• Title/Summary/Keyword: 환상

Search Result 618, Processing Time 0.035 seconds

Recent study of Acupuncture in Treatment of Urianry Disturbance (배뇨장애(排尿障碍)에 대한 침구치료(鍼灸治療)의 연구동향(硏究動向))

  • Kim, Kyung-tai;Ko, Young-jin;Kim, Yong-suk;Kim, Chang-hwan
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.123-135
    • /
    • 2005
  • Objective : The aim of this study was to rivew systemically literature and clinical trials in the treatment of urinary incontinence or lower urinary tract syndrome(LUTS). Methods : Computerized literature searches were carried out on two electronic database, and computerized searching on some korea oriental medicine journals in library of Kyung-Hee Medical center. Results : 1. Three reports of review study, six reports of experimental study and fourteen reports of clinical trials were collected and reviewed. Three reports of review study were all printed in the korea oriental medicine journal. From 2000, researches and studies have been increased in quantity and improved in quality. 2. Urinary disturbance include variable symptoms of lower urinary tract symptoms, urinary incontinence, in theaspect of Oriental medicine these symptoms are anurin, dysuria, urinary incontinence, nochumal enuresis, uracratia and so on. 3. Roughly physiological procedure of Acupuncture in Treatment of Urianry Disturbance may be that effect of acupuncture stimulation for parasympathetic nerve, sleep-arousal system in cerebrum, pontine/spinal urination center and pudendal/pelvic nerve affect bladder in expansion of bladder capacity, inhibition of urinary contraction and affection in periurethral muscle by continuous excitement of spinal annular circuit and synapse of neuron. 4. Clinical result for acupuncture treatment in urinary disturbance is summarized that acupuncture treatment in urianation disturbance of Neurogenic Bladder, Incontinence, Cycitis, Nocturnal Enuresis, Prostatitis/Pelvic Pain Syndrom and so on is significant clinical trials and technique. Conclusion : Hereafter, in the old age society these variable urinary disturbance patients are increased and desire of treatment may be also increased. So study of various and formal treatment and tecnnique is needed.

  • PDF

Clinical Characteristics of Patients with Taste Disorders (미각 장애 환자의 임상적 특성에 관한 연구)

  • Lee, Eun-Jin;Park, Won-Kyu;Nam, Jin-Woo;Yun, Jong-Il;Kho, Hong-Seop
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.4
    • /
    • pp.341-351
    • /
    • 2009
  • There is tremendous variability in the ways patients present with taste problems. Because of complex and multifactorial etiological background, it is not simple to evaluate patients with taste disorders. Accurate assessment of patients' status by prudent, thorough history taking and symptom analysis is the most essential for exact diagnosis of taste disorders. The aim of this study was to investigate the clinical characteristics of patients with taste problems as a primary complaint. Consecutive series of 50 patients (12 males and 38 females, mean age $53.6\;{\pm}\;14.7$ years) were included for the present study. All subjects were requested to complete a comprehensive questionnaire. Clinical evaluation procedures included oral examination, interview, questionnaire analysis, panoramic radiography, blood test and measurement of salivary flow rate. The obtained results were as follows: 1. Among the patients, 36 patients (72%) complained of oral mucosal pain or burning sensation. Of these patients, 18 patients (36%) were diagnosed as burning mouth syndrome. 2. Nineteen patients (38%) complained of subjective oral dryness. The flow rate of unstimulated whole saliva was less than 0.1 mL/min in 14 patients (28%) and 17 (34%) had a stimulated whole salivary flow rate of less than 0.5 mL/min. 3. Among the types of taste disorders, hypogeusia, the most frequently reported, was found in 25 patients (50%), dysgeusia in 18 patients (36%), phantogeusia in 15 patients (30%), hypergeusia in 10 patients (20%), and ageusia in 5 patients (10%). Nineteen patients (38%) reported more than one type of taste disorder and the most frequent combination was dysgeusia + hypogeusia (n=6, 12%). 4. Based on data from the medical and dental histories and examinations, the patients were assigned to 12 probable causal categories. Taste disorders due to oral mucosal diseases and idiopathic taste disorder were the most frequent (n=9; 18%, each), followed by psychogenic taste disorder (n=8; 16%), drug-induced taste disorder (n=7; 14%), and taste disorder due to dry mouth (n=6; 12%). These 5 categories of taste disorder accounted for 78% of all cases in this study.

Derivation of rock parameters from Televiewer data (텔레뷰어에 의한 토목설계 매개변수의 산출)

  • Kim Jung-Yul;Kim Yoo-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.137-155
    • /
    • 1999
  • Recently, Televiewer(Borehole Acoustic Scanner(Televiewer)) has come to be widely used specially for the general engineering construction design. The Televiewer tool using a focussed acoustic beam is to detect the amplitude and traveltime of each reflected acoustic signal at the wall, resulting in the amplitude- and traveltime image respectively. Fractures can be well detected, because they easily scatter the acoustic energy due to the highly narrow beam. In addition, the drilling work will rough the borehole wall so that the acoustic energy can be scattered simply due to the roughness of the wall. Thus, the amplitude level can be directed associated with the elastic properties(impedance) and the hardness of the rock as well. Meanwhile, the traveltime image provides an information about the borehole shape and can be converted to a high precision 3D caliper log(max. 288 arms). In this paper, based on the high resolution of Televiewer images, general evaluation methods are illustrated to derive very reliable rock parameters.

  • PDF

The Comparison of Knee Joint Displaying between The Anteroposterior Weight Bearing View and the Metatarsophalangeal View with Osteoarthritis Patients (골관절염 환자의 촬영방법에 대한 고찰 : AP-WB(Weight-bearing AP), MTP(semiflexed) 촬영법의 비교 고찰을 중심으로)

  • Jeon, Ju-Seob;Park, Hwan-Sang;Moon, Il-Bong;Moon, Ju-Wan;Choi, Nam-Kil;Kim, Chang-Bok;Eun, Sung-Jong
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.97-103
    • /
    • 2005
  • Objective : The aim of this study was to compare the knee joint displaying between the anteroposterior weight bearing(AP-WB) View and the metatarsophalangeal(MTP) view for assessing joint space narrowing(JSN) and osteophytes in osteoarthritis patients. Subjects and Materials : Two hundreds of twenty patients(38 men) who came rheumatoid caused by knee pain, had both AP-WB and MTP views taken on a day. Radiographs were evaluated independently by 13 experienced observers(3 orthopedics surgeon, 2 rheumatogist, 3 radiologist, 5 radiological technologist) They assessed JSN and osteophytes using by PACS monitor JSN was scored by the optic evaluation to the nearest at the narrowest point in medial compartments of the tibiofemoral joint in both knees. Osteophytes were graded 0 to 3(bad 0, not bad 1, good 2 and very good 3) according to a standard atlas. All exam was using by Philips(Buckey Diagnostic-TH) X-ray material. Exposure condition was 60 kv, 8 mAs and 100 cm focus to film distance. Results : JSN was scored $1.32{\pm}0.050$ in AP-WB view, $2.51{\pm}0.046$ in MTP view. MTP view of JSN score is higher to AP-WB view significantly(p<0.05). Osteophytes scored $2.14{\pm}0.054$ in AP-WB view, $2.10{\pm}0.054$ in MTP view. There was no difference(p<0.05) between MTP view and AP-WB view in osteophytes. But MTP view was more reproducible than AP-WB view Conclusions : Joint space narrowing is most important factor to diagnosis with knee joint Osteoarthritis patients. This study was summarized as follows; In comparision of JSN, MTP view was more widely displayed than AP-WB view. In comparision of Osteophytes, there was no difference between MTP view and AP-WB view. It was concluded MTP view was more useful method to diagnosis of knee joint Osteoarthritis patients.

  • PDF

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Effects of Seasonal Wiring Treatments on Fruit Quality, Carbohydrates, and Mineral Nutrients of 'Niitaka' (Pyrus pyrifolia Nakai) Pear Trees (시기별 Wiring 처리가 '신고' 배의 과실품질 및 수체 내 탄수화물과 무기성분에 미치는 영향)

  • Seo, In-Ho;Song, Jang-Hoon;Seo, Ho-Jin
    • Korean Journal of Organic Agriculture
    • /
    • v.27 no.1
    • /
    • pp.33-44
    • /
    • 2019
  • This study was initiated to find possibility of substitute of gibberellin acid and to prevent negative girdling effect such as slow growth of 'Niitaka' (Pyrus pyrifolia Nakai) trees, a major pear cultivar, at harvest and at 60-, 90-, and 120-d after storage. Seasonal wiring with 3.0-mm-diameter were applied on the main branch at 70, 80, 90, 110, and 130 days after full bloom (DAF) to compare the fruit quality and storability. Fruit weight and sugar contents were the greatly increased by the wiring treatment at 110 DAF, with the lowest values observed for the wiring at 70 DAF. All the wiring treatments reduced fruit acidity but did not affect fruit firmness. a-value on fruit skin was the highest for wiring at 110 DAF and 130 DAF, advancing fruit ripening. The lowest fruit weight loss was occurred at wiring at 110 DAF. a-value on fruit skin was the highest for wiring at 90 DAF and 110 DAF. Wiring at 80 DAF the most increased floral bud diameter, resulting in the lowest L:D ratio of 1.74 observed. As for the mineral nutrients concentrations of floral buds, the concentration of K (0.63%) and Mg (0.31%) were the highest after 80 DAF wiring treatment, whereas Ca and P concentrations did not differ among treatment plots. The leaf K concentrations was the highest in the 130-day wiring treatment (0.76%) and in the control plot (0.78%), whereas there was no significant difference in the concentrations of either Ca or P among treatment plots. Short periods of wiring increased foliar Mg concentrations. In floral buds, carbohydrates showed a tendency for accumulating at a lower concentrations (7.75%) after 70 DAF wiring treatment, which was a relatively short treatment period. On the other hand, the carbohydrate concentrations in leaves showed a tendency for accumulating at lower concentrations after 130 DAF wiring treatment (2.51%), which is a long treatment period, and in the control plot (2.43%). Wiring increased the size and sugar content of fruits, and influenced fruit storability. For the wiring treatment period was delayed, the carbohydrate concentration in flower buds showed curvilinear correlation and the negative correlation with the carbohydrate in leaf tissue.

A Case Study on Introducing Vita Parcours as Forest Leisure Sports Facility in Saneum Healing Forest (산음 치유의 숲 Vita Parcours 도입 사례 연구 - Vita Parcours 도입을 사례로 -)

  • Lee, Jin-Kyu;Kim, Ki Weon
    • The Journal of the Korean Institute of Forest Recreation
    • /
    • v.22 no.4
    • /
    • pp.71-81
    • /
    • 2018
  • It is necessary to build a quality-enhancing forest leisure sports facility according to values that value life quality, national forest policy. Vita Parcours (fitness trails) is found to be the activities highly convenient, so their introduction and promotion in Korea should be highly considered. field survey was necessary to explore the possibility of installing Vita Parcours. Several sites were selected, such as Asean recreational forest, Unaksan recreational forest, Yumyeongsan recreational forest, Saneum recreational forest, Jungmisan recreational forest and National center for forest therapy. At these locations, we explored the current status of forest facilities and forest trails. A total number of 31 exercise facilities has been identified and surveyed, some of which are located on the trails (2), alongside the trail (9), alongside trail boundaries (2) or represent facilities suitable for both outdoor and indoor exercise within the forest (18), all of whom provide location for 44 different exercise routines (flexibility exercises (23), endurance (12) and strength exercises (9)). Field work also included identification of forests paths, the total number of whom was 34 paths - 30 identified as trails, 2 as hiking trails, 1 as a forest path for relaxation and healing and 1 as an exploratory path. Regarding the structure and shape of these trails, 32 was straight in shape and only 2 designed as a circular forest trails. Average length of these trails was 652.2m with the highest and the lowest point altitude difference of 60m, on average. Saneum recreational forest provide the most suitable site/environment for Vita Parcours and as a result of this, Saneum recreational forest is proposed as a location to support the endeavors in promotion of these valuable forest fitness trails. Among the forest paths at this site, a forest path which has a length of 1.84km and 73.0m the highest and the lowest point altitude difference was selected as the most suitable, and may be equipped with necessary stations for exercise or obstacles. In addition, if these trails are to be introduced and welcomed by its users, we must assure that they are properly maintained.

Effects of Soil Hardness on the Root Distribution of Pinus rigida Mill. Planted in Association with Sodding Works on the Denuded Land (사방시공지(砂防施工地)에 있어서 리기다소나무의 수근(樹根)의 분포(分布)에 미치는 토양견밀도(土壤堅密度)의 영향(影響))

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.66-76
    • /
    • 1982
  • Soil harness represents such physical properties as porosity, amount of water, bulk density and soil texture. It is very important to know the mechanical properties of soil as well as the chemical in order to research the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to grip soil hardness by soil layer and also to grasp the root distribution and the correlation between soil hardness and the root distribution of Pinus riguda Mill. planted on the denuded hillside with sooding works by soil layer on soil profile. The site investigated is situated at Peongchang-ri 13, Kocksung county, Chon-nam Province. The area is consisted of 3.63 ha having on elevation of 167.5-207.5 m. Soil texture is sandy loam and parant rock in granite. Average slope of the area is $17^{\circ}-30^{\circ}$. Soil moisture condition is dry. Main exposure of the area is NW or SW. The total number of plots investigated was 24 plots. It divided into two groups by direction each 12 plots in NW and SW and divided into three groups by the position of mountain plots in foot of mountain, in hillside, and in summit of mountain, respectively. Each sampling tree was selected as specimen by purposive sampling and soil profile was made at the downward distance of 50cm form the sampling tree at each plot. Soil hardness, soil layer surveying, root distribution of the tree and vegetation were measured and investigated at the each plot. The soil hardness measured by the Yamanaka Soil Hardness Tester in mm unit. the results are as follows: 1) Soil hardness increases gradually in conformity with the increment of soil depth. The average soil indicator hardness by soil layer are as follows: 14.6mm in I - soil layer (0-10cm in depth from soil surface), 16.2mm in II - soil layer (10-20cm), 17.2 in III - soil layer (20-30cm), 18.3mm in IV - soil layer(30-40cm), 19.8mm in V - soil layer (4.50mm). 2) The tree roots (less than 20mm in diameter) distribute more in the surface layer than in the subsoil layer and decrease gradually according to the increment of soil depth. The ratio of the root distribution can be illustrated by comparing with each of five soil layers from surface to subsoil layer as follows: I - soil layer; 31%, II - soil layer; 26%, III - soil layer; 18%, IV - soil layer; 12%, V - soil layer; 13%, 3) Soil hardness and tree root distribution (less than 20mm in diameter) of Pinus rigida Mill. correlate negatively each other; the more soil hardness increases, the most root distribution decreases. The correlation coefficients between soil hardness and distribution of tree roots by soil layer are as follows: I - soil layer; -0.3675 (at the 10% significance level), II - soil layer; -0.5299 (at the 1% significance level), III - soil layer; -0.5573 (at the 2% significance level), IV - soil layer; -0.6922 (at the 5% significance level), V - soil layer; -0.7325 (at the 2% significance level). 4) the most suitable range of soil hardness for the growth of Pinus rigida Mill is the range of 12-14.9mm in soil indicator hardness. In this range of soil indicator hardness, the root distribution of this tree amounts to 41.8% in spite of 33% in soil harness and under the 20.9mm of soil indicator hardness, the distribution amounts to 93.2% in spite of 82% in soil hardness. Judging from above facts, the roots of Pinus rigida can easily grow within the soil condition of 20.9mm in soil indicator hardness. 5) The soil layers are classified by their depths from the surface soil.

  • PDF