• Title/Summary/Keyword: 환자 안전

Search Result 1,556, Processing Time 0.033 seconds

Evaluation and Verification of the Attenuation Rate of Lead Sheets by Tube Voltage for Reference to Radiation Shielding Facilities (방사선 방어시설 구축 시 활용 가능한 관전압별 납 시트 차폐율 성능평가 및 실측 검증)

  • Ki-Yoon Lee;Kyung-Hwan Jung;Dong-Hee Han;Jang-Oh Kim;Man-Seok Han;Jong-Won Gil;Cheol-Ha Baek
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.489-495
    • /
    • 2023
  • Radiation shielding facilities are constructed in locations where diagnostic radiation generators are installed, with the aim of preventing exposure for patients and radiation workers. The purpose of this study is seek to compare and validate the trend of attenuation thickness of lead, the primary material in these radiation shielding facilities, at different maximum tube voltages by Monte Carlo simulations and measurement. We employed the Monte Carlo N-Particle 6 simulation code. Within this simulation, we set a lead shielding arrangement, where the distance between the source and the lead sheet was set at 100 cm and the field of view was set at 10 × 10 cm2. Additionally, we varied the tube voltages to encompass 80, 100, 120, and 140 kVp. We calculated energy spectra for each respective tube voltage and applied them in the simulations. Lead thicknesses corresponding to attenuation rates of 50, 70, 90, and 95% were determined for tube voltages of 80, 100, 120, and 140 kVp. For 80 kVp, the calculated thicknesses for these attenuation rates were 0.03, 0.08, 0.21, and 0.33 mm, respectively. For 100 kVp, the values were 0.05, 0.12, 0.30, and 0.50 mm. Similarly, for 120 kVp, they were 0.06, 0.14, 0.38, and 0.56 mm. Lastly, at 140 kVp, the corresponding thicknesses were 0.08, 0.16, 0.42, and 0.61 mm. Measurements were conducted to validate the calculated lead thicknesses. The radiation generator employed was the GE Healthcare Discovery XR 656, and the dosimeter used was the IBA MagicMax. The experimental results showed that at 80 kVp, the attenuation rates for different thicknesses were 43.56, 70.33, 89.85, and 93.05%, respectively. Similarly, at 100 kVp, the rates were 52.49, 72.26, 86.31, and 92.17%. For 120 kVp, the attenuation rates were 48.26, 71.18, 87.30, and 91.56%. Lastly, at 140 kVp, they were measured 50.45, 68.75, 89.95, and 91.65%. Upon comparing the simulation and experimental results, it was confirmed that the differences between the two values were within an average of approximately 3%. These research findings serve to validate the reliability of Monte Carlo simulations and could be employed as fundamental data for future radiation shielding facility construction.

Comparison of the Clinical Outcomes of a Single Injection Adductor Canal Block with the Concomitant Use of Transdermal Buprenorphine and Continuous Adductor Canal Block after Total Knee Arthroplasty (슬관절 인공관절 전치환술 후 일회 주사 내전근관 차단술 및 경피성 Buprenorphine 병합 요법과 도관 삽입 지속적 내전근관 차단술의 임상결과 비교)

  • Huh, Jung-Wook;Park, Man-Jun;Ko, Young-Chul;Ha, Dong-Jun;Park, Joon-Hyung;Lee, Woo-Myung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.411-417
    • /
    • 2019
  • Purpose: To compare the clinical outcomes of single injection adductor canal block (SACB), continuous adductor canal block (CACB), and the concomitant use of transdermal buprenorphine after total knee arthroplasty (TKA). Materials and Methods: A total of 125 patients who underwent TKA were divided into three groups and the clinical results were retrospecitively compared. Group I was comprised of patients with pain controlled by SACB (n=41). Group II consisted of patients with pain controlled by both SACB and transdermal buprenorphine (10 ㎍/h) (n=44). Group III contained patients with pain controlled by CACB (n=40). The visual analogue scale (VAS) was used as the pain control indicator and the patients were measured on a VAS for resting on the bed (VAS-Rest) at 12 hours, 24 hours, and 48 hours after surgery. The VAS while doing continuous passive motion (VAS-CPM) on the first and second postoperative day was also measured. In addition, the total amount of medications used (Butopahn, Tridol, and Ketorac) for the intravenous patient controlled analgesia (PCA) was counted for 48 hours after surgery. As the indicator of the functional recovery outcome, the incidence of nausea and vomiting was observed for 48 hours after surgery. The maximum knee joint flexion range and maximum walking distance on the first and second postoperative day, and the total length of stay at the hospital were compared. Results: The VAS-Rest was similar in the three groups at 12 hours after surgery, but at 24 hours and 48 hours after surgery, group II and III a lower VAS-CPM and total amount of medications used for PCA than group I (p<0.05). The three groups showed a low incidence of nausea and vomiting, maximum knee joint flexion range, and similar walking distance and total length of stay at the hospital. Conclusion: The combination of SACB and transdermal buprenorphine has great pain control effect initially. On the other hand, it is not associated with catheter complications and it is convenient to use and safety toward the renal function. Therefore, the concomitant use of SACB and transdermal buprenorphine can be an effective pain control method after TKA.

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

The Changes of Brain Injury Markers(S100-$\beta$, Neuron-Specific enolase) After Retrograde Cerebral Perfusion Under Total Circulatory Arrest in Pigs (돼지에서 역행성 뇌관류 시행 후 혈청 및 소변의 뇌손상 관련지표(S100-$\beta$, Neuron-specific enolase)의 변화)

  • 김상윤;김만호;김경환
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.847-853
    • /
    • 2002
  • We previously published the data that proved the safety of retrograde cerebral perfusion for 120 minutes. At this time, we planned to check the neuron-specific enolase and S100-$\beta$ in serum and urine to assess the possibility of early detection of cerebral injury. Material and Method: We used pigs(Landrace species) weighing 35 kg and performed RCP for 120 minutes. After the weaning of cardiopulmonary bypass, we observed the pigs for another 120 minutes. Systemic arterial pressure, central venous pressure, and serum and urine levels of neuron-specific enolose (NSE) and S100$\beta$ protein were checked. Central venous pressure during RCP was maintained in the range of 20 to 25 mmHg. Result: Serum levels of NSE(ng/$m\ell$) were 0.67$\pm$0.18(induction of anesthesia), 0.53$\pm$0.47(soon after CPB), 0.44$\pm$0.27(20min alter CPB), 0.24$\pm$0.09(RCP 20min), 0.37$\pm$0.35(RCP 40min), 0.33$\pm$0.21 (RCP 60min), 0.37$\pm$0.22(RCP 80min), 0.41$\pm$0.23(RCP 100 min), 0.48$\pm$0.26(RCP 120min), 0.42$\pm$0.29(30min after rewarming), 0.35 $\pm$0.32(60min after rewarming, 0.42$\pm$0.37(CPBoff 30min), 0.47$\pm$0.34(CPBOff 60min), 0.47$\pm$0.28(CPBOff 90min), and 0.57$\pm$0.29(CPBOff 120min). There was no statistically significant difference in levels between before and after RCP(ANOVA, p>0.05). Urine levels of NSE also showed no statistically significant difference in levels between before and after RCP. There was no correlation between urine and serum levels of NSE(Pearson correlation, p>0.05). Serum levels of S100$\beta$ protein(ng/$m\ell$) during the same time frames were 0.14$\pm$0.08, 0.15$\pm$0.07, 0.22$\pm$0.15, 0.23$\pm$0.07, 0.28$\pm$0.10, 0.40$\pm$0.05, 0.47$\pm$0.03, 0.49$\pm$0.12, 0.43$\pm$0.11, 0.46$\pm$0.15, 0.62$\pm$0.17, 0.77$\pm$0.21, 0.78$\pm$0.23, 0.77$\pm$0.23, and 0.82$\pm$0.33. There was statistically significant difference in levels between before and after RCP(ANOVA, p<0.05). Urine levels of NSE also showed statistically significant difference in levels between before and after RCP(ANOVA, p<0.05). There was significant correlation between urine and serum levels of NSE(Pearson correlation, p<0.05). Conclusion: The author observed the increase in serum and urine levels of S100$\beta$ after 120 minutes of RCP. Significant correlation between serum and urine levels was observed. The results were considered to be the fundamental data that could correlate this study with human-based study.

The Effect and Safety of Alveolar Recruitment Maneuver using Pressure-Controlled Ventilation in Acute Lung Injury and Acute Respiratory Distress Syndrome (급성폐손상과 급성호흡곤란증후군 환자에서 압력조절환기법을 이용한 폐포모집술의 효과와 안정성)

  • Chung, Kyung Soo;Park, Byung Hoon;Shin, Sang Yun;Jeon, Han Ho;Park, Seon Cheol;Kang, Shin Myung;Park, Moo Suk;Han, Chang Hoon;Kim, Chong Ju;Lee, Sun Min;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.5
    • /
    • pp.423-429
    • /
    • 2007
  • Background: Alveolar recruitment (RM) is one of the primary goals of respiratory care for an acute lung injury (ALI) and acute respiratory distress syndrome (ARDS). The purposes of alveolar recruitment are an improvement in pulmonary gas exchange and the protection of atelectrauma. This study examined the effect and safety of the alveolar RM using pressure control ventilation (PCV) in early ALI and ARDS patients. Methods: Sixteen patients with early ALI and ARDS who underwent alveolar RM using PCV were enrolled in this study. The patients data were recorded at the baseline, and 20 minutes, and 60 minutes after alveolar RM, and on the next day after the maneuver. Alveolar RM was performed with an inspiratory pressure of $30cmH_2O$ and a PEEP of $20cmH_2O$ in a 2-minute PCV mode. The venous $O_2$ saturation, central venous pressure, blood pressure, pulse rate, $PaO_2/FiO_2$ ratio, PEEP, and chest X-ray findings were obtained before and after alveolar RM. Results: Of the 16 patients, 3 had extra-pulmonary ALI/ARDS and the remaining 13 had pulmonary ALI/ARDS. The mean PEEP was 11.3 mmHg, and the mean $PaO_2/FiO_2$ ratio was 130.3 before RM. The $PaO_2/FiO_2$ ratio increased by 45% after alveolar RM. The $PaO_2/FiO_2$ ratio reached a peak 60 minutes after alveolar RM. The Pa$CO_2$ increased by 51.9 mmHg after alveolar RM. The mean blood pressure was not affected by alveolar RM. There were no complications due to pressure injuries such as a pneumothorax, pneumomediastinum, and subcutaneous emphysema. Conclusion: In this study, alveolar RM using PCV improved the level of oxygenation in patients with an acute lung injury and acute respiratory distress syndrome. Moreover, there were no significant complications due to hemodynamic changes and pressure injuries. Therefore, alveolar RM using PCV can be applied easily and safely in clinical practice with lung protective strategy in early ALI and ARDS patients.