• Title/Summary/Keyword: 휨좌굴

Search Result 143, Processing Time 0.024 seconds

Evaluation of Flexural Strength of Hybrid Girder composed of HSB800 and HSB600 Steel (HSB800 및 HSB600 강재를 적용한 하이브리드거더의 휨강도 평가)

  • Park, Yong Myung;Kang, Ji Hoon;Lee, Kun Joon;Kim, Hee Soon
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.6
    • /
    • pp.581-594
    • /
    • 2014
  • In this paper, flexural resistance of hybrid girder under uniform bending moment was evaluated, which is composed of HSB800 and HSB600 steel for the flange and web, respectively. Doubly-symmetric and monosymmetric sections with noncompact or compact flange and slender, noncompact or compact web were considered. Nonlinear analyses with 3-dim. shell element model were performed to determine the 'flexural resistance of section' and the 'lateral torsional buckling strength' by taking initial imperfection and residual stress into account. The numerical results were compared with the AASHTO LRFD and Eurocode 3 specifications and also the applicability of AASHTO LRFD appendix A6 was examined for the sections with noncompact and compact web.

The Structural Behavior of Strong Axis Connections by Type of Weak Axis Connection - In Case of Loading Gravity Load - (약축 접합부 형식에 따른 강축 접합부의 구조적 거동 - 연직하중이 작용하는 경우 -)

  • Kim, Sang Seup;Lee, Do Hyung;Ham, Jeong Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.2 s.69
    • /
    • pp.275-284
    • /
    • 2004
  • The behavior of the connection for beam-to-column weak axis connection and its details should be identified. Thus, each element is considered a panel zone, and the horizontal stiffener's presence or absence and position in bracket-type welding connection are used as variables to compare the behavior of strong axis connection and weak axis connection. In this study, the strength of connection is calculated by substituting the simple beam-strengthened vertical stiffeners for connection in the presence of horizontal stiffeners. In the absence of horizontal stiffeners, the strength of connection can be calculated using local flange bending strength considering local web yielding strength, web crippling, and web buckling strength. The results of the theoretical analysis and experiments are compared.

Experimental Study on Structural Behavior of Tapered Member with Non-compact Flange and Web (판폭두께비가 큰 변단면 휨부재의 구조성능에 관한 실험적 연구)

  • Chung, Kyung-Soo;Jeon, Bae-Ho;Park, Man-Woo;Do, Byung-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.3
    • /
    • pp.357-365
    • /
    • 2011
  • The current trends in steel construction intend to use tapered sections to minimize as much as possible the use of excess material. This can be done by choosing the cross-sections to be as economical as possible, leaving the classical approach of using prismatic members. In addition, it is important to predict the buckling behavior of tapered member with large depth-to-thickness ratio in order to prevent the collapse of PEB system subjected to overloads. An experimental investigation of buckling behavior of tapered beam was presented. The primary test parameter was depth-to-thickness ratio and taper ratio. Using initial stiffness and load-carrying capacity proposed by current provision, the simple plastic hinge method using modified Yoda's model and finite element analysis, the prediction of a moment-rotation curve of linearly tapered member was presented. Moreover, comparisons between analytical and experimental data for moment-rotation curves were accomplished.

Evaluation of Load-Carrying Capacity Loss due to Corrosion in Thin-Walled Section Steel Members (판폭두께비가 큰 휨부재의 부식발생에 따른 구조성능평가에 관한 연구)

  • Chung, Kyung Soo;Park, Man Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.6
    • /
    • pp.619-626
    • /
    • 2009
  • The use of thin-walled flexural members has proven to be a practical way to achieve the lowest cost in the construction of prefabricated long-span, low-rise building frames in steel. On the other hand, most of these structures are subjected to corrosion due to environmental exposure, which can reduce their carrying capacity. Corrosion damage is a serious problem for these structures as it causes thickness loss. That is, the class of a section (plastic, compact, non-compact, or slender) may change from one to another due to the loss of thickness of the compression flange and web due to corrosion. In this study, the effects of corrosion on thin-walled members in long-span steel frames were evaluated with regard to the moment-rotation curve, initial stiffness, maximum load capacity, stiffness in the post-maximum capacity, and energy absorption.

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

Ultimate Shear Strength of Tapered Steel Plate Girders (높이가 변하는 플레이트거더의 극한전단강도)

  • Lee, Doo Sung;Park, Chan Sik;Lee, Sung Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2A
    • /
    • pp.391-399
    • /
    • 2006
  • Plate girders with variable depths have been often used at piers considering not only the economy but also an aesthetic aspect. Tapered plate girders exhibit more complicated behaviors than prismatic girders especially under shear. However, a comprehensive design method for the determination of the shear strength has yet to be developed mainly due to lack of study. In this study, investigated is the buckling and ultimate behaviors of tapered plate girders subjected to shear through finite element analyses. From the analysis results, a simple design formula is suggested for the evaluation of the shear strength of tapered plate girders.

Analysis and Design of Support Strut in Innovative Prestressed Scaffolding(IPS) System (혁신적 프리스트레스트 가시설 구조시스템(IPS)에 적용되는 중간 버팀보의 해석 및 설계)

  • Kim, Sung Bo;Han, Man Yop;Kim, Moon Young;Kim, Nak Kyung;Han, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.627-636
    • /
    • 2005
  • The analysis and design procedure of intermediate support strut for the innovative prestressed scaffolding (IPS) system was presented in this paper. The stability check of intermediate support strut is required as the behavior of the strut system is similar to that of the built-up column. The computer analysis model of the support strut was constructed for in-plane and out-of-plane buckling analysis, and the design of the support strut was performed. Using the eigenvalue for the buckling load and the member forces of support strut under design earth pressure, the effective buckling length was estimated. The allowable axial and bending stresses were calculated considering the effective buckling length. The combined stresses due to these axial forces and bending moment were estimated to be satisfied the safety condition of the intermediate support strut.

Experimental Study on Ultimate Shear Behaviour of Longitudinally Stiffened Plate Girder Web Panels (수평보강재가 있는 판형복부판의 극한전단거동에 관한 실험연구)

  • Lee, Myung Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.2 s.39
    • /
    • pp.167-179
    • /
    • 1999
  • The thin web panels of plate girders often need to be reinforced with transverse stiffeners to increase the shear strength. Since early 1960s, extensive researches have been conducted on the ultimate shear strength of plate girder webs with transverse stiffeners. These results have been first adopted into AASHTO(1970) and British Standard(1983) Specifications for the determination of the ultimate shear strength of transversely stiffened web panels. Although the main purposes of reinforcing web panels with longitudinal stiffeners are to increase the buckling strength and to control the lateral deflections due to bending, it has been reported that the longitudinal stiffeners increase the shear strength. However lack of studies has kept the effects of the longitudinal stiffeners on the ultimate shear strength from the design of plate girder web panels. In the present study an experimental investigation is carried out in order to assess the increment of the ultimate shear strength of shear web panels due to the longitudinal stiffeners and the results are compared with the existing failure theories.

  • PDF

Deformation Capacity of Inverted V-Type Brace Strengthened by Built-up Non-welded Buckling Restraint Element (조립형 무용접 좌굴방지재로 보강된 역V형 가새의 변형성능)

  • Kim, Sun Hee;Moon, Ji Young;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.261-271
    • /
    • 2015
  • Steel concentrically braced frame is an efficient system that can acquire resistance against the lateral force of buildings with the least amount of quantity. In this study is intended to proceed on the research of schemes for reinforcement by supplementing previously installed H-formed brace with non-welded cold-formed plastic stiffening materials restricting the flexure and buckling and acquire a consistent strength on the tensile and compressive force. As for the measures of supplementing previously-installed inverted V-formed braced frame, stiffening materials in the previous studies were converted to weak-axial supplementing materials to suggest a specific scheme evaluating the structural function through an experiment of members, interpretation of members, and frame-focused experiment. Reinforced brace satisfied the requirement to be prevent AISC brace from being ruptured due to imbalanced strength in the beam.

Improved Static Element Stiffness Matrix of Thin-Walled Beam-Column Elements (박벽보-기둥 요소의 개선된 정적 요소강성행렬)

  • Yun, Hee Taek;Kim, Nam Il;Kim, Moon Young;Gil, Heung Bae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • In order to perform the spatial buckling and static analysis of the nonsymmetric thin-walled beam-column element, improved exact static stiffness matrices were evaluated using equilibrium equation and force-deformation relationships. This numerical technique was obtained using a generalized linear eigenvalue problem, by introducing 14 displacement parameters and system of linear algebraic equations with complex matrices. Unlike the evaluation of dynamic stiffness matrices, some zero eigenvalues were included. Thus, displacement parameters related to these zero eigenvalues were assumed as polynomials, with their exact distributions determined using the identity condition. The exact displacement functions corresponding to three loadingcases for initial stress-resultants were then derived, by consistently combining zero and nonzero eigenvalues and corresponding eigenvectors. Finally, exact static stiffness matrices were determined by applying member force-displacement relationships to these displacement functions. The buckling loads and displacement of thin-walled beam were evaluated and compared with analytic solutions and results using ABAQUS' shell element or straight beam element.