• Title/Summary/Keyword: 흡수식 시스템

Search Result 177, Processing Time 0.033 seconds

Numerical Study of Concentration Characteristics of Linear Fresnel Reflector System (선형 프레넬 반사판 시스템의 집광 특성에 대한 수치해석 연구)

  • Lee, Hyun Jin;Kim, Jong Kyu;Lee, Sang Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.927-934
    • /
    • 2015
  • In this study, we numerically investigated the concentration characteristics of a linear Fresnel reflector system that can drive a solar thermal absorption refrigeration system to be installed in Saudi Arabia. Using an optical modeling program based on the Monte Carlo ray-tracing method, we simulated the concentrated solar flux, concentration efficiency, and concentrated solar energy on four representative days of the year - the vernal equinox, summer solstice, autumnal equinox, and winter solstice. Except the winter solstice, the concentrations were approximately steady from 9 AM to 15 PM, and the concentration efficiencies exceed 70%. Moreover, the maximum solar flux around the solar receiver center changes only within the range of $13.0{\sim}14.6kW/m^2$. When we investigated the effects of the receiver installation height, reflector width, and reflector gap, the optimal receiver installation height was found to be 5 m. A smaller reflector width had a greater concentration efficiency. However, the design of the reflector width should be based on the capacity of the refrigeration system because it dominantly affects the concentrated solar energy. The present study was an essential prerequisite for thermal analyses of the solar receiver. Thus, an optical-thermal integration study in the future will assist with the performance prediction and design of the entire system.

반도체 및 Optic Industries 클린룸 배기가스의 오염제어 및 청정화기술

  • 황유성
    • Air Cleaning Technology
    • /
    • v.17 no.4 s.67
    • /
    • pp.39-57
    • /
    • 2004
  • 첨단산업으로 불리는 반도체, LCD, PDP, 유기EL(OLED) 등의 생산 공정은 고도의 청정상태를 요구하며, 때문에 이들의 생산공정 중 대부분이 클린룸 내에서 이루어진다. 클린룸 내에서의 주요공정은 크게 박막형성(Layering), 노광(Photo Lithography), 식각(Etching) 등 3가지 공정으로 나눌 수 있으며, 반도체 제조공정의 경우 특별히 도핑(Doping) 공정이 추가된다. 오염물질을 함유하는 클린룸 배기는 일반적으로 산, 알칼리, Toxic(PFCs, Flammable), VOC 등으로 분류하며, 각각의 배기는 각 배기특성에 맞는 오염제어 장치를 통해, 정화된 후, 대기로 방출된다. 산, 알칼리 배기는 일반적으로 최종 단계에서 중앙집중식 습식스크러버에 의해 흡수, 중화 처리되며, VOC의 경우 농축기(Concentrator) & 축열식 열 산화장치(RTO) 설비에 의해 연소 처리된다. 하지만 CVD공정으로부터의 배기가 주를 이루는 Toxic배기의 경우, 다량의 PFCs(과불소화합물) 가스를 함유하고 있는 이유로, 대부분 클린룸 내부에 P.O.U(Point of use) 처리장치가 설치되며, P.O.U에 의해 1차 처리된 후 최종적으로 중앙집중식 습식스크러버를 거쳐 대기로 방출된다. 알칼리배기의 주성분으로는 암모니아($NH_3$), HMDS (Hexa Methyl DiSilazane), TMAH (Tetra Methyl Ammonium Hydroxide), LGL, CD 등이며 흡수액에 황산(Sulfuric Acid)용액을 공급, 중화처리하고 있다. 탄소성분을 먹이로 하는 미생물의 번식에 의한 막힘 문제를 제외하고는 큰 문제가 없다. 하지만 Toxic배기 및 산배기의 경우 처리효율이, 가스흡수 이론에 의한 계산결과와 비교할 때, 매우 저조하게 나타나는 효율부족 현상을 겪고 있으며, 이는 잔여 PFCs 가스성분 및 반응에어로졸, 응축에어로졸 등의 영향으로 추정하고 있다. 최근 Toxic 배기의 경우, P.O.U 설비를 Burn & Wet type으로 변경하여, 배기 중 PFCs 및 반응에 에어로졸($SiO_2$)의 농도를 원천적으로 감소시키는 노력이 진행 중이다. 산배기의 경우, 산결로 현상에 의한, 응축에어로졸이 문제가 되고 있으나 내식열교환기(Anti-Corrosive Heat Exchanger), 하전액적스크러버 시스템(Charged Droplets Scrubber System), Wet ESP(Wet Electrostatic Procipitator) 등의 도입을 통해 문제해결을 위한 노력을 경주하고 있다.

  • PDF

The Characteristics of Cooling Performance on 7RT Ammonia Absorption System (7RT급 암모니아 흡수식 냉온수기의 냉방성능 특성)

  • Lee, Ho-Saeng;Jin, Byoung-Ju;Yoon, Jung-In;Hwang, Jun-Hyeon;Jin, Slm-Won;Kyung, Ick-Soo;Erickson, Donald C
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.433-438
    • /
    • 2009
  • Experimental results for performance characteristics of small $NH_3$ absorption chiller/ heater are presented. The apparatus consists of 7RT water-cooled absorption system, solution pump, boiler, cooling tower and peripheral devices. The effect of experimental parameters, such as refrigerant mass flow rate, solution mass flow rate and cooling water temperature have been investigated in view of the system performance. The capacity of each heat exchanger increased as refrigerant mass flow rate increased in cooling mode. Also, a cooling capacity increased as a strong solution mass flow rate increased. The cooling and heating COP show 0.5, 1.5 regardless of refrigerant mass flow rate, respectively. The results focus on the evaluation for performance characteristics of system with respect to variation of refrigerant mass flow rate under standard design conditions.

Development of a Compression/Absorption Hybrid Heat Pump System Using $NH_3/H_2O$ Mixture for High Temperature Generation ($NH_3/H_2O$를 이용한 압축-흡수식 고온제조 하이브리드 히트펌프 시스템 개발)

  • Kim, Min-Sung;Baik, Young-Jin;Shin, Kwang-Ho;Park, Seong-Ryong;Chang, Ki-Chang;Lee, Young-Soo;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1249-1254
    • /
    • 2008
  • Industrial low temperature waste heat exists sparse in surroundings but its amount is huge. However, large portion of waste heat is discarded due to its poor recovery quality and inferior application technologies. The heat pump system in this research is based on the hybrid combination of compression cycle and absorption cycle in order to recycle various kind of industrial waste heat effectively. The prime objective is to design a compression absorption hybrid heat pump system which can produce high temperature above the level of $90^{\circ}C$ and low temperature of $20^{\circ}C$ at the same time using waste heat water of $50^{\circ}C$. A mathematical simulation was carried out as a basis to design a prototype 3 RT class hybrid heat pump. From the simulation results, fundamental parameters to design the system were obtained.

  • PDF

Development of High Efficiency Cycle by Combining Double-Effect with Single-Effect Absorption Chiller Systems (이중 효용과 일중 효용을 복합한 다단 재생 고효율 흡수식 냉동 사이클 개발)

  • Yun, Sang Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.360-365
    • /
    • 2017
  • Recently, development efforts of triple-effect absorption chiller have been increased in order to improve the efficiency of double-effect absorption chiller. However, triple-effect absorption chiller has some disadvantages, including high corrosion characteristic of LiBr solution at high temperature of $200^{\circ}C$. Moreover, it is necessary to develop new components for operation under high pressure of 2 bars even though COP is increased to 1.6 or 1.7. The objective of this study was to introduce a new system by combining double effect absorption chiller with single effect absorption chiller with multi-generators using bypass flow of LiBr dilute solution to $3^{rd}$ generator to overcome the disadvantages of triple-effect chiller and improve energy efficiency. Results indicate that the new absorption cycle had a much higher efficiency than double-effect chiller system, showing significant improvement when bypass solution flow rate of 25% was applied to the $3^{rd}$ generator using the main dilute solution of the absorber. The COP of the new chiller system was found to be 1.438, which was 21.7% higher than that (1.18) of the present double-effect system. The COP was decreased when solution by-pass rate to the $3^{rd}$ generator was increased. In addition, lower cooling water temperature caused higher COP. Therefore, the multi-generator system with by-pass solution might be an excellent chiller alternative to triple-effect absorption chiller with higher efficiency.

The Optimum Design of Impact Absorbing System for Spreader in System Variations (스프레더용 충격흡수기의 시스템 변화에 따른 최적설계)

  • Hong, Do-Kwan;Kim, Dong-Young;Han, Dong-Seop;Ahn, Chan-Woo;Han, Geun-Jo
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.311-316
    • /
    • 2002
  • On this study, to develop the impact absorbing system for spreader, we operated the dynamic response for models of three types consisting of spring and oil damper by the finite element analysis. Also, in the three types of impact absorbing system, we set the restricted stroke of piston to the static variables and the optimum design was operated to have the minimum value of the reaction force for the impact. As the result, the direct model of two degree of freedom system has lowest value, the model of one degree of freedom system has higher value than that and the parallel model of two degree of freedom system has the highest value. And we studied the effect that the change of spring constant and damping coefficient affect to the reaction force and as the result of the optimum design, we found that reaction force has the lowest value in the each of models.

Design and Implementation of MNAB for A-­MiDAS (A­-MiDAS 시스템의 MNAB 설계 및 구현)

  • Kim, Kyu-Hyung;Ryu, Jae-Hong;Ryu, Won
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.10c
    • /
    • pp.325-327
    • /
    • 2003
  • 망 자원의 효율적인 사용, 관리 및 기존의 망을 흡수 통합하기 위해서 차세대통합네트워크(NGcN), ALL­IP 망으로 망 진화가 이루어지고 있으며, 이에 따라 동기식 CDMA2000 과 비동기식 WCDMA의 이동 통신망도 통합 및 연동에 대한 연구가 진행되고 있다. 그리고, 망 개방화에 대한 분위기도 고조되는 상황에서 CDMA2000, WCDMA등과 같은 서로 다른 무선 액세스 망에서 동일한 게이트웨이를 통하여 무선인터넷 서비스를 제공하려는 움직임도 있다. 본 논문에서는 망 진화에 따른 망통합 및 연동과 망 개방에 따른 COMA200 과 WCDMA 의 서로 다른 무선인터넷 액세스를 동시에 지원하기 위한 시스템인 A­MiDAS(Advanced Mobile internet Data Access System)에 대해서 소개하고, A­MiDAS 내의 CDMA2000 과 WCDMA 를 수용하기 위해서 설계 및 개발된 MNAB(Mobile Network Access Board)에 대해서 기술한다.

  • PDF

Simulation of Compression/Absorption Hybrid Heat Pump System using Industrial Wastewater Heat Source (산업폐수열원 이용 증기압축식/흡수식 하이브리드 히트펌프 시스템의 시뮬레이션)

  • Baik Young-Jin;Park Seong-Ryong;Chang Ki-Chang;Ra Ho-Sang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1117-1125
    • /
    • 2004
  • In this study, in order to utilize the waste heat of industrial wastewater in the range of the relatively low temperature of 40~5$0^{\circ}C$ as a heat source, a hybrid heat pump system was considered by computer simulation method. In the simulation, an absorber, desorber and solution heat exchanger were modelled by UA values while a compressor and pump performance were specified by an isentropic efficiency. Simulation results show that the performance of hybrid heat pump can be up to 80% higher than that of conventional R134a heat pump when it makes a process hot water of 9$0^{\circ}C$ while the wastewater is cooled down to 2$0^{\circ}C$. As the absorber pressure increases, the system performance and deserter pressure increase with a favorable effect of a compressor discharge gas temperature drop.

Analysis on the Domestic and Abroad Policies and Regulations for the Gas Cooling Systems (국내외 가스냉방 지원제도 비교분석)

  • Kim, Yong-Chan;Cho, Kum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.201-207
    • /
    • 2009
  • In this study, the domestic and abroad policies and regulations on the gas cooling systems have been analyzed. First, the current policies were investigated in Korea and other countries to stimulate the distribution of the gas cooling systems. The advantage and disadvantage for each policy were evaluated. Finally, several policies were proposed for the effective distribution of the gas cooling systems.

  • PDF

고진공하 열유속흡수법을 이용한 위성체 열진공시험

  • Lee, Sang-Hun;Jin, Seong-Ho;Jo, Hyeok-Jin;Seo, Hui-Jun;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.116-116
    • /
    • 2012
  • 위성의 발사, 천이궤도, 운영궤도 등에서 위성체에 주어지는 극한 온도와 진공상태에서 위성체와 열제어시스템이 요구 조건을 만족시키는가를 확인하기 위하여 열진공시험을 수행한다. 우주에서 일어나는 환경변화는 극도로 심해서 지상에서 이와 유사한 열적 환경을 모사하는 방법은 쉽지가 않고, 일반적으로 위성체에 대한 열진공/평형 시험을 위해서는 열유속 흡수법과 열유속 투사법의 두 가지 방법을 사용한다. 한국항공우주연구원에서는 종래 접촉식 히터를 위성체에 직접 부착하는 방법에서 탈피하여 새로이 IR Lamp를 이용한 열유속 흡수법을 이용하여 위성체에 계산된 열유속을 인가하는 방법으로 위성체 열진공/평형시험을 수행하였으며, IR Lamp는 요구되는 100W~400W 사이의 열량을 오차 범위 5% 이내로 인가하여 균일한 온도 분포를 유지하고 성공적인 시험을 수행하였다.

  • PDF