Neural Network-Based Sensor Fault Diagnosis in the Gas Monitoring System (가스모니터링 시스템에서의 신경회로망 기반 센서고장진단)

  • Lee, In-Soo;Cho, Jung-Hwan;Shim, Chang-Hyun;Lee, Duk-Dong;Jeon, Gi-Joon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • In this paper, we propose neural network-based fault diagnosis method to diagnose of sensor in the gas monitoring system. In the proposed method, using thermal modulation of operating temperature of sensor, the signal patterns are extracted from the voltage of load resistance. Also, ART2 neural network is used for fault isolation. The performance and effectiveness of the proposed ART2 neural network based fault diagnosis method are shown by simulation results using real data obtained from the gas monitoring system.

Experimental Study on the Determination of Heat Transfer Coefficient for the KURT (KURT 내 열전달계수 결정에 관한 실험적 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Kim, Jin
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.507-516
    • /
    • 2009
  • In cases of high-level radioactive waste repositories, heat load is apparent by radioactive waste decay. The safety of a waste repository would be influenced by changing circumstances caused by heat transfer through rock. Thus, a ventilation system is necessary to secure the waste repository. The first priority for building an appropriate ventilation system is completing a computer simulation research with thermal rock properties and a heat transfer coefficient. In this study, the heat transfer coefficient in KURT was calculated using the measurement of inner circumstance factors that include dry bulb and wet bulb temperature, rock surface temperature, and barometric pressure. The heater that is 2 m in length and 5 kw in capacity heats the inside of rock in the research module by $90^{\circ}C$. As a result of determining the heat transfer coefficient in the heating section, the changes of heat transfer coefficient were found to be a maximum of 7.9%. The average heat transfer coefficient is approximately 4.533 w/$m^2{\cdot}K$.

A study on the Temperature Control of Insulated Open-End Water Vessel (밑이 트인 단열수조의 온도제어에 관한 연구)

  • Han, Seung-Hun;Bae, Cherl-O;Ahn, Byong-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1097-1103
    • /
    • 2012
  • There are many fish farms being cultivated in the southwestern cost of South Korea. Because the farms cultivating use the basic method that inflow and circulate sea-water, slight negligence and bad design cause major negative impact on fish deaths. Also, the optimal temperature for each specie of fishes has already been proven to differ on each specie. Maintaining this environment, regardless of seasons, is very difficult and that requires research to develop. In this paper, basic characteristics of heat and mechanism of heat transfer are studied. Based on this, Open-end water vessel is designed and constructed using sandwich-insulation panels and simulated to store the heat in certain isolated space. This study confirmed that it is possible to keep constant temperature by this method, in large areas of water where it is insulated by heat insulator. and equipped with heater in Open-end water vessel where the other part is heated. The AC power controller maintains the constant temperature required and the temperature controller detects and displays the temperature by using the micro-processor.

A Study on the Optimum Design of Warm-up rate in a Air-Heated Heater System by Using CFD Analysis and Taguchi Method (전산유체해석과 다구찌 방법을 연계한 공기 가열식 히터 시스템의 난방속효성 최적화에 관한 연구)

  • Kim, Min-Ho
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.72-82
    • /
    • 2005
  • The objective of this paper is to describe the optimization of design parameters in a large-sized commercial bus heater system by using CFD(computational fluid dynamics) analysis and Taguchi method. In order to obtain the best combination of each control factor which results in a desired performance of heater system, the parameter design of the Taguchi method is adopted for the robust design considering the dynamic characteristic. The research activity may be divided into four phases. The first one is analyzing the problem, i.e., ascertaining the influential factors. In the second phase the levels were set in such a way that their variation would significantly influence the response. In the third phase the experimental runs were designed. In the final phase the planned runs were carried out numerically to evaluate the optimal combination of factors which is able to provide the best response. In this study, eight factors were considered for the analysis: one with two level and seven with three level combinations comprising the $L_{18}(2^1{\times}3^7)$ orthogonal array. The results of this study can be summarized as follows ; (i)The optimum condition of control factor is a set of <$A_2\;B_1\;C_3\;D_3\;E_1\;F_2\;G_3\;H_2$> where A is shape of the outer fin, B is pitch of the outer fin, C is height of the outer fin, D is the inner fin number, E is the inner fin height, F is length of the flame guide, G is diameter of the heating element and H is clearance between air guide and heating element. (ii)The heat capacity of heated discharge air under the optimum condition satisfies the equation y=0.6M w here M is a signal factor. (iii)The warm-up rate improves about three times, more largely as com pared with the current condition, which results in about 9.2minutes reduction.

Reduction of Temperature Variation at Measurement Points of Semiconductor Test Handler (반도체 테스트 핸들러 측정점간의 온도 편차 감소)

  • Kim, Jae-Yong;Cho, Su-Young;Kang, Tae-Sam;Lee, Ho-Joon;Koh, Kwang-Ill
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.77-84
    • /
    • 1998
  • The temperature difference occurs at the test points of chamber, because the traditional Test Handler consists of a heater and a fan. To reduce the temperature variation at different points in the chamber, we divided the heater to three parts which are controlled independently. First, we identified the chamber's parameter and then designed a LQG controllers by the identification model. RTD sensors and VME system were used to construct the temperature control system. In our experiment for the proposed control system, the temperature variation was reduced from ${\pm}1.5^{\circ}C$ to ${\pm}0.35^{\circ}C$ at 50$^{\circ}C$ ${\cdot}$ 80$^{\circ}C$ and 120$^{\circ}C$.

  • PDF

성막직전 기판 열처리가 롤투롤 스퍼터를 이용하여 성장시킨 터치 패널용 ITO 투명 전극의 특성 미치는 효과 연구

  • Kim, Dong-Ju;Kim, Bong-Seok;Kim, Han-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.416-416
    • /
    • 2010
  • 본 연구에서는 저가격, 대면적화를 위한 롤투롤 스퍼터를 설계&개발하고, 성막직전 PET 기판의 열처리 유무를 통한 ITO 박막을 성막 시킨 저항막 방식의 터치 패널용 투명 전극에 대하여 전기적, 광학적, 구조적, 표면적 특성을 분석하였다. 롤투롤 스퍼터는 degassing챔버와 스퍼터 챔버가 한 시스템에 구성되었고, Degassing 챔버는 좌우측의 Rewinder/Unwinder 롤러에 의해 감고 풀어지는 PET기판의 수분 및 가스를 중앙부에 위치한 히터를 통해 제거하며, 수분 제거 후 스퍼터 챔버로 옮겨진 1250 mm폭의 PET기판을 Unwinder/Rewinder 롤러에 장착하며, Unwinder 롤러로부터 풀려진 PET 기판은 guide 롤러를 거쳐 cooling drum과의 물리적 접촉에 의해 PET 기판의 냉각이 일어나게 된다. ITO 캐소드 전에 장착된 할로겐 히터 상부로 기판이 지나가면서 열처리가 진행되고 열처리 후 두 개의 ITO 캐소드 상부를 지나면서 연속적으로 ITO 박막이 PET 기판에 성막 되게 된다. ITO 박막의 주요 성막 변수인 DC Power, Ar/$O_2$ 가스 유량비, 기판의 속도는 최적으로 고정하고, 성막 직전 기판의 열처리에 유무에 따른 ITO박막의 필름을 각각 고온 챔버에서 $140^{\circ}C{\times}90min$ 동안 열처리를 통한 내열성 테스트를 진행하여 ITO 필름의 특성 향상을 비교 분석하였다. 분석을 위해 전기적 특성은 four-point probe로 측정했고, 투과도는 Nippon Denshoku사(社)의 COH-300A를 이용해 가시광(550nm)에서 분석했고, FE-SEM으로 ITO박막 의 표면 상태를 분석하였다. 또한 Bending Tester(Z-100)를 이용하여 기계적 안정성을 분석하였다. 성막직전 PET 기판의 열처리를 하지 않은 ITO박막은 고온의 챔버 에서 $140^{\circ}C{\times}90min$ 동안 내열성 테스트 후 면저항이 511($\omega/\Box$)에서 630($\omega/\Box$)으로 높아졌으나, 성막직전 열처리를 통한 ITO 박막인 경우에는 465($\omega/\Box$)에서 448($\omega/\Box$)로 안정화 되었고, 투과율은 성막직전 열처리를 통해 1%향상되어 89%를 보였고, 유연성 또한 보다 우수한 특성을 보였다. 표면 조도는 평균 0.416 nm의 낮은 값을 보였다. 이는 PET 기판의 degassing 공정 중 충분히 제거되지 않은 가스나 불순물을 성막직전 열처리 공정으로 충분히 제거하여 깨끗한 PET 기판 상에 ITO 박막을 성막시키고, 열처리시 기판에 주어진 열에너지에 의해 보다 밀도가 높은 ITO 박막이 성장했기 때문으로 사료 된다.

  • PDF

Development of Digital Solder Station Based on PID Controller (PID 제어기를 이용한 전기인두기의 온도 제어 시스템 개발)

  • Oh, Kab-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.866-872
    • /
    • 2010
  • In this paper, we developed a digital soldering station based on PID controller, which supply stable power by controlling the current of heater of soldering iron. The proposed system designed PID controller to converge quickly to the set up temperature by user, and regain the lost of heat by external factors quickly. PID controller, designed by Ziegler-Nichols' tuning method, decides triac's trigger timing using setting temperature and present temperature to control the phase of AC 24V power that supply to the heater. Also, we give the function that shows present temperature and setting temperature of iron, and working time by graphic LCD. And during the rest time, we decided the power saving and extension of iron tip by dropping to the optimal temperature. Two experiments had implemented in $25^{\circ}C$ laboratory to confirm the performance of proposed method. The first experiment took 12sec, 13sec, 16sec, 18sec, reaching to $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ respectively which result showed shorten of rising time than previous method. In the loading experiment of $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ steady state showed temperature drop of $3.8^{\circ}C$, $4.1^{\circ}C$, $4.5^{\circ}C$ which result showed the low temperature deviation than previous method.

Implementation of The Drug Infuser with Active Pressure Control Method (능동적 압력조절이 가능한 약물주입기 구현)

  • Cho, Seong-Beom;Noh, Yun-Hong;Moon, Chang-Su;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.817-818
    • /
    • 2012
  • 본 연구에서는 치과에서 마취 시 환자들의 고통을 최소화 하기위하여 무통마취를 위한 치과용 약물주입기를 구현하였다. 약물의 주입 시 통증을 최소화하기 위해서 온도를 $36{\pm}2^{\circ}C$ 범위로 제어하여 체온과 유사한 온도로 유지하였다. 이를 위하여 필름히터 방식을 이용한 치과범용국소약물(36mg, 2% 리도카인) 앰플 가열부를 설계하였다. 또한 약물이 주입되는 양을 능동적으로 제어하기 위하여 약물주입 환부의 환자별 흡수 속도 차이에 차등 주입을 위한 압력 측정 시스템을 구현하였다. 필름 형태의 압력 센서를 통하여 전달 압력을 측정하였으며 측정된 압력을 바탕으로 능동적으로 모터의 동작을 제어함으로써 약물주입시 환자의 고통을 최소화 할 수 있도록 구현하고자 하였다.

  • PDF

Protection of the Inverter for Electric Vehicles (전기자동차용 인버터의 보호기능)

  • Jun, Bum-su;Lee, Jae-shin;Kim, Ung-hoe;Kim, Hyoung-taek;Won, Chung-yuen
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.227-228
    • /
    • 2011
  • EV의 중요한 부품은 MCU(인버터), BMS(고전압), LCD(저전압 충전장치), OBC(완속충전장치), EWP(냉각장치), PTC(히터), A/C(에어컨) 등으로 구성되어 있으며, 특히 EV용 인버터의 경우 핵심 부품으로 신뢰성 및 보호기능에 대한 중요성이 인식되고 있다. EV 인버터는 온도(인버터, 모터), 단락과 단선, 인터락 및 최대출력제한 등에 대한 보호기능 구현이 되어 있으며, 고장발생시 고장을 진단할 수 있는 기능(DTC)이 구현되어 있다. 이러한 보호기능 중에 단락과 단선 시 인버터의 보호는 중요한 요소이며, 이를 구현하기 위한 회로설계 및 회로분석이 필요하다. 본 논문에서는 EV용 인버터에 사용되는 병렬 운전형 인버터의 단락 및 단선 시 시스템을 보호할 수 있는 드라이버 회로 설계 및 분석을 수행하며, 실험을 통해 그 결과를 검증한다.

  • PDF

Anti-condensation System for Switchboard sing the ATmega128 (ATmega128을 이용한 배전반의 결로 방지 시스템 구현)

  • Youn, Jung-Ho;Oh, Kab-Suk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.329-331
    • /
    • 2010
  • 전력회사로부터 공급되는 전력을 분배하고 제어하는 기능을 갖는 배전반은 아파트를 비롯한 대단위 인구밀집 주택 지역과 고압 변전소 등에 설치된다. 배전반에 수용되는 전력설비의 사고는 전력 기기의 열화에 의한 사고, 접점 및 각 연결 부위의 접촉 불량에 의한 과열 현상 등에 의한 사고 등으로 구분할 수 있으며 과열 현상에 의한 사고의 원인 중의 하나는 배전반 천정면의 결로에 의한 것으로, 물방울이 각종 기기에 직접 접촉하여 폭발하는 사고로 연결된다. 배전반의 결로는 일중 온도가 급격한 변화를 보이는 계절이나 지역에서 배전반 내부와 외부의 온도 차이와 내부 습도에 의해 발생한다. 본 논문에서는 온도와 습도의 단순 비교를 통하여 환풍기, 열풍기, 환기 등을 제어하여 결로를 해결하는 기존의 방식을 개선하여, 노점온도 계산에 의한 히터 구동 방안을 제시한다.

  • PDF