• Title/Summary/Keyword: 환기창

Search Result 52, Processing Time 0.023 seconds

Mo Interpretation for the Substituent Effect of Stilbenes (스틸벤의 치환기 효과에 대한 분자궤도함수론적 해석)

  • Lim Sung-Mi;Park Byung-Kak;Lee Gab-Yong
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.1
    • /
    • pp.38-43
    • /
    • 1992
  • The Hammett's substituent constants were interpreted for substituted stilbenes by HMO method. The appropriate quantum chemical indices are chosen as independent contribution of the inductive and the resonance effects for substituent constants. It has been found that theoretical values, ${\sigma}_p{^{th}}$, defined as sum of the net charge, self atom polarizability and difference in HOMO energy between substituted- and unsubstituted-stilbenes, correlated with experimental Hammett's substituent constants. The dipole moments were found to be correlated with differences in ${\sigma}_p{^{th}}$ between two substituents for disubstituted stilbenes. It has been also found that transition optical spectra, ${\lambda}_{max}$ of the substituted stilbenes depend on difference between the HOMO and the LUMO energy as expected.

  • PDF

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF

The Influence of Pretreatment Period, 2-Hydroxynicotinic Acid and Anther Co-pretreatment on Embryo Induction in Isolated Microspore Culture of Capsicum annuum L. (고추의 나출 소포자 배양시 전처리 기간, 2-Hydroxynicotinic Acid 및 약-공동전처리가 소포자배 발생에 미치는 영향)

  • Park Eun-Joon;Kim Jin-Ae;Lee Jong-Suk;Jang In-Chang;Yoon Michung;Chung Sang-Ho;Kim Moonza
    • Journal of Plant Biotechnology
    • /
    • v.32 no.1
    • /
    • pp.37-44
    • /
    • 2005
  • Microspores were isolated from pepper (Capsicum annuum L.) anthers by using a micro-blender and cultured in modified NLN medium at $25^{\circ}C$. The influence of pretreatment period at $32^{\circ}C$, adding the 2-hydroxynicotinic acid to a pretreatment medium, and co-pretreatment anthers with microscopes on the induction of embryo were examined. Globular and torpedo embryos were observed from 3 weeks after culture. Embryo development was not synchronized within culture. After 4 weeks in culture, in addition to globular and torpedo embryos, cotyledonary embryos were observed. Normal cotylodonary embryos developed into plantlets when transferred to a solid hormone free B5 medium containing $2\%$ sucrose. Embryo yields were significantly higher after 1- and 2-day pretreatment at $32^{\circ}C$. However the development of embryo ceased at the globular or heart stage. In contrast, embryo yields were lower after 3- to 6-day pretreatment at $32^{\circ}C$ and embryo developed at the cotyledonary stage. After adding the 2-hydroxynicotinic acid to anther pretreatment solution, embryo yields were slightly increased. However most embryos occurred were at the globular or heart stage. Co-pretreatment of microspores with anthers was deleterious for embryo induction and development. AS far as we know, this is the first report of success in obtaining high frequency of embryogenesis and plantlets formation from isolated microspores of pepper. Although the culture conditions have to be optimized further, this promising microspore culture system can be used for genetic transformation, selection for dominant and recessive traits as well as for the production of homozygous doubled haploid plants.

Method for Preventing Asphyxiation Accidents by a CO2 Extinguishing System on a Ship (선박 내 CO2 소화설비에 의한 질식사고 방지 기법)

  • Ha, Yeon-Chul;Seo, Jung-Kwan;Hwang, Jun-Ho;Im, Kichang;Ryu, Sang-Hoon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.57-64
    • /
    • 2015
  • Carbon dioxide extinguishing systems are broadly used for onshore and offshore fire accidents because of excellent performance and low cost. However, there is risk with carbon dioxide systems, which have caused many injuries and deaths by suffocation associated with industrial and marine fire protection applications. In this study, a numerical analysis was performed to predict the fire suppression characteristics of a carbon dioxide system in the compressor room of ships. A double protection safety system is suggested to prevent suffocation accidents from carbon dioxide extinguishing systems. Four scenarios were selected to study the variation of the heat release rate, maximum temperature, a $CO_2$ and $O_2$ mole fraction, and fire suppression characteristics with the carbon dioxide system. The importance of proper design is suggested for a ventilation system in the compressor room of ships.

The Effect of Vantilation System Renovation from Winch Style to Non-window Style for Swine Barn (개방돈사의 무창돈사형 환기시설 개선 효과)

  • Song, J.I.;Jean, J.H.;Park, H.K.;Kang, H.S.;Choi, D.Y.;Kim, D.H.;Park, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • In South Korea, mora than 90% of swine barns had open-style side wall by winch operation, and less than 5% of swine barns were semi-windowless or windowless style. The aisle ventilation system of the barn was changed to roof-wall ventilation system, and the width and the length of barns were 10~12 m and 30~50 m, respectively. The width of aisle satisfying energy save was 2~3 m. The re-modeled barns inhaled air through duct which was opened to aisle and exhaled through forced ventilation fans on the windowless wall which was accomplished by installing planks on the open wall. After remodelling, the culling ratio and energy cost were decreased from 11% (47 heads) to 3% (12 heads) and from 1,550,000 won to 730,000 won, respectively. Hence, re-modeled swine barns raising 400 heads could save 2,835,680 won during winter (from December to March).

Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation (히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.797-802
    • /
    • 2012
  • In this study, the potential performance enhancement in a dual heat pump system through series operation was investigated by a comparison between the performance for parallel and series operation for a heating supply temperature of $60^{\circ}C$. To compare the performance of each configuration fairly, the heat transfer surface area of the heat exchangers was fixed. The inlet temperatures and the flow rates of the heat source and the load were also fixed. In addition, the heat transfer and pressure drop characteristics of the working fluids were considered to achieve a more realistic comparison. The results show that the heating coefficient of performance (COP) of the series configuration is approximately 5% higher than that of the parallel configuration under the simulation conditions considered in the present study.

A comparative analysis of the total window thermal transmittance simulation result according to the evaluation method of effective conductivity(λeff) of frame cavity - Focused on unventilated frame cavity simulation results of single window - (창틀 공기층의 유효 열전도율(λeff) 산정방법 차이가 창 전체 열관류율(Uw) 시뮬레이션 결과에 미치는 영향에 대한 비교 분석 - 단창 창틀의 비환기 공기층에 대한 시뮬레이션을 중심으로 -)

  • Lee, Yong-jun;Oh, Eun-joo;Kim, Sa-kyum;Choi, Gyeong-seok;Kang, Jae-sik
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.79-85
    • /
    • 2016
  • Purpose: It is difficult to calculate frame U-value because of the two reason. First is selection of air properties in cavity. Second is calculation method in window frame. For this reason, it is important to decide cavity properties in window frame. However, international standards offered different method(ISO 15099, ISO 10077) and air properties was changed according to the two methods. The aim of this study was to suggest method for deriving accurate frame U-value using international standard methods and CFD simulation. Method: First, this study conducted analysis calculation method of ISO 15099 and ISO 10077. And, CFD simulation conducted based on same condition. Finally, ISO calculation and CFD simulation results were verified through comparison with real experiment results. Result: The results show that effective conductivity of ISO 15099 was the highest value. ISO 10077 and CFD result followed. The convergent values of ISO 10077 was the highest. ISO 15099 and CFD followed. ISO calculation reflecting CFD simulation results will reduce error with experimental results.

Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture (NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구)

  • Kim, Ji-Young;Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Ra, Ho-Sang;Kim, Yong-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.229-235
    • /
    • 2011
  • This research aims todevelopa compression/absorption hybrid heat pump system using an $NH_3/H_2O$ as working fluid.The heatpump cycle is based on a combination of compression and absorption cycles. The cycle consists of two-stage compressors, absorbers, a desorber, a desuperheater, solution heat exchangers, a solution pump, a rectifier, and a liquid/vapor separator. The compression/absorption hybrid heat pump was designed to produce hot water above $90^{\circ}C$ using high-temperature glide during a two-phase heat transfer. Distinct characteristics of the nonlinear temperature profile should be considered to maximize the performance of the absorber. In this study, the performance of the absorber was investigated depending on the capacity, shape, and arrangementof the plate heat exchangers with regard tothe concentration and distribution at the inlet of the absorber.

A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(III) -양지붕형 하우스의 창 개방방법에 따른 온.습도의 변화-)

  • 김진현;김철수;구건효;이기명
    • Journal of Biosystems Engineering
    • /
    • v.20 no.2
    • /
    • pp.162-172
    • /
    • 1995
  • The ventilation in greenhouse have been important for such as adjustment of temperature, supplying of the oxygen, prevention of the overhumidity, density adjustment of $CO_2$, discharge of harmfulness gas, etc. However, the general ventilation which had been used the quantitative control method in discharge of a property of air mechanism in greenhouse, and caused mainly in waste of the heating energy and growth obstacle of the vegetable. Therefore, this study was peformed to obtain more scientific ventilation method using by analysis and measurement of the isothermal lines according to opening of window ventilation in greenhouse, and the results are summarized as follows. 1. The ventilating amount was more influenced by rather opening amount of window than the ventilating time. 2. In window ventilation, the temperature in greenhouse was mostly changed within 5 minutes after ventilating not regard to the spot of opening, after about 10 minutes temperature became to equilibrium state under the respective ventilating conditions. 3. In opening of the skylight only, isothermal lines were complicated, therefore, a tall vegetable may be possible to damage by a cold-weather from the lower central port in greenhouse. 4. Isothermal lines were a tendency to simply in opening of a side window that may be more effective ventilation in kinds of the short vegetable. 5. In conditions of internal temperature>setting temperature>external temperature, a skylight can be suitable to open 10~20cm in order to the optimum ventilation in greenhouse. 6. In conditions of internal temperature>external temperature>setting temperature, opening of all the windows or both the side windows that can be suitable in order to obtain the optimum ventilation in greenhouse. 7. An effect of ventilation was the most excellent to open of all the windows or both the side windows, and it were also found orderly excellent to open of the side window and the skylight or the skylight only, to open of the side window only. 8. Temperature was varied as the equation of T=Tc+ (To-Tc)e-at, and the ranges of (a) values were limited within 0.34~0.68. 9. A variations of humidity were similar to that of temperature, s.

  • PDF

An Analysis of the Application Technology of Heat Recovery System from Dyeing Wastewater (염색폐수 열회시스템 적용기술 분석)

  • 장기창;박성룡;이상남;라호상;박준택;함성원;박영태
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-205
    • /
    • 2001
  • A great deal of energy is necessary with emission of lots of wastewater in dyeing and finishing process, but heat recovery from wastewater is not introduced since is technology is not developed yet. In order to obtain the method utilizing hot water produced by heat source, that is, dyeing wastewater it was investigated the characteristics of dyeing and finishing process and energy basic unit. Energy basic unit of polyester/cotton (T/C), polyester/rayon (T/R) and polyester dyeing process are higher than that of the other process. The average quantity of wastewater for each dyeing company is 20,470 ton/month, the average temperature of wastewater is about 41$^{\circ}C$. Because the SS solution of wastewater in polyester dyeing process is lower than that of the other process, the effect of corrosion in heat recovery system is low. Since the energy price for 1000 kcal produced by vapor compression heat pump is presumed to be 22.50 won, it is found to be very economic heat recovery system, and its payback is 2.09 years for the factory with LNG boiler.

  • PDF