• Title/Summary/Keyword: 획득 M&S

Search Result 580, Processing Time 0.034 seconds

Endoscopic Imaging and Fabrication of Micro-endoscope Catheter in Time-domain Optical Coherence Tomography (시간영역 광 간섭 단층촬영 시스템의 소형 엔도스코프 제작 및 영상구현)

  • Kim, Young-Kwan;Lee, Sung-Hun;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.206-213
    • /
    • 2010
  • We fabricated and characterized a compact endoscopic catheter for optical coherence tomography. The optical delay line (ODL), composed of a cylindrical piezoelectric transducer (PZT) and an optical fiber, was operated with a 1 kHz sinusoidal driving wave in the time-domain. When the ODL was driven with a sinusoidal wave function, the axial scanning speed was 6 m/s and the axial acquisition rate was 2000 line/s at a depth of about 3 mm. Endoscopic OCT images of a human finger and earhole were successfully obtained with an image rate of ten frames per second.

RUP Model Based SBA Effectiveness Analysis by Considering the V Process and Defense Simulation Hierarchy (V 프로세스와 국방시뮬레이션 모델유형을 고려한 RUP 모델 기반의 SBA 효과도 분석)

  • Cha, HyunJu;Kim, Hyung Jong;Lee, Hae Young
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.3
    • /
    • pp.55-60
    • /
    • 2015
  • This paper presents an SBA (simulation-based acquisition) effectiveness analysis environment using the RUP (Relational Unified Process) model. The RUP model has 4 phases which cover the whole development steps such as requirement analysis, design, development and test. By applying the RUP model, SW development can be represented with the iterations of developments for each phase. Such a characteristics of the model would make the model suitable for defense acquisition. In this paper, we show the relation between the RUP model and V process model, which is the foundation for defense acquisition. In order to show how the model could be applied to SBA effectiveness analysis, graphical user interfaces for the analysis are presented at the end of the paper.

A Study on the Application of M&S in the T&E of Weapon Systems (무기체계 시험평가에 M&S 적용방안)

  • Choi Seok-Cheol;Kim Sung-Kyue
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.4 s.19
    • /
    • pp.44-52
    • /
    • 2004
  • The test and evaluation(T&E) of weapon systems is a significant activity in the decision-making process of defense acquisition program, providing the data of trade-off analysis, risk reduction and readiness to advance to next phase of development for the decision-maker. Currently, the modeling and simulation(M&S) is being a critical method in the test and evaluation of weapon systems. Therefore in this paper we review the current status of the test and evaluation for the defense acquisition program in Korea, and suggest an application of M&S in the T&E of weapon systems.

Calibration of Gauge Rainfall Considering Wind Effect (바람의 영향을 고려한 지상강우의 보정방법 연구)

  • Shin, Hyunseok;Noh, Huiseong;Kim, Yonsoo;Ly, Sidoeun;Kim, Duckhwan;Kim, Hungsoo
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.19-32
    • /
    • 2014
  • The purpose of this paper is to obtain reliable rainfall data for runoff simulation and other hydrological analysis by the calibration of gauge rainfall. The calibrated gauge rainfall could be close to the actual value with rainfall on the ground. In order to analyze the wind effect of ground rain gauge, we selected the rain gauge sites with and without a windshield and standard rain gauge data from Chupungryeong weather station installed by standard of WMO. Simple linear regression model and artificial neural networks were used for the calibration of rainfalls, and we verified the reliability of the calibrated rainfalls through the runoff analysis using $Vflo^{TM}$. Rainfall calibrated by linear regression is higher amount of rainfall in 5%~18% than actual rainfall, and the wind remarkably affects the rainfall amount in the range of wind speed of 1.6~3.3m/s. It is hard to apply the linear regression model over 5.5m/s wind speed, because there is an insufficient wind speed data over 5.5m/s and there are also some outliers. On the other hand, rainfall calibrated by neural networks is estimated lower rainfall amount in 10~20% than actual rainfall. The results of the statistical evaluations are that neural networks model is more suitable for relatively big standard deviation and average rainfall. However, the linear regression model shows more suitable for extreme values. For getting more reliable rainfall data, we may need to select the suitable model for rainfall calibration. We expect the reliable hydrologic analysis could be performed by applying the calibration method suggested in this research.

The Evaluation of Usefulness of Pixelated Breast-Specific Gamma Imaging in Thyroid scan (Pixelated Breast-Specific Gamma Imaging(BSGI) 감마 카메라를 이용한 갑상선 검사의 유용성 평가)

  • Jung, Eun-Mi;Seong, Ji-Hye;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.90-93
    • /
    • 2011
  • Purpose: A Pixelated BSGI gamma camera has features to enhance resolution and sensitivity and minimize the distance between detector and organs by narrow FOV. Therefore, it is known as useful device to examine small organs such as thyroid, parathyroid and gall bladder. In general, when we would like to enlarge the size of images and obtain high resolution images by gamma camera in nuclear medicine study, we use pinhole collimator. The purpose of this study is to evaluate the usefulness of Pixelated BSGI gamma camera and to compare to it using pinhole collimator in thyroid scan which is a study of typical small organs. Materials and methods: (1) The evaluation of sensitivity and spatial resolution: We measured sensitivity and spatial resolution of Pixelated BSGI with LEHR collimator and Infinia gamma camera with pinhole collimator. The sensitivity was measured by point source sensitivity test recommended by IAEA. We acquired images considering dead time in BSGI gamma camera for 100 seconds and used $^{99m}TcO4-\;400{\mu}Ci$ line source. (2) The evaluation of thyroid phantom: The thyroid phantom was filled with $^{99m}TcO4-$. After set 300 sec or 100 kcts stop conditions, we acquired images from both pixelated BSGI gamma camera and Infinia gamma camera with LEHR collimator. And we performed all thyroid studies in the same way as current AMC's procedure. Results: (1) the result of sensitivity: As a result, the sensitivity and spatial resolution of pixelated BSGI gamma camera were better than Infinia's. The sensitivities of pixelated BSGI and Infinia gamma camera were $290cps/{\mu}Ci$ and $350cps/{\mu}Ci$ respectively. So, the sensitivity of pixelated BSGI was 1.2 times higher than Infinia's (2) the result of thyroid phantom: Consequently, we confirmed that images of Pixelated BSGI gamma camera were more distinguishable between hot and cold spot compared with Infinia gamma camera. Conclusion: A pixelated BSGI gamma camera is able to shorten the acquisition time. Furthermore, the patients are exposed to radiation less than before by reducing amount of radiopharmaceutical doses. Shortening scan time makes images better by minimizing patient's breath and motion. And also, the distance between organ and detector is minimized because detector of pixelated BSGI gamma camera is small and possible to rotate. When patient cannot move at all, it is useful since device is feasible to move itself. However, although a pixelated BSGI gamma camera has these advantages, the effect of dead time occurs over 2000 cts/s since it was produced only for breast scan. So, there were low concentrations in organ. Therefore, we should consider that it needs to take tests to adjust acquisition time and amount of radiopharmaceutical doses in thyroid scan case with a pixelated BSGI gamma camera.

  • PDF

Design of ILS M&S for RAM Analysis in Guided Weapon System (유도무기체계 RAM분석을 위한 ILS M&S 설계)

  • Lee, Yong-Bin;Lee, Dong-Wook;Lee, Joo-Hyung;Um, Chun-Sup;Park, Jang-Won
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.2
    • /
    • pp.19-29
    • /
    • 2015
  • M&S techniques are utilized for various purposes on the national defense, and its importance is increasing than ever. For analyzing RAM (Reliability, Availability and Maintainability) of weapon system, using M&S techniques can be more effective and practical way than deterministic approach, because M&S approach can consider uncertain variables and various constraints in the ILS (Integrated Logistics support) field. For design of ILS M&S, we first set up a purpose of M&S, attributes of real system and other similar ILS M&S tool. Then, we convert real system into model which consists of mathematical formula and logical expression. In this thesis, we introduce modeling procedures of M&S that describes total life cycle of 'OO guided weapon system' and the contents proposed in this paper can provide references for developing other M&S tool.

An Investigation on the Surface Flow Characteristics of Ogive-cylinder using the Infrared Ray Thermogram 3D Mapping Technique (적외선 온도 측정 3차원 매핑 기법을 이용한 오자이브 실린더 표면 유동 특성 파악)

  • LEE, Jaeho
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.4
    • /
    • pp.57-63
    • /
    • 2018
  • IR thermography is a non-invasive method and used for the visualization of the surface temperature of the model. However, this technique only derives 2D results and not quantitative data. The goal of this study is to apply the 3D mapping technique for IR thermography. The wind tunnel model is an ogive-cylinder with a wind speed of 20 m/s ~ 80 m/s and the angle of attack ranging from $0^{\circ}$ to $90^{\circ}$. The real location of the model was made to correspond with the position of the IR image using the makers. Based on this result, quantitative results were obtained. The 3D mapping method was verified by comparing the separation point and the theoretical value.

Information Acquisition of Simulation Objects by Resolution in Multi-resolution Model based War Game (다중 해상도 모델 기반 워게임 체계에서 해상도별 모의 객체의 정보 획득)

  • Bae, Hyun Shik;Rhee, Eun joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.1
    • /
    • pp.147-154
    • /
    • 2018
  • In this paper, we propose methods to acquire enemy object information, which is frequently required in multi-resolution model based war game and affects the simulation performance. In the information request method, a multi-resolution model selects information of a specific resolution and provides them to external objects. In the information announcement method, a multi-resolution model announces all information, and external objects select information of a specific resolution. In the information sharing method, external objects obtains information of a specific resolution by inquiring all information of a multi-resolution model which are stored in a shared space. Simulation results show that the information sharing method is more efficient than the information request method and the information announcement method because the information acquisition is fast. In addition, the proposed methods will increase the efficiency of war game operation by shortening the time for acquiring enemy forces' information.

P- and S-wave seismic studies in the Ulsan fault zone near Nongso-Eup (농소읍 부근 울산단층대에서의 P파 및 S파 탄성파 조사 연구)

  • Lee, Chang-Min;Kim, Ki-Young
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.95-100
    • /
    • 2006
  • To reveal subsurface structures of the Ulsan fault, seismic data were recorded along a 750-m long line near Nongso-Eup in Ulsan. P and S waves were generated simultaneously by impacting a 5 kg sledgehammer on a tilted plate. The data were received by 16 10-Hz 3-component geophones at 3 m intervals. Refracted P waves were inverted using the tomography method. Dip moveout and migration were applied to reflection data processed following a general sequence. Four layers were identified based on P-wave velocities and P- and S-wave stacked image. From top to bottom, the P-wave velocity of each layer ranges in $300{\sim}1100\;m/s$, $1100{\sim}1700\;m/s$, $1700{\sim}2700\;m/s$, and greater than 2700 m/s. The corresponding thickness of the top three layers averages 3.9 m, 5.9 m, 4.4 m, respectively. The S-wave stack section is effective to define subsurface structures shallower than 10 m.

  • PDF

Antimicrobial resistance and resistance transfer of Vibrio parahaemolyticus and Morganella morganii from commercial fisheries products (시판 수산물에서 분리한 Vibrio parahaemolyticus와 Morganella morganii의 항균제 내성과 내성 전이)

  • Lee, Ye Ji;Kim, Eunheui
    • Journal of fish pathology
    • /
    • v.32 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • The purpose of this study was to investigate the antimicrobial resistance and resistance transfer of Vibrio parahaemolyticus and Morganella morganii isolated from fish products purchased from fish markets in Yeosu April - December 2017. These bacteria were identified by biochemical test and PCR results, and the transfer of antimicrobial resistance was confirmed by the broth mating method. To isolate the transconjugants formed during conjugation, TSA medium containing 50 ㎍/ml of ampicillin (AMP), and 150 ㎍/ml of streptomycin (SM) or 30 ㎍/ml of oxytetracycline (OT) was used. M. morganii isolates showed low susceptibility to AMP, amoxicillin (AML), and colistin (CT), erythromycin, OT, and tetracycline, compared to V. parahaemolyticus resistance to AMP, AML, and CT. The conjugation of V. parahaemolyticus or M. morganii with Escherichia coli resulted in the separation of V. parahaemolyticus and M. morganii showing SM resistance as transconjugants. Meanwhile, Edwardsiella tarda transconjugants showing AMP and AML resistance were obtained from the broth mating of V. parahaemolyticus and E. tarda. But the transfer of the VPA0477 which is a β-lactamase gene of V. parahaemolyticus was not confirmed. These results suggest that resistance transfer between pathogenic bacteria is bidirectional and progresses in a wide variety of patterns.