• Title/Summary/Keyword: 회전식

Search Result 184, Processing Time 0.023 seconds

Effect of needle tip design and position, and irrigant flow rate on apical pressure (주사침 말단의 형상과 위치, 세척액 주입속도가 치근단에 작용하는 압력에 미치는 영향)

  • Lee, Chang-Ha;Jo, Seol-Ah;Lim, Bum-Soon;Lee, In-Bog
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.275-286
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of needle tip design and position, and irrigant flow rate on apical pressure (AP) during root canal irrigation. Five human mandibular premolars were instrumented up to #35 (0.06 taper) using nickel-titanium rotary instruments. Three different needles according to change of needle tip design (notched, side-vented, and flat) were positioned at the point of 1, 3, and 5 mm from the apical constriction (needle tip position). For each needle tip design and position, APs were measured with varying flow rates of 0.05, 0.1, 0.2, and 0.3 ml/s. When the other conditions were controlled, AP increased with decreasing needle tip position or increasing irrigant flow rate (p<0.05). The AP of flat needle was the highest, followed by notched, side-vented needle for the same needle tip position and irrigant flow rate. The APs at needle tip position of 1 mm or with more than 0.1 ml/s flow rate were higher than central venous pressure (5.88 mmHg) for all conditions. Flat needle was not recommended for clinical use due to sharp increase of AP with changing needle tip position and irrigant flow rate. For safe and effective root canal irrigation, irrigant should be applied with the needle tip position of 3 mm and flow rate of less than 0.05 ml/s.

Development of Verification Method for ADCP (ADCP 유량 측정기기의 검정 방안 개발)

  • Noel Kang;Chi Young Kim;Kyung Min Kang;Yo Han Cho;Chang-Hwan Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.305-305
    • /
    • 2023
  • 수문조사기기 검정은 강수량, 수위, 유량 등과 같은 수문자료를 관측하는 수문조사기기가 대상지역의 수문상황을 정확하게 관측하는지를 검사하는 일련의 과정으로 「수자원의 조사 계획 및 관리에 관한 법률」 제12조에 법적 기반을 두고 있다. 검정 대상은 강수량, 수위, 유속, 유사량, 토양수분량, 증발산량, 증발량 측정기기 총 7종이며, 환경부장관으로부터 한강홍수통제소가 검정업무를 위임받고, 한국건설기술연구원과 한국수자원조사기술원이 위탁받아 운영중에 있다. 최근에는 증발산량, 토양수분량 및 유량 측정기기기 등이 첨단화되어 기존 검정 방식에 대한보완 및 신설에 대한 요구가 증가하고 있다. 특히, 유량 측정시 기존에 사용하였던 회전식 유속계는 ADCP(Acoustic Doppler Current Profiler) 유량측정기기로 대체되어 활용률이 2013년 24%에서2021년 67%로 약 2.8배 급격히 증가하였다. 하지만 수문조사기기 검정 관련 고시 내 ADCP에 대한검사방법 및 허용오차 등의 규정이 부재하여 수문조사기기의 검정 공백이 발생하는 등의 문제가 존재하고 있다. 이에 본 연구에서는 ADCP 운영 및 기술 현황, 현행 법령, 국외 사례 등을 검토하여 ADCP 유량측정기기의 검사방법 및 허용오차에 대한 방안을 제시하고자 한다. ADCP 검사방법은 총 5단계로 외관검사, 자가진단 검사, 온도센서 검사, 수심측정 검사, 유량비교측정 검사에 따라 검정을 실시한다. 첫 번째 외관검사시에는 기기 외관과 센서 등 물리적 손상을 점검하고, 두 번째 자가진단 검사에서는 센서 변환 매트릭스 값, 수신부 센서 테스트, RAM/ROM 테스트, 통신 테스트 등에 관한 정상값 산출 여부를 확인한다. 세 번째 온도센서 검사에서는 검증용 온도센서를 이용한 값과 ADCP에 부착된 온도센서 값과 차이를 확인하고 ±2℃초과시 재검사 또는 적절한 조치를 취한 후 다음 단계의 검사를 진행한다. 네 번째 수심측정 검사에서는 수조 내 수심 측정을 확인하여 실제 수심과의 오차를 확인하고 ±1% 초과시 재검사 또는 적절한 조치 후 다음 검사를 실시한다. 유량비교 측정검사에서는 각 기기 간의 평균유량의 상대오차를 평가하는 것으로 ±5%미만에는 합격, ±5이상 ±10%미만에서는 재검사, ±10%이상에서는 공장수리를 권고하도록 하고, 1~5 단계의 검사를 통과한 기기를 대상으로 인증서를 발급하도록 한다. 유량비교 측정검사시에는 매년 ADCP를 사용하는 일반기업 및 공공기관 등이 모여 ADCP의 성능을 상호간 비교하는 'ADCP 기술협력 워크숍'을 확장하여 실시할 수 있다. 각 검사 단계의 허용오차는 USGS 또는 제조사 기준과 2022년 ADCP 기술협력 워크숍 성능검사 분석 결과를 토대로 하였다. 본 ADCP 검정 방안은 향후 ADCP 모델별로 단계별 시범 검토를 통해 세부사항에 대한 제시가 필요하며, 온도센서 검사, 수심측정 검사, 유량 비교측정검사에 대한 허용오차에 대한 타당성에대한 검증 및 검토가 이루어져야 할 것으로 사료된다.

  • PDF

The Physical and Chemical Properties of Salt Manufactured by New Process with Brine Produced in Korean Salt-farms (염전의 함수로 제조한 천일식제조소금의 물리화학적 특성)

  • Kim, Kyeong Mi;Kim, In Cheol
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1664-1672
    • /
    • 2013
  • Solar salt is manufactured naturally, and therefore, it contains insoluble substances such as sandy compounds. This study is performed in order to effectively produce clean sea salt by removing the impurities in sea salt through filtration and evaporation in a vacuum condition. Brine was concentrated and crystallized at $90^{\circ}C$ by a rotary vacuum evaporator, which was then recovered as salt crystals by filtration, and then the salt was dehydrated. Manufacturing yields were determined by the amount of water evaporation. Brine was concentrated to 40%, 50% and 60% of the initial volume of brine and manufactured salt were designated as 40S, 50S and 60S, respectively. The salt produced by this process is called ESBS (evaporated salt with brine from salt-farm). The yield of 40S, 50S and 60S were 7.22%, 10.79% and 15.06%, respectively. The NaCl concentration of 40S and 50S were 90.38% and 91.16%, respectively. From a sensory evaluation analysis, the most tasty salt was 40S and the bitter salt was 60S. The average contents of sand compound and insoluble substances in ESBS were 0.001~0.012% and 0.067~0.12%, respectively. The mineral compositions, such as Na, Mg, K, and Ca of 40S and 50S were similar with those of the natural solar salt. In solubility tests, the solubility (g of salt/100 mL $H_2O$/sec) of 40S, 50S, and 60S was 0.69, 0.70, and 0.69, respectively. On the other hand, the solubility of natural solar salt was 0.47. By comparing the water reabsorption rate analysis results, water reabsorption rate of 40S and 50S was about 3 to 5 times lower than that of the solar salt. In the aspects of physical and chemical properties, such as minerals, impurities, solubility and moisture re-absorption rate, salts developed in this study are judged to be better than that of the general solar salt.

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF