• Title/Summary/Keyword: 환상유동

Search Result 48, Processing Time 0.026 seconds

Prediction of Critical Heat Flux for Saturated Flow Boiling Water in Vertical Narrow Rectangular Channels (얇은 수직 사각유로에서의 포화비등조건 임계열유속 예측)

  • Choi, Gil Sik;Chang, Soon Heung;Jeong, Yong Hun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.12
    • /
    • pp.953-963
    • /
    • 2015
  • There is an increasing need to understand the thermal-hydraulic phenomena, including the critical heat flux (CHF), in narrow rectangular channels and consider these in system design. The CHF mechanism under a saturated flow boiling condition involves the depletion of the liquid film of an annular flow. To predict this type of CHF, the previous representative liquid film dryout models (LFD models) were studied, and their shortcomings were reviewed, including the assumption that void fraction or quality is constant at the boundary condition for the onset of annular flow (OAF). A new LFD model was proposed based on the recent constitutive correlations for the droplet deposition rate and entrainment rate. In addition, this LFD model was applied to predict the CHF in vertical narrow rectangular channels that were uniformly heated. The predicted CHF showed good agreement with 284 pieces of experimental data, with a mean absolute error of 18. 1 % and root mean square error of 22.9 %.

Local Convective Mass Transfer and Flow Structure Around a Circular Cylinder with Annular Fins (환상핀이 부착된 원봉 주위의 3차원 박리 유동구조 및 물질전달 특성 해석)

  • 박태선;성형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.2132-2146
    • /
    • 1991
  • Extensive experiments were carried out to investigate the mass transfer and flow structures around a circular cylinder with annular fins in crossflow. The naphthalene sublimation method was employed to measure the circumferential and longitudinal variations of mass transfer from the circular cylinder between annular fins and H is the height of the fin from the cylinder surface. A remarkable enhancement of mass transfer due to the horseshoe vortices was observed near the corner junction between the annular fin and circular cylinder. The present results indicate that the local circumferential Sherwood number shows the higher values on the front stagnation point. The maximum augmentation of mass transfer rate at the center of cylinder is found near L/H-0.15 due to the separation bubble along the annular fins. The secondary flows, which are the corner vortices V2 and V3 near the end wall of the annular fin, are fairly predicted from the distributions of local Sherwood number in the spanwise direction. The average Sherwood number of overall surface at L/H=0.15 is larger 2.0 times than that of without annualr fins. The correlations of total average mass transfer rate with L/H and Re$_{L}$ can also be obtained.d.

An Experimental Study on Flow Characteristics of R134a in a Small Diameter Tube (세관내 R-134a의 유동특성에 관한 실험적 연구)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1307-1312
    • /
    • 2007
  • The flow characteristics of R-134a in a small diameter tube was investigated experimentally. An experimental apparatus was consisted of a magnetic gear pump, an evaporator, a sight-glass, a condenser and a measurement instruments. The sight-glass for flow pattern observations was located at the inlet and outlet of the evaporator. The experiment was carried out to show the flow characteristics of R-134a in a small diameter tube. Mass flux of refrigerants was ranged from 100 to 1000 $kg/m^2s$, the saturation temperature was $30^{\circ}C$. In the flow patterns during evaporation, the annular flow in a 2 mm inner diameter tube occurred at a relatively lower quality and mass velocity, compared to that in a 8 mm inner diameter tube. The evaporation flow pattern in a small diameter tube has been shown major deviations with the Baker, Mandhane and Taitel-Dutler's flow pattern maps but it was similar to the Dobson's flow pattern map.

  • PDF

An Expermental and Numerical Study of Natural Convection in the Annuli between Horizontal Confocal Elliptic Cylinders (수평동심 환원사이의 환상공간에서의 자연대류에 관한 수치 및 실험적 연구)

  • Lee, J. H.
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.2
    • /
    • pp.160-168
    • /
    • 1982
  • 수평으로 놓여진 2개의 동심타원 사이의 환상공간에서의 자연대류현상이 수치계산 및 실험적으로 연구되었다. 수치적 연구는 정상 2차원 층류유동영역에서 수행되었으며 유선 및 등온선이 구하여 졌다. 또한 특수한 경우로서 수평동심원 사이의 환상공간에 관한 기존연구와 비교하여 좋은 일치 를 보았다. 실험적 연구에서는 3개의 실험모델을 제작하였으며 마하젠더 간섭계에 의한 간섭사진 으로부터 등온선 분포를 얻었으며 아울러 유동에 관한 정보도 얻을 수 있었다. 실험과 수치계산 결과는 상당히 좋은 일치를 보였으며 기존 동심원환상공간에 편심율이 추가된 이론전개 및 수치 계산방법의 적합성을 알 수 있었고 이로서 환상공간에서의 자연대류에 관한 연구를 확장시켰다.

Effects of Outflow Area on Pool Boiling in Vertical Annulus (출구유로 단면적이 수직 환상공간 내부의 풀비등에 미치는 영향)

  • Kang, Myeong-Gie
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.377-385
    • /
    • 2013
  • To identify the effects of an outflow area on pool boiling heat transfer in a vertical annulus, three different flow restrictors were studied experimentally. For the test, a heated tube of smooth stainless steel and water at atmospheric pressure were used. Both annuli with open and closed bottoms were considered. To validate the effects of the outflow area on the heat transfer, the results of the annulus with the restrictor were compared with the data for the plain annulus without the restrictor. The reduction of the outflow area ultimately results in a decrease in the heat transfer. As the outflow area is very small, a slight increase in heat transfer is also observed. The major cause of this tendency is explained as the difference in the intensity of liquid agitation cause by the movement of coalesced bubbles. It is identified that the convective flow, pulsating flow, and evaporative mechanism are considered as the important mechanisms.

Comparison and Analysis of Tomography Methods for Reconstruction of Three-dimensional Density Distributions in Two-phase Flows (2상유동장 내 3차원 밀도 분포 재건을 위한 토모그래피 기법의 성능 비교 분석)

  • Ko, Han-Seo;Kim, Yong-Jae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.545-556
    • /
    • 2002
  • Bubble behaviors in two-phase flows have been analyzed by tomography methods such as an algebraic reconstruction technique (ART) and a multiplicative algebraic reconstruction technique (MART). Initially, a bubbly flow and an annular flow have been investigated by cross-sectional view using computer synthesized phantoms. Two tomography methods have been compared to obtain more accurate results of the two-phase flows. Then, reconstruction of three-dimensional density distributions of phantoms with two and three bubbles have been accomplished by the MART method which provided the better results for the two-dimensional reconstructions accurately to analyze the bubble behaviors in the two-phase flow.

Prediction of Fishtailing in Ring Rolling by the 3-D Rigid-Plastic Finite Element Method (환상압연공정에서 측면유동에 의한 어미현상(Fishtailing)의 예측에 관한 연구)

  • 양동열
    • The Korean Journal of Rheology
    • /
    • v.4 no.1
    • /
    • pp.35-45
    • /
    • 1992
  • 어미현상의 예측을 위하여 사각단면이 링을 환상압연하는 공정을 3차원 강소성 유 한요소법으로 해석하였다. 환상압연공정의 점진적이고 변형영역이 두롤 사이 근처로 국한되 므로 계산시간을 줄이기 위하여 두롤사이를 통과하는 부분만을 해석하였다. 변형도율의 분 포, 압연력, 구동롤의 토오크, 링과 롤 사이의 접촉면에서의 압력분포 및 변형된 링의 단면 모양을 계산하였다. 압연력, 구동롤의 토오크, 특히 변형된 링의 단면모양, 즉 어미현상은 계 산결과와 실험이 잘 일치하였다.

  • PDF

Prediction of condensation heat transfer coefficients inside horizontal tube in annular flow regime (환상유동 영역에서의 수평관내 응축 열전달계수 예측)

  • Kwak, Kyung-Min;Bae, Chul-Ho;Jung, Mo;Lee, Sang-Chun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.732-742
    • /
    • 1998
  • Prediction method for heat transfer coefficients in a horizontal smooth tube with forced convection condensation is proposed. In this paper, the analogy between momentum and heat transfer was applied to an annular flow regime and the logarithmic velocity distribution is applied to describe the velocity profile within the liquid film. Prediction results are compared with those of experimental ones. The test refrigerants are R113, R22, R134a, R407C(R33/R125/R134a, 23/25/52 wt%), R410A(R32/R125, 50/50 wt%) and R134a+R123(R134a/R123, 85.5/14.5 wt%) which are used under operating conditions in a condenser of air-conditioner. The proposed prediction method shows good agreement with experimental data within$\pm 30%$ for pure refrigerants. For the mixture refrigerants including the ternary mixture refrigerant R407C, condensation heat transfer from this study are higher than those from experiments. By correcting the constant in two-phase frictional multiplier, the predicated heat transfer coefficients become similar to the experimental results.

  • PDF

이론적 강제대류CHF 해석 모델의 연구 현황 및 성능 평가

  • Kwon, Hyuk-Sung;Jeon, Tae-Hyun;Hong, Sung-Duk;Hwang, Dae-Hyun;Park, Chul
    • Nuclear Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.918-931
    • /
    • 1995
  • 임계열속을 예측하는 기존의 여러 방법중 임계열속 발생 역학구조에 근거한 이론적 접근 방법은 여러 유동형태(Flow pattern)별로 연구되고 있으며, 대표적으로 환상유동에서의 LFD(Liquid Film Dryout) 이론, 기포류에서의 BBLD(Bubble Boundary Layer Dryout) 흑은 LNID(Local Nucleation Initiated Dryout)이론 등이 제시되고 있다. 본 논문에서는 일반적으로 원자로 조건에 서 적용될 수 있는 LFD이론과 BBLD 이론에 대하여 대표적인 모델들을 소개하고 특성을 검토하였다. 특히 BBLD 이론중에서 기포군집 (Bubble coalescence) 모델과 층류막 드라이 아웃(Sublayer dryout) 모델에 대해서는 원형관에서의 임계열속 시험자료를 사용하여 각 모델의 예측 성능 및 특성을 평가하였다. 평가 결과, 기포군집 모형인 Weisman 모델의 예측성능이 가장 우수했으며 아울러 층류막 드라이아웃 모델인 Katto 모델과 Mudawwar 모델은 구성 인자중 기포군속도와 층류막 두께와의 관계가 보다 정확히 모형화되야 할 것으로 판단된다.

  • PDF

Heat transfer characteristic and flow pattern investigation in micro-channels during two-phase flow boiling (이상 유동 비등 시 마이크로 채널에서의 열전달 특성과 유동양식 조사)

  • Choi, Yong-Seok;Lim, Tae-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.696-701
    • /
    • 2015
  • Two-phase flow boiling experiments were conducted in 15 micro-channels with a depth of 0.2 mm, width of 0.45 mm, and length of 60 mm. FC-72 was used as the working fluid, and the mass fluxes ranged from 200 to $400kg/m^2s$. Tests were performed over a heat flux range of $5-40kW/m^2$ and vapor quality range of 0.1-0.9. The heat transfer coefficient sharply decreased at a lower heat flux and then was kept approximately constant as the heat flux is increased. Based on the measured heat transfer data, the flow pattern was simply classified into bubbly, slug, churn, and wavy/annular flows using the existing method. In addition, these classified results were compared to the transition criterion to wavy/annular regime. However, it was found that the existing transition criterion did not satisfactorily predict the transition criterion to annular regime for the present data.