• Title/Summary/Keyword: 환기 시뮬레이션

Search Result 175, Processing Time 0.024 seconds

Ductile Simulation Analysis at Heat Exchanger (열교환기에서의 연성 시뮬레이션 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.50-54
    • /
    • 2008
  • This study is analyzed by the simulation of heat exchanger. As heat conduction happens as contact begins, the temperature increases until $70^{\circ}C$ at the contact part. The displacement increases until 33mm at its maximum and maximum equivalent stress at final stage increases 20 times as much as that of first contact. The expenses about maintenance, repair and management of parts can be reduced largely by applying the simulation about various parts of heat exchanger.

  • PDF

A study on the performance enhancement for combined cycle using cold heat of LNG (LNG 냉열을 이용한 복합사이클 발전시스템의 성능개선연구)

  • 김용희;김병일
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.10b
    • /
    • pp.77-80
    • /
    • 1996
  • 우리나라에서 피크부하용으로 사용하는 복합발전이 하계시에서 외기온도가 상승함에 따라 실제로는 정격출력을 내지 못하고 있다. 따라서 본 연구에서는 연료(LNG)의 냉열을 이용하여 가스터빈의 연소용공기를 냉각시킬 경우, 복합발전 시스템의 성능변화를 분석하기 위하여 시뮬레이션을 수행하였다. 그 결과 LNG의 냉열을 이용하여 연소용공기를 원하는 온도까지 냉각시킬 수 있음을 확인할 수 있었다. 또한 연소기로 연료를 투입하기전에 설계온도까지 예열시키는 열교환기를 통해 배기가스에 함유된 현열을 더욱 많이 회수하면서, 가스터빈 투입연료의 온도를 상승시킬 수 있어, 시스템효율이 더욱 상승함을 알 수 있었다. 결론적으로 외기온도가 변하는 경우에, 본 시스템의 도입을 위해서는 경제성분석과 더불어 열교환기 시스템의 최적합성이 추후 진행되어야 할 것이며, 이를 통해 최적의 발전시스템을 구성할 수 있으리라 생각된다.

  • PDF

A Numerical Study on Effective Smoke-Control System of a Rescue Station in a Tunnel Fire (터널내 열차 화재시 효과적인 구난역 제연 설비를 위한 수치 해석 연구)

  • Yang, Sung-Jin;Won, Chan-Shik;Hur, Nahm-Keon;Cha, Chul-Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.575-578
    • /
    • 2006
  • In designing smoke-control system of rescue station in train tunnel, a purpose is to prevent a disaster by proposing the jet fan operation together with smoke-control curtain in tunnel fire. This study has investigated the relationship of the Heat Release Rate(HRR) and a adequate ventilation velocity to control the fire propagation in tunnel fire, and has improved the effect of the smoke-control curtain on preventing the flow of pollutants. In this study, Computational Fluid Dynamics(CFD) simulations with ST AR-CD(ver 3.24) were carried out on predicting the fire spreading and the flow of pollutants, considering jet fan operations and effect of smoke-control curtain. Our simulation domain is the full scale model of the 'DAEGWALLYEONG' 1st tunnel. The results represent that ventilation operation can control the fire spreading and pollutants effectively to prevent a disaster.

  • PDF

Development of High Precision DC Power supply on MLCC Measurement (MLCC 시험용 고 정밀 DC 전원 장치 개발)

  • Kim, Min-Jae;Choi, Won-Shik;Choe, Yun-Geol;Jeong, Il-Woo;Park, Ki-Hyeon;Park, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1014-1015
    • /
    • 2015
  • 본 논문은 MLCC (Multi-Layer Ceramic Capacitor) 시험용 전원 장치의 설계에 대해 기술 하였다. 개발된 전원 장치의 정격 출력 전압과 전류는 600V / 2A이며 경부하에서 중부하까지 200mV이하의 고 정밀도를 가진다. 전원 장치의 토플로지는 2-스위치 플라이백 컨버터를 인터리브시켜 고 전력/고 시스템 주파수가 가능하도록 구성했다. 출력 필터와 시스템 제어기를 설계하여 전압 리플과 노이즈를 감쇠시키고 시스템 안정도를 높였다. 특히 16bit AD변환기를 이용하여 제어 변수를 받아, DSP(TI사(社) TMS320F28335)로 정전압(CC) / 정전류(CV) 모드 제어를 보다 정밀하게 하였다. 최종적으로 시뮬레이션과 실험을 통해 고 정밀 전압의 전원 장치 설계의 타당성을 확인 하였다.

  • PDF

A Comparative Study of Computational Fire Models for Fire Safety Analysis of Nuclear Power Plant (원자력 발전소 화재안전해석을 위한 전산화재모델의 비교 연구)

  • Kim, Sung-Chan;Kim, Jung-Yong;Yoon, Jung-Sook;Lee, Eun-Shin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.420-423
    • /
    • 2012
  • 원자력 발전소는 화재 발생 시 대규모 피해를 야기하는 특수한 시설물로서 일반 건축물에 비하여 매우 엄격한 화재 안전 기준을 적용하고 있으며 일반 건축물과 차별화된 화재안전 설계 조건을 요구한다. 본 연구에서는 원자력 발전소의 화재안전성을 평가하기 위한 기초연구로써 원자력 발전소 내 주 제어실(이하 MCR)에 대해 화재시나리오 및 환기조건에 따른 화재해석모델의 계산결과를 비교분석하여 각 해석모델의 특성을 파악하고자 한다. MCR 내 화재안전성을 평가하기 위해 Field Model인 FDS 와 Zone Model인 CFAST를 이용하였으며 NUREG/RC-6850, NUREG/RC-1894에 기초하여 화재시뮬레이션을 수행하였다. 해석결과로써 연기농도, 가시거리, 연층높이 등의 데이터를 분석하여 MCR내의 거주가능 시간을 평가하였으며 이를 통해 원자력 시설물의 안전성 확보를 위한 정량적인 자료를 제공하고자 한다.

  • PDF

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

A Study of Performance of Roll-plate type fin-tube Heat Exchanger for the Refrigerator (냉장고용 롤-플레이트형 휜-관 열교환기의 성능에 관한 연구)

  • Ahn, Sung-Jun;Kim, Jong-Su;Kwon, Oh-Boong;Park, Yong-Jong;Ha, Young-Ju;Choi, Sang-Jo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2292-2297
    • /
    • 2008
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new type condenser which will cost less and will be as efficient as the spiral type. The new type condenser consists of a steel tube, steel plates and louver fins attached to the tube. The tube and the plate are bent into a single-passage serpentine shape.

  • PDF

Study on Two-Phase Loop Thermosyphon Heat Exchanger (루프형 2상 유동 열사이폰 열교환기에 관한 연구)

  • 이기우;박기호;이석호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.9
    • /
    • pp.717-724
    • /
    • 2002
  • A heat exchanger (100,000 W) using two-phase loop thermosyphons (TLT) was developed as a waste heat recovery system. An experimental and simulation study was carried out on the heat transfer characteristics of TLT heat exchanger, and the results from the experiments were used to see the possibility which the TLT heat exchanger could be an alternate solution for waste heat recovery system. The experimental results showed the provisional results as a waste heat recovery system. Also computer simulation code can predict the TLT system about the effects of various variables for the operation. Computer simulation results based on the thermal resistance networks were compared with the experimental results. The study clearly shows that the computer simulation for the TLT heat exchanger can Predict the most cases of the affecting parameters involved, provided that correct empirical correlations are used.

A Study on the Analysis of Parametric Transformer (파라메트릭 변압기의 동작해석에 관한 연구)

  • 정기화;박한웅;우정인
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.37-45
    • /
    • 1993
  • A parametric transformer, as static power converter operating on the principle of parametric excitation, is analysed. For the purpose of quantitative analysis of device, the mathematical model of the device is derived. On the basis of this model, the performances of the parametric transformer, such as over and under voltage protection, overload protection, bilateral filtering and frequency multiplication, are obtained quantitatively and analysed qualitatively.

  • PDF