• Title/Summary/Keyword: 환기회로

Search Result 174, Processing Time 0.024 seconds

Evaluation of Changes in Radon Levels in Educational Research Facilities by Number of Ventilation and Time (환기횟수 및 환기시간에 따른 교육연구시설 라돈 수치변화 평가)

  • Shin, Yoon-Seok;An, Jae-Seung;Kim, Seong-Bin;Park, Min-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.335-336
    • /
    • 2023
  • 최근 환경에 대한 관심이 지속적으로 증가함에 따라 실내 공기질에 대한 관심 역시 증폭되었다. 이에 따라 실내 공기질을 결정 짓고 흡연에 이어 폐암 사망률이 높은 라돈에 대한 관심 역시 증가하였다. 따라서 본 연구에서는 실내 라돈가스의 농도를 낮추기 위한 방법을 찾기 위해 RADON EYE RD200을 이용하여 교육연구시설에서의 세 강의동을 대상으로 라돈 방출량을 측정하고, 환기를 통해 라돈의 감소량을 측정한다. 세 강의동 모두 현재 기준치인 148 Bq/m3을 초과하는 수치를 기록하였고, 강의실을 10분간 환기한 결과 1회 환기 시 평균 77 Bq/m3만큼 감소하였고, 2회 환기 시 평균 56 Bq/m3만큼 감소하였다. 본 연구를 통해 라돈의 실태 및 위험성을 인지하고 라돈에 관련된 시설물 지침 및 환기를 강조하는 방안에 대한 마련이 필요하다고 판단된다.

  • PDF

사용후핵연료 중간저장 시설의 사고시 피복관의 산화 거동 연구

  • 유길성;김건식;민덕기;노성기;김은가
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.721-726
    • /
    • 1995
  • 사용후핵연료 중간저장 시설의 누수사고시 예상되는 SFLFL 컴퓨터 코드 분석 결과에 따른 실제 피복관의 산화시험 결과 저장용기 밑바닥 세가지 구멍은 크긴 조건들에 대히 환기회수가 시간당 0회인 경우는 사고후 48시간 경과시 매우 심각한 산화가 예상되며, 나머지 조건의 경우에는 48시간 산화 후 최대 산화량이 90mg/dm$^2$으로 시설의 누수사고시 산화막에 의한 영향은 거의 무시 할 수 있는 것으로 나타난다. 9가지의 시험조건중 안전성은 구멍의 크기가 7.62cm, 환기수가 시간당 2회인 경우가 가장 놓으며. 두번째는 구멍의 크기가 5.08cm, 시간당 환기수 2회의 경우였다. 같은 환기회수의 경우 구멍의 크기가 5.08과 7.62cm인 경우는 비슷하게 나타나지만 2.54와 5.08cm의 경우는 큰 차이를 보인다. 여기에서 수행된 시험은 미조사, 미전처리 시편을 사용한 것이므로 실제로 조사 및 로내 산화막이 입혀진 시편에 대한 추후 시험이 요구된다.

  • PDF

Study on the effective ventilation system in high-level waste disposal tunnel (고준위폐기물 처분터널 내 효율적인 환기시스템에 관한 고찰)

  • Yoon, Chan-Hoon;Choi, Young-Chul;Kim, Jin-Seop
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.363-364
    • /
    • 2014
  • 국내 에너지의 장기적인 수요상황을 볼 때 원자력 발전의 비중이 확대되는 것은 불가피 하므로 환경 친화적인 사용 후 핵연료의 관리 및 고준위 폐기물의 처분방안의 마련은 원자력의 개발만큼이나 중요하다. 이에 본 연구에서는 방사성 폐기물의 효율적인 관리와 저장 및 열제거를 위하여 최적 환기시스템을 적용한 처분장 설계를 목적으로 여러 환기시스템 설계안을 비교 분석하였다. 분석결과, 8가지 중 case 4(병렬회로)와 case 6(혼합 Diagonal 회로)의 환기효율이 우수한 결과를 나타냈으며, 이와 같은 연구를 통해 환경 친화적인 처분장의 건설이 가능할 것이다.

  • PDF

Analysis on the Ventilation Performance of Single-span Tomato Greenhouse with Roof Windows (천창을 설치한 토마토 재배 단동 온실의 환기성능 분석)

  • Nam, Sang-Woon;Kim, Young-Shik;Both, Arend-Jan
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.78-82
    • /
    • 2011
  • Ventilation rates, inside and outside weather data were measured in a arch-shape single-span plastic greenhouse growing tomatoes. On the roof of the experimental greenhouse, round windows which have a diameter of 0.6 m were installed at intervals of 8m. It showed that the number of air changes in this greenhouse were average 0.17 volumes per minute and in the range of 0.02 to 0.32 volumes per minute. These air changes are insufficient to meet the recommended ventilation rate for commercial greenhouses, and it is estimated that interval of 6 m is appropriate for spring or fall season. For summer season, it is necessary to narrow the space or to enlarge the open area of roof windows. Using the heat balance model, the evapotranspiration coefficients of greenhouse tomatoes were estimated from experimental ventilation data, overall heat transfer and solar radiation. It showed that the evapotranspiration coefficients were average 0.62 and in the 0.39 to 0.85 range. We suggest applying 0.6 as the evapotranspiration coefficient in design of ventilation for the single-span tomato greenhouses.

An evaluation of ventilation characteristics of dwelling unit by ventilation network (환기회로망을 이용한 주호의 환기특성 평가)

  • Kim, Sin-Do;Kang, Young;Lee, Ju-Sang
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.81-82
    • /
    • 1999
  • 풍압력 외의 외부에너지가 필요치 않아 에너지를 절약할 수 있고, 외기를 도입하여 실내를 쾌적하게 유지할 수 있다는 장점으로 인해 자연환기에 대한 관심이 높아지고 있다. 자연환기에 영향을 미치는 인자는 건물의 특성, 외기의 특성 등으로 매우 다양하며, 독립적으로 작용하지 않고 상호연관적으로 작용한다.(중략)

  • PDF

The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse (자연환기 온실의 환기회수에 따른 포그냉방시스템의 냉방효과)

  • 김문기;김기성;권혁진
    • Journal of Bio-Environment Control
    • /
    • v.10 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The cooling effect of a fog cooling system has a close relationship to air flow and relative humidity in the greenhouse. From the VETH chart for cooling design, a cooling efficiency can be improved by means of increasing the air exchange rate and the amount of sprayed water. In the no shading experimental greenhouse by time control, when average air exchange rate was 0.77 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature of the greenhouse was 31$^{\circ}C$ that was almost close to outside temperature and cooling efficiency was 82%. When average air exchange rate was close to temperature of the greenhouse that was no cooling and 70% shading greenhouse environment. When average air exchange rate was 2.59times.min$^{-1}$ , spray water amount was 2,009g and shading rate was 70%, inside relative humidity of the greenhouse was increased was 2,009 g and shading rate was 70%, inside relative humidity of the greenhouse was increased, but temperature was not decreased. When average air exchange rate was 2.33 times.min$^{-1}$ and spray water amount was 2,009g, inside temperature was 31.4 and at that time maximum wind speed at the air inlet of greenhouse was 1.9m.s$^{-1}$ . Since time controller sprayed amount of constant water at a given interval, some of sprayed water remained not to be evaporated, which increased relative humidity and decreased cooling efficiency. Because the shading screen prevented air flow in the greenhouse, it also caused the evaporation efficiency to be decreased. In order to increase cooling efficiency, it was necessary to study on controling by relative humidity and air circulation in the greenhouse.

  • PDF

Ventilation System Strategy for a Prospective Korean Radioactive Waste Repository (한국형 방사성 폐기물 처분장을 위한 환기시스뎀 전략)

  • Kim Jin;Kwon Sang-Ki
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.135-148
    • /
    • 2005
  • In the stage of conceptual design for the construction and operation of the geologic repository for radioactive wastes, it is important to consider a repository ventilation system which serves the repository working environment, hygiene & safety of the public at large, and will allow safe maintenance like moisture content elimination in repository for the duration of the repositories life, construction/operation/closure, also allowing safe waste transportation and emplacement. This paper describes the possible ventilation system design criteria and requirements for the prospective Korean radioactive waste repositories with emphasis on the underground rock cavity disposal method in the both cases of low & medium-level and high-level wastes. It was found that the most important concept is separate ventilation systems for the construction (development) and waste emplacement (storage) activities. In addition, ventilation network system modeling, natural ventilation, ventilation monitoring systems & real time ventilation simulation, and fire simulation & emergency system in the repository are briefly discussed.

  • PDF

사용후핵연료 중간저장 시설의 사고시 UO$_2$의 산화거동 연구

  • 김건식;유길성;민덕기;김은가;노성기
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.727-732
    • /
    • 1995
  • 사용후핵연료 중간저장 시설의 누수사고시 예상되는 핵연료봉의 온도상승을 SFUEL 컴퓨터 코드 분석결과에 따른 실제 $UO_2$의 산화거동을 실험하였다. 외기 온도 38$^{\circ}C$에서 환기회수가 시간당 0, 1, 2회인 조건에서 저장용기 밑바닥 구멍 크기가 2.54, 5.08, 7.62 cm인 경우의 실험결과 환기회수 0회 바닥구멍 크기 2,54 cm 일 때 약 15시간 후 건전성 상실(0.6% 무게증가)이 일어났으며 환기회수 2회 바닥구멍 크기 7.62 cm 일 때는 약 21시간 이후에 건전성 상실이 일어나 가장 느렸다. 바닥구멍 크기가 증가할수록 공기 순환비의 영향을 크게 받으며, 또 외기 온도가 낮을 수록 공기 순환비의 영향을 크게 받았다.

  • PDF

Evaluation of Ventilation Performance of a Residential Unit for Different Sampling Points through Actual Field Tests (실증실험을 통한 측정 위치에 따른 주거공간 환기성능 평가)

  • Kwag, Byung Chang;Lee, Soo Man;Kim, Gil Tae;Kim, Jong Yeob
    • Land and Housing Review
    • /
    • v.13 no.3
    • /
    • pp.93-106
    • /
    • 2022
  • Ventilation plays an important role in controlling indoor air quality. Due to the recent spread of infectious diseases such as COVID-19 and with people spending more time indoors, there's been increased attention on the importance of ventilation performance. In many countries, ventilation is regulated by airflow rates and the number of air changes per hour (ACH). However, airflow rates and ACH alone do not provide an accurate account of actual indoor pollutant removal and ventilation uniformity in a space. This study looked into the ventilation performance of an actual residential unit using several sampling points instead of basing it off of airflow and air change rates. Literature review was used to derive relevant influencing factors and the tracer gas dilution method was used for the field test. The study measured air velocity, age of air, and ventilation efficiency at several locations and compared them to the average value at the center of the test space to determine the differences in ventilation performance at the selected measurement points. The study showed that different sampling locations resulted in different ventilation values. Findings of this study will be used to develop an experimental procedure for evaluating indoor ventilation performance of actual residential spaces.