• Title/Summary/Keyword: 환기창 형태

Search Result 8, Processing Time 0.03 seconds

Field Survey and Analysis of Natural Ventilation Characteristics of Multi-span Greenhouse with Different Roof Vent (연동형 비닐하우스의 환기창 형태 조사 및 자연환기 효과 분석)

  • Park, Min jung;Choi, Duck kyu;Son, Jin kwan;Yoon, Sung-Wook;Kim, Hee tae;Lee, Seung-Kee;Kang, Dong hyeon
    • Journal of Bio-Environment Control
    • /
    • v.29 no.1
    • /
    • pp.36-42
    • /
    • 2020
  • The objectives of this study were to investigate the standard and roof vent type of multi-span greenhouse and to analyze the characteristics of natural ventilation of multi-span greenhouse with different roof vent using computational fluid dynamics (CFD) code. The vent area proportion of surveyed farms averaged 10%, it was analyzed that the vent design for natural ventilation is insufficient. The results of natural ventilation efficiency of multi-span greenhouse according to roof vent type showed that the temperature of the position in which the crops grew was the lowest in the conical roof vent type and the highest in the half conical roof vent type. For the natural ventilation effect, the conical roof vent type was the best one, but the structural stability should be evaluated in light of wind load.

A Numerical Study on the Effect of the Shape of Windows on the Ventilation Performance in the Storage Hall of Tripitaka Koreana at Haein Temple (해인사 장경판전 환기창 형태에 따른 환기 성능에 대한 수치해석 연구)

  • Hur, Nahm-Keon;Lee, Myung-Sung;Yang, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.119-123
    • /
    • 2007
  • Ventilation performance in the storage hall of Janggyeongpan Jeon has maintained for more than 600 years. Janggyeongpan Jeon in Haein temple has window structure of bi-level ventilating opening which consists of upper and lower window. Also, different size and shape of windows are adopted for various locations of the hall. In the present study, to analyze effect of shape of windows on ventilation performance in the storage hall, various design alternatives were considered. Numerical analysis of ventilation in the storage hall was investigated under the same simulation condition except for the shape of windows. Through the comparison of numerical results for various window designs, it was evaluated that the current windows shape gives best ventilation performance.

  • PDF

전북대학교 플라즈마 풍동용 0.4 MW 분절형 아크 플라즈마 발생 장치 구축

  • Lee, Mi-Yeon;Seo, Jun-Ho;Kim, Jeong-Su;Choe, Chae-Hong;Kim, Min-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.539-539
    • /
    • 2012
  • 전북대학교 고온플라즈마 응용연구센터는 교육과학기술부 기초연구사업 중 고가연구장비 구축사업의 일환으로, 고 엔탈피, 초음속 유동 환경을 모사하여, 항공우주, 군사기기, 핵융합 분야 등의 고온 재료 개발을 위한 기초 연구 장치로써, 0.4MW급 플라즈마 풍동 장치를 구축하고 있다. 0.4MW 플라즈마 풍동 장치의 플라즈마 발생부는 DC 전원 공급장치와 디스크 형태의 양극과 음극 사이에 동일 형태의 간극을 삽입한 0.4MW급 분절형 아크 플라즈마 토치로 구성되었으며, 토치에서 발생된 아크 플라즈마는 노즐을 통과하며 마하 2~4의 초음속을 나타내도록 설계 제작되었다. 시험 챔버는 노즐에서 나온 초음속 플라즈마의 특성 및 재료 시험을 위한 3차원 이송식 기판이 장착되어 있으며, 고 엔탈피 유동을 관측하기 위한 광학창을 구비하였다. 시험 챔버 하류에는 유동 안정을 위한 디퓨저(diffuser)가 설치되어 있으며, 디퓨저(diffuser)로부터 배출되는 고온가스는 열교환기를 통해 냉각된 후 진공펌프를 통해 대기로 배출되게 된다. 장치의 압력조절을 위하여 $1,000m^3/min$의 용량의 진공펌프 시스템이 설치될 예정이며 가스공급장치, 냉각수 공급장치, 디퓨져, 열교환기는 1MW급 용량으로 설계 제작되었다. 본 장치는 400kW의 전원 공급, 15 g/s의 공기유량 주입 시 약 13 MJ/kg의 고엔탈피를 가진, mach 2~4의 초음속 유동을 나타내는 것을 특징으로 한다.

  • PDF

Development of the wooden window design implementing D.I.Y. modular system (D.I.Y. Modular 방식을 도입한 목재 창 디자인 개발)

  • Kim, Jin-Young;Kim, Do-Yeon;Roh, Yang-Mi;Park, Hyo-Mi
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.401-404
    • /
    • 2004
  • The proposal defines a Do It Yourself system that radically changes the traditional concept of window. it is based on a D.I.Y. system that allows the users to fully customize its windows according to his needs, combining a wood frame with different elements. At the same time, it is preserving the basic function of light and ventilation and defining a new aesthetic code. Despite the restriction of size and shape, the user can choose among many different elements to increase the space efficiency he needs and to give a more enjoyable perspective to the window both in and out door. Also, All the elements are standard and they can be mass-produced according to specific market needs. Therefore, the window of the future will not be just a thin membrane in between the inside and the outside, but it will also play an important "identification role. According to each individual pick, these new windows will help to give identify to anonymous metropolitan areas and to the people living within them.

  • PDF

Efficiency of Different Roof Vent Designs on Natural Ventilation of Single-Span Plastic Greenhouse (플라스틱 단동온실의 천창 종류에 따른 자연환기 효과)

  • Rasheed, Adnan;Lee, Jong Won;Kim, Hyeon Tae;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.225-233
    • /
    • 2019
  • In the summer season, natural ventilation is commonly used to reduce the inside air temperature of greenhouse when it rises above the optimal level. The greenhouse shape, vent design, and position play a critical role in the effectiveness of natural ventilation. In this study, computational fluid dynamics (CFD) was employed to investigate the effect of different roof vent designs along with side vents on the buoyancy-driven natural ventilation. The boussinesq hypothesis was used to simulate the buoyancy effect to the whole computational domain. RNG K-epsilon turbulence model was utilized, and a discrete originates (DO) radiation model was used with solar ray tracing to simulate the effect of solar radiation. The CFD model was validated using the experimentally obtained greenhouse internal temperature, and the experimental and computed results agreed well. Furthermore, this model was adopted to compare the internal greenhouse air temperature and ventilation rate for seven different roof vent designs. The results revealed that the inside-to-outside air temperature differences of the greenhouse varied from 3.2 to $9.6^{\circ}C$ depending on the different studied roof vent types. Moreover, the ventilation rate was within the range from 0.33 to $0.49min^{-1}$. Our findings show that the conical type roof ventilation has minimum inside-to-outside air temperature difference of $3.2^{\circ}C$ and a maximum ventilation rate of $0.49min^{-1}$.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture (NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구)

  • Kim, Ji-Young;Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • This research aims todevelopa compression/absorption hybrid heat pump system using an $NH_3/H_2O$ as working fluid.The heatpump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a desorber, a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above $90^{\circ}C$ using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangementof the plate heat exchangers with regard tothe concentration and distribution at the inlet of the absorber.

Effect of Stocking Density on Chicken Meat Grades and PSE Incidence in Broiler House with or without Window (유창 및 무창계사의 사육 밀도에 따른 닭고기 등급 및 PSE육 출현에 미치는 영향)

  • Chae, H.S.;Kang, H.S.;Yoo, Y.M.;Jang, A.;Jeong, S.G.;Ham, J.S.;Ahn, C.N.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • This study was performed to evaluate the effect of the level of stocking density of housing with or without window on chicken meat quality. The incidence of $1^+$ grade of whole chicken housed with window significantly influenced by stocking density. The incidence of $1^+$ grade chicken at high stocking density ($0.050\;m^2$/head), standard stocking density ($0.066\;m^2$/head), and low stocking density ($0.083\;m^2$/head) was 26, 52, and 66%, respectively. Breast muscle of chicken housed with window and with low stocking density showed higher incidence of $1^+$ grade than high stocking density. Also minor and severe PSE (pale, soft, extractive) incidence of chicken meat were showed 4% each, while the $1^+$ grade chicken was not appeared at low density. In chicken thigh, the incidence rate was not affected by stocking density. In chicken housed without window, the incidence of $1^+$ grade chicken in high, standard, and low stocking density was 18, 8, and 46%, respectively. Also, the incidence of $1^+$ grade chicken breast was 2.6 times higher than the chicken in low stocking density. However, incidence of $1^+$ grade thigh was not affected by the stocking density. These results suggest that high stocking density significantly reduced the incidence of $1^+$ grade chicken meat regardless of housing with or without window.