• Title/Summary/Keyword: Fluorescence

Search Result 4,371, Processing Time 0.034 seconds

Enhanced Fluorescence from Silk Protein with TiO2 Scatters (산화티타늄 나노 입자에 의한 실크 단백질 형광 증폭 연구)

  • Rakesh Kumar Jha;Sunghwan Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.1
    • /
    • pp.30-34
    • /
    • 2024
  • We report a purely protein-based platform for green fluorescence by mixing silk protein with green fluorescence protein, and also report its enhancement by the incorporation of TiO2 nanoparticles. The TiO2 nanoparticles employed have diameters of 100 and 300 nm, with a significant increase in fluorescence (by a factor of 7.5) observed when introducing 300-nm TiO2 nanoparticles. Furthermore, an increase in particle distribution density is found to enhance fluorescence amplification. These research findings suggest that protein-based fluorescent films can be enhanced by the characteristics of nanoparticles, opening up new possibilities in the fields of optics and fluorescence applications.

Fluorescence Detection of Cell Death in Liver of Mice Treated with Thioacetamide

  • Kang, Jin Seok
    • Toxicological Research
    • /
    • v.34 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study was to detect cell death in the liver of mice treated with thioacetamide (TAA) using fluorescence bioimaging and compare this outcome with that using conventional histopathological examination. At 6 weeks of age, 24 mice were randomly divided into three groups: group 1 (G1), control group; group 2 (G2), fluorescence probe control group; group 3 (G3), TAA-treated group. G3 mice were treated with TAA. Twenty-two hours after TAA treatment, G2 and G3 mice were treated with Annexin-Vivo 750. Fluorescence in vivo bioimaging was performed by fluorescence molecular tomography at two hours after Annexin-Vivo 750 treatment, and fluorescence ex vivo bioimaging of the liver was performed. Liver damage was validated by histopathological examination. In vivo bioimaging showed that the fluorescence intensity was increased in the right upper part of G3 mice compared with that in G2 mice, whereas G1 mice showed no signal. Additionally ex vivo bioimaging showed that the fluorescence intensity was significantly increased in the livers of G3 mice compared with those in G1 or G2 mice (p < 0.05). Histopathological examination of the liver showed no cell death in G1 and G2 mice. However, in G3 mice, there was destruction of hepatocytes and increased cell death. Terminal deoxynucleotidyl transferase dUTP nick end labeling staining confirmed many cell death features in the liver of G3 mice, whereas no pathological findings were observed in the liver of G1 and G2 mice. Taken together, fluorescence bioimaging in this study showed the detection of cell death and made it possible to quantify the level of cell death in male mice. The outcome was correlated with conventional biomedical examination. As it was difficult to differentiate histological location by fluorescent bioimaging, it is necessary to develop specific fluorescent dyes for monitoring hepatic disease progression and to exploit new bioimaging techniques without dye-labeling.

Monitoring of Changes in Molecular Weight Distribution and Fluorescence Properties of Dissolved Matter (DOM) in Water Treatment Processes (정수처리공정 중 자연유기물질의 분자량 분포 및 형광특성 변화 모니터링)

  • Park, Min-Hye;Hur, Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.843-849
    • /
    • 2007
  • Monitoring of NOM characteristics is important for improving removal efficiency of natural organic matter (NOM) in water treatment processes. In this study, several NOM characteristics, which include specific UV absorbance (SUVA), total carbonate content, molecular weight distribution, and fluorescence properties, were measured using samples collected from a pilot-scale water treatment plant consisting of coagulation/flocculation (C/F), filtration, ozonation and granular activated carbon (GAC) processes. The highest removal of NOM was observed in C/F and filtration processes as demonstrated by the reduction of dissolved organic carbon (DOC) by 25% and 21%, respectively. Despite nearly no change in DOC, however, the lowest SUVA value and the highest total carbohydrate content were observed in the sample from ozonation process. This indicates that non-degradable aromatic compounds become depleted and biodegradable organic compounds are enriched during the process. Comparison of synchronous fluorescence spectra of the samples showed that ozoation process increased protein-like fluorescence while it decreased fulvic-like and terrestrial humic-like fluorescence. Consistently, a slight peak of protein-like fluorescence was observed in the sample from ozonation process. The greatest change in molecular weight distributions of the samples was observed in C/F process. Comparison of size exclusion chromatogram of the samples revealed that NOM fractions with the molecular weight greater than 2000 Da were reduced by over 90% after C/F process. SUVA values and total carbohydrate content of the samples were well correlated with a ratio of protein-like fluorescence and terrestrial humic-like fluorescence intensities with the correlation coefficients of 0.99 and 0.91, respectively. This suggests that synchronous fluorescence properties of NOM could be used as useful tolls for monitoring changes of some NOM characteristics during water treatment processes.

Non-destructive identification of fake eggs using fluorescence spectral analysis and hyperspectral imaging

  • Geonwoo, Kim;Ritu, Joshi;Rahul, Joshi;Moon S., Kim;Insuck, Baek;Juntae, Kim;Eun-Sung, Park;Hoonsoo, Lee;Changyeun, Mo;Byoung-Kwan, Cho
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.3
    • /
    • pp.495-510
    • /
    • 2022
  • In this study, fluorescence hyperspectral imaging (FHSI) was used for the rapid, non-destructive detection of fake, manmade eggs from real eggs. To identify fake eggs, protoporphyrin IX (PpIX)-a natural pigment present in real eggshells-was utilized as the main indicator due to its strong fluorescence emission effect. The fluorescence images of real and fake eggs were acquired using a line-scan-based FHSI system, and their fluorescence features were analyzed based on spectroscopic techniques. To improve the detection performance and accuracy, an optimal waveband combination was investigated with analysis of variance (ANOVA), and its fluorescence ratio images (588/645 nm) were created for visualization of the real eggs between two different egg groups. In addition, real and fake eggs were scanned using a one-waveband (645 nm) handheld fluorescence imager that can perform real-time scanning for on-site applications. Then, the results of the two methods were compared with one another. The outcome clearly shows that the newly developed FHSI system and the fluorescence handheld imager were both able to distinguish real eggs from fake eggs. Consequently, FHSI showed a better performance (clearer images) compared to the fluorescence handheld imager, and the outcome provided valuable information about the feasibility of using FHSI imaging with ANOVA for the discrimination of real and fake eggs.

DETECTION OF EARLY PROXIMAL CARIES WITH LASER FLUORESCENCE (레이저 형광법을 이용한 인접면 우식증의 진단)

  • Seol, Jae-Heon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.236-246
    • /
    • 2004
  • Artificial carious lesions in various depths were observed with visual examination using light transillumination, bite-wing radiography, laser fluorescence, and dye-enhanced laser fluorescence to determine the reproducibility, correlation of each diagnostic method, diagnostic sensitivity and diagnostic specificity. And optical densities according to demineralized times were measured whether laser fluorescence could be used as a quantitative diagnostic method. The following results were obtained whether laser fluorescence could be used for diagnosis of initial proximal caries. 1. Tau-c values of visual examination was 0.08 which showed lowest reproducibility and those of bite-wing radiography, laser fluorescence, dye-enhanced laser fluorescence were 0.60, 0.48, and 0.64, respectively which showed relatively high reproducibility. 2. The correlation between demineralization time and each examination was the highest in dye-enhanced laser fluorescence$({\gamma}=0.51)$ followed by laser fluorescence$({\gamma}=0.43)$, bite-wing radiograph$({\gamma}=0.35)$, and visual examination$({\gamma}=0.33)$. Dye-enhanced laser fluorescence and laser fluorescence showed significant correlation with demineralization time. 3. The sensitivity of laser fluorescence and dye-enhanced laser fluorescence for diagnosing approximal caries based on bite-wing radiography were 67%, 100% and those of specificity were 57%, 11% which showed diagnostic specificity was relatively lower than sensitivity. 4. The difference in optical density(DFR) between sound teeth and carious lesions according to lesion depth was high with dye-enhanced laser fluorescence compared with laser fluorescence. DFR measured with laser fluorescence according to changes in lesion depth was statistically significant but was not statistically significant with dye-enhanced laser fluorescence. Based on these results, laser fluorescence and dye-enhanced laser fluorescence have comparable diagnostic power as bite-wing radiography in early diagnosis of proximal caries.

  • PDF

Study on Fluorescence Excitation and Emission Bands for Detection of Fecal Residue on Poultry Carcasses (도계육 표면 내장 잔유물 오염 검사를 위한 형광 조사 및 방출파장 선정에 관한 연구)

  • Cho, B.K.;Kim, M.S.
    • Journal of Biosystems Engineering
    • /
    • v.33 no.2
    • /
    • pp.136-141
    • /
    • 2008
  • Fecal contaminations on poultry carcasses, not easily discemable by human eyes, are potential harbor sites of pathogenic Escherichia Coli (E. coli O157:H7). Development of sensitive detection methods for fecal contamination is essential to ensure safe production of poultry products. Fluorescence has been shown to be very sensitive in detecting fecal and other biological substances that can harbor pathogens. In this study, fluorescence excitation-emission spectra of poultry fecal matter were compared with spectra for poultry skin and meat. Results indicated that the combinations of fluorescence intensities at the wavelength of 520 nm, 579 nm, 625 nm, and 635 nm with 411 nm excitation showed above 97% accuracy for differentiation of the contaminants from poultry tissues. Excitation and emission bands determined could be used for constructing a real-time fluorescence imaging device for detection of harmful residues on poultry carcasses.

Fluorescece Microscope using Total Internal Reflection for Measuring Biochip (내부 전반사 방식에 의한 바이오칩 측정 장비)

  • Bae, Soo-Jin;Kang, Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1694-1698
    • /
    • 2007
  • This study suggests a new fluorescence microscope to observe micro-samples within fluorophore in a variety of biomedical fields including the fluorescence analysis of a biochip, such as a DNA micro-array. A fluorescence microscope is a device for irradiating light onto a micro-object, executing an excitation and fluorescence emission process. In this study, it adopts a total internal reflection fluorescence(TIRF) method to excite a whole micro-sample substrate different from an existing way which uses an evanescent wave resulting from a total internal reflection on the micro-sample surface. Suggested TIRF microscope can reduce optical noise and obtain images with higher sensitivity thus obtain precise information about the density, quantity, location, etc. of a flurophore, and can simultaneously process separate images even when plurality of fluorophores having different excitation and fluorescent wavelength ranges is distributed, thus easily obtain information about the fluorophores.

Monitoring of Biological Processes by 2-dimensional Fluorescence Sensor (2차원 형광센서에 의한 생물공정의 모니터링)

  • 이종일;정상윤;서국화
    • KSBB Journal
    • /
    • v.16 no.5
    • /
    • pp.493-499
    • /
    • 2001
  • This work presented the monitoring technique of biological processes by a 2-dimensional fluorescence sensor. The 2-dimensional fluorescence sensor can be used to monitor some important variable during cultivation processes simultaneously. In this study we have monitored fermentation processes of a few microorganisms such as recombinant E.coli, A. terreus and T. vulgaris. and investigated the change of the fluorescence spectra in the fermentation processes qualitatively. The 2-dimensional fluorescence sensor can be also used to monitor biochemical reactions and separation processes and applied for the optimization of biological processes.

  • PDF

Development and Evaluation of Multi-Wavelength Excitation light Source for Fluorescence Imaging to Diagnose Malignancies (악성종양의 형광영상 진단을 위한 다파장 여기광원장치의 개발과 평가)

  • Lim, Hyun-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.113-121
    • /
    • 2009
  • This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.

Measurement of Electrical Insulating Oil Oxidation by Evaluating the UV Fluorescence Emission Ratio (자외선 형광 방출비 평가에 의한 전기 절연유의 산화측정)

  • Wicaksono, Britantyo;Kong, Hosung;Han, Hung-Gu
    • Tribology and Lubricants
    • /
    • v.29 no.1
    • /
    • pp.51-55
    • /
    • 2013
  • In this work, a new fluorescence emission measurement technology was introduced and experimentally compared with other measurement methods, such as the titration method and IR spectroscopy, to validate it for the oil oxidation measurement of electrical insulating oil. The oxidation characteristics of insulating oil were found to be fairly represented by the titration method and IR spectroscopy, and the results are comparable to a change in the fluorescence emission ratio that is defined as the shift in fluorescence intensity in the measured wavelength range. The result also shows that by the measurement of fluorescence emission ratio, it is possible to detect the oxidation of oil relatively earlier than by other methods. This study suggests that the developed technology can provide sufficient information for evaluating the insulating oil quality, and that the developed FER sensor can be used as an effective condition monitoring device of electrical insulating oil oxidation.