• Title/Summary/Keyword: 효율저감한계

Search Result 102, Processing Time 0.03 seconds

Workflow Procedures and Applications in BIM-based Design for Safety (DfS) (BIM 기반 설계안전성검토의 업무 절차와 활용 방안에 관한 연구)

  • Jaewoong Hwang;Heetaek Yoon;Junhyun Bae;Youngkon Park
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2024
  • A conventional Design for Safety (DfS), introduced to eliminate potential hazards in the design phase proactively, has encountered persistent challenges, such as perfunctory risk assessments and hazard identifications based on 2D drawings and inefficient workflow processes. This study proposes a BIM-based approach to Design for Safety (DfS) to address the limitations of conventional methods, aiming to enhance efficiency and achieve practical safety management benefits. The proposed workflow process for BIM-based DfS has been refined and validated for on-site applicability through various case studies, including risk assessments during the design phase and field applications for safety management activities during the construction phase. Specifically, the critical process of risk assessment within the DfS methodology has also been transitioned to a BIM-based approach. This BIM-based risk assessment process has been evaluated through case studies, encompassing safety reviews for structural design, construction equipment operation, and construction methodology with sequence in design projects. Additionally, the proposed BIM-based DfS has demonstrated exceptional on-site applicability and efficiency, as validated by the application of a BIM deliverable embedded in DfS information for CDE-based daily activity briefing, VR-based safety training, AR-based mitigation measures inspections, and other safety management activities in the construction phase.

Analysis of the Flood Discharge Measurement and Flood Stage Reduction Effect by the Stream Detention Basins (제주도 홍수유량 계측 및 저류지 홍수위 저감효과 분석)

  • Kim, Dong-Su;Yang, Sung-Kee;Yu, Kwon-Kyu;Kang, Meoyng-Su;Jung, Woo-Yul;Lee, Jun-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.170-170
    • /
    • 2012
  • 제주도는 최근 기후변화에 의한 태풍의 증가로 집중호우의 빈도가 지속적으로 증가하고 있는 추세이고 지난 태풍 나리로 인해 발생한 제주시에서의 극심한 재해로 태풍 시 홍수 유량 관측 및 저류지의 건설로 인한 저류효과의 분석에 많은 관심이 집중되고 있다. 제주대학교 주관의 제주도 물순환 해석 및 수자원 관리체계 구축 사업단은 제주도 환경에 적합한 유량조사기법을 적용 및 개발 중에 있으며 특히 집중 호우 시 유량 계측을 비롯한 제주 유량 자료 확보 방안에 대해 연구를 수행하고 있다. 제주도 연구단은 지난 여름 태풍 무이파 때 제주시 하천의 제 2동산교에서 다양한 계측 방식을 활용하여 유량관측을 성공적으로 수행하였다. 태풍 무이파는 강한 중형 태풍으로 제주도 산간 지역에 700mm 이상의 집중호우를 보여 제주 하천에 많은 양의 유출을 발생시키고 일부 재산 및 인명 피해를 발생시켰다. 홍수 유량의 계측은 지금까지도 최적화된 계측 방식이 확립되지 못했고 그 측정의 어려움과 계측기기의 한계로 봉부자 같은 전통적인 방식의 홍수유량 측정방식이 여전히 통용되고 있는 현실이다. 하지만 본 연구단은 최신 관측기법인 비접촉식의 표면영상유속계와 전자파표면유속계를 사용하여 전 강우 지속시간 동안 유량을 매 시간마다 관측하여 수문곡선을 완성하여 홍수 유량 계측의 효율성과 정확성을 높일 수 있었다. 계측 결과 홍수유출 시 한천 상류의 제 1,2 저류지가 가동되어 저류효과가 수문곡선에 반영되었음을 알 수 있었고 홍수 유출 시 나타나는 대표적인 특이 경향이 수위-유량곡선의 이격현상도 확인할 수 있었다. 따라서 홍수 유출은 단순히 수위 자료만으로는 부족하고 유속자료를 동시에 관측해야 정확한 계측치를 확보할 수 있음을 알 수 있다. 또한 최신 계측기기인 표면영상유속계와 전자파표면유속계의 유속 관측값의 상호비교도 실시하여 관측기기의 효율성을 검증하였다.

  • PDF

Removal Efficiency of Pollutants in Agricultural Wastewater by Constructed Wetlands on Reclaimed Land in the Goheung Bay (고흥만 간척지 내 인공습지에 의한 농경배수 정화효율에 관한 연구)

  • Yu, Hun-Sun;Kang, Dong-Hwan;Kwon, Byung-Hyuk
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.37-47
    • /
    • 2009
  • This research was conducted at the constructed wetland in Goheung reclaimed land, and water quality components were measured at the 12 points in 15 March 2008 and 10 January 2009, respectively. Temperature, pH, DO, EC and salinity components were measured at the field, and TOC, Cl-, COD, TSS, T-P and TN components were analyzed laboratory. Concentrations of field measured components at inflow points were higher than in constructed wetland. TOC concentration ratio of inflow water to constructed wetland water was higher in January, and Cl concentration ratio of it was higher in March. And, COD concentration ratio of it were 1.37 for March and 1.49 for January, respectively. T-P and T-N concentration ratios of it at inflow points were higher 3 times than in constructed wetland. Constructed wetland attenuated concentration of contaminated components inflow to it. Removal efficiencies of Cl-, T-P and T-N components in inflow water were high at the constructed wetland. removal efficiencies of Cl component were 83% for 1st monitoring and 76% for 2nd monitoring, this removal efficiency be caused by dilution effect of constructed wetland. removal efficiencies of T-P component were 67% for 1st monitoring and 69% for 2nd monitoring, and they of T-N component were 100% for 1st monitoring and 95% for 2nd monitoring. Abnormal removal efficiency of T-N component is caused that nitrogen in inflow water was a little. Removal efficiency of T-P component was higher in January, and T-N component was higher in March. This is caused by environmental difference between growing season and winter.

  • PDF

Improved Degree of Freedom of Magnetic Induction Wireless Charging Coil Using Proposed Double Coil (이중코일을 이용한 자기유도 무선충전 코일의 자유도 개선)

  • Choi, Bo-Hee;Nam, Yong-Hyun;Chung, Habong;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.907-914
    • /
    • 2018
  • Wireless charging has been actively researched and popularized owing to the potential convenience of being able to charge electronic devices without wires for users. However, the receiver on the wireless charging pad is not charged when the center of the receiver is misaligned; thus, the center of the receiver must be adjusted well. This misalignment may greatly reduce the convenience of wireless charging. To overcome this limitation of wireless charging, a coil is designed to improve the positional freedom of the receiver. The positional freedom of the Rx coil is improved when the outer diameter of Tx coil is larger than when Rx and Tx coils are almost the same size. When the Tx coil has a larger outer diameter than that of the Rx coil, the efficiency at the center is somewhat lowered, but the efficiency is improved compared to when the center is out of order. In this paper, a double coil structure having an outer and an inner coil is proposed. The double coil structure further improves the efficiency, compared with one coil with the same outer size. The simulation and measurement results demonstrated that the tendency was consistent, and it was verified that the degree of freedom of the Rx coil is improved by adding the inner coil, while the size of the outer coil was the same. The measurement shows that the transmission efficiency of the conventional Tx coil is 37 %, the larger outer diameter coil is 45 %, and double coil is 47 % when the distance of the Tx/Rx coil is 3 mm, the misalignment is 15 mm and current flowing in the Rx coil is 1 A at an operating frequency of 105 to 210 kHz.

Effect of Paddy BMPs on Water Quality and Policy Consideration in Saemangeum Watershed (새만금 유역에서 논 최적관리기법의 수질개선 효과와 정책고려사항)

  • Kim, Jonggun;Lee, Suin;Shin, Jae-young;Lim, Jung-ha;Na, Young-kwang;Joo, Sohee;Shin, Minhwan;Choi, Joongdae
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.304-313
    • /
    • 2018
  • Agricultural land reclamation in Saemangeum tidal land project is mostly planned to be completed by 2020. Irrigation water for the land is required to be prepared by that time. However, water quality for the irrigation sources is barely meet the target concentration. This paper described the reduction effect of and policy consideration for best management practices (BMPs) which were fertilizer prescription by soil test (SO#1), mixed application of SO#1 and 3 (SO#2), drainage gate control (SO#3), time-release fertilizer application (SO#4), and control (CT). Reduction of paddy runoff was relatively higher in SO#3 (25%) and SO#1 (27%) while lower in SO#4 (9%) and SO#2 (7%) than that in CT. In addition, farmers promised to follow the BMP guidelines but they didn't because of the several problems caused for the BMPs implementation. Thus, it recommended developing an automated control of irrigation gate and paddy water depth and supporing farmers for NPS pollution control and irrigation water reduction.

Using Next Generation Technologies to Resolve Construction Labor Shortage Problems (건설기능인력 수급 불균형 문제 해결의 대안 제시)

  • Lee, Bok-Nam;Woo, Sungkwon;Chang, Chul-Ki;Koo, Bon-Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6D
    • /
    • pp.969-974
    • /
    • 2006
  • Labor shortages are a serious problem for Korea's construction industry. The problem is both quantitative and qualitative. There is a shortage in supply as due to a decrease in the influx of new labor, and existing workers are less productive as they age. The problem will only get worse as more and more major public projects are being planned. Options for increasing the labor supply are somewhat limited, and thus efforts need to be made to adopt new technologies that can improve the productivity and efficiency of field work and their processes. This paper introduces seven innovation technologies that have the best potential to increase productivity and thus reduce the burden of labor shortage problems. These include 1) Substitution by use of robotics and automation, 2) development and applications of Innovative materials to reduce on site field work, 3) increase in productivity through the implementation of Information Technology, 4) improved productivity through the application of modules, and prefabrication, 5) prevention of rework and redesign, 6) diversification of labor by integrating labor skills, and 7) improved productivity by standardizing site processes.

Utilization of Electric Arc furnace Slag md Converter Slag after Aging for Concrete Aggregate (콘크리트용 골재로서 에이징처리한 제강슬래그외 활용)

  • 문한영;유정훈
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.4
    • /
    • pp.597-607
    • /
    • 2002
  • Electric arc furnace and converter slag are produced by about 6 millions tons in Korea at 2000 year. But compared with blast furnace slag, those are utilized only in unvalued material like landfill and road construction. There are unstable materials, like free CaO, in electric arc furnace and converter slag at steel-manufacturing process. This might cause volume expansion in concrete, if electric arc furnace and converter slag aggregates were used in concrete. This expansion may reach to crack or collapse of concrete. It is therefore settled by standard specification for concrete that electric arc furnace and converter slag aggregates have not to use in concrete. First of all, volume stability and stabilized process should be solved in electric arc furnace and converter slag aggregate to use in concrete. In this study, 6 types of aging are evaluated for effects of stabilization to reduce the expansion of electric arc furnace and converter slag. h converter slag aggregate, these types of aging are not good for volume stability for concrete aggregate, and even if converter slag aggregate is treated with aging, concrete with it has some problems that strength is reduced with curing days. But in electric arc furnace slag aggregate treated with hotwater and steam aging, the expansion of electric arc furnace slag aggregate is reduced about two times than that of converter slag aggregate, and electric arc furnace slag aggregate concrete has good results in strength compared with control concrete using crushed stone.

A Methodology for Evaluating Regional and Structural Safety to Each District (지자체별 지역 및 시설물별 안전도 평가 방안)

  • Park, Moo-Jong;Jun, Hwan-Don;Jung, Sang-Man
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.361-365
    • /
    • 2007
  • 자연재난은 발생원인에 따라 바람, 강우, 적설, 파고등으로 구분할 수 있다. 이러한 재난원인은 자연현상의 일부로 발생하였으나, 경제가 발전함에 따라 과거에 비해 재해에 안전한 사회를 요구하게 되어 재해저감을 위한 투자와 방재정책 개발의 필요성이 증대되고 있다. 기존에는 자연재난을 저감시키기 위하여 연최대치 강우를 통계 분석하고 강우-유출관계를 이용하여 장래에 발생할 홍수량을 예측하여 자연재난을 저감할 수 있도록 설계하는 것이 일반적인 재난저감계획 수립으로 간주되었다. 그러나, 재해예방을 위해서는 과거에 발생한 재난의 지역적 특성을 분석하여 재난발생 위험과 피해규모를 파악함으로써 재난계획 수립의 기초자료로 활용할 필요성이 있다. 이러한 자연재난에 대한 대책수립은 국가차원에서 필요하며 이를 위해서는 지역별 안전도 평가의 필요성이 증가하게 된다. 그러나 이러한 연구를 수행하기 위해서는 방대한 자료를 바탕으로 풍수해 발생특성을 분석하는 연구와 지자체 또는 지역별 재난피해저감 능력을 수치적으로 나타낼 필요성이 있다. 따라서, 공학적인 면뿐만 아니라 행정적인 면을 동시에 고려하는 학제간 연구가 필요하다. 본 연구에서는 우리나라에서 주로 발생하는 풍수해에 의한 자연재난 특성을 파악하고 재난발생 확률을 고려한 재난피해규모와 재난피해 저감능력을 비교하여 전국 234개 지자체별 지역 및 시설물별 안전도를 평가하고자 한다. 과거 10년간 재해연보에 수록된 지자체별 피해현황을 지자체별 특성을 고려하여 분석, 지자체별 연평균 피해규모를 소방방재청의 지역별 안전도 지침서에 의거, 10등급으로 분석하였다. 또한, 지자체별로 투자우선순위 및 방재예산편성의 효율성 극대화를 위해 지자체별 시설물별 피해현황을 분석하는 기법을 개발하여 지자체별 시설물별 안전도 진단지표를 설정하였다. 분석된 결과는 지자체별 시설물별 재해저감을 위한 풍수해저감 종합계획 재난보험제도 도입등의 기초자료로 적용될 수 있다.로 나타났다. 이는 두 흐름에 의해 와(vortex)가 크게 형성되어 하상의 세굴에 영향을 미치기 때문으로 판단되었다.보다 본질부가 차지하는 면적이 월등히 적고 제1차 및 제2차섬유가 차지하는 면적이 많았다. 따라서 고섬유함량인 대마의 품종개량에 있어서는 가능한 한 본질부가 차지하는 면적은 축소시키고 제1차 및 제2차섬유가 차지하는 면적은 증대시켜야 할 것으로 본다.우리 나라 수도의 작기는 앞으로 당기는 것이 좋다고 고찰된다. 6. 우리 나라의 현행 수도작기로 본 기온 및 일조조건은 수도의 분얼전기에 대해서는 호조건하에 놓여 있으나, 분얼후기인 7월 중ㆍ하순 경의 일조부족과 고온다습조건은 병해, 특히 도열병의 유발원인이 되고 있다. 7. 우리 나라의 현행수도작기로 본 전국각지의 수도의 출수기는 모두 일조시간이 적은 부적당한 시기에 처해 있다. 8. 출수후 40일간의 평균기온에 의한 적산온도 88$0^{\circ}C$의 출현기일은 수원에서 8월 23일이었고, 년간편차를 고려한 안전출수기일은 8월 19일로서 적산온도면에서는 관행 출수기일은 약간 늦다고 보았다. 9. 등열기의 평균기온에 의한 적산온도는 현행 수도작기로서는 최종한계시기에 놓여 있으며, 평균기온의 년간편차와 우리 나라의 최저기온이 낮은 점을 고려할 때, 현행출수기는 다소 늦은 것으로 보았다. 10. 생육단계별의 수도체내의 질소함량은 영양생장기의 질소함량이 과다하였으며, 출수 이후에 영양조락을 여하히 방지하느냐가 문제된다고 보았다. 11. 수리불안전답 및 천수답이 차지하는 전답면적의 비율은 차차 감소되고 있는데, 이와 전체 10a당 수량의 증가율과의 상관계수를 산출하였는데, 수리불안전답과의 상관계수 (4)는 +0.525였으며, 천수답과는 r=+0.832, 그리고 수리불안전답과 천수답을 합계한 것과의 상관계수 (r)는 +0.841로서 후2자와는 고도의 정(+) 상관을 보여 천수답이 차지하는 면적비율이 작

  • PDF

Flood Simulation for Basin-Shaped Urban Watershed Considering Surface Flow (분지형 도시유역에서의 노면류를 고려한 침수모의)

  • Ahn, Jeonghwan;Cho, Woncheol;Jung, Jaehee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.841-847
    • /
    • 2014
  • Urban runoff models have been continuously developing with concerns for urban flood. Recently, models that be able to quantitatively analyze surface inundation caused by overflowed water from storm sewer were also developed by coupling 1-dimensional sewer model and 2-dimensional surface flow model. However, only overflowed water from storm sewer can be analyzed by the models have been developed until now. They are limited to be not able to analyze surface inundation caused by surface runoff that could not flow into the storm sewer. In order to overcome the limitation, basin-overlap method was devised adding a dummy 1-dimensional sewer layer to the model, so it can consider the efficiency of inflow to the storm sewer system. XP-SWMM 2011 is applied for urban runoff model and the flood event occurred on July 27, 2011 in basin-shaped Sadangcheon watershed is chosen for study inundation event. According to simulation results basin-overlap method reappear the observed inundation event more precisely than traditional method. This results suggest that drainage system has to be improved for reducing inundation caused by surface runoff and would be used as considerations for planning an urban basin design magnitude.

Optimal Flow Rate Evaluation for Low Energy, High Efficiency Cleaning of Forward Osmosis (FO) (정삼투 공정의 저에너지 고효율 세정을 위한 최적 유속 평가)

  • Kim, Yihyang;Kim, Jungbin;Zhan, Min;Min, Dahae;Hong, Seungkwan
    • Membrane Journal
    • /
    • v.29 no.6
    • /
    • pp.339-347
    • /
    • 2019
  • Forward osmosis (FO) is operated at a lower pressure than reverse osmosis (RO), which has great advantages in terms of fouling control, maintenance, membrane cleaning, and potential energy reduction. In particular, since the membrane fouling layer of the forward osmosis process has a relatively loose and dispersed property, it is possible to control the membrane fouling by physical cleaning, unlike the reverse osmosis process. However, existing studies do not apply the proper cleaning flow rate for forward osmosis physical cleaning, and thus there is a limit that the optimal operation can not be performed. Therefore, this study aims to evaluate the justification of proper flow rate that can show high efficiency cleaning with economical energy amount. The membrane fouling experiments of the forward osmosis process were maintained at a circulating flow rate of 8.54 cm/s and the recovery rates were compared with the three cleaning flow rates. As a result of this experiment, it was confirmed that the 2 × speed cleaning showed the same efficiency as the water permeability recovery rate of the 3 × speed cleaning, and it was confirmed that the 2 × speed cleaning was an appropriate flow rate with high cleaning efficiency and economical SEC.