• Title/Summary/Keyword: 활성탄 흡착탑

Search Result 50, Processing Time 0.029 seconds

Adsorption Analysis of VOCs of Zeolite Synthesized by Coal Fly Ash in a Fixed-bed Adsorber (고정층 흡착탑에서 석탄비산재로부터 합성한 Zeolite의 VOCs 흡착 해석)

  • Kim, Seong-Soo;Lee, Chang-Han;Park, Sang-Wook
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.784-790
    • /
    • 2010
  • VOCs such as acetone, benzene, toluene, ethylbenzene were adsorbed in a fixed-bed adsorber using zeolite synthesized from coal fly ash and 4 kinds of activated carbon at 101.3 kPa. The adsorber was operated batchwise with the charge of 5 g adsorbent to obtain the breakthrough curve of VOCs. Experiments were carried out at $40^{\circ}C$, nitrogen flow rate of $70cm^3/min$ and sparger temperature of $30^{\circ}C$. The deactivation model was tested for these curves by combining the adsorption of VOCs and the deactivation of adsorbent particles. The observed values of the adsorption rate constant and the deactivation rate constant were evaluated through analysis of the experimental breakthrough data using a nonlinear least square technique. The experimental breakthrough data were fitted very well to the deactivation model than the adsorption isotherm models in the literature. Also, adsorption capacities of adsorbents were obtained from the breakthrough curve to observe the correlation between adsorption capacity and the physical properties of VOCs.

Simultaneous Adsorption Characteristics of Binary-Component Volatile Organic Compounds (2성분계 휘발성유기화합물의 동시 흡착특성)

  • Park, Byung-Bae;Kim, Han-Su;Park, Yeong-Seong
    • Clean Technology
    • /
    • v.7 no.2
    • /
    • pp.133-140
    • /
    • 2001
  • The adsorption characteristics of binary-component Volatile Organic Compounds(VOCs) with benzene and toluene were studied in a fixed bed backed with activated carbon. The adsorption intensites of benzene and toluene resulted from equilibrium adsorption capacity led to roll up phenomenon in a fixed bed and behaved benzene as non-key component which meant the smaller affinity to the activated carbon of the two. From comparion with breakthrough curves between binary-component and single component systems at the same concentration conditions, the stoichiomertic breakthrough time of toluene in both systems had no difference, but that of benzene as non-key component had a tendency to shorten 130min than 200min of single component. In the breakthrough characteristics of binary-component adsorbates, the magnitude of roll-up of the non-key component increased with the increasing of non-key component ratio and aspect ratio(L/D) of fixed bed, while decreased with the increasing of interstitial velocity. Especially, the roll-up phenomenon was more conspicuous with the increasing of mole fraction of key component.

  • PDF

A Study on Economics of Air Stripping Towers and Activated Carbon Adsorption(Multicomponent System) (충전탑 공기 스트리핑과 활성탄 흡착의 경제성에 관한 연구(다중성분계))

  • Yoo, Ho Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.33-42
    • /
    • 1998
  • The optimum design and preliminary cost estimations of air stripping towers ASTs with granular activated carbon adsorption (GAC) systems as the off-gas treatment were done and compared to liquid-phase GAC system. The optimum design and preliminary cost estimations were done for either single or multicomponent systems. A computer program was developed for this study. 15 single compounds and their multicomponent systems were studies. Even with off-gas treatment, AST was generally a less expensive process for treatment of volatile organics than liquid-phase GAC system. Treatment costs of small systems were sensitive to system capacity. Accumulative effect of treatment costs was found in multicomponent systems. The cost of a multicomponent system was highly dependent on the least strippable component in ASTs even with gas-phase GAC or the least adsorbable component in liquid-phase GAC system.

  • PDF

Adsorption Characteristics of VOCs in Activated Carbon Beds (활성탄 흡착탑을 이용한 휘발성 유기화합물의 흡착특성)

  • Noh, Soon-Young;Kim, Ki-Ho;Choi, Jae-Ho;Han, Sam-Duck;Kil, In-Sub;Kim, Duk-Hyun;Rhee, Young-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.4
    • /
    • pp.455-469
    • /
    • 2008
  • VOCs (Volatile organic compounds) are known as one of the harmful chemicals, causing cancer and global warming. Therefore, the proper control, removal, and reduction of the emission of VOCs are important tasks for the environmental protection. Among the method of VOCs removal activated carbon bed is the most efficient and economical method. In this study, the adsorption performance of toluene gas was investigated using various activated carbons. To find out the adsorption efficiency, the H/D (Height/Diameter) of the activated carbon and GHSV (Gas Hourly Space Velocity) of the toluene gas were manipulated with various conditions. The effect of the temperature, humidity and toluene-MEK-IPA mixed gas on adsorption were also investigated. As a result, a high adsorption performance was found when GHSV is lower at room temperature and low humidity. It was also found that the adsorption efficiency of toluene-MEK-IPA mixed gas system was lower than that of toluene gas system.

Investigation on Desorption Characteristics of VOCs Adsorbed on used Activated Carbons Collected from Painting Process (도장공정에서 수거한 폐활성탄에 흡착된 VOCs의 탈착특성 연구)

  • Kim, Joo Yeon;Yoon, Sung Min;Park, Kunyik;Yoon, Soo Kyung;Kil, In Sub;Park, Hui Jae;Rhee, Young-woo
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.752-756
    • /
    • 2010
  • Desorption reaction characteristics of the used activated carbons collected from painting process in Shiwha/Banwal industrial complex were investigated. Thermogravimetric analyzer was used to investigate the desorption characteristics. Activation energies and reaction orders for desorption reaction characteristics of used activated carbons were estimated by employing Friedman method and Freeman-Carroll method. In the used activated carbons collected from painting process, it was found that the activation energies were 20.6~43.2 kJ/mol in Friedman method and 12.3~26.5 kJ/mol in Freeman-carroll method, and reaction orders were 0.1~1.7.

Analysis of cause of engine failure during power generation using biogas in sewage treatment plant (하수처리장 바이오가스를 이용한 발전시 가스엔진의 고장원인 분석)

  • Kim, Gill Jung;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.13-29
    • /
    • 2016
  • In this study, we analyzed the causes of major faults in the biogas plant through the case of gas engine failure when cogenerating electricity and heat using biogas as a fuel in the actual sewage treatment plant and suggested countermeasures. Hydrogen sulfide in the biogas entering the biogas engine and water caused by intermittent malfunction of the water removal system caused intercooler corrosion in the biogas engine. In addition, the siloxane in the biogas forms a silicate compound with silicon dioxide, which causes scratches and wear of the piston surface and the inner wall of the cylinder liner. The substances attached to the combustion chamber and the exhaust system were analyzed to be combined with hydrogen sulfide and other impurities. It is believed that hydrogen sulfide was supplied to the desulfurization plant for a long period of time because of the high content of hydrogen sulfide (more than 50ppm) in the biogas and the hydrogen sulfide was introduced into the engine due to the decrease of the removal efficiency due to the breakthrough point of the activated carbon in the desulfurization plant. In addition, the hydrogen sulfide degrades the function of the activated carbon for siloxane removal of the adsorption column, which is considered to be caused by the introduction of unremoved siloxane waste into the engine, resulting in various types of engine failure. Therefore, hydrogen sulfide, siloxane, and water can be regarded as the main causes of the failure of the biogas engine. Among them, hydrogen sulfide reacts with other materials causing failure and can be regarded as a substance having a great influence on the pretreatment process. As a result, optimization of $H_2S$ removal method seems to be an essential measure for stable operation of the biogas engine.

Experiment and Simulation of 2-bed PSA for Hydrogen Separation from H2/CH4 Gas Mixture (수소/메탄 혼합 기체로부터 수소 분리를 위한 두 탑 PSA 실험과 전산 모사)

  • Nam, Gi-Moon;Jeong, Byung-Man;Kang, Seok-Hyun;Lee, Chang-Ha;Lee, Byung-Kwon;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.249-258
    • /
    • 2005
  • A two-column six-step pressure swing adsorption(PSA) process was to study separation of hydrogen from hydrogen and methane($60_{vol}%/40_{vol}%$) binary system onto activated carbon adsorbent. The effects of the feed gas pressure, the feed flowrate and the P/F(purge to feed) ratio on the process performance were evaluated. The cyclic steady-states of PSA process were reached to after 15 cycles. $H_2$ purity increases according as the P/F ratio and pressure increase and the feed flow rate decreases; however, $H_2$ recovery shows an opposite phenomena to the purity. PSA process simulation studied to find optimum operation condition. In the results, 22 LPM feed flowrate, 11 atm adsorption pressure and 0.10 P/F ratio might be optimal values to obtain more than 75% recovery and 99% purity hydrogen. In this study was non-isothermal and non-adiabatic model considering linear driving force(LDF) model and Langmuir-Freundlich adsorption isotherm considered to compare between prediction and experimental data.

Study on Desorption Reaction of VOC Produced from Manufacturing of Chemical Products (화학제품 제조업에서 발생한 VOC의 탈착반응 연구)

  • Park, Kuny-Ik;Yoon, Sung-Min;Kim, Joo-Yeon;Kil, In-Sub;Park, Hi-Jae;Rhee, Young-Woo
    • Applied Chemistry for Engineering
    • /
    • v.21 no.5
    • /
    • pp.505-508
    • /
    • 2010
  • The characteristics of desorption reaction for spent activated carbon produced from the manufacture of other chemical products in Shiwha/Banwal industrial complex were investigated. TGA (Thermogravimetric Analyzer) was used to study for characteristics of desorption and kinetics. Then Friedman method and Freeman-carroll method were used to find the activation energy and the order of reaction. Activation energy by Friedman method was 24.82~46.49 kJ/moL. And then activation energy and order of reaction by Freeman-carroll method were 8.77~32.26 kJ/moL and 0.11~1.69.

Hydrogen Separation from Binary and Ternary Mixture Gases by Pressure Swing Adsorption (PSA 공정에 의한 이성분 및 삼성분 혼합기체로부터 수소분리)

  • Kang, Seok-Hyun;Jeong, Byung-Man;Choi, Hyun-Woo;Ahn, Eui-Sub;Jang, Seong-Cheol;Kim, Sung-Hyun;Lee, Byung-Kwon;Choi, Dae-Ki
    • Korean Chemical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.728-739
    • /
    • 2005
  • An experiment and simulation were performed for hydrogen separation of mixtures by PSA (pressure swing adsorption) process on activated carbon. The binary ($H_2/Ar$; 80%/ 20%) and ternary ($H_2/Ar/CH_4$; 60%/ 20%/ 20%) mixtures were used to study the effects of feed composition. The cyclic performances such as purity, recovery, and productivity of 2bed-6step PSA process were experimentally and theoretically compared under non-isothermal and non-adiabatic conditions. The develped process produced the hydrogen with 99% purity and 75% recovery from both processes. Therefore, optimal separation condition was referred multicomponent gas mixtures.

Practical Usage of Low-Temperature Metal Catalyst for the Destruction of Volatile Organic Compounds (VOCs) (휘발성 유기화합물(VOCs) 제거를 위한 저온금속촉매 실용화에 관한 연구)

  • Jung, Sung-Chul;Lee, Seung-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.397-405
    • /
    • 2012
  • In this study, performance evaluation of newly developed technology for the economical and safe removal of volatile organic compounds (VOCs) coming out from electronic devices washing operation and offensive odor induction materials was made. Metal oxidization catalyst has shown 50% of removal efficiency at the temperature of $220^{\circ}C$. Composite metal oxidization catalyst applied in this study has shown that the actual catalysis has started at the temperature of $100^{\circ}C$. Comprehensive analysis on the catalyst property using Mn-Cu metal oxidization catalyst in the pilot-scale unit was made and the removal efficiency was variable with temperature and space velocity. Full-scale unit developed based on the pilot-scale unit operation has shown 95% of removal efficiency at the temperature of $160^{\circ}C$. Optimum elimination effective rates for the space velocity was found to be $6,000hr^{-1}$. The most appropriate processing treatment range for the inflow concentration of VOCs was between 200 ppm to 4,000 ppm. Catalyst control temperature showed high destruction efficiency at $150{\sim}200^{\circ}C$ degrees Celsius in 90~99%. External heat source was not necessary due to the self-heat reaction incase of VOCs inflow concentration is more than 1,000 ppm. Equipment and fuel costs compared to the conventional RTO/RCO method can be reduced by 50% and 75% respectively. And it was checked when there was poisoning for sulfide and acid gas.