• Title/Summary/Keyword: 흉부 방사선 검사

Search Result 426, Processing Time 0.026 seconds

Systematic Diagnosis and Long-term Care of Cardiopulmonary Disease (심폐기 질환의 체계적인 진단과 장기-치료 관찰)

  • 김재웅
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.171-178
    • /
    • 1998
  • K14 patient with chronic dyspnea, who is senile female, early had suffered from radical mastectomy, radiotherapy, autoplastic transplantation, and knee arthritis. Abnormalities of cardiopulmonary function such as obesita, hypertension, mild left ventricular hypertrophy, and chronic pulmonary disease were found from K14 patient's clinical datas, which based on medical history and diagnosis, as well as evaluation of blood pressure, obesity, clinical diagnosis, chest PA, electrocardiogram, ultrasonocardiograph, and spirometery test. Diagnostic results were exactly analyzed, also long-term cares of K14 patient were discussed with related to the clinical literatures.

  • PDF

Solitary Fibrous Tumor of the Diaphragmatic Pleura (횡격흉막에서 발생한 고립성 섬유성 종양)

  • Lee, Chul-Burm;Lim, Hyoun-Soo;Jee, Heng-Ok;Park, Choong-Ki;Park, Yong-Wook;Kim, Hyuck;Jung, Won-Sang;Kim, Young-Hak;Kang, Jung-Ho
    • Journal of Chest Surgery
    • /
    • v.35 no.7
    • /
    • pp.568-572
    • /
    • 2002
  • We present a case of a 47-year-old woman with benign solitary fibrous tumor of the pleura originated in the diaphragm which was discovered incidentally on a chest radiograph. Chest radiograph, sonograph, computed tomographic scan and magnetic resonance image studies proved a well circumscribed and lobulated fibrous tumor of the pleura. During the subsequent right thoracotomy, the tumor was found to be encapsulated and consisted of firm mass. It was connected to the diaphragm with $5{\times}4$cm area by pedicle. Most of the tumor was free of adhesion. It was excised completely together with attached diaphragm. The tumor measured $23.5{\times}13.5{\times}8.0$cm and the pathologic diagnosis was benign solitary fibrous tumor and the attached diaphragm was free of disease.

Early Response of Cardiopulmonary Exercise Test(CPET) in Patients with Locally Advanced Non-Small Cell Lung Cancer Treated with Radiation (방사선 치료 후 폐암환자의 운동부하 심.폐 기능의 초기변화)

  • Shin, Kyeong-Cheol;Lee, Deok-Hee;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.4
    • /
    • pp.466-473
    • /
    • 2000
  • Background : Patients with locally advanced non-small cell lung cancer are often treated with radiation alone or in combination with chemotherapy. Both modalities have a potentially damaging effect on pulmonary function. In order to examine changes in the cardiopulmonary exercise function of patients with locally advanced non-small cell lung cancer before and after conventional radiotherapy, we conducted a prospective study involving patients with such cancer, that had received radiation therapy. Method : Resting pulmonary function test, thoracic radiographic finding and cardiopulmonary exercise test(CPET) were assessed prior to and 4 weeks following radiation therapy in 11 male patients with locally advanced non-small cell lung cancer. Patient with endobronchial mass were excluded. Results : The forces vital capacity (FVC), forced expiratory volume in 1 second ($FEV_1$ and maximal voluntary ventilation (MVV) did not decreased between before and 4 weeks after radiation but the diffusing capacity (DLCO) had decreased by 11% 4 weeks after radiation, which was not statistically significant. No changes in maximal oxygen consumption ($VO_2$max), carbon dioxide production ($VCO_2$), exercise time and work load were attributed to radiation therapy. Follow up cardiopulmonary exercise testing revealed unchanged cardiovascular function, ventilatory function and gas exchange. No difference in cardiopulmonary exercise test performance was observed between pre- and post-radiation. Conclusion : Cardiopulmonary exercise function did not decrease within the short-term after the radiation of patients with locally advanced non-small cell lung cancer.

  • PDF

Evaluation and Comparison of Signal to Noise Ratio According to Change of Kernel size of Heart Shadow on Chest Image (흉부 영상에서 커넬 크기변화에 따르는 신호대잡음비 비교평가)

  • Lee, Eul-Kyu;Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.443-451
    • /
    • 2017
  • The purpose of this study was to comparison of measure signal to noise ratio (SNR) according to change of kernel size from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 100 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p<0.05). In SNR results, with the quality of distributions in the order of kernel size 9*9 image, kernel size 7*7 image and original chest image, kernel size 3*3 image (p<0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the kernel size chest image.

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

Radiation Effect on Airway Obstruction from Lung Cancer (폐암으로 유발된 무기폐에 대한 방사선 치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.6 no.2
    • /
    • pp.121-125
    • /
    • 1989
  • Total 21 patients with airway obstruction from lung cancer treated with radiotherapy at Department of Therapeuctic Radiology, Yeungnam University College of Medicine, between April 1986 and December 1988 are retrospectively analysed by means of roentgenologic findings. Obtained results are as follows. 1. 15 out of 21 patients(71%) showed complete or partial response. 2. Patients with small cell lung cancer showed 100% response in spite of low dose(30GY/10 fractions). 3. Patients with non-small cell lung cancer treated with 50GY or over showed better response than below 45GY or below. 4. There is no relationship between the response and site of airway obstruction. These data suggested that high dose irradiation is more effective in the management of airway obstruction from lung cancer and meticulous radiotherapy planning with appropriate protection of normal lung and critical organs should be investigated in order to maximize radiation effect and minimize side effect, complication or sequelae.

  • PDF

The Clinical Value of Mediastinoscopy in Preoperative Staging of Non-small Cell Lung Cancer (폐암 환자의 수술 전 병기 결정에서 종격동경의 임상적 의의)

  • Haam, Seok-Jin;Kim, Do-Hyung;Jeon, Se-Eun;Lee, Doo-Yun;Paik, Hyo-Chae
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.745-751
    • /
    • 2007
  • Background: Mediastinoscopy is generally performed to confirm mediastinal lymph node metastasis in lung cancer patients. It still remains controversial whether mediastinoscopy should be performed in all patients with resectable non-small cell lung cancer (NSCLC). We studied the clinical value of mediastinoscopy in preoperative staging in NSCLC. Material and Method: We retrospectively studied 90 NSCLC patients who underwent radiological evaluation and mediastinoscopy followed by surgical resection from March 2002 to December 2004. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of each evaluation method were assessed and compared. Result: Specificity, PPV, NPV, and accuracy of mediastinoscopy were superior to those of radiological evaluation, but there was no significant difference in sensitivity. The sensitivity of mediastinoscopy was 28.6% in 62 patients with radiological N0/1 disease and 72.7% in 28 patients with radiological N2/3 disease. Seven of eight patients in whom positive nodes were not detected by the mediastinoscopy had subcarinal lymph node metastasis. Conclusion: Considering its invasiveness, the difficulty to reach certain node stations, and its low sensitivity in radiological N0/1 disease, mediastinoscopy should be selectively performed in radiological N2/3 disease rather than in all radiological cancer stages.

A Comparative Study of Mycoplasma pneumoniae Pneumonia according to Age (소아 마이코플라즈마 폐렴에서 연령별 비교)

  • Nahm, Chan-Hee;Cho, En-Young;Lee, Kyung-Yil;Kang, Jin-Han;Lee, Byung-Churl
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.135-139
    • /
    • 2005
  • Purpose : We investigated the clinical manifestations, radiographic and laboratory findings of children with M. pneumoniae pneumonia(MP) according to their age. Methods : A total of 75 children with MP who admitted to The Catholic University, Daejeon St. Mary's Hospital from July 2003 to February 2004, were classified into the three age groups : the ${\leq}2$ years of age(16 children), the children between 3 and 5 years of age(35 children), and the ${\geq}6$ years and older(24 patients). The diagnosis of MP was depended on the titers of anti-mycoplasma antibody that were measured 2 times, at admission and at discharge. Results : The total duration of the fever and the length of hospitalization were not different among the age groups. Although the white blood cell(WBC) value and differential was significantly different between the groups(P<0.01), a similar number in the WBC and reduced lymphocyte proportion was observed in all age groups compared to age-matched references. The patterns of pneumonia were significantly different according to age, i.e. segmental or lobar patterns were observed in 5 cases(31.3%) in the ${\leq}2$ years old group, but 16 cases(66.6%) in the >6 years old group(P<0.01). Conclusion : Although there was no difference in clinical findings according to age in MP, the radiographic finding was more severe in older children.

  • PDF

Survey on Radiotherpv Protocols for the Rectal Cancers Among the Korean Radiation Oncologists in 2002 for the Development of the Patterns of Care Study of Radiation Therapy (방사선치료 Patterns of Care Study 개발을 위한 2002년 한국 방사선종양학과 전문의들의 직장암 방사선치료 원칙 조사연구)

  • Kim, Jong-Hoon;Kim, Dae-Yong;Kim, Young-Ho;Kim, Woo-Chul;Kim, Chul-Yong;Sung, Jin-Shil;Son, Seung-Chang;Shin, Hyun-Su;An, Young-Chan;Oh, Do-Hum;Oh, One-Yong;Yu, Mi-Ryung;Yu, Hung-Jun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.44-65
    • /
    • 2003
  • Purpose : To conduct nationwide surgery on the principles In radiotherapy for rectal center, and develop the framework of a database of Korean Patterns of Care Study. Materials and Methods : A consensus committee was established to develop a tool for measuring the Patterns in radiotherapy Protocols for rectal cancer. The Panel was composed of radiation oncologists from 18 hospitals in Seoul Wetropolltan area. The committee developed a survey format to analyze radiation oncologist's treatment principles for rectal cancer. The survey items developed for measuring the treatment principles were composed of 1) 8 eliglblllty criteria, 2) 20 Items for staging work-ups and prognostic factors, 3) 7 Items for principles of combined surgery and chemotherapy, 4) 9 patient set-ups, 5) 19 determining radiation fields, 6) S radiotherapy treatment pians, 7) 4 physicalilaboratory examination to monitor a patient's condition during treatment, and 8) 10 follow-up evaluations. These items were sent to radiation oncoioglsts In charge of gastrolntestlnal malignancies in all hospitals (48 hospitals) In Korea to which 30 replies were received (63$\%$). Results : Most of the surrey Items were replied to without no major between the repliers, but with the fellowing items only 50$\%$ of repliers were in agreement : 1) Indications of preoperative radiation, 2) use of endorectal ultrasound, CT scan, and bone scan for staging work-ups, 3) principles of combining chemotherapy with radiotherapy, 4) use of contrast material for small bowel delineation during simulation, 5) determination of field margins, and 6) use of CEA and colonoscopy for follow-up evaluations. Conclusions : The Items where considerable disaggrement was shown among the radiation oncologists seemed to make no serious difference In the treatment outcome, but a practical and reasonable consensus should be reached by the committee, with logical processes of agreement. These Items can be used for a basic database for the Patterns of Care Study, which will survey the practical radiotherapy Patterns for rectal cancer in Korea.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.