• Title/Summary/Keyword: 흡수관 형상

Search Result 17, Processing Time 0.034 seconds

Performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 흡수관 형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • New & Renewable Energy
    • /
    • v.2 no.1 s.5
    • /
    • pp.56-65
    • /
    • 2006
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam irradiation) on thermal performance of the collector are studied. However, the solar irradiation consists of the beam irradiation as well as the diffuse irradiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector, These effects are considered in this study experimentally and numerically. The accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Crashworthiness Analysis and Shape Design Optimization of Thin-walled Corrugated Tubes under Axial Impact (축 방향 충격을 받는 박판 파형관의 충돌안전도 해석 및 형상 최적설계)

  • Ahn, Seung Ho;Jung, Hyun Seung;Kim, Jin Sung;Son, Seung Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.128-135
    • /
    • 2021
  • Thin-walled tubes have been widely used as energy absorbing devices because they are light and have high energy-absorption efficiency. However, the downside is that conventional thin-walled tubes usually exhibit an excessive initial peak crushing force (IPCF) and a large fluctuation in the load-displacement curve, and thus lack stability as energy absorbing devices. Corrugated tubes were introduced to reduce IPCF and to increase the stability of collision energy-absorbing devices. Since the performance of corrugated tubes is highly influence by geometry, design optimization methods can be utilized to optimize the performance of corrugated tubes. In this paper, we utilize shape design optimization based on an adaptive surrogate model for crashworthiness analysis. The amplitude and wavelength of the corrugation, as well as curvature changes in the features, are the design variables. A morphing methodology is adopted to perform shape design parameterization. Through numerical examples, we compare optimal design results based on the adaptive surrogate model, with optimal results based on conventional surrogate models, and we show that direct optimal design methods produce more efficient results.

Far Field Test on Electromagnetic Wave Absorber for X-Band Radar (X-Band Radar용 전파흡수체의 실장실험)

  • 김동일;안영섭;정세모
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1993.10b
    • /
    • pp.31-43
    • /
    • 1993
  • 전파흡수체의 전파흡수능 측정방법은 기본적으로 다양한 마이크로파 측정법이 이용될수 있지만 레이다용 전파흡수체의 경우 전파의 주파수가 높기 때문에 파장이 짧아서 측정오차가 큰 문제점이 있다. 따라서 한국해양대학교 마이크로파연구실에서는 전파흡수체의 전파흡수능을 실험적으로 간단히 측정할 수 있게 하기 위한 20mm$\Phi$동축관 샘플홀더 및 Type-N connector로부터 20mm$\Phi$동축관으로의 변환 Adaptor를 제작하여 전파흡수체의 설계 및 특성(전파흡수능) 평가에 사용할 수있게 한 바 있으며 또 구형도파관을 이용한 재료정수 측정법을 채용하여 시료의 형상등의 영향을 적게 받는 실측 방법에 관하여 검토하여왔다 본 논문에서는 그동안 실험실적으로 설계하여 온 X-Band Radar용 전파흡수체를 실용의 상태에 가까운 반사전력법에 의하여 그 성능을 예비평가하고 실제의 target를 제작하여 X-Band Radar로 실장실험한 결과에 대하여 보고하고자 한다.

  • PDF

Thermal Performance Variations of Glass Evacuated Tube Solar Collectors Depending on the Absorber Shape and the Incidence Angle of Solar Ray (흡수관 형상과 일사 각도에 따른 진공관형 태양열 집열기의 성능 변화)

  • Kim Yong;Seo Tae-Beom;Kang Yong-Heack
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.659-668
    • /
    • 2005
  • The thermal performances of glass evacuated tube solar collectors are numerically investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are numerically investigated. Dealing with only collecting tube, the effects of not only the shape of the absorber tube but also the incidence angle of solar irradiation on the thermal performance of the collector are studied because the energy obtained by the absorber can be varied according to the incidence angle of solar radiation. However, the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, in actual system, the interference of solar irradiation and heat transfer interaction between the tubes should be considered. Therefore, this study considered these effects is carried out experimentally and numerically. The accuracy of the numerical model is verified by experiments. The result shows that the thermal performance of the absorber used a plate fin and U-tube is about $25\%$ better than those of the other models.

밀폐 및 분리 성능을 고려한 발사관 덮개의 개발

  • Kim, Hyung-Geun;Do, Young-Dae;Yoon, Young-Ju;Jung, Bal;Ryu, Ji-Youn
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.147-153
    • /
    • 1996
  • 발사관의 밀폐 및 분리성능을 위해 앞, 뒤 덮개의 재질을 내열성이 높고, 수분흡수성이 낮은 Noryl Plastic 재질로 선정하여 기계적 물성을 확인하였으며 덮개의 형상설계를 하였다. 유한요소 구조해석을 수행하여 분포하중 및 집중하중에 의한 응력상태를 고찰하고 분리성능을 검증하기 위해 공압 및 유도탄 충돌시험을 수행하였다. 이상의 과정를 통하여 개발된 덮개는 여러 가지 체계요구조건을 만족시켜 주는 것을 알 수 있다.

  • PDF

Thermal performance comparisons of the glass evacuated tube solar collectors of different absorber tubes (진공관형 태양열 집열기의 내부형상 변화에 따른 성능 비교)

  • Kim, Yong;Seo, Tae-Beom;Yun, Seong-Eun;Kim, Young-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.595-598
    • /
    • 2005
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam radiation) on thermal performance of the collector are studied. However the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector. These effects are considered in this study experimentally and numerically the accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF

Pool Boiling Performance of Enhanced Tubes for the Generator of an Absorption Chiller (흡수식 냉동기 재생기용 고성능 전열관의 풀비등 성능)

  • Sim, Yong-Sub;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1684-1691
    • /
    • 2015
  • For performance improvement and compactness, usage of enhanced tube is inevitable. However, studies on enhanced tubes for generator is very limited. In this study, pool boiling tests were conducted for 7 heat transfer tubes. Test range covered pressure 7.38~101.3 kPa and heat flux $20{\sim}40kW/m^2$. Results show that boiling heat transfer coefficient increases as pressure or heat flux increases. Under atmospheric condition, high heat transfer coefficients were obtained for notched fin and low fin tubes(225% and 202% of the 19.0 mm smooth tube, which yielded the lowest heat transfer coefficient). As pressure decreased, high heat transfer coefficients were obtained for a low fin tube(290% and 288% of the 19.0 mm smooth tube at 12.34 and 7.38 kPa).

A Study on Measuring Technique of Electromagnetic Wave Absorbing Characteristics of Microwave Absorbers (전파흡수체의 전파흡수특성 측정기법에 관한 연구)

  • 김동일;안영섭;정세모
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.1
    • /
    • pp.10-19
    • /
    • 1993
  • As a method to measure the absorbing characteristics of microwave absorber, the various microwave measuring method can be used fundamentally. There is, however, a big problem in measuring errors, since the wavelength of microwave such as used for radar is very short. Therefore, this research aimed to design and fabricate a converting adaptor of 20mm .PHI. coaxial tube from a Type - N connector to $20mm\phi$ coaxial tube and to use it for evaluating absorption characteristics of microwave absorber. Furthermore, the measurements of absorbing characteristics and material constants have been performed and reviewed, which were carried out by using the coaxial tube and by using rectangular waveguide, res- pectively. As a result, the validity of the proposed measuring method has been confirmed.

  • PDF

Internal Components Arrangement of MR Damper Landing Gear for Cavitation Prevention (캐비테이션 방지를 위한 MR 댐퍼형 착륙장치의 내부 형상 배치에 대한 연구)

  • Joe, Bang-Hyun;Jang, Dae-Sung;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.33-41
    • /
    • 2020
  • The landing gear of an aircraft is a device that absorbs and dissipates shock energy transmitted from the ground to the fuselage. Among the landing gears, the semi-active MR damper landing gear is supposed to show high-shock absorption efficiency under various landing conditions and secure the stability when out of control. In the case of the MR damper landing gear using an annular channel rather than orifice, Amesim, a commercial multi-physics program, is considered as more useful than the conventional two-degree-of-freedom model because the damping force generated by the pressure drop through the flow annular path can cause cavitation in the low-pressure chamber of the MR damper with a specific internal structure. In this paper, the main dynamic characteristics of the MR damper landing gear with an annular type flow path structure has been analyzed under the condition of cavitation. Based on the analysis results using Amesim, a design guideline for the MR damper flow path that prevents cavitation has been proposed based on the modification of the arrangement of internal components of the damper. The guideline was verified through a drop simulation.