• Title/Summary/Keyword: 휴대형 GC

Search Result 3, Processing Time 0.02 seconds

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

Development and Characteristic Study of a Portable Gas Chromatography (소형 GC 모듈의 개발 및 특성)

  • Lee, Myeong-Gi;Oh, Jun-Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.157-162
    • /
    • 2011
  • In the present study, we developed a portable GC module for real-time, quantitative determinations of gas mixtures in air sample. Capillary or packed column was coiled together with a heater wire and thermocouple in a small case. Together with the small and light weight sensors and valves as well as the rechargeable carrier gas canister, which permits collection and separation of samples, this system can determine the components of complex mixtures of air contaminants at low concentrations with a duty cycle of 10 min. When measured the various samples with a FID and TCD, the system showed, for a capillary column, a good resolution (R=8.3), high sensitivity, reproducibility, and linear dynamic range greater than three orders of magnitude. These results indicate that the portable GC module is expected to be used for a wide range of applications, particularly for in situ environmental monitoring, chemical processes, and regulation of contaminant emission.

Biosensor System for the Detection of Agrichemicals and Its Applications (농약 검출을 위한 바이오센서 시스템 연구 및 그 응용)

  • Park, Tae-Jung;Yang, Min-Ho;Lee, Sang-Yup;Kim, Soo-Hyun
    • KSBB Journal
    • /
    • v.24 no.3
    • /
    • pp.227-238
    • /
    • 2009
  • In the recent years, some organic toxic chemicals were used for obtaining high-yield productivity in agriculture. The undegraded pesticides may remain in the agricultural foods through atmosphere, water, and soil and cause public health problems to environmental resources and human beings even at very low concentrations. Small amounts of pesticides can affect a central nervous system, resulting in immunogenic diseases, infertility problems, respiratory diseases and born marrow diseases, which can lead even to death. Monitoring of the environmental pesticide is one of the important issues for the human well-being. Several kinds of biosensors have been successfully applied to the detection of agrichemical toxicity. Also, few platforms for biocide detection have been definitely developed for the degradation and reaction of pesticides. Biochip and electrochemistry experiments involve immobilizing a receptor molecule on a solid substrate surface, and monitoring its interaction with an analyze in a sample solution. Furthermore, nanotechnology can be applied to make high-throughput analyses that are smaller, faster and sensitive than conventional assays. Some nanomaterials or nanofabricated surfaces can be coupled to biomolecules and used in antibody-based assays and enzymatic methods for pesticide residues. The operation procedure has become more convenient as it does not require labeling procedure. In this paper, we review the recent advances in agrichemical defection research and also describe the label-free biosensor for pesticides using various useful detection methods.