최근 부하설비의 증가와 더불어 전기화재 사고에 대비한 안전장치의 연구와 규정이 전세계적으로 변동하는 추세에 있다. 이와 관련하여 본 논문에서는 국내화재에서 전기화재가 차지하는 비율과 아크 회로차단기의 정의와 필요성에 관하여 기술하였으며, 국가별 아크 회로차단기의 국제동향을 바탕으로 국내실정에 맞도록 아크 회로차단기에 대한 규정변화를 모색하고자 한다.
Journal of the Korea Academia-Industrial cooperation Society
/
v.18
no.11
/
pp.755-761
/
2017
In railways powered by AC power, the main circuit breaker (MCB) is used for supplying the electric power to the catenary of the vehicle. Generally, the main circuit breaker is located between the pantograph and the main transformer, and the phase of the power applied to the vehicle changes according to the operation timing of the main circuit breaker. The operation of the main circuit breaker should be actively controlled according to the phase of the power source, since the phase of the power causes unintended transient states in the vehicle's electrical system in the form of an inrush current and surge voltage. However, the MCB has a delay time when it operates which is not constant. Therefore, an intelligent controller is needed to predict the operation delay time and control the opening and closing of the MCB.
본 발명은 전기설비의 중요한 부분을 차지하고 있는 차단기의 동작코일 단선유무를 감지하기 위한 센서에 관한 것으로 보조계전기, 브릿지회로, 전압분배회로 및 출력회로로 구성되어 있다. 차단기동작코일에 동작코일의 저항값보다 충분히 큰 저항를 병렬로 연결하고, 이 병렬회로를 브릿지회로의 한변으로 이용하며, 전압분배회로를 설계하여 동 브릿지회로의 전원공급용으로 사용한다. 차단기동작코일이 정상상태일 경우에는 브릿지 회로의 출력단자에는 전압이 발생하지 않아 발광다이오우드(LED)가 동작하지 않고, 단선될 경우에는 브리릿지회로의 출력단자에 전압이 발생하여 발광다이오우드가 점둥되게 함으로써 차단기 운영의 신뢰성을 높일수 있는 장점이 있다.
Choi, Gyu Seok;Cha, Hyun Kyung;Sohn, Jeong Hyun;Yoo, Wan Suk
Transactions of the Korean Society of Mechanical Engineers A
/
v.38
no.1
/
pp.25-30
/
2014
The dynamic characteristics of a gas circuit breaker depend on the underlying high-speed operating mechanism with a spring-actuated latch system. Many studies have been carried out to reduce the breaking time of circuit breakers. In this study, the optimum latch contour design is determined for reducing the breaking time of a circuit breaker. A multi-body dynamic model of the latch is established for analyzing the dynamic behaviors of the circuit breaker by using the MSC/ADAMS program. Simulation results are matched against experimental data. VisualDoc is employed for determining the optimal latch contour. From the optimum design, the breaking time of a gas circuit breaker is improved by about 8.6%.
KSTAR 핵융합 장치에 초전도 코일을 사용하는 경우 코일의 저항이 제로에 가까우므로 낮은 전압으로 20kA 이상의 전류를 흘릴 수 있어 많은 전력을 필요로 하지 않는 장점이 있다 그러나 초전도 코일 내부의 한 부분에서 온도가 상승하여 저항이 증가하는 치 현상이 자주 일어날 수 있으며 이 경우 코일이 손상된다 이를 막기 위한 회로가 치 보호회로이며 대전류 차단기와 에너지를 소비시킬 저항으로 구성되어 있다 초전도 코일에 적용 되는 전원장치의 용량은 20kA에서 35kA에 이르며 치 보호를 위해 직류 대전류 차단기를 필요로 한다. 그러나 현재 상업적으로 생산되고 있는 기계적 차단기는 교류에서만 동작하며 직류 차단이 가능한 차단기들은 용량이 위의 값에 미치지 못하며 크기와 가격 및 반복성에 있어서 제약을 가지고 있다. 따라서 기계적 스위치의 장점과 반도체 싸이리스터 스위치의 장접을 결합한 직류 대전류 차단기를 개발함으로써 시스템의 크기와 가격을 낮추어 경제적으로 더 나은 효과를 가져오며 신뢰성 및 반복성을 높인 회로를 개발하여 KSTAR 토카막 초전도 코일 치 보호시스템에 적용하고자 한다.일 치 보호시스템에 적용하고자 한다.하고자 한다.
Cha, Hyun Kyung;Jang, Jin Seok;Yoo, Wan Suk;Sohn, Jeong Hyun
Transactions of the Korean Society of Mechanical Engineers A
/
v.38
no.11
/
pp.1215-1220
/
2014
Breaking time is an important performance indicator of a circuit breaker. Thus, the operating mechanism of the circuit breaker should be optimized for reducing the breaking time. The operating mechanism in a gas circuit breaker is made up of several latches. Specifically, the geometry and relative positions of latches influence the dynamic behaviors of the operating mechanism. In this study, a three-stage latch operating mechanism is analyzed on the basis of the verified multibody dynamics model constructed using the MSC.ADAMS program. The relative positions and lengths of latches are selected as design variables. The dominant design variables are selected by a design study. Optimization is performed using a genetic algorithm (GA). The study results demonstrate that the performance of the circuit breaker improves by about 22.5.
The Journal of the Korea institute of electronic communication sciences
/
v.15
no.6
/
pp.1069-1074
/
2020
Since DC has no zero point, an arc occurs when the DC circuit breaker performs a shutdown operation. In this case, a fatal accident may occur in the circuit breaker or in the grid, depending on the magnitude of the arc. Therefore, the shutdown performance and the reliability of the circuit breaker are important in the commercialization of HVDC. In this study, a superconducting LC circuit breaker was proposed to improve the performance and the reliability of the DC circuit breaker. The superconducting LC circuit breaker applied a superconducting coil to the inductor of the existing LC circuit breaker. Other than limiting the initial fault current, it also creates a stable zero point in the event of a fault current. To verify this, simulation was performed through EMTDC/PSCAD. Furthermore, the superconducting LC circuit breaker was compared with the LC circuit breaker with a normal coil. As a result, it was found that the LC circuit breaker with the superconducting coil limited the initial fault current further by approximately 12 kA compared to the LC circuit breaker with a normal coil. This reduced the arc extinguish time by approximately 0.16 sec, thereby decreasing the elctrical power burden on the circuit breaker.
Proceedings of the Korean Society of Precision Engineering Conference
/
2002.05a
/
pp.735-739
/
2002
PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.
Transactions of the Korean Society of Mechanical Engineers A
/
v.35
no.7
/
pp.723-728
/
2011
Since the performance of a vacuum circuit breaker (VCB) mainly depends on the spring operating mechanism, an analysis of the spring operating mechanism is required in order to improve the design of a VCB. In this study, the static stiffness of the spring was determined by using a material testing machine, and the test results were used to model the spring through computer simulation. The multi-body dynamic model of the spring was established by using the RecurDyn program. The dynamic model was verified by comparing the results of stem displacements and rotating angles of the brake shaft obtained from the simulation and from the experiments. After verification of the dynamic model of VCB, the cam profile of the VCB was optimized through multi-body dynamics simulation in order to improve the performance of the closing mechanism.
우리나라의 배전선로는 가공선로 위주로 성장하여 약40여년전부터 지중배전선로를 보급하기 시작하여 현재는 전제선로의 12.1%를 지중화하기에 이르렀다. 지중설비의 증가는 배전선로 안정화에 상당한 기여를 하였으며 일시 및 순간고장도 과거에 비해 엄창나게 줄어들게 되었으며, 이로 인하여 고장에 있어서 세계적인 수준의 전기품질을 자랑할수 있게 되었다. 하지만, 지중배전선로는 일반적으로 고장전류가 매우크고, 일단 고장이 발생하면 복구에 장시간이 소요될 뿐 아니라 고장원인을 찾는데도 상당한 어려움이 있으며, 최근에는 지상기기(변압기, 개폐기)등이 노후화 되면서 안전사고로 까지 확대되고 있는 상황이다. 때문에 지중배전선로에 적용할수 있는 다회로차단기를 개발하여 고장예방 및 고장구간 축소에 사용하고 있지만, 아직까지 보호협조 측면으로 잘 활용되고 있지 않고 있다. 따라서 본 논문에서는 현행 한전의 지중배전선로 보호기기운영 상황을 분석하고 지중 배전선로에 운전되고 있는 다회로차단기의 적합한 운영방법을 제시하여 지중배선선로 보호협조 방안을 강구하여 보고자 한다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.