• Title/Summary/Keyword: 횡단기체

Search Result 14, Processing Time 0.029 seconds

Radial Variation of Sound Absorption Capability in the Cross Sectional Surface of Yellow Poplar Wood (백합나무 횡단면 흡음성능의 방사방향 변이)

  • Kang, Chun-Won;Lee, Youn-Hun;Kang, Ho-Yang;Kang, Wook;Xu, Huiran;Chung, Woo-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.39 no.4
    • /
    • pp.326-332
    • /
    • 2011
  • Radial variation of sound absorption capability and air permeability of yellow poplar (Liriodendron tulipifera) wood in cross sectional surface and effect of steam explosion treatment were estimated by the two microphone transfer function method and the capillary flow porometry, respectively. The sound absorption coefficients of steam explosion treated wood was higher than those of control wood and these values increased with frequency. Abundant and big vessel may behave as sound absorbing pore observed on the cross sectional surface of yellow poplar wood. The sound absorption coefficients and air permeability of sapwood were higher than those of heartwood for Liriodendron tulipifera.

Properties of Longitudinal & Transverse Discharge in a Tubular Fluorescent Lamp (직관형 형광램프의 종단방전과 횡단방전의 특성)

  • Chung, J.Y.;Kim, J.H.;Jeong, J.M.;Jin, D.J.;Kim, H.C.;Bong, J.H.;Hwang, H.C.;Lee, M.S.;Koo, J.H.;Cho, G.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.4
    • /
    • pp.322-330
    • /
    • 2008
  • The properties of discharge, luminance, and spectroscopy are investigated in a longitudinal and transverse discharge fluorescent lamps with tube of outer diameter 4 mm. The sample lamps are prepared to be three kinds of gas composition such as mercury lamps of Ne(95%)+Ar(5%)+Hg(2 mg), the mercury-free lamps of Xe 100% and Ne+Xe(4%). The gas pressure is in the range of $5{\sim}300\;Torr$. In the mercury lamps, the longitudinal discharge having a positive column is high in luminance and efficiency, while the transverse discharge is no luminance at all. In the Xe-lamps, the transverse discharge shows relatively good in efficiency as compared with the longitudinal discharge which has a high discharge voltage and a low luminance and efficiency. In the transverse discharge of relatively high efficiency, a pure Xe(100%) gas discharge has a higher efficiency than the mixture gas of Ne+Xe(4%). Through these experiments, the properties of mercury and xenon lamps are verified. In the mercury lamps, the longitudinal discharge of tubular fluorescent lamps is high in luminance and efficiency, while the transverse discharge of flat panel fluorescent lamps are low in luminance efficiency. In the mercury-free lamps, the flat fluorescent lamps of transverse discharge having a high pressure ${\sim}100\;Torr$ with the pure Xe-gas are verified to be suggestable.

Effect of Injection Angle and Length to Diameter Ratios on Drop and Penetration Characteristics in Cross-flow (아름속 횡단 기체 유동장에서 노즐 형상 변화와 분사각 변화가 액적크기와 침투거리에 미치는 영향)

  • Lee, Bong-Soo;Ko, Jung-Bin;Cho, Woo-Jin;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.51-58
    • /
    • 2006
  • The spray characteristics of liquid jet injected into subsonic cross-flow were investigated experimentally. Spray trajectories were captured using CCD camera. Droplet sizes were measured using PDPA and Image Express. The nozzle diameter was 0.5 mm, and its length-to-diameter ratios (L/D) ran$4.11{\times}10^6$ged from 1.0 to 6.0. Experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration length is decreased by increasing Weber number. At low injection angle(${\theta}$ < $90^{\circ}$), Weber number is dominant parameter for trajectories, but at high injection angle(${\theta}$ > $90^{\circ}$), L/D is dominant parameter for trajectories rather than Weber number.

Characteristic of Liquid Jet in Subsonic Cross-flow (횡단가스 유동에 분사되는 액체제트의 분무특성)

  • Ko, Jung-Bin;Lee, Kwan-Hyung;Koo, Ja-Ye
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • The present study has numerically and experimentally investigated the spray behavior of liquid jet injected in subsonic cross-flow. The corresponding spray characteristics are correlated with jet operating parameters. The spray dynamics are known to be distinctly different in the three regimes: the column, the ligament and the droplet regimes. The behaviors of column, penetration and breakup of liquid jet have been studied. Numerical and physical models are base on a modified KIVA code. The primary atomization is represented by a wave model base on the KH(Kelvin-Helmholtz) instability that is generated by a high interface relative velocity between the liquid and gas flows. In odor to capture the spray trajectory, CCD camera has been utilized. Numerical and experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration decreases by increasing Weber number.

  • PDF

Effect of Gas-liquid Ratio on Characterization of Two-Phase Spray Injected into a Cross-flow (횡단유동에 분사된 이유체 분무의 기체 액체비가 분무특성에 미치는 영향)

  • Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Su;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • The effect of two-phase spray injected into subsonic cross-flow was studied experimentally. External-mixing of two-phase spray from orifice nozzle with L/d of 3 was tested with various air-liquid ratio that ranges from 0 to 59.4%. Trajectory of spray and breakup phenomena were investigated by shadowgraph photography. Detailed spray structure was characterized in terms of SMD, droplet velocity, and volume flux using PDPA. Experimental results indicate that penetration length was increased and collision point of liquid jets approached to nozzle exit and distributions of mist-like spray were obtained by increasing air-liquid ratio.

Experimental Study of Spray Characteristics of Liquid jet in Cross-flow (횡단류를 이용한 액체제트의 분무 및 분열 특성 실험)

  • Ko Jung-Bin;Lee Kwan-Hyung;Moon Hee-Jang;Koo Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.155-158
    • /
    • 2005
  • The spray characteristics of liquid jet minted in subsonic cross-flow were investigated numerically and experimentally. The behaviors of column, penetration and breakup of plain liquid jet in non-swirling cross-flow of air have been studied. Numerical and physical models are based on a modified KIVAII code. The primary atomization is represented by a wave model based on the KH(Kelvin-Helmholtz) instability that is generated by a high interface relative velocity between the liquid and gas flows. CCD camera has been utilized in oder to capture the spray trajectory. The nozzle diameter was 0.5 mm and its L/D ratios were between 1 and 5. Numerical and experimental results indicate that the breakup point is delayed by increasing gas momentum ratio, the penetration decreases by increasing Weber number and the turbulent or nonturbulent liquid jet is obtained at different L/D ratio.

  • PDF

Spray Characteristics of Two-Phase Flow Jets into a Subsonic Crossflow (아음속 횡단류로 분사되는 이상유동 제트의 분무특성)

  • Lee, Keunseok;Lee, Wongu;Yoon, Youngbin;Ahn, Kyubok
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.27-34
    • /
    • 2019
  • An experimental study on the spray characteristics of aerated-liquid jets discharged from effervescent injectors to a subsonic crossflow was conducted to investigate effects of a gas to liquid mass ratio (GLR) and a ratio of the orifice length to the diameter (L/d). The present effervescent injectors consist of a plain orifice injector and an aerator. To analyze breakup length and spray trajectory, instantaneous spray images were taken by a high speed camera. As the GLR increased, the spray penetration became higher under the same liquid mass flow rate and the breakup length became shorter due to the bubble expansion or the annular liquid film breakup. To predict the spray trajectory of two-phase flow jets into the crossflow, the homogeneous and the separated flow models were compared.

LES of Breakup and Atomization Characteristics of a Liquid Jet into Cross Turbulent Flow (난류 횡단류에 수직 분사 되는 액주의 분열 및 기화 특성에 관한 LES)

  • Yang, Seung-Joon;Koo, Ja-Ye;Sung, Hong-Gye;Yang, Vigor
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • LES(Large eddy simulation) of breakup and droplet atomization of a liquid jet into cross turbulent flow was performed. Two phase flow of gas and liquid phases were modeled by the mixed numerical scheme of both Eulerian and Lagrangian methods for gas and liquid droplet respectively. The breakup process of a liquid column and droplets was observed by implementing the blob-KH wave breakup model. The penetration depth into cross flow was comparable with experimental data for several variants of the liquid-gas momentum flux ratio by varying liquid injection velocity. SMD(Sauter Mean Diameter) distribution downstream of jet was analyzed.

Characteristics of SMD and Volume Flux of Two-phase Jet Injected into Cross-flow with Various Gas-liquid Ratio and Reynolds Number (횡단 유동장의 기액비 및 레이놀즈수 변화에 따른 외부혼합형 이상유체 제트의 액적크기 및 체적유속 특성)

  • Kim, Jong-Hyun;Lee, Bong-Soo;Koo, Ja-Ye
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2009
  • A study was performed to investigate the characteristics of two-phase jet injected into subsonic cross-flow using the external mixed gas blast two-phase nozzle. The shadowgraph method was adopted for the cross-flow jet visualization and PDPA system was used to measure droplet size, velocity, and volume flux. The atomization of two-phase jet is initially determined according to gas to liquid mass flow-rate ratio and the Reynolds number of cross-flows. The highest penetration trajectories of two-phase jet injected into cross-flow are governed by the momentum ratio at subsonic cross-flow. As GLR of two-phase jet injected into cross-flow increases, the droplet size decreases and the distribution area of volume flux increases. The distribution of volume flux that influenced by the counter vortex pair at the downstream of cross-flow is symmetric in shape of horseshoe.

Characteristics of Air-assist Spray Injected into Cross-flow with Various Gas-liquid Ratio (횡단유동으로 분사하는 이유체노즐의 기체-액체비에 따른 분무특성)

  • Cho, Woo-Jin;Lee, In-Chul;Lee, Bong-Su;Lee, Hyo-Won;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.159-162
    • /
    • 2007
  • The characteristic of air-assist spray injected into subsonic crossflow were studied experimentally. External-mixing air assist injector of Orifice nozzle with L/d of 3 were tested with various air-liquid ratio. Shadowgraph photography was performed for spray visualization and trajectory of spray measurements. The detailed spray structure was characterized in terms of SMD, velocity, and volume flux, using PDPA. Experimental results indicate that penetration length was increased and spray distribution was accelerated by increasing air-liquid ratio.

  • PDF