• 제목/요약/키워드: 흡수식 시스템

검색결과 177건 처리시간 0.026초

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

GABA를 담지한 자성 키토산 나노입자 제조와 약물의흡수 및 방출 연구 (The Preparation of Magnetic Chitosan Nanoparticles with GABA and Drug Adsorption-Release)

  • 윤희수;강익중
    • Korean Chemical Engineering Research
    • /
    • 제58권4호
    • /
    • pp.541-549
    • /
    • 2020
  • 약물 전달 시스템(Drug Delivery System, DDS)은 인체에 발생한 질환을 치료를 할 때 약물을 효과적으로 투약하므로써 약물성분에 의한 부작용을 최소화하고, 약물의 효능을 최대한으로 크게하기 위해 기존의 알려진 성분의 약물이나 새로운 성분의 제형을 설계하여 환자의 약물치료 과정을 최적화하는 목적을 지향하는 기술로 정의된다. 본 연구에서는 Tripolyphosphate (TPP)의 농도가 키토산과의 가교결합을 통하여 제조되는 Chitosan nanoparticles (CNPs)의 크기에 미치는 영향을 측정하여 TPP의 농도가 낮을수록 작은 크기의 입자가 형성되는 것을 확인하였다. 그리고 산화철(Fe3O4)의 양에 따른 CNPs-Fe3O4의 특성을 측정하여 Fe3O4의 양이 많을수록 자성 약물 전달체로써의 특성이 잘 나타남을 확인하였다. 닌히드린 반응(Ninhydrin test)를 통하여 저농도 구간(0.004~0.02 wt%)에서는 Y = 0.00373 exp(179.729X) - 0.0114 (R2 = 0.989), 고농도구간(0.02~0.1wt%)에서는 Y = 21.680X - 0.290 (R2 = 0.999)의 γ-aminobutyric acid (GABA)의 농도에 따른 검량선을 얻었다. 이 검량선을 사용하여 흡수를 위하여 넣어주는 GABA의 양에 따른 최대 흡수율의 관계식 Y = -136.527 exp [(-90.0862)X] + 64.724 (R2 = 0.997) 을 얻었으며, 초기에 넣어주는 GABA의 양이 약 0.04 g인 지점부터는 약 62.5%로 흡수율이 일정해 지고, 시간에 따른 GABA-Fe3O4-CNPs로부터 방출되는 GABA의 양을 측정하여 약 24 hr 이후부터 약물 방출이 종료되는 것을 확인하였다. 또한 최적의 조건에서 만들어진 GABA-Fe3O4-CNPs는 약 150 nm의 구형 입자이며, 그에 따른 입자의 특성이 잘 나타나는 것을 확인하여 약물 전달체로써 적합함을 알 수 있었다.

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006)

  • 한화택;신동신;최창호;이대영;김서영;권용일
    • 설비공학논문집
    • /
    • 제20권6호
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

한국 고유종 미유기(Silurus microdorsalis Mori, 1936)의 난 발생 및 자치어 형태발달 (Embryonic and Larval Development of Slender Catfish, Silurus microdorsalis Mori, 1936, Endemic to Korea)

  • 김강래;곽영호;성무성;양현;조성장;윤봉한;방인철
    • 한국어류학회지
    • /
    • 제35권2호
    • /
    • pp.91-100
    • /
    • 2023
  • 본 연구는 자호천에 서식하는 미유기 Silurus microdorsalis의 난 발생 및 자치어의 형태발달을 관찰하여 초기생활사를 연구하였다. 2018년 6월에 친어를 포획하였으며, 수온 18℃, 광주기 14L: 10D에 조건에서 순환여과식으로 사육하였다. 인공 산란 유도를 위해 성숙한 친어 암컷에 Ovaprim (Syndel, Canada) 어체중 1 kg당 0.5 mL, 수컷에 HCG 어체중 1 kg당 10,000 IU를 주사하였고, 15시간 후에 건식법으로 인공 수정하였다. 성숙란은 연한 담황색의 분리 침성란이었다. 수정란의 난경은 2.16±0.06 mm (n=8)였고, 수정 후 181시간 만에 완전히 부화하였다. 수온별 난 발생은 수온 18℃에서 부화율 63.1±2.2%, 기형률 10.0±3.7%로 나타나 18℃가 부화에 적합한 수온이었다. 수온별 발생속도는 18℃에서 181시간, 21℃에서 109시간, 24℃에서 76시간으로 나타났으며, 초기 난 발생이 진행되지 않는 생물학적 영도는 평균 12.2℃로 추정되었다. 부화 직후 자어의 크기는 4.64±0.22 mm (n=8)였고, 부화 후 1일에 빛의 자극에 회피 반응(negative phototaxis)을 보였다. 부화 7일째는 전장 12.47±0.53 mm로 뒷지느러미 기조는 25~30개, 꼬리지느러미 기조는 14~16개가 관찰되었으며 난황이 모두 흡수되어 전기 자어기로 이행하였다. 부화 9일째는 전장 14.13±0.51 mm로 머리와 몸에 흑색 소포체가 90%가량 침착되었고 등지느러미가 생성되어 기조가 1개 관찰되었으며, 척색 말단이 위로 휘어지기 시작하여 중기 자어기로 이행하였다. 부화 15일째는 전장 16.69±0.31 mm로 꼬리지느러미 기조(18개)가 정수로 나타났으며 등지느러미 기조는 2개, 뒷지느러미 기조는 60~63개가 관찰되었으며, 척색 말단은 45℃로 완전히 휘어져 후기 자어기로 이행하였다. 부화 50일째는 전장 28.96±1.10 mm로 꼬리지느러미(18개), 등지느러미(3개), 가슴지느러미(11개), 뒷지느러미 기조(67~73개)가 정수로 나타나 치어기로 이행하였다.

역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구 (A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower)

  • 강성진;임동하
    • 청정기술
    • /
    • 제26권2호
    • /
    • pp.102-108
    • /
    • 2020
  • 오늘날 석유화학, 정밀화학, 대기오염 방지산업 등에서 증류, 흡수, 추출, 탈거 등 물질분리 단위공정으로 주로 충전탑을 사용해 왔다. 충전탑은 가스-액체, 가스-가스 시스템에서의 물질들과의 접촉에 의해 운전되어 진다. 이러한 충전탑은 낮은 압력손실, 경제적 효율, 고온성 액체물질 적용, 유지보수 용이, 유해가스 처리 등의 운영에서 장점들을 가진다. 충전탑의 성능은 충진물을 통해 가스와 액체를 고르게 분산함으로써 우수한 성능을 보이며, 이는 충전탑 설계에 있어 중요한 인자로 고려되어진다. 본 실험에서는 충진물에 대한 액체부하 및 가스용량인자에 따른 건조압력손실, 수력학적 압력손실, 액체함량 변화에 대한 기하학적 특성에 대하여 연구하였다. 결과로부터 설계인자와 운전조건 등의 유해가스 처리에 필요한 인자를 도출하였다. 임의 충진물인 raschig super-ring에 대한 건조압력손실을 측정한 결과, 가스용량인자가 증가할수록 일정하게 선형적으로 증가하였고, 가스용량인자가 0.630 ~ 3.448 kg-1/2 m-1/2 S-1에서 건조압력손실은 1.892 ~ 47.312 mmH2O m-1로 기존 산업현장에서 보편적으로 사용되는 35 mm pall-ring보다도 낮은 압력손실을 보였다. 그리고 raschig super-ring에 대한 수력학적 압력손실을 측정한 결과, 고유 액체부하에 대하여 가스용량인자가 증가할수록 압력손실도 함께 증가함을 확인하였고, 액체부하 변화에 따른 가스용량인자가 1.855 ~ 2.323 kg-1/2 m-1/2 S-1으로 20% 증가할 때, 압력손실은 약 17% 증가하는 것으로 나타났다. 마지막으로, 충진물 체적에 관한 액체함량은 가스용량인자에 의존된 액체부하 매개변수로서 액체부하 변화에 따른 가스용량인자 약 3.84 kg-1/2 m-1/2 S-1까지는 거의 일정한 액체함량을 보였으나, 그 이상에서는 급격하게 증가하였다.

공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 -)

  • 정광섭;김민수;김용찬;박경근;박병윤;조금남
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.