• Title/Summary/Keyword: 환자 자세

Search Result 643, Processing Time 0.024 seconds

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

A Study of Image Quality and Exposed Dose by Field Size Changing on CBCT (CBCT 촬영 시 조사야 조절에 따른 영상의 최적화 및 피폭선량에 관한 고찰)

  • Bang, Seung Jae;Kim, Young Yeon;Jeong, Il Seon;Kim, Jeong Soo;Kim, Young Gon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.175-180
    • /
    • 2013
  • Purpose: Modern radiation therapy technique such as IGRT has become a routine clinical practice on LINAC for decrease patient's set-up error. CBCT can be used to adjust patient set-up error and treat patient more accurately. The Purpose of this study is to evaluate field size of CBCT for improving Image quality and suggest reference date of CBCT field size. Materials and Methods: Image date were acquired using KV CBCT and Catphan phantom (Half fan and full fan mode were scanned from 2 ~16 cm, at intervals of 2 cm). Field size were categorized by Small field size (2 cm, 4 cm), Medium field size (8 cm, 10 cm), Large field size (more than 14 cm) and evaluate. To estimated the CTDi using CTDi phantom and Ion chamber. Results: CT number linearity of Small and Large field size are greater than Medium field size. Spatial resolution are not significantly different without Small field size. But half fan mode is more different than full fan mode. In full fan, except Medium field size, all field size exceed recommendation for HU uniformity. But half pan has stability for all field except Small field size. CTDi makes radical sign function graph in Medium field size. Conclusion: The worst result was given by Small field size for Image quality and practically. Medium field size can be useful to prevent patient from radiation exposure and give better Image quality. So this study recommends that Medium field size (8~10 cm) is more suitable for CBCT.

  • PDF

A Study of the Real Conditions of the Management of Dental Hygienists' Self-Oral Health (치과위생사의 자기구강건강관리에 관한 연구)

  • Lee, Kyung-Ae
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.45-49
    • /
    • 2005
  • This study is designed to present basic materials necessary for offering the more effective way of dental hygienists, or those who are in charge of the education of Oral health, the treatment and prevention of dental problems, educating Oral health by stage by dint of determining the actual condition of the knowledge and management of dental hygiene, or prevention of the basic dental disease except the professional methods of dental management and evaluating their abilities to manage dental hygienes. In terms of the real conditions of the management of dental hygienes, the majority of the subjects said, "not bad" or "healthy". Most of them (62.1%) said that they brush their teeth three times a day, and most of them (85.2%) depend on rolling methods. 69.2% of them used brushes that are neither hard nor soft, and 28.4% of them use soft brushes and 49.7% of them brush their teeth for about 3 minutes. In terms of brushing time, 27.8% of them brush their teeth after lunch, while 23.8% of them brush their teeth after breakfast. 66.3% of them use fluoric tooth pastes while 19.5 percent of them said, "I have no idea." and 14.2% of them said, "No." In terms of complementary dental hygiene goods, dental goggles are used by 23% of them, and dental threads are used by 78.1% and tooth brushes are used by 78.1% of them, and 42.4% of the subjects use the instruments one to twice a day, and 53.8% of them use them for less than one minute a time. In terms of dental health care, 17.2% of them have a chew of gum and 8.3% of them pay a regular visit to dental clinics and 5.3% of them don't smoke.

  • PDF

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

Feasibility Study of Isodose Structure Based Field-in-Field Technique for Total Body Irradiation (전신조사방사선치료 시 Isodose Structure를 이용한 Field-in-Field Technique의 유용성 평가)

  • Lee, Yoon Hee;Ban, Tae Joon;Lee, Woo Seok;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: In Asan Medical Center, Two parallel opposite beams are employed for total body irradiation. Patients are required to be in supine position where two arms are attached to mid axillary line. Normally, physical compensators are required to compensate the large dose difference for different parts of body due to the different thicknesses compared to the umbilicus separation. There was the maximum dose difference up to 30% in lung and chest wall compared to the prescription dose. In order to resolve the dose discrepancy occurring on different body regions, the feasibility of using Fieid-in-Field Technique is investigated in this study. Materials and Methods: CT scan was performed to The RANDO Phantom with fabricated two arms and sent to Eclipse treatment planning system (version 10.0, Varian, USA). Conventional plan with physical lead compensator and new plan using Field-in-Field Technique were established on TPS. AAA (Anisotropic Analytical Algorithm) dose calculation algorithm was employed for two parallel opposite beams attenuation. Results: The dose difference between two methods was compared with the prescription dose. The dose distribution of chest and anterior chest wall uncovered by patient arms was 114~124% for physical lead compensator while Field-in-Field Technique gave 106~107% of the dose distribution. In-vivo dosimetry result using TLD showed that the dose distribution to the same region was 110~117% for conventional physical compensator and 104~107% for Field-in-Field Technique. Conclusion: In this study, the feasibility of using FIF technique has been investigated with fabricated arms attached Rando phantom. The dose difference was up to 17% due to the attached arms. It is shown that the dose homogeneity is within ${\pm}10%$ with the CT based 3-dimensional 4 step FIF technique. The in-vivo dosimetry result using TLD was showed that 95~107% dose distribution compared to prescription dose. It is considered that CT based 3-dimensional Field-in-Field Technique for the total body irradiation gives much homogeneous dose distribution for different body parts than the conventional physical compensator method and might be useful to evaluate the dose on each part of patient body.

  • PDF

Clinical features of children's brain tumors according to location (소아 뇌종양 발생위치에 따른 임상양상 고찰)

  • Han, Seung Jeong;Kim, Yun Hee;Kwon, Young Se;Jun, Yong Hoon;Kim, Soon Ki;Son, Byong Kwan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.1
    • /
    • pp.76-81
    • /
    • 2006
  • Purpose : This study evaluated the clinical characteristics of brain tumors in children according to their location, the parental delay and the doctor's delay between the onset of symptoms and the diagnosis of a pediatric brain tumor. In addition, this study compared the relationship between the pre-diagnostic symptomatic interval and the tumor location. Methods : A retrospective study was undertaken of 45 children with primary brain tumors admitted to Inha Hospital from July, 1986 to June, 2004. A diagnosis of the tumor location was made using brain MRI. Results : The male to female ratio was 1 : 0.67. The median age at diagnosis was 6.0 years in supratentorial tumors, 7.0 years in infratentorial tumors. Twenty four cases(53.3 percent) were located in the supratentorial area, 21 cases(46.6 percent) were located in the infratentorial area. The distribution of supratentorial tumors were 14(58.3 percent) in the cerebral hemisphere and temporal lobe, seven (29.1 percent) in the suprasellar area, and three(12.5 percent) in the pineal gland and posterial lateral ventricle. The distributions of the infratentorial tumors were 12(57.1 percent) in the cerebellar vermis and fourth ventricle, four(19.1 percent) in the brain stem, and five(23.8 percent) in the cerebellar hemisphere. The most common initial symptom was seizure(37.5 percent) in the supratentorial tumor and headache(38.0 percent) in infratentorial tumors. The median pre-diagnostic symptomatic interval (PSI) was 21 days(range 0-240 days). The median PSI with a parental delay in supratentorial tumor was six days(range 1-240 days), and 30 days(range 1-40 days) in the infratentorial tumor. We immediately diagnosed most cases after visiting the hospital. There was no significant relationship between the tumor location and the pre-diagnostic symptomatic interval. Conclusion : The most common symptom of supratentorial tumors and infratentorial tumors was seizure and headache, respectively. Although, the median pre-diagnostic symptomatic interval was shorter than in previous studies, a detailed medical history and a correctly interpreted neurological examination should lead to an earlier diagnosis of pediatric brain tumors.

Evaluation of the Minimum Shear Reinforcement Ratio of Reinforced Concrete Members (철근콘크리트 부재의 최소전단보강근비의 평가)

  • Lee Jung-Yoon;Yoon Sung-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.43-53
    • /
    • 2004
  • The current Korean Concrete Design Code(KCI Code) requires the minimum and maximum content of shear s in order to prevent brittle and noneconomic design. However, the required content of the steel reinforcement In KCI Code is quite different to those of the other design codes such as fib-code, Canadian Code, and Japanese Code. Furthermore, since the evaluation equations of the minimum and maximum shear reinforcement for the current KCI Code were based on the experimental results, the equations can not be used for the RC members beyond the experimental application limits. The concrete tensile strength, shear stress, crack inclination, strain perpendicular to the crack, and shear span ratio are strongly related to the lower and upper limits of shear reinforcement. In this research, an evaluation equation for the minimum content of shear reinforcement is theoretical proposed from the Wavier's three principals of the mechanics of materials.

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF

Effects Of Environmental Factors And Individual Traits On Work Stress And Ethical Decision Making (간호사의 환경적 요소와 개인적 특성이 직무스트레스와 윤리적 의사결정에 미치는 영향)

  • Kim, Sang Mi L.;Shake ketefian
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.3
    • /
    • pp.417-430
    • /
    • 1993
  • 이 연구는 환경적 요소(간호사의 자율성, 조직의 표준화)와 개인의 특성(통제위, 나이, 경험. 간호역할개념, 도덕성), 직무 스트레스, 윤리적 의사결정 사이의 관계를 이론적 틀을 구성하여 테스트함으로써 그 인과관계를 탐구하였다. 본 연구를 위해 개발된 모형은 1) Katz와 Kahn의 조직에 대한 개방체계 이론(open systems theory of organization) ; 2) Kahn. Wolfe, Quinn, Snoek의 스트레스 이론 (theory of stress) : 3) Kohlberg의 도덕발달 이론(theory of moral develop-ment): 그리고 4) 여러 문헌고찰을 기초로 하였다. 본 연구의 모형은 2가지의 주요 종속변수(직무 스트레스, 윤리적 간호행위), 2가지 매개변수(간호 역할개념, 도덕성 발달정도) 그리고 여러 독립변수들(조직의 표준화, 자율성, 통제위, 교육, 나이, 경험 등)로 구성되었다. 간단히 말해, 간호사의 스트레스와 윤리적 간호행위 를 개인 자신과 환경이라는 두 요소의 결과로 간주한 것이다. 미국(2개주)의 여러 건강관리기관에 근무하는 224명의 정규 간호사를 대상으로 하였고. 가설 검증을 위하여 1) 변수간의 인과관계를 조사하기 위한 Linear Structural Relationships(LISREL)기법과 2) 나이, 경험, 교육이 변수간의 관계에 미치는 중간역할을 알아보기 위해 상관분석을 이용하였다. LISREL결과를 보면 제시된 모델이 각 내재 변수에 상당한 설명력을 가지면서 자료에 잘 맞는 것으로 나타났다. 이 연구에서 가장 뚜렷한 점으로 나타난 것은 개인의 특성보다 환경적 요소로서의 자율성이 직무스트레스와 윤리적 의사결정을 예견하는데 훨씬 중요한 변수로 부각되었다는 점이다. 또한 간호사의 전문적 역할개념과 봉사적 역할개념이 간호사의 윤리적 의사결정을 예견하는 가장 중요한 요소로 나타났다. 중간영향(moderation effect)을 보면, 젊고 경험이 적은 간호사일수록 나이가 많고 경험있는 간호사보다 환경적 요소(자율성)에 더 큰 영향을 받는다는 것을 암시하고 있다. 또한 4년제 대학 이상을 졸업한 간호사의 윤리 적 간호행 위 는 2, 3년제 를 졸업 한 간호사 보다 환경적 요소에 의해 덜 영향을 받는 것으로 나타났다. 한편 자율성의 부족은 2, 3년제 졸업 간호사보다 4년제 졸업 간호사에게 더 심한 스트레스가 되고 있음을 시사하였다. 이 연구의 결과로부터 적어도 다음과 같은 두 가지 실제적인 제언을 도출할 수 있다. 첫째, 이 연구는 환경적요소로서의 자율성이 다른 어떤 개인적인 요소보다 직무 스트레스를 예견하는 데 중요한 요소라는 것을 제시하였다. 이것은 간호행정가들에게, 간호사의 직무 스트레스를 감소시키기 위해선 “자율성”이 아주 중요히 다루어져야 한다는 것을 의미한다. 만일 간호사들의 직무스트레스가 그 개인의 복지에 큰 해가 되고 환자를 간호하는 데 직접적으로 관계된다면, 간호행정가는 그 조직의 직무체계를 다시 평가해서 일에 대한 새로운 설계가 필요한지를 파악해야 한다. 또한 이 연구는 직무를 다시 설계할 경우, 누구에게 먼저 촛점을 두고 시작해야 하는지를 밝혀주고 있다. 즉, 젊고 경험이 미숙한 간호사들에게 촛점을 두고 시작해야 하며, 작업환경의 가장 중요한 차원중의 하나인 사회적 지원(social support)을 조심스럽게 고려해 보아야 한다. 둘째, 간호사의 윤리적 간호행위를 높히기 위해 전문적 역할개념과 봉사적 역할개념이 재강조될 필요가 있다. 이 두 역할개념 들을 교육을 통하여 효과적으로 가르칠 필요가 있다고 본다. 이 두 개념들이 간호사의 바람직한 간호행 위에 영향을 미치는 가장 중요한 요소로 나타났기 때문이다. 또한, 본 연구결과에 따르면, 경험이 많을수록 일에 싫증을 느껴 바람직한 윤리적 간호행위가 감소되는 경향이 있었다. 따라서, 건강관리체제 (health care system) 안에서의 간호사의 역할이-전문직으로서의, 그리고 환자를 위한 옹호자로서의-학교와 임상에서 효과적으로 교육되어져야 한다고 본다. 간호사들의 역할에 대한 계속적인 교육이 학생은 물론 임상 간호사들에게도 실시되어져야 할 것이다. 미래연구의 방향을 제시해 보면 첫째로 연구의 일반화를 높히기 위해 더 많은 대상자를 포함시켜야 한다. 이는 여러 종류의 표본을 반드시 한번에 전부 포함시켜야 한다는 것을 의미하는 것이 아니고, 특정한 여러 표본들을 연속적으로 연구함으로서 이 목표를 성취할 수 있다고 생각한다. 둘째는 여러 construct들(윤리적 간호행위, 직무 스트레스, 간호 역할개념 등)에 대한 적절한 측정도구를 개발해야 한다. 측정도구를 개발하기 위해서는 풍부하고 세세한 통찰력을 제공하는 질적인 정보를 얻는 것이 선행되어야 한다. 셋째, 윤리적 간호행위와 직무 스트레스에 관한 연구를 증진시키기 위해 실험설계 및 종단적 연구(expel-imental, longitudinal design)가 시도될 필요가 있다. 마지막으로, 윤리적 간호행위와 직무 스트레스를 예견할 수 있는 이론적 탐구(theoretical exploration), 즉 이론정립을 위하여, 환경적 요소와 개인의 특성에 대한 자세한 정보를 제공해 줄 수 있는 질적 연구들이 요구된다.

  • PDF

Investigation on the Perception of Mandatory Clinical Practice in the Department of Radiology Following the Amendment of the Medical Technologists Act (의료기사 등에 관한 법률 개정으로 방사선(학)과 현장실습 의무화에 따른 인식 조사)

  • Jeong-Mu Lee;Yong-Ki Lee;Sung-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.293-300
    • /
    • 2024
  • On October 31, 2023, the revision of the Medical Technologist Act made it mandatory to complete field training courses in order to obtain a license as a radiologic technologist. Therefore, we would like to survey the actual situation of field training in medical institutions to inform the revised Medical Technologist Act and propose improvement measures to increase the effectiveness of field training. A survey was conducted from March to April, 2023, among radiologic technologists working in medical institutions. The questionnaire was sent through a form on a domestic portal site, Company N, and 120 respondents completed it. Eighty-two respondents, or 68.3 percent, had experience in educating on-the-job training students. 58% of the respondents were aware of the fact that the amendment to the Act on Medical Technologist etc. made field training mandatory to obtain a radiologic technologist license. In accordance with Article 9 of the Medical Technologist Act, which prohibits unlicensed persons from practicing, 50% of the respondents were aware that those who are in training to complete an education course equivalent to the license they are seeking to obtain at a university or other institution are allowed to practice as medical Technologists. When asked what is currently taught during fieldwork, 6% of respondents said that they are required to perform radiation-generating activities in addition to observing, guiding patients, and positioning and moving patients. When asked about the future direction of education as fieldwork becomes mandatory for licensure, 77% of respondents said that they will teach more than they currently do. When asked about the appropriate total length of fieldwork, 35% said 12 weeks and 480 hours, 33% said 8 weeks and 320 hours, and 27% said 16 weeks and 640 hours. It can be seen that the current on-the-job training is inadequate according to various regulations, and students' satisfaction is low. However, with the revision of the Act on Medical Technologists, field training has become mandatory to obtain a license as a radiologist, and it is necessary to improve the educational conditions of field training. Therefore, it is necessary to comply with the Nuclear Safety Act and the Rules on the Safety Management of Diagnostic Radiation Generating Devices, introduce standardized training objectives and evaluation systems, designate training hospitals and radiologists in charge of training, and introduce extended training periods and simulation exercises to internalize field training.