• 제목/요약/키워드: 희박분무

검색결과 35건 처리시간 0.021초

희박 분무영역에서의 분무냉각 막비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1481-1486
    • /
    • 2004
  • This report presents experimental results on the heat transfer coefficients in the boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distribution of a two dimensional dilute spray impinging on hot plate was experimentally investigated. Based on the experimental results, they classified the heat transfer area into the stagnation region and wall-flow region. In the stagnation region, the local heat transfer coefficient relates mainly to the droplet-flow-rate supplied from spray nozzle directly, so the local heat transfer coefficients is good agreement with the predicted values from correlation for spray cooling proposed by former report However, the local heat transfer coefficient in wall-flow region is larger than predicted values, and it is found that the rebounding droplets-flow-rate must be accurately evaluated to predict the local heat transfer coefficient in this region.

  • PDF

희박 분무영역에서의 분무냉각 막 비등 열전달에 관한 연구 (Study on Film Boiling Heat Transfer of Spray Cooling in Dilute Spray Region)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.279-286
    • /
    • 2005
  • This study presents experimental results on the heat transfer coefficients in the film boiling region of spray cooling for actual metallurgical process. In this study, the heat flux distributions of a two dimensional dilute spray impinging on a hot plate were experimentally investigated. A stainless steel block was cooled down from intial temperature of about $800^{\circ}C$ by twin fluid (air-water) flat spray. It was found from the experimental results that the heat transfer area was classified into the stagnation region and wall-flow region. In the stagnation region, the experimental data of local heat transfer coefficient was closely correlated with the local droplet-flow-rate supplied from the spray nozzle directly. Thus, the local heat transfer coefficients are in good agreement with the predicted values from the correlations proposed by our previous study. In wall-flow region, however, remarkable differences are observed between experimental data and predicted values because the number of rebound droplets increase with increasing the distance from the stagnation point.

액적의 리바운드 모션에 주목한 분무냉각 막비등 열전달 모델 (Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1317-1322
    • /
    • 2004
  • In this report, the heat transfer model of spray cooling on hot surface was developed by focusing on the effect of rebound motion of droplets. In the model, it was assumed that droplets rebound repeatedly on the hot surface and heat transfer upon droplet impact is proportional to sensible heat which heats up the droplets to the saturation temperature. In addition, to take account of the contribution of th heat flux upon impact of rebound droplets, it was assumed that the rebound droplets are distributed following the Gaussian distribution from 0 to L, which distance L is determined by maximum flight distance $L_{max}$. Also the calculated results were compared with existing experimental results.

  • PDF

액적의 리바운드 모션에 주목한 분무냉각 막 비등 열전달 모델 (Film Boiling Heat Transfer Model of Spray Cooling Focusing on Rebound Motion of Droplets)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.287-293
    • /
    • 2005
  • In the present study, to determine the flow rate of droplets supplied to heat transfer surface after (j-1)th rebound, $D_X[j{\ge}2]^{\ast}$, it was assumed that the rebound droplets are distributed according to the Gaussian distribution from 0 to L, in which the flight distance L is determined by maximum flight distance $L_{max}$. We also assumed that $L_{max}$ is dependent on the air flow velocity and mean size of droplets. The local heat flux of a dilute spray in high temperature region was predicted using the newly evaluated $D_X[j{\ge}2]^{\ast}$. In addition, the predicted results by the present model were compared with the existing experimental data.

희박 예혼합 연소기에서 연료 조성이 화염전달함수 특성에 미치는 영향 (Effects of Fuel Composition on Flame Transfer Function in Lean Premixed Combustor)

  • 김진아;김지환;이정원;김대식
    • 한국분무공학회지
    • /
    • 제20권3호
    • /
    • pp.135-140
    • /
    • 2015
  • Flame transfer function is used to determine the relationship between flow fluctuations and heat release perturbations in a lean premixed gas turbine combustor. The characteristics of flame transfer function are known to depend greatly on flame geometries in addition to other various flow conditions. However, it is not easy to experimentally measure the flame transfer function under various actual combustor operating conditions in terms of time and cost. The current research tries to model the flame transfer function using CFD(Computational Fluid Dynamics). From the results, it is shown that the calculated steady flame geometry can be exactly captured with consideration of the wall heat transfer and radiations. Also, unsteady analysis results show the close characteristics of the flame transfer function to the measured one in both gain and phase.

스파크점화 엔진에서 천연가스와 수소의 희박연소 성능 비교 (Comparison of Lean Combustion Performance in a Spark-Ignition Engine Fueled with Natural Gas and Hydrogen)

  • 박현욱;이준순;오승묵;김창업;이용규;강건용
    • 한국분무공학회지
    • /
    • 제26권4호
    • /
    • pp.204-211
    • /
    • 2021
  • Lean combustion performance of natural gas and hydrogen was compared in a spark-ignition engine. The lean combustion engine operation with natural gas was limited due to combustion instability at an excess air ratio (EAR) above 1.8. The total hydrocarbon (THC) emissions increased significantly with increasing EAR. The nitrogen oxides (NOX) emissions were also high due to the limitation of increasing EAR. The lean combustion engine operation with hydrogen showed superior combustion stability as well as low THC and NOX emissions, even at high EARs. However, boosting technology was required to reach the high EARs.

전기장 인가에 따른 프로판 예혼합 화염의 희박연소 특성 (Lean Burn Combustion Characteristics of Propane Premixed Flame in Electric Field)

  • 김민석;최준영;김태훈;김혜민
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.24-31
    • /
    • 2023
  • In this study, characteristics of a propane-air premixed flame sin DC electric field was investigated. The stainless steel Bunsen burner and the stainless steel ring were used as electrode, and the high voltage supply was used for applying electric field. Flammability range increased significantly when the positive voltage was applied because of extension of LBO limit, while it shrank when the negative voltage was applied. The reason for this was not much related to the burning velocity, but the induced flow around the burner by electric field. withNOx production slightly increased after positive voltage was applied in identical equivalence ratio. Nevertheless, it was advantageous to apply the positive electric field to reduce the NOx since the extension of LBO limit makes the burner possible to operate in very low equivalence ratio.

예막 공기충돌형 분사기의 벤추리 덤프면 설계 (Design of Venturi Dump Surface for Pre-filming Airblast Injector)

  • 신동수;최명환;;구자예;정승채
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.44-54
    • /
    • 2018
  • 예막 공기충돌형 방식의 희박 예혼합 예증발(LPP) 보조 분사기에 벤추리를 장착하여 분무 실험을 할 경우 액적의 낙수현상이 나타나며, 이는 액적의 불균일한 분포로 나타난다. 이를 해결하기 위해 벤추리의 출구 각도를 변화시켜 노즐목 부분에서 덤프면을 형성시켰다. 덤프면의 형성은 벤추리 출구에 재순환영역을 형성시키면서 미립화 성능을 개선하며 액적 낙수를 최소화하였다. 분사기의 불균일한 분무를 해결하기 위해 벤추리 내부의 유동 특성 및 분무의 SMD를 비교분석하였으며, 최종적으로 분무의 손실을 최소로 하며 분무를 향상시킬 수 있는 최적의 벤추리의 형상을 선정하였다.

뉴스와 토픽

  • 한국과학기술단체총연합회
    • 과학과기술
    • /
    • 제35권7호통권398호
    • /
    • pp.6-9
    • /
    • 2002
  • 간 커피에서 배터리 재료 추출/편두통의 원인 밝혀져/세계의 산호초가 파괴되고 있다/초고속의 기상 예보용 슈퍼컴퓨터/바르는 발기부전 치료제/설탕으로 오염물질 제거/화성 지하에 거대 얼음층/목성의 위성에 생명체 존재 가능성 희박/목성에서 위성 11개 새로 발견/22번째 아미노산 발견/플라스틱 분무로 식물해충 제거/외계 물체가 공룡의 멸종은 물론 번성과도 관련

  • PDF

연소제어인자의 변화에 따른 직접분사식 초희박 LPG엔진의 연소특성 연구 (Study of Combustion Characteristics with Variations of Combustion Parameter in Ultra-Lean LPG Direct Injection Engine)

  • 박윤서;박철웅;오승묵;김태영;최영;이용규
    • 대한기계학회논문집B
    • /
    • 제37권6호
    • /
    • pp.607-614
    • /
    • 2013
  • 오늘날 전 세계의 자동차 회사들은 연비를 향상시키고 배기가스를 저감시키기 위해 다양한 기술을 개발하고 있다. 그 중 직접분사식 초희박 연소기술은 연료제어의 정확도를 향상시켜 연소 효율을 극대화하고 초희박 연소를 통해 연비를 향상 시킬 수 있는 차세대 기술로 평가받고 있다. 따라서 기존 가스엔진에 초희박 직접분사 기술을 적용한 초희박 LPG 직접분사 엔진을 개발하기 위해 $2{\ell}$ 급 MPI 엔진을 베이스 엔진으로 실린더 헤드를 재설계하였다. 재설계된 헤드는 초희박 연소를 구현하기 위해 인젝터와 점화플러그가 헤드 중앙에 장착되는 분무유도방식 연소시스템을 적용하였다. 연료 분사 압력별 연료 분사 시기와 점화 시기의 변경을 통해 연료 소비율과 연소 안정성을 측정하였으며 이를 통해 최적연료 분사시기와 점화시기를 선정하였다.