• Title/Summary/Keyword: 환기 시뮬레이션

Search Result 175, Processing Time 0.026 seconds

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

A Study on the Simulation of Natural Ventilation Effect for Single-sided Casement Window as Opening Types (케이스먼트 창호 개폐방식에 따른 자연환기 효과에 관한 시뮬레이션 연구)

  • Choi, Taehwoan;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.57-62
    • /
    • 2007
  • At the moment, the reduction of building energy consumption is a unavoidable task of mankind for conserving global environment. Decreasing overall U-value of building envelope and air infiltration, especially in Korean climate condition with clear four seasons, are the obvious solutions for the objective. Thus low glazing ratio with small window openings are required for heating and cooling load reduction in buildings. Using larger window openings could provide better natural ventilation but it also increases the direct solar radiation penetration into indoor space, heat gain in summer and heat loss in winter. On the other hand, the ventilation rates decreasing problem with smaller window openings could be occurred. As a solution for it, the use of casement window can cause increasing natural ventilation rates by wing wall effect. This paper focuses on deduce the most efficient opening type of casement window in Korean climate. To estimate ventilation performance of each opening types, CFD simulation was used. The best performance of opening type in every wind direction is opening both windows to the center and the most appropriate opening type for Korean climate is also opening both windows to center.

Simulation and Verification Experiment of Cooling and Heating Load for a Test Space with Forced Ventilation (강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험)

  • Kim, Dong-Hyuk;Hong, Hi-Ki;Yoo, Ho-Seon;Kim, Ook-Joong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.947-954
    • /
    • 2006
  • Building energy consumption according to the ventilation has been considered to be an important subject. The purpose of this study is to investigate the cooling and heating loads in a test space with a forced ventilating system. In the test space, on/off controlled air-conditioning and forced ventilating facility were operated between 8 : 30 to 21 : 00 during 4 days and some important data like temperatures and energy consumption were measured to obtain actual thermal loads. The simulation was carried out in a mode of temperature level control using a TRNSYS 15.3 with a precisely measured air change amount and performance data of air-conditioner. Heating load and cooling load including sensible and latent were compared between by experiment and by simulation. Both of thermal loads associated with ventilation show a close agreement within an engineering tolerance.

The Effects of Mechanical Ventilation Simulation on the Clinical Judgment and Self-confidence of Nursing Students (중환자간호 기계환기 시뮬레이션교육이 간호학생의 임상판단력과 자신감에 미치는 영향)

  • Ha, Yi Kyung;Koh, Chin Kang
    • Perspectives in Nursing Science
    • /
    • v.9 no.2
    • /
    • pp.119-126
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the effects of mechanical ventilation simulation on the clinical judgment and self-confidence of nursing students. Methods: This study was a quasi-experimental study. From one university, 118 undergraduate nursing students participated in this study. Sixty students were in the intervention group, and fifty-eight students were in the control group. A simulation scenario utilizing a high-fidelity human simulator focusing on nursing care for patients with a mechanical ventilator was developed for this study. Data were collected with a self-report survey method before the intervention, right after intervention, and two weeks later. Results: Students in the intervention group showed significantly higher increases in clinical judgment and self-confidence than those in the control group at the immediate posttest. Moreover, 2 weeks later, the increase in clinical judgment and self-confidence from the pretest among the intervention group was significantly larger than those in the control group. Conclusion: Utilizing simulation education focusing on patients with a mechanical ventilator may contribute to training more competent nurses in the area of critical care nursing. It may also serve to provide a better critical care environment for the safety and health of patients.

  • PDF

Heat Transfer Characteristics of Plate-fin Heat Exchanger Using LNG FPSO Liquefaction Process (LNG FPSO 액화공정에 적용되는 플레이트 핀 열교환기의 열전달 특성)

  • Yoo, Sun-Il;Kim, Hyun-Woo;Jung, Young-Kwon;Yoon, Jung-In;Park, Seung-Ha;Kim, Chang-Su
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.798-805
    • /
    • 2010
  • There are no domestic researches of plate fin heat exchanger in the field of cryogenic such as LNG FPSO liquefaction plant. In this study, condensing heat transfer characteristics of nitrogen according to three kinds of fin type in the plate fin heat exchanger were analyzed through simulation and experiment to secure independent technologies. In the simulation, nitrogen was condensed at 69bar and $-140^{\circ}C$ in serrated and wavy fin of plate-fin heat exchanger. The serrated fin shows the highest value of local heat transfer coefficient, followed by wavy and plain fin. The experimental results were shown errors less than 12% comparing with the simulation results.

Fault Detection and Diagnosis (FDD) Using Nonlinear Regression Models for Heat Exchanger Faults in Heat Pump System (비선형회귀모델을 이용한 히트펌프시스템의 열교환기 고장에 대한 고장감지 및 진단에 대한 연구)

  • Kim, Hak-Soo;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1111-1117
    • /
    • 2011
  • This paper proposed a fault detection and diagnosis (FDD) algorithm using nonlinear regression models, focusing especially on heat exchanger faults. This research concerned four working modes: those with no fault, evaporator fault, condenser fault, and evaporator and condenser faults. This research used no fault mode data to create an FDD algorithm. Using the no fault mode data, correlation functions for predicting the degree of superheat or subcool of heat exchangers (an evaporator and a condenser) were derived. Each correlation function has five inputs and one output. Based on these correlation functions, it is possible to predict the degree of superheat or subcool of each heat exchanger under various working conditions. The FDD algorithm was developed by comparing the predicted value and the simulation value. The FDD algorithm works well in all four working modes.

Effect of the Eave Width and the Vertical Rain Proof Facilities on Ventilation and Air Velocity Distribution in Hanwoo Loose Barn (개방한우사의 처마와 수직 비가림시설이 환기와 풍속 분포에 미치는 영향)

  • Lee, Seung-Joo;Jo, Hyeon-Jun;Kim, Dong-Hoon;Gutierrez, Winson M.;Chang, Hong-Hee
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.87-93
    • /
    • 2011
  • This study was carried out to determine more effective way in eave structure between lengthening roof just as standard plan and replacing 3 types of vertical rain roof facility by using computational fluid dynamics (CFD) simulation to reduce the heat stress of Hanwoo, increase the effect of dryness of room floor, rain proof and ventilation efficiency. The simulation which did with mean wind velocity (1.2 m/s) result showed that the case of lengthening of roof just as standard design was more effective than the cases of vertical establishment of rain proof facility.

Numerical Study for Influence of Crossdraft Directions and Magnitudes on Push-Pull Ventilation Systems (푸시풀 후드시스템의 방해기류 방향 및 세기의 영향에 관한 수치적 연구)

  • Li, Xiao Yu;Kim, Tae Hyeung;Piao, Cheng Xu;Ha, Hyun Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.161-170
    • /
    • 2008
  • 푸쉬-풀 환기시스템은 도금조와 같이 흡인해야 할 거리가 상대적으로 긴 경우에 많이 사용되고 있다. 그러나, 창문이나 출입문을 통한 방해기류가 푸쉬-풀 환기시스템의 오염물질 제어효율을 심각하게 훼손시키고 있다고 추측하고 있으나 이에 대한 세부적인 연구가 부족한 상태에 있다. 따라서, 본 연구에서는 전산유체역학(Computational fluid dynamics)을 이용하여 푸쉬-풀 환기시스템에서의 방해기류의 방향과 세기가 흡인효율에 어떠한 영향을 미치는지에 대해 평가해 보았다. 선형흡인효율(Linear capture efficiency) 방법을 이용하여 푸쉬-풀 환기시스템에서 가상의 개방조에서 발생한 오염물질이 푸쉬-풀 시스템에 의하여 포집되지 못하고 누출되는 구역이 어딘지를 찾아낼 수 있었다. 전산유체역학 컴퓨터시뮬레이션은 AIRPAK2.1 (FLUENT CODE) 소프트웨어를 사용하였다. 푸쉬-풀 후드시스템에 방해기류가 강하게 작용하면 상대적으로 강한 와류가 발생하는데, 일반적인 난류모델인 ${\kappa}-{\varepsilon}$모델은 와류현상을 충분히 보여주지 못한 반면에 RNG 모델을 사용했을 때 실험결과를 적절히 모사해낼 수 있었다. RNG 모델을 이용하여 세가지 방향, 즉 푸쉬에서 풀 방향으로, 풀에서 푸쉬 방향으로 그리고 그에 수직되는 방향으로 방해기류가 있을 때의 푸쉬-풀 환기시스템의 흡인효율을 분석하였다. 방해기류가 0.25m/s이하일 때에는 흡인효율이 거의 떨어지지 않았으나, 방해기류가 0.6m/s에서 흡인효율이 40-70%로 떨어짐을 알 수 있었다. 따라서, 방해기류를 감소시킬 수 있는 방안에 대해서도 연구를 해야 되겠지만, 방해기류 존재 하에서 충분한 흡인 효율을 유지할 수 있는 푸쉬-풀 후드 설계기준에 대한 연구도 필요할 것으로 판단된다.

Interference and Re-Inflow of Contaminated Air in Successive Tunnel (연속터널에서의 오염물질 재유입 및 환기영향평가)

  • Kim, Young-Geun;Kim, Woo-Sung;Wye, Yong-Gon;Kim, Nam-Yung;Lee, Ho-Suk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.2
    • /
    • pp.115-134
    • /
    • 2003
  • Recently, there are many cases in the roadway design for successive tunnel with small distance between two tunnels. In this case, the degree of interference for successive tunnels is a significant consideration in the design of ventilation systems. Also, Re-inflows of contaminated air in successive tunnel make serious ventilation problems in case of fire accident in the tunnel. In this study, for successive tunnels in Donghae highway project, the concentration of contaminant such as CO, NOx and Smoke were calculated by numerical analysis using 1D and 3D-CFD analysis. And, the rate of re-inflow at the portals of successive tunnel according to the direction of wind were analysed.

  • PDF

Optical Switching Architectures using WDM for High-Speed ATM Networks (고속 ATM망을 위한 파장 분할 광교환기 구조)

  • So, W.H.;Lee, C.H.;Kim, Y.S.;Kim, Y.C.
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.8
    • /
    • pp.12-20
    • /
    • 1998
  • All-optical networks(AON) are emerging as the next generation broadband networks for wide-area and local-area networks. Many optical switch architectures are currently proposed to realize AON. Specially, optical switches using WDM have a lot of advantages in point of the optical transparency and network topology for B-ISDN services in AON. In this paper, two kinds of Knockout Optical Switching Architectures(KOSA) are proposed for high speed optical ATM networks. We use WDM technologies for them to operate in all-optical area and they are called Architecture-Ⅰ, Architecture-Ⅱ respectively. Each one represents different characteristics according to the number of components and the kind of components, which make KOSA have different performance and system complextity. In order to verify and to compare the performance, these architectures were analyzed and simulated in terms of cell loss ratio, system complexity and buffering speed.

  • PDF