• Title/Summary/Keyword: 횡골절

Search Result 10, Processing Time 0.036 seconds

Patellar fracture after transverse screw fixation in sports athletes - A case report - (운동선수에서 횡방향 나사 고정 후 발생한 슬개골의 골절 - 증례 보고 -)

  • Ra, Ho Jong;Kim, Sung Tae;Ha, Jeong Ku;Kim, Jin Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.109-112
    • /
    • 2011
  • Anatomical reduction and strong fixation in displaced patella fracture are needed for restoration of knee function and strength and early range of motion exercise. According to the type of fracture and various operational methods, their many complications have been reported. We report 2 cases of transverse patella fracture which were caused by transverse screw fixation in longitudinal patella fracture and fracture of bipartite patella in athletes.

  • PDF

Arthroscopic Reduction and Internal Fixation with Cannulated Screw of a Transverse Glenoid Fracture (유경 나사를 이용한 견갑골 관절와 횡골절의 관절경적 정복 밑 내고정)

  • Noh Kyu Cheol;Yoo Jung Han;Kang Ki Man
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.176-180
    • /
    • 2003
  • We describe in this report the accurate reduction of a transverse displaced glenoid fracture through arthroscopic control . We used the lateral and superior (Neviaser portal) portal of the arthroscopic surgery in the shoulder joint for the U 4.0-mm titanium cannulated cancellous screw fixation. The advantages of this treatment are excellent intra-articular visualiBation, decreased soft tissue dissection ,less blood loss, shortened postoperative recovery and early ROM exercise. There(ore, we report the method of operation and the cases .

  • PDF

Treatment of Transverse Patella Fracture with Minimally Invasive Load-Sharing Patellar Tendon Suture and Cannulated Screws (최소 침습 기법 슬개건 부하 분산 봉합술과 유관 나사못을 이용한 슬개골 횡골절의 치료)

  • Lee, Beom-Seok;Park, Byeong-Mun;Yang, Bong-Seok;Kim, Kyu-Wan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.540-545
    • /
    • 2021
  • A transverse fracture is the most common type of displaced patella fracture requiring surgery. These fractures are commonly fixed with parallel Kirschner wires or screws that cross the fracture line, often with an additional tension band. Nevertheless, conventional fixation methods of patella fractures have prevalent complications caused by the protrusion of wires or pins. These complications necessitate additional surgery for hardware removal, increase medical cost, and can limit the function of the knee joint. This paper reports cases treated with a minimally invasive load-sharing percutaneous suture of the patella tendon. The procedure provides reliable fixation for transverse patella fractures, minimizes soft tissue injuries, preserves blood flow, and reduces postoperative pain. In addition, the procedure also reduces the irritation and pain caused by the internal fixture, thereby reducing the risk of restricted knee joint movement.

Dual Plate Fixation for Displaced Transverse Fracture of the Lower Sacrum (전위된 하부 천골 횡골절에 대한 이중 금속판을 이용한 내고정술)

  • Choi, Dong-Hyuk;Park, Ji-Hun;Shim, Seong-Woo;Choi, Yong-Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.2
    • /
    • pp.178-182
    • /
    • 2020
  • Isolated fractures of lower sacrum are commonly treated conservatively in most cases because of low energy damage and stable fracture. However, surgical treatment is required in displaced unstable fracture. But the surgical technique is not established and even case reports are not common. We reported a case of displaced transverse fracture of the lower sacrum that was treated with an open reduction and dual plate fixation.

A Clinical Study of Femur Neck Fractures (대퇴 경부 골절의 임상적 고찰)

  • Koo, Hwan-Mo;Ahn, Myun-Whan;Ihin, Joo-Choul
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.1
    • /
    • pp.69-80
    • /
    • 1990
  • A clinical analysis was done on 23 patients(24 hips) with fracture of the femoral neck, who had been admitted and treated at our Orthopedic department during the period of 4 years, from Jan, 1984 to May 1988. The results were as follows : 1. 23 patients were comprised of 4 males and 19 females, and 11 patients were over 65 years old. 2. 18 cases of 24 cases were due to minor traumas such as slipping down, and for over 65 years old, all cases were due to simple minor traumas, 8 cases were showed a severe osteoporosis, below grade 3 of the Singh's index. 3. 14 cases of 24 cases were displaced subcapital fractures, and 6 cases displaced transcervical fractures. Only 4 cases were the undisplaced transcervical fractures. 4. In treatment of fractures internal fixations after manipulation were performed in 14 cases and primary arthroplasties in 10 cases. Secondary arthroplasties were done in complicated 4 cases of 14 cases treated with internal fixations. 5. Complications after internal fixation were developed in 7 cases out of 14 cases, avascular necrosis in 6, nonunions in 2, pin migrations in 3, and metal failure in 1 case. 6. In 14 arthroplasty immediate surgical fitness of femoral stem were related to late loosening of femoral stem(correlation coefficient r=-0.68, p<0.01).

  • PDF

Arthroscopy Assisted Percutaneous Reduction and Screw Fixation of a Displaced Intra-articular Glenoid Fracture - A Case Report - (유경나사를 이용한 견갑골 관절와 골절의 관절경적 정복 및 내고정 - 증례 보고 -)

  • Ko, Sang-Hun;Jeon, Hyung-Min;Shin, Seung-Myeong
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.127-131
    • /
    • 2010
  • Purpose: The authors used arthroscopy-assisted percutaneous reduction and cannulated screw fixation rather? than conventional arthrotomy for displaced glenoid fracture. Materials and Methods: We used arthroscopy assisted reduction and screw fixation for a 66 year old man who had a clavicle fracture, a displaced glenoid fracture and a scapula fracture. Results: At 9 months postoperatively, the patient had recovered full range of motion and was not inconvenienced by the surgery. Removal of the implant was done 12 months post-operatively under general anesthesia. Conclusion: The advantages of arthroscopy-assisted percutaneous screw fixation are less pain and less bleeding, shorter hospital stay and earlier rehabilitation. Arthroscopic percutaneous screw fixation for a displaced glenoid fracture seems to be a good alternative treatment method.

The usefulness of CT for the diagnosis and the fragment fixation of anteroinferior tibiofibular ligament avulsion fracture in ankle fracture (족관절 골절에서 전하 경비 인대 견열 골절의 진단과 골편 고정술을 위한 전산화 단층 촬영의 유용성)

  • Na, Hwa-Yeop;Cho, Kook-Hee;Jung, Yu-Hun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.2
    • /
    • pp.78-85
    • /
    • 2011
  • Purpose: To evaluate the usefulness of computerized tomography (CT) for the diagnosis and the fragment fixation of anteroinferior tibiofibular ligament avulsion fracture in ankle fracture. Materials and Methods: We retrospectively studied 108 patients with an ankle fracture who had been checked with plain radiographs and CT from July 2006 to July 2010. They were divided into two groups; patients with (19 patients) and without (89 patients) an avulsion fracture of anteroinferior tibiofibular ligament. The two groups were evaluated with Lauge-Hansen classification, the energy of trauma, and the radiologic indices for syndesmotic injury, and were compared each other. Average follow up periods of two groups were 25 and 23 months each. Those who were unstable at stress test during surgery were divided into fragment fixation of anteroinferior tibiofibular ligament avulsion fracture group (8 patients) and transfixation one (11 patients) according to treatment method. Clinical and radiological results at last follow up were also compared. Results: Fourteen avulsion fractures of anteroinferior tibiofibular ligament were diagnosed by CT only. Incidences of pronation-external rotation injury, high energy trauma, positive radiologic indices for syndesmotic injury were significantly higher in patients with an avulsion fracture of anteroinferior tibiofibular ligament than those without it. Clinical and radiological results were satisfactory in both groups at last follow up, and were not significantly different between them. Conclusion: In patients who have an ankle fracture by pronation-external rotation injury, high energy trauma, or with positive radiologic indices for syndesmotic injury, CT is useful for diagnosis of an avulsion fracture of anteroinferior tibiofibular ligament. Fragment fixation of anteroinferior tibiofibular ligament avulsion fracture is a useful treatment option for syndesmotic injury.

  • PDF

Usefulness of Ultrasound in Treatment of Patella Fracture (슬개골 골절 치료에서 초음파의 유용성)

  • Kim, Jung-Man;Nam, Ho-Jin;Ra, Ki-Hang;Park, Se-Wook
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.26-31
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the clinical usefulness of ultrasound in treatment of patella fracture. Material and Methods: Twenty cases of twenty patients with patella fracture radiographically from March, 2006 to September, 2009 were involved in this study, there were 8 males and 12 females, there were 13 right knees, 7 left knees, the average age was 43 years (range, 14~72 years). We decided the methods of treatment by using the ultrasound in conjunction with Drayer's test that examining the intactness of patella retinaculum. There were 10 transverse, 8 vertical and 2 comminuted fractures, we examined the patella retinaculum by using the ultrasound and performed Drayer's test. Results: In 12 cases of intact retinaculum, Drayer's test was negative and we allowed patients ambulation without surgical fixation especially. In 4 cases of completely ruptured retinaculum, Drayer's test was positive and we treated the patella fractures by the use of ORIF (open reduction and internal fixation) method, in 2 cases of partially ruptured retinaculum, Drayer's test was negative but displacement of fractures were more than 2 mm, we treated the patella fractures by the use of CRIF (closed reduction and internal fixation) method and obtained clinically satisfactory results. Conclusion: In conjunction with radiographs and Drayer's test, an ultrasound would be one of the useful diagnostic modality for determining treatment method of the patella fracture.

  • PDF

Percutaneous Mini-open Reduction for Mason II or III Radial Head and Neck Fracture (요골 두 및 경부 골절의 경피적 도수 정복술)

  • Lee, Jeong-Gil;Koh, Il-Hyun;Kim, Hyung-Sik;Choi, Yun-Rak;Kim, Sung-Jae;Kang, Ho-Jung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.230-236
    • /
    • 2010
  • Purpose: We wanted to evaluate the result of percutaneous, mini-open reduction for the treatment of Mason II or III radial head and neck fractures. Materials and Methods: 13 patients (8 male, 5 female) with Mason II or III radial head and neck fractures were treated by 1 cm percutaneous mini-open reduction under fluoroscopy. The average age of our subjects was 29 years. Follow up duration was 18 months. Results: Union was noted in all cases. Mean radial neck angulation was decreased from 33.2 degrees to 7.8 degrees. The mean change in angulation between the immediate post-operative and last follow-up was 0.7 degrees. The mean range of motion at the elbow joint was at last follow up, 133.1 degrees in flexion, 7.3 degrees in extension, 80 degrees in pronation and 84.3 degrees in supination. Postoperatively, mean Mayo Elbow Performance Index, American Shoulder and Elbow Surgeons elbow score, and Disabilities of the Arm, Shoulder and Hand score were 96.2, 97 and 1.2. Temporary posterior interosseous nerve palsy (1 case) and minimal cubitus valgus deformity (1 case) were noted. Conclusion: Selected Mason II or III radial head and neck fractures can be treated satisfactorily with percutaneous mini-open reduction.

Correction of Atlanto-axial Instability by Avulsion Fracture of the Axis in a Dog (중쇠뼈 찢김골절로 인한 고리중쇠 관절 불안정의 교정)

  • Hwang, Yong-Hyun;Kim, Minkyung;Park, Jung-Hyun;Jin, So-Young;Park, Ki-Tae;Lee, Hee-Chun;Lee, Jae-Hoon
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.499-502
    • /
    • 2013
  • An eight-year-old, castrated male, Poodle dog was presented with a bite wound in the neck region. Clinical examination revealed non-ambulatory signs of tetraparesis with deep pain, and upper motor neuron changes in all limbs. Fractures of the transverse process of C1 and the dorsal spinous process of C2 were observed on the radiographs and the computed tomography (CT). Conservative therapy was performed for 1 week. However the neurological problems were not alleviated until 7 days after injury. The owners agreed to perform surgical stabilization. The surgical stabilization was performed 7 days after presentation. Ventral stabilization was performed with screws, K-wires and bone cement. The dog stood up independently after 4 weeks and was able to walk 6 weeks postoperatively. In this report we suggest that using combined stabilization techniques are effective for this type of cervical fracture in which the dorsal and ventral structures of the vertebra are severely disrupted.