• Title/Summary/Keyword: 0.13 um

Search Result 261, Processing Time 0.037 seconds

Calculations of Optical Properties of Cloud Particles to Improve the Accuracy of Forward Scattering Probes for In-Situ Aircraft Cloud Measurements (항공기 구름 관측에 사용되는 전방산란 관측 기기의 정확도 향상을 위한 구름입자의 광학적 특성 계산)

  • Um, Junshik
    • Atmosphere
    • /
    • v.30 no.1
    • /
    • pp.75-89
    • /
    • 2020
  • Current in-situ airborne probes that measure the sizes of ice crystals smaller than 50 ㎛ are based on the concept that the measured intensity of light scattered by a particle in the forward and/or backward direction can be converted to particle size. The relationship between particle size and scattered light used in forward scattering probes is based on Mie theory, which assumes the refractive index of particle is known and all particles are spherical. Not only are small crystals not spherical, but also there are a wide variety of non-spherical shapes. Although it is well known that the scattering properties of non-spherical ice crystals differ from those of spherical shapes, the impacts of non-sphericity on derived in-situ particle size distributions are unknown. Thus, precise relationships between the intensity of scattered light and particle size and shape are required, as based on accurate calculations of scattering properties of ice crystals. In this study, single-scattering properties of ice crystals smaller than 50 ㎛ are calculated at a wavelength of 0.55 ㎛ using a numerically exact method (i.e., discrete dipole approximation). For these calculations, hexagonal ice crystals with varying aspect ratios are used to represent the shapes of natural small ice crystals to determine the errors caused by non-spherical ice crystals measured by forward scattering probes. It is shown that the calculated errors in sizing nonspherical ice crystals are at least 13% and 26% in forward (4~12°) and backward (168~176°) directions, respectively, and maximum errors are up to 120% and 132%.

Energy-band model on photoresponse transitions in biased asymmetric dot-in-double-quantum-well infrared detector

  • Sin, Hyeon-Uk;Choe, Jeong-U;Kim, Jun-O;Lee, Sang-Jun;No, Sam-Gyu;Lee, Gyu-Seok;Krishna, S.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.234-234
    • /
    • 2010
  • The PR transitions in asymmetric dot-in-double-quantum-well (DdWELL) photodetector is identified by bias-dependent spectral behaviors. Discrete n-i-n infrared photodetectors were fabricated on a 30-period asymmetric InAs-QD/[InGaAs/GaAs]/AlGaAs DdWELL wafer that was prepared by MBE technique. A 2.0-monolayer (ML) InAs QD ensemble was embedded in upper combined well of InGaAs/GaAs and each stack is separated by a 50-nm AlGaAs barrier. Each pixel has circular aperture of 300 um in diameter, and the mesa cell ($410{\times}410\;{\mu}m^2$) was defined by shallow etching. PR measurements were performed in the spectral range of $3{\sim}13\;{\mu}m$ (~ 100-400 meV) by using a Fourier-transform infrared (FTIR) spectrometer and a low-noise preamplifier. The asymmetric photodetector exhibits unique transition behaviors that near-/far-infrared (NIR/FIR) photoresponse (PR) bands are blue/red shifted by the electric field, contrasted to mid-infrared (MIR) with no dependence. In addition, the MIR-FIR dual-band spectra change into single-band feature by the polarity. A four-level energy band model is proposed for the transition scheme, and the field dependence of FIR bands numerically calculated by a simplified DdWELL structure is in good agreement with that of the PR spectra. The wavelength shift by the field strength and the spectral change by the polarity are discussed on the basis of four-level transition.

  • PDF

Could the Injury Severity Score be a new indicator for surgical treatment in patients with traumatic splenic injury?

  • Jeong, HyeJeong;Jung, SungWon;Heo, Tae Gil;Choi, Pyong Wha;Kim, Jae Il;Jung, Sung Min;Jun, Heungman;Shin, Yong Chan;Um, Eunhae
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.189-194
    • /
    • 2022
  • Purpose: The purpose of this study was to determine whether a higher Injury Severity Score (ISS) could serve as an indicator of splenectomy in patients with traumatic splenic lacerations. Methods: A total of 256 cases of splenic laceration were collected from January 1, 2005 to December 31, 2018. After the application of exclusion criteria, 105 were eligible for this study. Charts were reviewed for demographic characteristics, initial vital signs upon presentation to the emergency room, Glasgow Coma Scale, computed tomography findings, ISS, and treatment strategies. The cases were then divided into nonsplenectomy and splenectomy groups for analysis. Results: When analyzed with the chi-square test and t-test, splenectomy was associated with a systolic blood pressure lower than 90 mmHg, a Glasgow Coma Scale score lower than 13, active bleeding found on computed tomography, a splenic laceration grade greater than or equal to 4, and an ISS greater than 15 at presentation. However, in multivariate logistic regression analysis, only active bleeding on computed tomography showed a statistically significant relationship (P=0.014). Conclusions: Although ISS failed to show a statistically significant independent relationship with splenectomy, it may still play a supplementary role in traumatic splenic injury management.

Clinical Characteristics of Elderly Patients with Pulmonary Tuberculosis (고령자 폐결핵에 대한 임상적 관찰)

  • Kim, Chung-Tae;Um, Hye-Suck;Lee, Hyang-Ju;Rhu, Nam-Soo;Cho, Dong-Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.432-440
    • /
    • 2000
  • Background : The prevalence of pulmonary tuberculosis among the elderly is increasing in Korea and in the developed countries due to the increased elderly population and their predispositions to chronic disease, poverty and decreased immunity. To define the characteristics of pulmonary tuberculosis in the elderly, we evaluated the clinical spectrum of pulmonary tuberculosis. Method : We analyzed 92 patients retrospectively that were diagnosed as active pulmonary tuberculosis over the age of 65. The analysis involved patient's profiles, clinical manifestations, coexisting diseases, diagnostic methods, anti-TB medications and their side effects, and treatment outcomes. Results : The results were as follows : - 1) The ratio of male to female was 2.1:1(62:30 cases) 2) Chief complaints were a cough (47.8%), dyspnea (40.2%), sputum (38.0%), chest pain (12.0%), anorexia (10.9%), and fever (9.8%). 3) 38 (41.3%) of cases had a past history of pulmonary tuberculosis. 4) The coexisting diseases were : -COPD, 25 cases (27.2%); pneumonia, 17 cases (18.5%); DM. 13 cases (14.1%); and malignancy, 10 cases (10.9%). 5) The positivity of Mantoux test (5 TU, PPD-S) was 82.7%. 6) Pulmonary tuberculosis was diagnosed using the following methods : sputum AFB (Acid Fast Bacillus) smear 42.4%, sputum TB (M. Tuberculosis) culture 15.2%, sputum TB PCR (Polymerase Chain Reaction) 10.9%, bronchial washing AFB smear 2.1%, chest radiology only 25.0%. 7) Locations of radiologic lesions were RULF, 50 cases; RLLF, 50 cases, mostly, then LLLF ; 26 cases were leastly involved. 8) The coexisting tuberculosis were endobronchial TB(8.7%), TB pleurisy(7.6%) miliary TB(5.4%), intestinal TB(2.2%), renal TB(1.1%) 9) The proportion of treatment regimen with 1st line drug and 2nd line drug were 92.3% and 7.6%, respectively. 10) The outcome of treatment were as follows : cured 31.5%, expired 13.0%, no return 47.8%, follow-up now 7.6%. Conclusion : The pulmonary tuberculosis in the elderly has atypical patterns with chronic coexisting diseases. Therefore, the possibility of pulmonary tuberculosis should be considered in elderly patients with pulmonary symptoms.

  • PDF

Four-Channel Differential CMOS Optical Transimpedance Amplifier Arrays for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다 시스템용 4-채널 차동 CMOS 광트랜스 임피던스 증폭기 어레이)

  • Kim, Sang Gyun;Jung, Seung Hwan;Kim, Seung Hoon;Ying, Xiao;Choi, Hanbyul;Hong, Chaerin;Lee, Kyungmin;Eo, Yun Seong;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.9
    • /
    • pp.82-90
    • /
    • 2014
  • In this paper, a couple of 4-channel differential transimpedance amplifier arrays are realized in a standard 0.18um CMOS technology for the applications of linear LADAR(laser detection and ranging) systems. Each array targets 1.25-Gb/s operations, where the current-mode chip consists of current-mirror input stage, a single-to-differential amplifier, and an output buffer. The input stage exploits the local feedback current-mirror configuration for low input resistance and low noise characteristics. Measurements demonstrate that each channel achieves $69-dB{\Omega}$ transimpedance gain, 2.2-GHz bandwidth, 21.5-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -20.5-dBm), and the 4-channel total power dissipation of 147.6-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations. Meanwhile, the voltage-mode chip consists of inverter input stage for low noise characteristics, a single-to-differential amplifier, and an output buffer. Test chips reveal that each channel achieves $73-dB{\Omega}$ transimpedance gain, 1.1-GHz bandwidth, 13.2-pA/sqrt(Hz) average noise current spectral density (corresponding to the optical sensitivity of -22.8-dBm), and the 4-channel total power dissipation of 138.4-mW from a single 1.8-V supply. The measured eye-diagrams confirms wide and clear eye-openings for 1.25-Gb/s operations.

Effects of Active MA Mini-packaging on Shelf-life Maintenance during Marketing of Perilla Leaves (깻잎의 active MA 소포장이 유통기간 중 신선도 유지에 미치는 영향)

  • Jeong, Cheon-Soon;Um, Gi-Jeung;Park, Jong-Nam
    • Horticultural Science & Technology
    • /
    • v.28 no.6
    • /
    • pp.980-984
    • /
    • 2010
  • Research regarding respiration rate, off-flavor related material and freshness maintenance effect of active MA mini-packaging on perilla leaves has been carried in this study. Respiration rate was highly maintained at high oxygen treatments ($CO_2:O_2:N_2$=0:30:70 and 0:50:50), higher than non-treatment and low oxygen treatments (6:2:92, 0:10:90) during the storage period, and ethylene production was relatively higher. However, off-flavor related materials, acetaldehyde and ethanol production was noticeably low. Weight losses of non-treatment and low-oxygen treatment were about 1.8 and 1.4%, respectively. At the fifth day of storage there was no weight loss. Ascorbic acid content was 13.3 mg/100 g F.W. at the first day of storage. At the third day of storage non-treatment showed the lowest value of ascorbic acid, 8.8 mg/100 g F.W. Ascorbic acid content of active MA treatment gradually decreased without a striking difference as the storage day extended. Chlorophyll content was the lowest at the fifth day of storage with non-treatment, 47.5 (SPAD-502 unit) while the active MA treatment maintained high level of chlorophyll content, 53.0. Sensory evaluation (vision) showed that marketability gradually decreased but was maintained in high oxygen treatments (0:30:70 and 0:50:50), even at the fifth day of storage. Occurrence of off-flavor in non-treatment at the fifth day of storage was extremely low, 2.6; whereas high in high oxygen treatment, 3.4. Active MA packaging maintained freshness two more days at room temperature (about $27^{\circ}C$).

AN EXPERIMENTAL STUDY ON THE MICROHARDNESS OF DENTAL AMALGAMS (치과용 아말감의 미세경도에 관한 실험적연구)

  • Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.89-96
    • /
    • 1982
  • The purpose of this study is to identify the phases of four different types, low-copper lathe cut (Type II, class 1) and spherical (Type II, class 2) amalgam alloys which are made by Caulk company and high copper Dispersalloy (Type II, class 3) made by Johnson & Johnson and Tytin (Type I, class 2) made by S.S. White and to determine the Vickers hardness number on the individual phase and four different types of dental amalgam. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (De Trey), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12mm in height and was pressed by the Instron Universal Testing machine (Model 1125) at the speed of 1mm/minute with 143$kg/cm^2$ according to the A.D.A. Specification No. 1. The Specimen removed from the mold, mounted and stored in the room temperature for 7 days. The speciman was polished with the emery paper from #220 to #1200 and finally on the polishing cloth with 0.3 and 0.05 um $Al_2O_3$ powder suspended in water. And then each specimen was etched by Allan's method and washed with Sodium Bisulfinite for 30 seconds. Finally differentiation and metallography on each phase were obtained by using metallographical microscope (Versamet, Union) and microhardness was obtained by using microhardness tester (MVH-2, Torsee). The results were as follows: 1. In the low-copper amalgam, the ${\gamma}$, ${\gamma}_1$ and ${\gamma}_2$ phase were observed and in the high-copper amalgam, the ${\gamma}$, ${\gamma}_1$. ${\epsilon}$ and ${\eta}$ phases were observed but ${\gamma}_2$ phase was not observed. 2. Among the microhardness of each amalgam phase measured under pressing a vickers diamond indenter with 2.0gm load for 30 seconds, e phase has the highest V.H.N (314 ${\pm}$ 20), and in low-copper amalgam 12 phase has the lowest V.H.N. (29${\pm}$1) and ${\eta}$ phase which was observed in high-copper amalgam has 230${\pm}$13 V.H.N and this phase is considerd to contribute to strengthen the handness in amalgam. 3. The V.H.N. measured under pressing a Vickers diamond indenter with 300.0gm load for 30 seconds in low-copper amalgam was lower than that of high-copper amalgam.

  • PDF

ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA (인공타액에서 아말감의 부식거동에 관한 전기화학적 연구)

  • Kim, Yeoung-Nam;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

The Clinical Effectiveness of Atipamezole as a Medetomidine-Tiletamine/Zolazepam Antagonist in Dogs (개에서 Medetomidine-Tiletamine/Zolazepam 마취에 대한 Atipamezole의 길항 효과)

  • Kwon, Young-sam;Joo, Eun-jung;Jang, Kwang-ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.286-293
    • /
    • 2003
  • The cardiopulmonary and antagonistic effects of atipamezole, to medetomidine (30 ug/kg, IM)-tiletamine/zolazepam (10 mg/kg, IV) were determined. Twelve healthy mongrel dogs ,(4.00$\pm$0.53 kg, mean$\pm$SD) were randomly assigned to the four experimental groups (control, A30; atipamezole 30 ug/kg, A60; atipamezole 60 ug/kg, A150; atipamezole 150 ug/kg) with 3 dogs in each group. Atropine (0.03 mg/kg, IM), medetomidine, and tiletamine/zolazepam (TZ) were injected 10 minute intervals. Atipamezole was injected intravenously 15 minutes after TZ injection. Mean arousal time (MAT) was 52.50$\pm$4.98, 43.06$\pm$2.60, 32.83$\pm$8.13, and 14.36$\pm$1.60 minutes in control, A30, A60, and Al50 groups respectively. In Al50 group, MAT was significantly reduced (P < 0.05). but mean walking time (MWT) was similar to that in control group. In recovery period, the higher doses of atimapezole, the rougher recovery including head rocking, hypersalivation, and muscle twitching. Five of twelve dogs vomited within 5 minutes after medetomidine injection. In Control group, heart rate significantly decreased in all recording stages except 15 minutes after TZ injection, 10 minutes after medetomidine injection in all groups, and 40 minutes after atipamezole injection in A30 group (P < 0.05). In Al50 group, atipamezole reversed the respiratory depression induced by medetomidine. Arterial blood pressure was significantly decreased 10minutes after medetomidine injection and 15 minutes after TZ injection in almost dogs in this study (P < 0.05). From 10 minutes after atipamezole injection to arousal time, arterial blood pressure was progressively increased in A60 and A150 group. Any value of blood gas analysis and CBC, and serum chemistry values were not significantly changed except pH of Al50 at 10 minutes after medetomidine injection. As shown in present study, atipamezole(150 ug/kg) is considered to exert a useful reversal effect in dogs anesthetized with medetomidine-tiletamine/zolazepam combination.

Association of p53 Expression with Metabolic Features of Stage I Non-Small Cell Lung Cancer

  • Kang, Shin-Myung;Koh, Won-Jung;Suh, Gee-Young;Chung, Man-Pyo;Han, Joung-Ho;Kim, Ho-Joong;Kwon, O-Jung;Um, Sang-Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.6
    • /
    • pp.417-424
    • /
    • 2011
  • Background: Recent evidences have revealed metabolic functions of p53 in cancer cells; adaptation or survival to metabolic stress and metabolic shift toward oxidative phosphorylation. However, further studies in clinical setting are needed. We investigated whether p53 protein expression, as a surrogate marker for loss of p53 function, is associated with metabolic features of stage I non-small cell lung cancer (NSCLC), focusing on tumor necrosis and maximal standardized uptake value (SUVmax) on $^{18}F$-fluorodeoxyglucose positron emission tomography. Methods: Clinical information was obtained from retrospective review of medical records. p53 expression was assessed by immunohistochemical staining. Results: p53 protein expression was detected in 112 (46%) of 241 NSCLC cases included in this study. p53 expression was independently associated with the presence of necrosis (odds ratio [OR], 2.316; 95% confidence interval [CI], 1.215~4.416; p=0.011). Non-adenocarcinoma histology (OR, 8.049; 95% CI, 4.072~15.911; p<0.001) and poorly differentiation (OR, 6.474; 95% CI, 2.998~13.979; p<0.001) were also independently associated with the presence of necrosis. However, p53 expression was not a significant factor for SUVmax. Conclusion: p53 protein expression is independently associated with the presence of necrosis, but not SUVmax.