• Title/Summary/Keyword: 휨하중

Search Result 1,012, Processing Time 0.035 seconds

Flexure-Shear Interaction Behavior of RC Columns under Cyclic Loading (주기하중을 받는 철근콘크리트 기둥의 휨-전단간의 상호거동)

  • Lee, Do-Hyung
    • The Journal of Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.151-158
    • /
    • 2002
  • 본 연구에서는 주기적인 하중하에서의 철근콘크리트 기둥의 이력응답거동을 예측할 수 있는 해석적인 모델의 개발을 다루고 있다. 철근콘크리트 기둥의 비탄성 휨, 전단 및 휨-전단 변형은 개발된 모델을 통항 주기적인 변위하에서 검토되었다. 개발된 모델들을 포함한 해석치와 실험치와의 비교분석를 통하여 본 연구에서 개발된 모델들의 검증을 실시하였고, 이 비교분석을 통하여 휨-전단간의 상호작용의 중요성을 강조하였으며, 본 연구에서 개발된 모델들의 정확성, 효율성 및 타당성을 입증하였다.

  • PDF

Design Bending Moment of Cantilever Slab for Long Span decks with KL-510 Load (KL-510 하중을 적용한 장지간 바닥판의 캔틸레버부 설계휨모멘트)

  • Chung, Chulhun;Joo, Sanghoon;Lee, Hanjoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.595-604
    • /
    • 2016
  • This paper proposed the design bending moments of cantilever slabs with KL-510 load according to span length of long span decks. Their span length range is from 6.0 to 12.0 meter, and length of cantilever slabs is from 30 to 50 percent of their span length. The effects of orthotropic concrete decks, stiffness of steel girders and multiple lane loading factors (MLLF) were reflected in the design bending moments. The proposed design bending moments of cantilever slabs were compared to the design bending moments with DB-24 load.

A Study on the Spacing and Required Flexural Rigidity of Cross Beams in Composite Two-Steel Girder Bridges (강합성 2-거더교의 가로보 배치 간격 및 소요 휨강성에 관한 연구)

  • Park, Yong Myung;Cho, Hyun Joon;Hwang, Min Oh
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.1-10
    • /
    • 2004
  • A study on the evaluation of proper spacing and required flexural rigidity of cross beams in composite two I-section steel girder bridges without a lateral and sway bracing system was performed. Specifically, a 2-lane, 40-m simple span bridge and a 3-span continuous (40+50+10m) bridge were designed, and structural analyses under dead load before and after composite, live, wind, and seismic loads were performed using spacing and flexural rigidity or cross beams as parameters. Through parametric analysis, the effect on the stresses due to the combination of loads and live load distribution was investigated. In addition. material and geometric nonlinear analyses under dead load before composite were performed to evaluate the lateral buckling strength of the steel girders and cross beam. Based on the results or such analyses, the proper spacing and flexural rigidity of cross beams at intermediate points and supports were proposed.

Estimation of Live Load Moment for Concrete Unfilled Steel Grid Deck Using Main Bearing Bar Distribution Factor (하중분배 계수를 적용한 비충전 강합성 바닥판 활하중 모멘트 산정)

  • Park, Young hoon;Kim, Sung Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.6
    • /
    • pp.1667-1676
    • /
    • 2014
  • Because of the different flexural rigidity between longitudinal and transverse direction, orthotropic plate theory may be suitable for describing the behavior of composite deck. The ratio of flexural rigidity between longitudinal and transverse direction affects the live load moment. Because of the ratio of flexural rigidity of concrete unfilled steel grid deck has a direct relationship with main bearing bar spacing, it is concluded that the study for the distribution factor which is effected by main bearing bar spacing and aspect ratio is needed. In this study, evaluate the live load moment of concrete unfilled steel grid deck using the AASHTO LRFD Bridge Design Specification and presents the distribution coefficient equation for concrete unfilled steel grid deck.

Effets of Steel Fiber Contents on Flexural Creep Behavior of High-Strength Concrete (강섬유 혼입률에 따른 고강도 콘크리트의 휨 크리프 특성)

  • Lim, Seong-Hoon;Kim, Dong-Hwi;Yun, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2020
  • In this paper, the flexural creep behavior of hooked-end steel fiber reinforced high-strength concrete was evaluated to investigate the steel fiber content influence on long-term behavior of flexural members. An experimental program consisted of nine prismatic beam specimens with dimensions of 150 × 150 × 600mm reinforced with different contents of steel fiber (0, 0.75 and 1.5% at the volume fraction). To introduce flexural creep loading to notched prismatic beam specimens, a four-point bending test setup was used. The sustained load with 40% of the flexural strength was applied by means of a lever system and controlled by a load cell for 90 days. During sustained loading, crack mouth opening displacement (CMOD) was monitored. Conventional flexural test after creep tests were carried out to evaluate the residual capacity of each specimen. Test results showed that steel fiber content has a significant effect on the flexural creep behavior of high-strength concrete and long-term flexural load with 40% of flexural strength doesn't generate negative effects on the residual capacity of steel fiber reinforced high-strength concrete.

Flexural Behavior of Reinforced Concrete Beams Considering Steel Corrosion (철근의 부식을 고려한 RC보의 휨파괴 거동)

  • Eo, Seok-Hong;Lee, Chang-Hyun;Lee, Sang-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3251-3259
    • /
    • 2014
  • This paper presents experimental and analytical research results to predict nonlinear flexural behavior of corroded reinforced concrete beams. For this purpose, a series of test and an analytical simulation using the Maaddawy's model were carried. Test specimens of total 12 RC beams were placed in accelerated corrosion status using salt water spray test chamber for 5 months and 10 months, after they were preloaded up to 30% and 60% of the maximum load corresponding to nominal flexural strength. The test results showed that flexural strength and ductility decreased to 5.4% and 43% at the most respectively due to breakdown of bond at the steel-concrete interface. Comparative study between the analytical predictions and the experimental results showed that the Maaddawy's model can be applied to predict a real corroded RC flexural members.

Flexural Capacity of RC Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트로 보강된 철근콘크리트 보의 휨성능)

  • Park, Hyun-Jung;Cho, Baik-Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.3
    • /
    • pp.177-187
    • /
    • 2004
  • This investigation attempts to analyze the flexural behavior of a strengthened beam with carbon fiber sheets in three stages according to the conditions of the constituents : elastic stage, pre-yielding stage, and post-yielding stage. The proposed analytical method for strengthened beams is compared with the experimental results such as yield load, ultimate load, and flexural rigidities. The contributions of the constituents to the strengthened beam capacity are examined from the flexural analysis. The validity of using KCI strength method to estimate ultimate moment of a strengthened beam is also investigated.

Flexural Behaviors of Reinforced Concrete Beams Strengthened with Carbon Fiber Sheets (탄소섬유시트로 보강된 철근콘크리트 보의 휨 거동)

  • Kim, Seong-Do
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.227-234
    • /
    • 2010
  • To investigate the flexural behavior of RC beams strengthened with carbon fiber sheets, 1 control beam and 8 strengthened beams(4 NU-beams without U-shaped band and 4 U-beams with U-shaped band) are tested. The variables of experiment are composed of the number of carbon fiber sheets and the existence of U-shaped band, etc. The experimental results showed that the strengthening system with U-shaped band controls the premature debonding and provides a more ductile failure mode than the strengthening system without U-shaped band. It can be found from the load-deflection curves that as the number of fiber sheets is increased, the maximum strength and the flexural rigidity is increased. The experimental results are compared with the analytical results of nonlinear flexural behaviors for strengthened RC beam. The proposed analytical method for strengthened beams is proved to be accurate by an experimental investigation of load-deflection curve, yield load, maximum load, and flexural rigidities in the pre- and post-yielding stages.

Performance of GFRP, CFRP and AFRP Sheet Reinforced Concrete under Impact Loads (GFRP 및 CFRP, AFRP sheet로 보강한 콘크리트의 충격 저항 성능)

  • Min, Kyung-Hwan;Lee, Seul-Kee;Cho, Seong-Hun;Yoon, Young-Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.39.1-39.1
    • /
    • 2010
  • 본 연구에서는 정하중 및 충격하중 하에서 FRP(fiber reinforced polymer) sheet의 보강 성능을 평가하기 위해 섬유와 레진의 종류, sheet 종류, 보강 방법에 따른 휨 실험을 실시하였다. 이를 위해 GFRP와 CFRP, AFRP sheets로 보강된 $100{\times}100{\times}400mm$ 각주형 콘크리트 공시체의 하면 보강, 중앙 U형 스트립, 그라고 이 둘을 동시에 보강한 시험체를 제작하였고, 정하중 휨 실험과 낙하식 충격하중 실험을 실시하였다. 정하중 실험에서 중앙부 U형 스트립으로 보강한 시험체는 섬유의 방향과 균열의 진전 방향이 일치하여 보강효과가 거의 없었지만 CFRP와 AFRP로 하면 및 이중 보강한 시험체는 높은 휨성능을 보였다. 반면 충격하중 실험에서는 중앙부 U형 스트립 보강이 다소 성능을 향상 시켰고, 하면 및 이중 보강한 시험체는 큰 변형과 높은 에너지 소산 능력을 보였다.

  • PDF

Analysis of Bending Performance of Built-up Beam Headers (목재 조립보 헤더의 휨 성능 분석)

  • Jang, Sang Sik;Kim, Yun Hui;Park, Young Ran
    • Journal of the Korean Wood Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.118-125
    • /
    • 2007
  • To obtain design data for built-up beams used as headers in light-frame timber construction, three members of $2{\times}6$ ($38{\times}140 mm$), $2{\times}8$ ($38{\times}184 mm$), $2{\times}10$ ($38{\times}235 mm$) and $2{\times}12$ ($38{\times}286 mm$) were built up as specimens of bending tests. The bending strengths of built-up headers were obtained through bending tests of these specimens, and it was considered that span tables can be calculated for various loading conditions based on the bending strengths of built-up headers. The bending strengths of built-up headers were determined as the bending stresses at 10 mm deflection of specimens from the results of bending tests of built-up beam specimens. Span tables for built-up headers were considered to be obtained by assuming five loading conditions for headers used in exterior walls and two loading conditions for headers used in interior walls. Among these 7 loading conditions, 5 loading conditions applied to headers in exterior walls included dead loads, live loads and snow loads and 2 loading conditions applied to headers in interior walls included dead loads and live loads.