• Title/Summary/Keyword: 힘교정

Search Result 123, Processing Time 0.028 seconds

Variation of Nanoindentation Curve due to Wear of Indenter Apex and Its Correction Method (압입자 첨단마모에 따른 나노압입곡선의 변화 및 이의 보정기법)

  • Lee, Yun-Hee;Kim, Yong-Il;Park, Jong Seo;Kim, Kwang Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.129-137
    • /
    • 2013
  • A force calibration of a nanoindenter and a 3D morphology observation of indenters were carried out in this study. A microbalance calibrated with standard weights was used for measuring the loads generated by a nanoindenter. The indentation load could be calibrated from the ratio of measured and generated loads and the first contact load also could be detected from the microbalance data. By analyzing atomic force microscopy images of two indenters, curvature radii of apexes were determined by $19.71{\pm}3.03$ and $1043.94{\pm}50.91$ nm, respectively, for the nearly new indenter A and the severly worn indenter B. Corresponding bluntness depths were estimated by 1.22 and 64.56 nm for the both indenters by overlapping their profiles on the perfect pyramidal shape. In addition, nanoindentation curves obtained from a fused silica reference material with the both indenters showed a depth difference corresponding to the bluntness depth difference along the indentation depth axis. By shifting amounts of the bluntness depths along the horizontal axis, whole nanoindentation curves overlapped on themselves and resulted in nanohardness values consistent within 1.11 % without considering the complex indenter area function of each indenter.

THREE DIMENTIONAL FORCE ANALYSIS OF FORCE SYSTEM IN CONTINUOUS ARCHWIRE BY FINITE ELEMENT METHOD (CONTINUOUS ARCHWIRE의 FORCE SYSTEM에 대한 3차원 유한 요소법적 연구)

  • Row, Joon;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.17-32
    • /
    • 1996
  • It is important to understand the operating mechanism and force system of fixed appliance that most effective for individual tooth movement in various orthodontic appliances. The archwire system of fixed appliance is devided into 3 types, which is continuous arch, segmented arch and sectional arch. The last two types have longer interbracket distance and simple force operating points, so it is easy to control force system by operator. But the continuous arch has shorter interbracket distance and various bracket geometry, so it is hard to control and anaylze the force system. The purpose of this study was three dimentional force and moment analysis of continuous arch system by finite element method, which is similar situation to three dimentional elastic beam in structural engineering. Several sample form of various bracket geometry and artificial lower crowding typodont made by author were constructed, analyzed and compared each other. The results were as follows : 1. The force magnitude is linear proportional to the degree of displacement or tilting of the bracket. 2. The force magnitude is inversely non-linear proportional to the interbracket distance. 3. In three dimensional typodont model, while the force can be compared with that of the sample form in the area where adjacent bracket geometry is simple, the force is much more than the expected value in the area where adjacent bracket geometry is complex.

  • PDF

Orthodontic Traction of Impacted Tooth (매복된 치아의 교정적 견인을 통한 치험예)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Lee, Ji-Yeon;Kang, Chang-Soo
    • The korean journal of orthodontics
    • /
    • v.28 no.6 s.71
    • /
    • pp.991-999
    • /
    • 1998
  • Tooth impaction may lead to malocclusion, root resolution, cyst or aberrant changes in adjacent teeth. Clinical and radiographic examinations are used to locate the impaction, and appropriate treatment plans must be made to relocate the impacted tooth. When surgically exposing the impacted tooth, periodontal considerations to conserve maximum amount of soft and hard tissue are used. Oral hygiene instructions are emphasized to maintain sound periodontal health. Securing enough space for the impacted tooth and proper anchorage is important. Proper use of force and mechanics is crucial to prevent such complications as root resolution. Various patterns of orthodontic traction may be employed as situation permits. Most impaction cases can be managed with orthodontic traction to restore function and esthetics, provided that early detection and proper diagnosis and treatment planning are made.

  • PDF

An Analytical Study on Strain Distribution Using Strain Gauge Attached On Root Surface (치근 부착 스트레인 게이지를 이용한 응력 분포 분석)

  • Kim, Sang-Cheol;Park, Kyu-Chan
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.325-333
    • /
    • 2001
  • Optimal orthodontic treatment could be possible when a orthodontist can predict and control tooth movement by applying a planned force system to the dentition. The moment to force(M/F) ratio at the bracket, has been shown to be a primary determinate of the pattern of tooth movement. As various n/F ratios are applied to the bracket on the tooth crown, strain distribution in periodontium can be changed, and the center of rotation in tooth movement can be determined. It is, therefore, so important in clinicalorthodontics to know the strain distribution in a force system of a M/F ratio. The purpose of this study was to analyze the strain distribution in orthodontic force system by strain gauge attached to tooth root, and to evaluate the usage of the method. For this study, an experimental upper anterior arch model was constructed, where upper central incisors, on the root surface of which, 8 strain gauges were attached, were implanted In the photoelastic resin, as in the case of 4mm midline diastema. Three types of closing of upper midline diastema closure were compared : 1. with elastomeric chain(100g force) in no arch wire, 2. elastomeric chain in .016“ round steel wire, 3. elastomeric chain in .016”x.022“ rectangular steel wire. The results were as follows. 1. Strain distributions on labial, lingual, mesial and distal root surface of tooth were able to be evaluated with the strain gauge method, and the patterns of tooth rotation were understood by presuming the location of moment arm. 2. Extrusion and tipping movement of tooth was seen in closing in no arch wire, and intrusion and bodily movement was seen with steel arch wire inserted.

  • PDF

Surgically assisted orthodontic treatment of ankylosed maxillary incisor (유착된 상악 절치의 외과적 처치를 동반한 교정 치료)

  • Son, Woo-Sung;Chung, In-Kyo;Shin, Sang-Hoon
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.257-264
    • /
    • 2002
  • If dental ankylosis occurs in maxillary incisors of a growing child, the ankylosed tooth can not move vertically with the subsequent disturbance in vertical growth of the alveolar process. Because ankylosed tooth does not respond orthodontic force, extraction was recommended in the past. But the loss of tooth and accompaning alveolar bone loss incur compromised esthetic situation. And it is very hard to replace by prosthetics. So intentional surgical luxation and orthodontic movement was attempted, but usually this approach is followed by recurrence of the ankylosis. Nowadays the unitooth subapical osteotomy and rapid movement of block bone was reported. Two cases we presented, one is treated by intentional luxation and the other is by unitooth subapical osteotomy following application of light continuous force soon.

Conservative approach for anterior crown-root fractured teeth: forced eruption (상악 전치부 치관-치근 파절 증례에서의 보존적 접근법: 교정적 정출술)

  • Kim, Ji-Eun;Choi, Sung-Hyeon;Chang, Hoon-Sang;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.1
    • /
    • pp.48-54
    • /
    • 2020
  • In the case of crown-root fracture due to traumatic injury in anterior tooth and the fracture margin is located subgingivally, forced eruption has been proposed for the reconstruction of deficient bone and soft tissue. Forced eruption is one of the easiest orthodontic approaches that can have an acceptable outcome and prognosis, and has a low incidence of relapse. However, using heavy forces or very fast movements can also cause tissue damage or ankylosis. The following case reports present forced eruption as treatment option of crown fracture in maxillary anterior teeth.

Foot pressure analysis of laterally & medially wedged rearfoot insole in gait (보행 시 발 뒤축 내/외측 경사진 안창의 족부압력 분석)

  • Chae Byeong-Gi;Im Wan-Su;Ryu Tae-Beom;Choi Hwa-Sun;Jeong Min-Geun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.208-213
    • /
    • 2006
  • 경사진 안창은 안창의 경사로 발의 자세를 교정함으로써 하지 통증을 완화시키는 데 사용되는 보조치료기구로 내측 경사진 안창(MWI: medially wedged insole)과 외측 경사진 안창(LWI: laterlly wedged insole)으로 나뉜다. 본 연구는 내/외측 경사진 안창이 족부압력에 미치는 영향을 정량적으로 분석하고자 한다. 분석변수는 압력중심(COP: center of pressure)의 궤적 변화, 발바닥 내 세 개 구획에 상대적으로 작용하는 수직 힘(RVF: relative vertical force) 그리고 여덟 개 해부학적 지점의 압력이다. 경사진 안창의 경사조건은 내/외측 각각 $5^{\circ},\;8^{\circ},\;15^{\circ}$이며, 경사가 없는 안창을 포함해 총 일곱 가지 안창이 실험에 사용되었다. 실험참여자로는 20대 성인 남성 10명이 참여하였다. 실험결과 앞발 누름기에서 MWI와 LWI는 모두 COP를 내측으로 이동시키고 외측 압력을 감소시켰다. 뒤축 접지기에서 MWI는 COP를 내측으로 이동 시키고 내측압력을 증가시키는 반면, LWI는 COP를 외측으로 이동시키고 외측압력을 증가시켰다. 그리고 RVF 분석결과 MWI와 LWI는 모두 앞발 부위 힘의 크기를 감소시켰고, LWI만이 발 뒤축 부위 힘의 크기를 증가시켰다.

  • PDF

Uncertainty Evaluation of a Multi-axis Force/Moment Sensor and Its Application (다축 힘/모멘트센서의 불확도평가 및 응용에 관한 연구)

  • 김갑순
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.177-180
    • /
    • 2001
  • This paper describes the calibration method and the evaluation method of relative expanded uncertainty for a multi-axis force/moment sensor. This sensor should be calibrated to be use in the industry. Now, the confidence of the calibration result is expressed with interference error. But it is no inaccurate, because an interference error, besides, a reproducibility error of the sensor, a error of this six-axis force/moment sensor calibrator, and so on. Thus, in order to accurately evaluate the relative expanded uncertainty of it, the concept of the uncertainty should be induced, and these errors must be contained in the relative expanded uncertainty. In this paper, the calibration method is exhibited and the evaluation method of the relative expanded uncertainty is also exhibited. And, a six-axis force/moment sensor was calibrated and the relative expanded uncertainty was evaluated.

  • PDF

Exploring the Effect of Qihyul-therapy for Recovery of Qi Circulation in Body (인체에서 기혈(氣穴) 순환 회복을 위한 기혈테라피의 효과 탐색)

  • Kim, Yong Pil;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.8 no.2
    • /
    • pp.63-70
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate whether Qihyul-therapy was effective against subjects of bad Qihyul circulation who had narrowed muscles of the buttocks, a distorted body shape, or pain. Methods: Qihyul-therapy used. Results: The muscles of the buttocks remained almost untouched. The elasticity of the muscles restored. The skin tone brightened, and the anal muscle strengthened after Qihyul-therapy. The subject's body was shifted to the right by -7°. The right arm was about 6 cm longer than the left arm. But after correction, the right arm was about 5 cm shorter. The distorted body was almost balanced. After neck and shoulder correction, the distance between the collarbone and neck was 7~10 cm wider. After the pelvic correction, the pain in the buttocks was relieved, and the position of the hip joint returned correctly. The right leg that was turned 45° to the left was corrected, and the length became the same. Subjects had no knees attached, their right knees were up 5 cm above the left, and their ankles bent at an angle of 30 ° relative to the left, but after correction, the knees of the two legs stably attached. The height of the knee became the normal angle. Conclusion: If the Qihyul-therapy, the spine correction Qihyul-exercise and the pelvic correction Qihyul-exercise performed steadily, the deformed body shape restored adequately, and it is useful to prevent and cure related diseases by alleviating the pains.

Three-dimensional finite element analysis on the effect of maxillary incisor torque (상악 절치부-토크에 의한 치아 이동과 응력 분포에 관한 유한요소법적 연구)

  • Yoon, Hyun-Joo;Lim, Yong-Kyu;Lee, Dong-Yul;Jo, Yung-Soo
    • The korean journal of orthodontics
    • /
    • v.35 no.2 s.109
    • /
    • pp.137-147
    • /
    • 2005
  • The purpose of this study was to investigate the stress distribution in the periodontal tissue and the displacement of teeth when active torque was applied to the maxillary incisors by three-dimensional finite element analysis A three-dimensional finite element model consisted of the maxillary teeth and surrounding periodontal membrane, $.022{\times}.028$ Roth prescription bracket and stainless steel, NiTi and TMA rectangular ideal arch wires which were modeled by hexahedron elements. Applied active torques were 2, 5 and 10 degrees ThHe findings of this study showed that the reaction force acting or the bracket was the extrusion force on the mesial side of the incisors and canine and the intrusion force on the distal side of the incisors and canine. The amount of force and moment was greatest at the lateral incisor. When active anterior labial crown torque was applied. labial crown and distal tipping and Intrusion of the incisors took place. and lingual crown distal tipping and extrusion of the canine occured. An excessive force was concentrated on the lateral incisor, when the stainless steel wire was used NiTi or TMA wire is desirable for torque control.