• 제목/요약/키워드: 흡수질량유속

검색결과 4건 처리시간 0.016초

수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향 (Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

수직형 흡수기내 열 및 물질 전달 특성 (Heat and mass transfer characteristics in a vertical absorber)

  • 서정훈;조금남;최기봉
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.835-845
    • /
    • 1999
  • The objective of the present study was to investigate heat and mass transfer characteristics in a vertical falling film type absorber using LiBr-$H_2O$ solution with 6owt%. The experimental apparatus consisted of an absorber with inner diameter of 17.2 mm and length of 1150mm, a generator, an evaporator/condenser, a solution tank, a sampling trap etc. The parameters were solution temperature of 45 and $50^{\circ}C$, coolant temperature of 30 and $35^{\circ}C$, and film Reynolds numbers from 50 to 150. Pressure drop in the absorber increased as solution and coolant temperatures decreased. Pressure drop in the absorber increased up to the film Reynolds number of 90, and then decreased at the further increase of the Reynolds number above 90. The maximum absorption mass flux observed at the film Reynolds number of 90. Absorption mass flukes increased as coolant temperature decreased. Absorption mass fluxes and heat transfer coefficients under subcooled condition were larger than those under superheated condition. Heat transfer coefficients were affected by solution temperature more than coolant temperature. The maximum absorption effectiveness under the subcooled condition was 23% for coolant temperature of $30^{\circ}C$ and 31% for coolant temperature of $35^{\circ}C$ under the present experimental conditions.

  • PDF

다채널 체적식 태양열 흡수기에서 열전달 수치해석 (Numerical Analysis of Heat Transfer in Multichannel Volumetric Solar Receivers)

  • 이현진;김종규;이상남;강용혁
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1383-1389
    • /
    • 2011
  • 본 연구는 태양열 발전에 사용하는 공기식 다채널 체적식 흡수기의 일관성 있는 열전달 해석에 초점을 두고 있다. 이를 위해 흡수 소재 물성과 채널 형상 변화의 영향을 몬테카를로 광선추적법에 기반한 광학 모델과 전도, 대류, 복사를 고려한 1 차원 열전달 모델에 동시에 반영하였다. 광학 모델 결과는 채널 반경 대비 길이의 형상비가 매우 커서 대부분의 태양 에너지는 15 mm 이내의 짧은 길이에서 흡수됨을 증명하고 있다. 복사 열손실 분류를 통해 채널의 낮은 흡수율에서는 방사 손실은 줄지만 반사손실이 증가하여 흡수기 효율이 감소하는 것을 보였다. 큰 채널 반경이나 작은 질량 유량으로 인해 흡수기 평균 온도가 상승할 때, 방사 손실과 반사 손실 모두 증가하지만 방사 손실의 영향이 더 큰 것으로 나타났다.

輻射가 關與하는 氣體-固體粒子 캐비티 流動에서의 熱傳達 (Heat Transfer in Radiatively Participating Gas-Particle Cavity Flows)

  • 이종욱;이준식;이택식
    • 대한기계학회논문집
    • /
    • 제12권3호
    • /
    • pp.551-560
    • /
    • 1988
  • 본 연구에서는 해석하려는 시스템의 유동 및 열전달 현상의 개념도를 Fig.1 에 나타내었다. 고체 입자는 윗부분 홈으로부터 분사되어, 선택적 투과면을 통해서 입사되는 복사열을 흡수 하며, 기체는 아래 또는 위의 홈 부분으로부터 들어와서 고체 입자와의 대류열전달로 가열이 된다. 기차게 아래 홈에서부터 분사되는 경우 대류에 의해 가열된 기체가 역성층화로 인해 부력을 받게 되어, 고체 입자의 하강 속도가 감 소할 때 입자의 체류 시간의 증가에 따른 복사열의 흡수효과에 대하여 고찰하였으며 입자의 크기, 투사 복사량, 분사속도, 입자의 질량유량 등을 파라미터로 하여 이들의 변화에 따른 영향을 규명하였다. 2-방연계를 고려한 2-방정식 모델을 구성하고 고체 입자에 대하여는 Lagrangian 방법으로 기술하였으며 수치해석에 있어 유한차분법을 도 입하고 두 상간의 상호연계는 PSI-Cell 방법을 이용하였고 복사 열유속은 2-유속 모델 (two-flux model)을 도입하여 계산하였다.