR, 0.15; 95% CI, 0.02-0.97; P=0.046) and maternal 25(OH)D level (OR, 0.74; 95% CI, 0.59-0.92; P=0.01). Conclusion: A maternal history of prepregnancy anemia requiring iron therapy was associated with lower current ferritin and 25(OH)D levels in both infants and their mothers. Therefore, physicians should monitor not only iron but also vitamin D levels in infants who are breastfed by mothers who had prepregnancy anemia.

Simultaneous and quantitative determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (토양 중 음이온 바이오사이드의 HPLC-MS/MS 동시 정량분석법)

  • Yang, Eun-Young;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.317-322
    • /
    • 2015
  • Simultaneous analytical method has developed for the determination of anion biocides in soil by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Chlorite and chlorate in soil were extracted with pure water, and cyanuric acid and sodium dodecylbenzenesulfonate (Na-DBS) were extracted with mobile phase (0.25 mM ammonium formate in 20 mM formic acid : acetonitrile (1:1)). The extract was injected into the LC-MS/MS system after filtration. The method detection limits in this study were 0.04 mg/kg for chlorite, 0.04 mg/kg for chlorate, 0.27 mg/kg for cyanuric acid, and 0.05 mg/kg for Na-DBS, respectively. The method was applied to the analysis of 50 soil samples collected from 40 sites sprayed with biocides and 10 background sites. As a result, anion biocides were not detected in all sites.

Korean Red Ginseng (Panax ginseng Meyer) with enriched Rg3 ameliorates chronic intermittent heat stress-induced testicular damage in rats via multifunctional approach

  • Kopalli, Spandana Rajendra;Cha, Kyu-Min;Hwang, Seock-Yeon;Jeong, Min-Sik;Kim, Si-Kwan
    • Journal of Ginseng Research
    • /
    • v.43 no.1
    • /
    • pp.135-142
    • /
    • 2019
  • Background: Panax ginseng Meyer, known as Korean Red Ginseng (KRG), is one of the important age-old traditional herbs used in boosting libido and improving male fertility. In this study, the effects of Rg3-enriched KRG extract (KGC04P) on heat stress-induced testicular damage in experimental rats was evaluated. Methods: Male rats (Sprague-Dawley) were divided into four groups (n = 10): normal control (NC), heat-stressed control (HC), heat-stressed plus KGC04P-100 mg/kg (HK100), and heat-stressed plus KGC04P-200 mg/kg (HK200) groups. Starting 1 week prior to heat stress, animals were administered orally with KGC04P (100 and 200 mg/kg) mixed with a regular pellet diet and continued for 25 weeks. Heat stress was induced to HC, HK100, and HK200 groups by intermittently exposing the animals to high temperatures ($32{\pm}1^{\circ}C$, 2 h/day). After 6 months, animals were euthanized under general anesthesia with carbon dioxide and evaluated for various parameters in serum and testicular tissue by using Western blotting, biochemical kits, and reverse transcription-polymerase chain reaction. Results: Significant (p < 0.05) alterations in several parameters, such as body/organ weight, sperm kinematics, and lipid metabolism marker levels, in the serum and testis of rats were observed. Further, the expression of testicular antioxidant enzymes, inflammatory cytokines, sex hormonal receptors, and spermatogenesis-related genes were also affected significantly (p < 0.05) in the heat-stressed group. However, KGC04P prevented the heat stress-induced changes in rats significantly (p < 0.05) at both concentrations. Conclusion: KGC04P attenuated heat stress-induced testicular damage by a multifunctional approach and can be developed as an excellent therapeutic agent for hyperthermia-mediated male infertility.

Effect of Feeding Rate for Operation Properties of Centrifugal Thin Film Evaporator (급액속도가 원심식 박막증발기의 운전 특성에 미치는 영향)

  • Kim, Byeong-Sam;Park, Noh-Hyun;Park, Moo-Hyun;Han, Bong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.437-441
    • /
    • 1991
  • During the evaporation of garlic juice by centrifugal thin film evaporator (Centri-Therm, CT-1B), the effect of feeding rate was investigated for its operation properties. On the process condition of feeding rate of 25 to 125 kg/h, theoretical average thickness of the garlic juice film on the rotating cone and residence time of the juice in the evaporator varied in the range of 0.52 to 0.89 mm and 1.77 to 6.75 second, respectively. And the flow of garlic juice was considered as a streamline flow by Reynolds number. At constant temperatures of steam and juice evaporation, concentration ratio decreased with the increase of the feeding rate. But the evapoartion rate and overall heat transfer coefficient increased with the increase of the feeding rate until the feeding rate reached a certain value and then decreased. On the conditions of $25{\leq}$feeding rate ${\leq}125\;kg/h$, evaporation temperature of $40^{\circ}C$, $95{\leq}steam$ $temperature≤120^{\circ}C$ and initial feed concentration of $32^{\circ}Brix$, concentration ratio and overall heat transfer coefficient were $1.04{\sim}2.04\;and\;3,074.33{\sim}17,614.70kJ/m^{2}{\cdot}h{\cdot}^{\circ}C$.

  • PDF

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.

A Design of Vehicle for Mobile 3D Printer (이동형 3D 프린터를 위한 차량 설계)

  • Jun-Young Park;Ha-Yeon Kim;Seung-Hoon Baek;Min-Seok Kim;Seung-Dae Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.177-184
    • /
    • 2023
  • In this paper, based on Arduino, a vehicle is installed at the bottom of the 3D printer so that Arduino controls the vehicle that can expand the moving space. A stepping motor was mounted on the front wheel of the vehicle and precisely controlled using a motor driver. As a result, when moving 5cm, 25cm, and 50cm, the mean value of error rate was 0.6%, 0.04%, and 0.02%, respectively, to enable accurate distance control.