• Title/Summary/Keyword: 흉복부 대동맥류

Search Result 21, Processing Time 0.021 seconds

Management for the Newly-Onset Aneurysmal Dilation of the Distal Aorta after an Endovascular Stent Graft Procedure for the Patient with Acute Aortic Dissection Type IIIb (급성 하행대동맥 박리증에서 스텐트-그라프트 삽입 후 새로이 발생한 원위부 대동맥류에 대한 인조혈관 대치술 치험 1예)

  • 이길수;방정희;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.427-430
    • /
    • 2003
  • The surgical managements for the complicated aortic disease is still one of most challenging fields for the cardiac surgeons. The endovascular stent graft procedure has been tried recently to avoid serious complications caused by traditional graft replacement technique. However, indications for the procedures or management methods for the complications have not been clearly elucidated so far. We report a case of successful management for the newly-onset aneurysmal dilation of the distal aorta after an endovascular stent graft procedure in a patient with acute aortic dissection type IIIB.

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Thoracoabdominal Aortic Aneurysm Repair after Renal Transplantation (신장 이식후 발생한 해리성 흉복부 대동맥류의 외과적 치험)

  • 김대영;문광덕
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.449-453
    • /
    • 1996
  • A successful resection of dissecting thoracoabdominal aortic aneurysm is presented in a patient who had undergone kidney transplantation 20 months previously. Because the transplanted kidney is more sensitive to ischemia than the normal kidney, a femoro-femoral bypass with a pump oxygenator was used for perfusion of the transplanted kidney during crossclamping. During the clamping time of 1)8 minutes, kidney perfusion was maintai ed with a perfusion pressure of (19 to 31) 27mmHg and the flow was 0.53 to 0.81 L/min. 32mm sized Hemashield (22 Cm in length) was interposed. The postoperative course was uncomplicated. We believe that performing the femoro- femoral bypass with a pump oxygenator is an effective and simple method for renal and spinal protection in such operations.

  • PDF

Clinical Experience of Abdominal Aortic Aneurysm (복부 대동맥류 수술의 임상적 고찰)

  • Kwak, Young-Tae;Lim, Sang-Hyun;Lee, Sak;Yoo, Kyung-Jong;Chang, Byung-Chul;Kang, Meyun-Shick;Hong, Yoo-Sun
    • Journal of Chest Surgery
    • /
    • v.36 no.4
    • /
    • pp.261-266
    • /
    • 2003
  • Background: Surgery of abdominal aortic aneurysm revealed high operative mortality. We reviewed our 11-years' experiences of abdominal aortic aneurysm operation and wish to obtain information on the treatment. Material and Method: From Jan. 1990 to Dec. 2000, 48 patients were operated due to abdominal aortic aneurysm in Yonsei Cardiovascular Center Mean age was $62.8{\pm}12.7$ and there were 40 males and 8 females. Among 48 patients, nine patients had ruptured abdominal aortic aneurysm, and mean aneurysm diameter of non-ruptured cases was $8.8{\pm}2.4$cm. Result: There were 6 early deaths, and early mortality was 12.5%. Among 9 patients of preoperative aneurysm rupture, three patients died (33.3%), and among 39 patients of non-ruptured cases, 3 patients died (7.7%). Among preoperative variables, age (p<0.05), preoperative BUN level (p<0.05), and DM (p<0.05) were risk factors of early mortality. Among discharged 42 patients, 40 patients were followed up (f/u rate=95.2%) and mean follow up was $3.6{\pm}0.2$ years. During follow up periods, five patients died (late mortality=11.9%), and Kaplan-Meier survival analysis revealed $81.7{\pm}7.6$% survival rate at five and ten year. Linealized incidence of graft related event was 3.53% per patient-year. Conclusion: Surgical mortality of ruptured abdominal aortic aneurysm was higher than non-ruptured cases; therefore, early resection of the aneurysm can decrease the surgical mortality.

Surgical Treatment of Anastomotic Pseudoaneurysm after the Aortic Replacement (대동맥치환술 후 문합부 가성동맥류 치험 2예)

  • Choi Pil-Jo;Kim Si-Ho;Bang Jung-Hee;Woo Jong-Su;Shin Tea-Bum;Cho Kwang-Jo
    • Journal of Chest Surgery
    • /
    • v.39 no.10 s.267
    • /
    • pp.786-790
    • /
    • 2006
  • An anastomotic pseudoaneurysm after the aortic replacement surgery is a rare complication which could be lethal when it ruptures. So it should be corrected whenever it is found after the aortic surgery. The authors performed three surgical corrections in 2 cases. The first case is type 8 chronic aortic dissection with abdominal aortic aneurysm. After an abdominal aortic replacement, the patient developed an anastomotic pseudoaneurysm. We treated him with a thoracoabdominal aortic replacement. The second case is ruputred throacoabdominal aortic aneurysm. After a thoracoabdominal aortic replacement, the patient developed an anastomotic pseudoaneurysm in the proximal anastomosis. We treated her with aortic arch replacement. But She developed another pseudoaneurysm in the aortic root anastomotic site. So we performed secondary operation to reinforce the anastomosis. They all recovered from the operations without any complication and are being followed up.

Surgical Correction of Thoracic Aortic Aneurysm Associated with Coronary Artery Disease A Case Report -A Case Report- (관상동맥질환을 동반한 대동맥류 수술치험 1례)

  • 우종수;서정욱
    • Journal of Chest Surgery
    • /
    • v.30 no.7
    • /
    • pp.724-728
    • /
    • 1997
  • We experienced a case of thoracic aortic aneurysm combined with coronary artery disease. A 68-year-old man complained of anginal pain in the left anterior chest and nonspecific pain in the posterior chest. The aneurysm was extending from left subclavian artery to the diaphragm and sign of impending rupture was noted in the chest CT. Coronary angiograms r vealed significant obstruction of left circumflex coronary artery(>95%) and left anterior descending artery(>50%). Exposure was obtained through the left posterolateral thoracotomy incision in the 4th intercostal space and then partial femoro-femoral cardiopulmonary bypass was established. After aortic cross clamping, the aneurysmal sac was opened and repaired with interposition of 26 mm Hemashield graft. Under the beating heart with femoro-femoral cardiopulmonary bypass, aorto-left circumflex coronary bypass with autogenous saphenous vein used as conduit was performed. Postoperatively multiple cerebral infarction ensued due to intraoperative hypovolemic shock and hypoxic brain damage during cardiopulmonary bypass. Currently, the patient's mental status is drowsy and in an improving state.

  • PDF

Aorta-esophageal Fistula That Developed after Endovascular Stent-grafting of a Mycotic Aneurysm - A case report- (감염성 대동맥류에 혈관 내 스텐트 삽입 시행 후 발생한 대동맥-식도루 - 1예 보고 -)

  • Nam, Jin-Hae;Park, Kay-Hyun;Yoo, Jae-Suk;Lee, Jae-Hang;Lim, Cheong;Jheon, Sang-Hoon
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.781-784
    • /
    • 2010
  • A 74-year-old woman presented at our hospital with hemoptysis. Three months ago, she had endovascular stent-grafting done by a general surgeon for a saccular thoracic aneurysm that was found accidentally following an episode of fever and chills. Despite a lasting fever after the procedure, she was discharged without further treatment and follow-up. She was subsequently admitted to the hospital for evaluation and several exams were performed. Chest CT scans and an esophagoscopy identified an aorto-esophageal fistula at the level of the aorta that was covered by a previous stent-graft. After extensive administration of antibiotics, surgery was done - esophagectomy, cervical esophago-gastrostomy and replacement of the thoracic aorta. She was later discharged uneventfully.

A Case of Extensive Thoracoabdominal Aortic Aneurysm Treated by Excision and Replacement of Dacron Graft (외과적 치료를 가한 광범위 흉복부 대동맥류 1례)

  • 유회성;유원하
    • Journal of Chest Surgery
    • /
    • v.3 no.2
    • /
    • pp.139-142
    • /
    • 1970
  • A Case of thoraco-abdominal aortic aneurysm involving from the lower descending- thoracic aorta to bifurcation of abdominal aorta into both common iliac artery is presented in special view-point of its surgical technic and postoperative complication. Operative technic is the most popular method of Dr. De Bakey's shunt of Dacron which is bridging thoracic aorta to terminal abdominal aorta primarily as temporary shunt but after anastomosing the individual hranch of left Renal, Celiac, Sup. meseateric and right Renal artery to corresponding part of the Dacron tube, the Dacroa graft is fixed as permanent graft in stead of excised thoraco-abdominal aorta. The patient died of acute renal failure and increasing evidence of CNS damage due to respiratory acidosis on 6th postoperative day hut this report will he a good experience in respect of further progress of aortic surgery in Korea.

  • PDF

Left Atrium-Femoral Artery Bypass using the Bio-Medicus Centrifugal Pump in Repair of Thoracic and Thoracoabdominal Aortic Aneurysm -Report of 7 cases- (좌심방-대퇴동맥 우회술을 이용한 흉부 및 흉복부 대동맥류 수술에 관한 임상적 고찰 -7례 보고-)

  • Yim, Soo-Bin;Ahn, Hyuk;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.27 no.4
    • /
    • pp.318-324
    • /
    • 1994
  • Cross-clamping of the descending thoracic aorta results in proximal hypertension,increase in left ventricular afterload,and impairment of distal organ perfusion. Bypass of the descending thoracic aorta is frequently advocated as an adjunct for repair of traumatic tears and degenerative aneurysms. Many methods of bypass have been proposed to provide distal perfusion and reduce left ventricular afterload during cross-clamping of the thoracic aorta. At Seoul National University Hospital, 7 patients were treated for the thoracic or thoracoabdominal aortic aneurysm using left atrium-femoral artery bypass with Bio-medicus centrifugal pump between October,1989, and January,1993. There were atherosclerotic thoracic aneurysm in 3 cases, thoracoabdominal aortic aneurysm due to chronic aortic dissection in 3 cases,aortic rupture due to trauma in 1 case. Total of 7 patients were operated by graft replacement with reimplantation of important branches. None of these cases developed severe complications and hospital death. We believe that the Bio-Medicus centrifugal pump is a simple and safe means of perfusing the lower body, kidneys, and spinal cord without necessitating heparinization.

  • PDF

Composite valve graft Replacement of the Aortic Root (Composite valve graft를 이용한 대동맥근부 치환술)

  • 백만종;나찬영;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.2
    • /
    • pp.102-112
    • /
    • 2002
  • This study was undertaken to analyze the outcome of composite valve graftreplacement(CVGR) for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and June 2001, 56 patients had replacement of the ascending aorta and aortic root with a composite graft valve and were reviewed retrospectively. Aortic regurgitation was present in 50 patients(89%), Marfan's syndrome in 18 patients(32%), and bicuspid aortic valve in 7(12.5%). The indications for operation were annuloaortic ectasia(AAE) in 30 patients(53.6%), aortic dissection in 13(23.2%), aneurysms of the ascending aorta involving aortic root in 11(19.6%), and aortitis in 2(3.6%). Cardiogenic shock due to the aortic rupture was present in 2 patients. Nine patients(16%) had previous operations on the ascending aorta or open heart surgery. The operative techniques used for CVGR were the aortic button technique in 51 patients(91%), the modified Cabrol technique in 4, and the classic Bentall technique in 1. The concomitant procedures were aortic arch replacement in 24 patients(43%), coronary artery bypass graft in 8(14.3%), mitral valve repair in 2, redo mitral valve replacement in 1, and the others in 7 The mean time of circulatory arrest, total bypass, and aortic crossclamp were 21$\pm$14 minutes, 186$\pm$68 minutes, and 132$\pm$42 minutes, respectively. Result: Early mortality was 1.8%(1/56). The postoperative complications were left ventricular dysfunction in 16 patients(28.6%), reoperation for bleeding in 7(12.5%), pericardial effusion in 2, and the others in 7. Fifty-three patients out of 55 hospital survivors were followed up for a mean of 23.2 $\pm$ 18.7 months(1-75 months). There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage, and CVGR-related late mortality was 1.9%. The 1- and 6-year actuarial survival was 98.1$\pm$1.9% and 93.2$\pm$5.1%, respectively. Two patients required reoperation for complication of CYGR(3.8%) and two other patients required subsequent operations for dissection of the remaining thoracoabdominal aorta. The 1- and 6-year actuarial freedom from reoperation was 97.8$\pm$2.0% and 65.3$\pm$26.7%, respectively.