• Title/Summary/Keyword: 효율화

Search Result 15,022, Processing Time 0.055 seconds

The Trend of Aviation Terrorism in the 4th Industrial Revolution Period and the Development Direction for Domestic Counter Terrorism of Aviation (제4차 산업혁명 시대의 항공 테러리즘 양상 및 국내 항공테러 대응체계 발전방향)

  • Hwang, Ho-Won;Kim, Seung-Woo
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.32 no.2
    • /
    • pp.155-188
    • /
    • 2017
  • On the one hand, the 4th Industrial Revolution provides a positive opportunity to build a new civilization paradigm for mankind. However, on the other hand, due to the 4th Industrial Revolution, artificial intelligence such as 'Goggle Alpha Go' revolutionized and even the human ability was replaced with a 'Silicon Chip' as the opportunity to communicate decreases, the existence of human beings is weakened. And there is a growing concern that the number of violent crimes, such as psychopath, which hunts humans as games, will increase. Moreover, recent international terrorism is being developed in a form similar to 'Psychopathic Violent-Crime' that indiscriminately attacks innocent people. So, the probability that terrorist organizations abuse the positive effects provided by the Fourth Industrial Revolution as means of terrorism is increasing. Therefore, the paradigm of aviation terrorism is expected to change in a way that attacks airport facilities and users rather than aircraft. Because airport facilities are crowded, and psychopathic terrorists are easily accessible. From this point of view, our counter terrorism system of aviation has many weak points in various aspects such as: (1) limitations of counter-terrorism center (2) inefficient on-site command and control system (3) separated organization for aviation security consultation (4) dispersed information collection function in government (5) vulnerable to cyber attack (6) lack of international cooperation network for aviation terrorism. Consequently, it is necessary to improve the domestic counter terrorism system of aviation so as to preemptively respond to the international terrorism. This study propose the following measures to improve the aviation security system by (1) create 'Aviation Special Judicial Police' (2) revise the anti-terrorism law and aviation security law (3) Strengthening the ability respond to terrorism in cyberspace (4) building an international cooperation network for aviation terrorism.

  • PDF

A Study on Floating Offshore LNG Bunkering System and its Economic Analysis (해상부유식 LNG 벙커링 시스템 R&D사업의 경제성 분석)

  • Seo, Sunyae;Cho, Sungwoo
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.4
    • /
    • pp.69-89
    • /
    • 2014
  • The business performance of port industry is steadily getting worse due to international environmental regulation. The port industry should be prepared according to ambient condition change. IMO(International Maritime Organization) is tightening up environmental regulation of vessel and maritime industry field. ECA(Emission Control Area), starting with the Baltic, has initialized and has been expanded. Korea must strengthen the control of vessel in accordance with IMO's restriction, if Korea is designated as emission control area. These situations cause the expansion of LNG-fuelled ships. Add to the larger trend of ships, Korean government should be done a preemptive action against LNG bunkering industry. This study proposes the concept of floating offshore LNG bunkering system and is conducted its economic feasibility evaluation based on empirical analysis. We examine the theoretical foundation and basic information via "A Planning Study on the Engineering Development of Floating Offshore LNG Bunkering Terminal" in 2013 and we evaluate the business potential by using the report above mentioned. The results of this study are as follows. The values of B/C analysis are between 0.679 and 2.516 depending on market share and R&D contributiveness. In case of 10.9%(market share), if market share are 50% and 60%, the value of B/C analysis are 0.697 and 0.837 respectively. Except in two cases, all remaining values are over 1.0. Moreover, the research is conducted sensitivity analysis to remove the project uncertainty. In order to maintain economical validity, a project manager have to establish business strategies which are not to cause increase of expense and sustain market share and R&D contributiveness in the scenario with normal levels.

Optimum Capacity of Retention Basin for Treating Nonpoint Pollutants and Its Removal Efficiency in Industrial Complex Areas (산업단지내 비점오염물질 처리를 위한 적정 저류조 용량 산정 및 처리효율)

  • Kim, Lee-Hyung;Lee, Byung-sik;Kwon, Soo-Youl
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.75-85
    • /
    • 2005
  • The Construction of industrial complex areas means the increase of imperviousness rate and the increase of nonpoint pollutant emissions during a rainfall. Generally the retention basin can become the alternative for removing and controling these nonpoint pollutants. Recently Ministry of Environment are trying to change the purpose of retention basins from flooding control to nonpoint pollutant control. In order to propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area, the best management practices should be established to control the nonpoint pollutant. Landuses of the research area are classified to the categories of the 1st manufacturing industry, metal industry, fiber and chemical product manufacturing industry, etc. Therefore, this research was performed to understand washed-off characteristics of stormwater and to suggest the controling method of nonpoint pollutants. The optimum capacity of the retention basin can be determined by analyzing the relationships among data of rainfall, runoff, washed-off pollutants from the areas. The rainfall analysis using the data of normal year, recent 2, 5 and 10 years shows that the 80% rainfall frequency was occurred on 10mm accumulated rainfall, but which is not considered the first flush effect. However, by considering the first flush effect, the appropriate treatment capacity of rainfall can be decreased to 4-5mm accumulated rainfall. Using the criteria, the optimum capacity of retention basin is determined to $12,000m^3$ in the research area. The washed-off nonpoint pollutant loading from the areas have beeb calculated to 435ton/yr for TSS, 238ton/yr for COD, 8,518kg/yr for TKN and 1,816kg/yr for TP. The mass of 78.3ton/yr for TSS, 20.4ton/yr for BOD, 128.6ton/yr for COD, 4.6ton/yr for TKN and 980kg/yr for TP can be reduced by constructing the retention basin. The sediment accumulation rate is also calculated by $6.53kg/m^2-hr$.

  • PDF

A study on ecological reprocessing and creation of biotope by reuse of treated waste water and nonpoint pollution source of stream (하수처리수와 하천 비점오염원을 이용한 생태적 재처리 효과와 생물 서식처 창출 방안 - 왕포천 생태적수질정화비오톱(Sustainable Structured wetland Biotop) 시스템 사례를 중심으로 -)

  • Byeon, ChanWoo;Lee, JongnChan
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.374-383
    • /
    • 2019
  • The Wangpo stream located in the Buyeo-gun was a small stream with both low water quality and quantity due to the cultivated land and settlement area through the stream. In order to restore ecosystem, the Sustainable Structured wetland Biotop system was applied to treat 1,500 to 7,000 ㎥/d amount of effluent water pumped from the Buyeo sewage treatment plant facility as well as inflowed from nonpoint pollution source of Wangpo stream. As a result of continuous monitoring for 2 years from 2016 to 2018 after completing restorative construction, the average BOD5 as an index of organic pollution was 7.3 mg/L and the average effluent concentration became 2.1 mg/L, showing an improvement by 71.2%. The average inflow concentration of T-N was 7.953 mg/L and the average outflow concentration was 3.379 mg/L, showing 57.5% of improvement. The average inflow concentration of T-P was 0.177 mg/L and the average outflow concentration was 0.052 mg/L, showing about 70.7% improvement. The results of ecological monitoring after creating biotope by reuse of treated waste water and nonpoint pollution source of the Wangpo Stream are as follows. The plant taxa founded in water SSB(Sustainable Structured wetland Biotop) system of the Wangpo Stream was total 41 species in 21 families, showing a higher proportion of naturally introduced plant than that of artificially planted species. In case of other terrestrial animals, both amphibian and reptile group were confirmed as 3 species in 6 families, avian group was 25 species of 15 families, and mammal group observed 5 species in 5 families, respectively. All species have been created and enhanced through purified water inhabited in the SSB(Sustainable Structured wetland Biotop) system as a treatment wetland, eventually migrating to the Wangpo Stream.

Quality Characteristics of Jochung Containing Various Level of Letinus edodes Powder (표고버섯 가루를 이용한 조청의 품질 특성)

  • Park, Jung-Suk;Na, Hwan-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.768-775
    • /
    • 2005
  • Lentinus edodes powder was added at 1-3%(w/w) to improve functional properties of jocheong. Content of crude protein, ash, crude lipids, total mineral, free sugar and reducing sugar increased with increasing amount of L. edodes powder, while viscosity and solid and carbohydrate contents decreased. Through amino acid analysis, 17 amino acids were identified and quantified, glutamic acid being the major amino acid. No significant differences were observed in fatty acid composition and pH between control and L. edodes powder-added jocheong. Addition of mushroom powder in jocheong decreased lightness, yellowness and redness in Hunter's color value. Sensor score of jucheong containing 1% of L. edodes powder was similar to that of control. Results showed jocheong containing less than 2% L. edodes powder gave highest scores in quality characteristics and sensory evaluation.

Mock-up Test of Temperature Crack Reduction Method Application by Setting Time Control of Mat Foundation Mass Concrete (응결시간조정에 의한 매트기초 매스 콘크리트의 온도균열저감 공법적용의 Mock-up Test)

  • Han, Cheon-Goo;Lee, Jae-Sam;Noh, Sang-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.9 no.4
    • /
    • pp.55-61
    • /
    • 2009
  • Recently, the number of high-rise buildings being built in Korea by major construction companies for residential and commercial use has been increasing. When constructing a high-rise building, it is necessary to apply massive amounts of concrete to form a mat foundation that can withstand the huge load of the upper structure. However, it is of increasing concern that due to limitations in terms of the amount of placing equipment, available job-sites and systems for mass concrete placement in the construction field, it is not always possible to place a great quantity of concrete simultaneously in a large-scale mat foundation, and for this reason consistency between placement lift cannot be secured. In addition, a mat foundation Is likely to crack due to the stress caused by differences inhydration heat generation time. To derive a solution for these problems, this study provides test results of a hydration heat crack reduction method by applying placement lift change and setting time control with a super retarding agent for mass concrete in a large-scale mat foundation. Mock-up specimens with different mixtures and placement liftswere prepared at the job-site of a newly-constructed high-rise building. The test results show that slump flow of concrete before and after adding the super retarding agent somewhat Increases as the target retarding time gets longer, while the air content shows no great difference. The setting time was observed to be retarded as the target retarding time gets longer. As the target retarding time gets longer, compressive strength appears to be decreased at an early stage, but as time goes by, compressive strength gets higher, and the compressive strength at 28 days becomes equal or higher to that of plain concrete without a super retarding agent. For the effect of placement lift change and super retarding agent on the reduction of hydration heat, the application of 2 and 4 placement lifts and a super retarding agent makes it possible to secure consistency and reduce temperature difference between placement lifts, while also extending the time to reach peak temperature. This implies that the possibility of thermal crack induced by hydration heat is reduced. The best results are shown in the case of applying 4 placement lifts.

Problems Analysis and Revitalization Plan of Urban Development Projects by the Land Readjustment Method (환지방식에 의한 도시개발사업의 문제분석 및 활성화대책)

  • Kim, Hyoung-Soo;Lee, Young-Dai;Lee, Jun-Yong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.5
    • /
    • pp.37-46
    • /
    • 2009
  • This research will focus on the public agencies, designers, supervisors, building cooperation, and contractor who involved in urban development plan. By understanding the complexity and the priorities in urban development process, all problems of the urban development projects can be solved or improved. These priorities are specified using AHP (Analytic Hierarchy Process). A questionnaire survey is employed to identify the problems of urban development process and the methods of revitalizing urban in this research. Through the survey, 35 issues are drawn out. Factor analysis technique is applied to extract the underlying interrelationships possibly existing. Using latent root criterion and varimax rotation method, 9 factors are extracted(by using 34 issues after deleting 1 issue less than 0.4 of factor loading) These 9 factors named as PIF (Problem Improvement Factor) consist of integration estimation (PIF1), cooperation operation capability (PIF2), contractor corporation capability (PIF3), capital for infrastructure investment (PIF4), misunderstanding of effective land use (PIF5), financial capability (PIF6), obscure goal of project (PIF7), shortage of cooperation expertise (PIFS), administrative procedures (PIF9). PIF 6 is the most important factor and PIF 1 is the most widely effective factor to succeed urban land development projects. It is recognized that administrative office is most responsible for PIF1 cooperation is most responsible for PIF2, 7, 8 and 9; contractors is most responsible for PIF3 and PIF6; administrative agencies is most responsible for PIF4; cooperation and consultants are responsible for PIF5. From findings in this study, some suggestions are proposed for the revitalization methods of urban development projects through the land readjustment method.

Suggestion for Legal Definitions of Keywords on Soil Contamination Policies in Korea (토양환경보전법의 토양오염 관련 주요 용어의 정의 및 재정립에 관한 고찰)

  • Park, Yong-Ha;Yang, Jae-E.
    • Journal of Environmental Policy
    • /
    • v.4 no.1
    • /
    • pp.39-67
    • /
    • 2005
  • In order to properly define the terms such as soil, soil contamination, soil contamination site and remediation, which are the key terms under the Soil Environment Conservation Act(SECA) in Korea, we analyzed the legal definitions of the similar key words in legislations of the developed western countries. The selected countries were the United States of America, the United Kingdom, the Netherlands, Germany, and Denmark. The legal definitions of these keywords were very much diversified due to different levels of soil contamination, as well as different industrial, social, and legal backgrounds in each country. However, fair suggestions for definitions of the key terms in SECA were derived from the comparative analyses of these countries. First and foremost, SECA should provide a definition of 'soil' which includes a concept of the natural soil layer produced from soil mineralization processes. Groundwater and sublayer of the groundwater would. be excluded in the boundary of the soil with regards to the Groundwater Act of Korea. Definition of 'soil contamination' of SECA should include a concept of risk assessment(soil contaminants, pathway, and receptors), purpose of land use, and the acquired limitation levels of soil contaminants. Soil contamination activity either industrial or anthropogenic in SECA article2-1, could be substituted for a concept of soil risk assessment. Definition of 'soil contamination site' could derive from amalgamating the concepts of i) soil contamination in conjunction with contaminants, ii) risk assessment, iii) a concept of land use, and iv) knowing limitation of contamination site designation. Definition of 'remediation of contaminated site' should include the objective, intention, action, methodology and limit of the remediation. These suggested definitions would increase the efficacy of soil environment conservation policies, which includes the survey of the potentially contaminated area, remediation, and removal of the site.

  • PDF

불공정거래행위 규제에 대한 발전적 입법론에 대하여

  • An, Byeong-Han
    • Journal of Korea Fair Competition Federation
    • /
    • no.150
    • /
    • pp.14-29
    • /
    • 2010
  • 비록 부정경쟁방지법의 제정 목적이 부정경쟁행위 등의 방지를 통하여 건전한 거래질서를 유지한다는 의미의 경쟁체제 확립에 있기는 하지만, 우리나라의 경우는 법 제정 당시와는 달리 사실상 산업스파이에 대한 영업비밀의 보호나 주지의 상표 영업표지의 보호와 같은 지적재산권의 보호 법률로서의 역할로 점차 변화하고 있고, 특히 부정경쟁방지법이 주지의 상표에 대한 출처의 혼동에 대한 규제뿐만이 아니라 별도로 저명상표의 희석화(稀釋化) 방지라는 법익, 이에 더 나아가 도메인 네임(Domain Name)의 선점과 원산지 및 품질의 오인(誤認) 야기행위, 주지 저명한 타인의 디자인(Design), 캐릭터(Character)와 같은 상품의 표지에 이르기까지 지적재산권과 관련된 보다 넓은 법익의 보호까지 수행하게 되면서 그 기능은 날로 강화되고 있는 상태이다. 이에 반하여 부정경쟁방지법상의 부정경쟁행위 자체에 대한 규제는 사실상 주지 저명한 타인의 상표나 상품표지의 식별력이나 출처표시기능 등의 보호라는 의미의 분쟁수준을 넘지 못하고 있어, '경쟁법'으로서의 역할은 상대적으로 미약해지고 있는 것 또한 현실이다. 또한, 공정거래법 제23조 제1항 제8호를 비롯하여 현행 공정거래법상의 불공정거래행위에 대한 규정체제를 살펴보면, 해석 여하에 따라서는 부정경쟁방지법상의 부정경쟁행위가 대부분 공정거래법상의 불공정거래행위의 범위 내로 포섭될 수도 있는 상황이기도 하다. 이에 양 법률의 성격과 역할, 앞으로 나아가야 할 방향을 고민하지 않을 수 없고, 이와 같은 논의는 발전적 입법론으로서의 가치를 갖는다. 물론 불공정거래행위(부정경쟁행위)에 대한 규제에 있어서 반드시 독일법체계에 따를 것인지 아니면 미국의 경우를 따를 것인지에 대한 선택 자체가 논리적으로 양립 불가능한 것은 아닐 것이지만 우리나라의 경우는 1980년 "독점규제 및 공정거래에 관한 법률"이 제정되는 과정에서 당시 부정경쟁방지법에 담겨 있던 기존의 부정경쟁행위에 대한 규정과 공정거래법상의 불공정거래행위와의 경합이나 중복문제는 마땅히 검토되었어야 했음에도 불구하고 공정 거래법의 제정과정에서 사실상 부정경쟁방지법의 존재 자체가 간과되어 오늘에 이르고 있다. 그동안 양 법률상의 규정 중복이나 충돌을 정식으로 문제 삼았던 바는 없었지만 '발전적 입법론' 이라는 차원에서 살펴 보면 부정경쟁방지법상의 부정경쟁행위에 대한 규제는 앞으로 공정거래법체계 내의 불공정거래행위로 포섭할 필요가 있고 이를 통하여 경쟁정책의 전문 전담기구로서 불공정거래행위에 대한 규제의 중심에 서 있는 공정거래위원회를 중심으로 효율적이고 통일적인 경쟁정책을 확립을 기대하여 볼 수 있을 것이다. 이 과정에서 공정거래법의 변화 또한 뒤따라야 하는데, 부정경쟁방지법상의 부정경쟁행위의 편입에 따라 불공정거래행위에 대한 규정 일부를 알맞게 다시 수정하는 것에 그치지 않고, 기존 부정경쟁방지법이 인정하고 있었던 사인간(私人間) 금지 또는 예방청구권 또한 공정거래법으로 그대로 편입되는 방향으로의 입법 개선이 이루어질 필요가 있으며, 그동안 '부정경쟁방지법의 공정거래법으로의 편입문제'와는 전혀 무관하게 공정거래법의 사적 구제 및 사소(私訴)의 활성화 차원의 논의로서 공정거래법상 사인간 금지청구권의 도입 여부가 검토되어 왔지만, 앞으로 이 문제는 부정경쟁방지법상 부정경쟁행위의 공정거래법체계 내로의 편입문제와 함께 이를 포함한 더욱 큰 논의로서 다시 적극적으로 검토될 필요가 있다고 본다. 이를 통하여 앞으로 부정경쟁방지법은 특허청을 중심으로 산업스파이에 대한 규제나 영업비밀의 보호와 기타 지적재산권의 보호에 온 힘을 다하고, 공정거래법은 공정거래위원회를 중심으로 불공정거래행위 (부정경쟁행위에 대한 보다 포괄적이고 통일적인 규제를 담당하여 '선택과 집중' 이라는 차원의 각 법률체계의 한 차원 높은 발전 또한 기대해 볼 수 있을 것으로 확신한다. 이러한 합의점을 시작으로 미시적인 다음 단계의 논의에 해당하는 사인간 금지청구권의 허용범위나 허용요건, 남용을 방지하기 위한 제도적 장치, 단체소송 등의 허용 여부 등의 논의도 함께 하여야 할 것이고, 이 과정에서 미국의 클레이튼법(Clayton Act)이나 가까운 일본의 입법례를 참고하여 우리의 실정에 맞는 규제의 틀을 마련함이 타당할 것이고, 이를 통하여 궁극적으로 그동안 공정거래법의 사적 집행의 활성화를 통한 경쟁질서의 확립의 강화라는 이상에 더욱 가까워질 수 있는 좋은 입법적 변화의 모습을 볼 수 있을 것이라 생각한다.

  • PDF

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.