• Title/Summary/Keyword: 흑구온도

Search Result 22, Processing Time 0.03 seconds

Effectiveness of the Aluminum Thermal Screens Depending on the Allocation Type (알루미늄반사재의 배치형태에 따른 보온 효과)

  • Kim, Young-Bok;Park, Joong-Choon;Huh, Moo-Ryong;Lee, Si-Young;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.16 no.4
    • /
    • pp.284-290
    • /
    • 2007
  • Thermal insulation effectiveness of the aluminum insulator depending on the direction of its glossing face, number of layer and allocation position was investigated. Modules were assembled by the combination of the variables levels and experimented for the case of 100 W and 40 W heating in the modules. The temperatures in the modules with the aluminum insulator were higher than those of the modules with polyester curtains. For the modules with one layer aluminum insulator, the inside temperatures of the modules with the direction of the glossing face outward were higher than those of the modules of inward. For two layer of aluminum insulator, the directions of those glossing faces were recommended to be the same direction for higher thermal insulation effectiveness. For the modules without heating, the temperature difference between the modules were not significant. The black globe temperatures in the modules were changed with the similar tendencies with the dry bulb temperatures in the modules. Those of the black globes were higher than those of the dry bulb temperatures as a whole. It was more distinguished for the modules of inward direction.

A Study on the Optimum Thermal Environmental Conditions in floor Heating (바닥난방의 쾌적한 온열환경조건에 관한 연구)

  • BongAeKim
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.55-62
    • /
    • 1993
  • 지금까지 연구해 온 바닥난방이 인체에 미치는 생리적, 심리적 영향에 관한 실험결과를 종합하여(건강한 여자를 피험자로 한 경우) 바닥난방의 Optimum Thermal Environmental Conditions 를 검토할 때는 다음의 조건을 만족시켜야 한다. (1) 저온 화상의 위험성을 고려하여 접촉부위의 피부온도가 $40^{\circ}C$를 넘지 않을 것. (2) 생리적 영향으로써 평균 피부온도가 $33{\;}-{\;}34^{\circ}C$의 범위일 것. (3) 심리적 영향으로써 온냉감 평가가 열적중성(slightly cool - slightly warm)으로 평가하고, 쾌적감 평가가 쾌적한 것으로 평가할 것. (4) 바닥온도에 대한 만족감 평가가 높을 것. (5) 흑구온도는 직접바닥에 앉는 자세에서는 $17^{\circ}C$ 이상, 의자에 앉는 자세에서는 $19^{\circ}C$ 이상일 것. 이상의 조건을 만족시키는 범위가 바닥난방의 Optimum Thermal Environmental Zone (Fig.7) 이라고 생각된다.

  • PDF

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.

Analysis of Indoor Thermal Environment and Cooling Effects by Ventilation Condition, and Spray irrigation or Nonspray of Single Span Plastic Greenhouses (환기조건 및 관수에 따른 단동 플라스틱 하우스의 냉방효과와 열환경 분석)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.27-39
    • /
    • 2000
  • In this study, we quantitatively compare the cooling effects of single span plastic greenhouses by opening or shutting of toot and side vents, and operation of fan or sprinkler. With those variables, we simultaneously made experiments at 4 greenhouses under equivalent conditions. By the experiments, the shutting of roof and side vents caused the high temperature difference of indoor and outdoor which the crops cannot be cultivated. However, the opening of the windows effectively reduced the indoor temperature and showed uniform temperature distribution in the greenhouses. The sprinkler abruptly reduced the indoor temperature, and showed excellent cooling effects. Finally, this paper provides the fundamental data for environmental control in greenhouses.

  • PDF

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Analysis of Cooling Effect on the Plastic Film Cover of Greenhouse Module Depending on the Shade and Water Curtain (온실지붕 차광과 수막 수준에 따른 냉방효과 분석)

  • Kim, Young-Bok;Park, Joong-Chun;Lee, Seung-Kyu;Kim, Sung-Tae;La, Woo-Jung;Huh, Moo-Ryong;Jeong, Sung-Woo
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.306-316
    • /
    • 2006
  • In this study, the effect of the shade level, water flow rate applied to the shades and the temperature of water on the greenhouse cooling was investigated depending on the shade level of 0, 35, 55, 75%, and water flow rate and water temperature by the test on the small wooden frames to find out the low cost cooling method. With increasing of the dry bulb temperature of outside air, the dry bulb temperature in the wooden frames increased. For the frames with the shade and water, inside temperatures of the frames were lower of -0.2$\sim$-1.2$^{\circ}C$ than the temperature of the outside air and higher than the water temperature. For the frames without water, inside temperatures of the frames were higher of 1.7$\sim$4$^{\circ}C$ than the outside and not affected by the shade level very much. The water flow rate and the temperature of the water were not the important factors to decrease the inside temperatures in the frames. The black globe temperature became lower with increasing of shade level. The shade frames with water curtain showed the best cooling effect because of reducing thermal radiation and cooling the plastic film cover. The surface temperatures of the plastic film cover for the water supplied modules became lower with increasing of the shade level. The relative humidity was decreased with the dry bulb temperature in the frame increasing and not affected by the dry bulb temperature of the outside air for the frames with the shade and water.