Radiation Absorbed Dose Measurement after I-131 Metaiodobenzylguanidine Treatment in a patient with Pheochromycytoma (갈색세포종 환자에서 Medical Internal Radiation Dose법을 이용한 I-131 Metaiodobenzylguanidine 치료 후 흡수선량 평가)

  • Yang, Weon-Il;Kim, Byeung-Il;Lee, Jae-Sung;Lee, Jung-Rim;Choi, Chang-Woon;Lim, Sang-Moo;Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.422-429
    • /
    • 1999
  • Purpose: The measurement of radiation absorbed dose is useful to predict the response after I-131 labeled metaiodobenzylguanidine (MIBG) therapy and determine therapy dose in patients with unresectable or malignant pheochromocytoma. We estimated the absorbed dose in tumor tissue after high dose I-131 MIBG in a patient with pheochromocytoma using a gamma camera and Medical Internal Radiation Dose (MIRD) formula. Materials and Methods: A 64-year old female patient with pheochromocytoma who had multiple metastases of mediastinum, right kidney and periaortic lymph nodes, received 74 GBq (200 mCi) of I-131 MIBG. We obtained anterior and posterior images at 0.5, 16, 24, 64 and 145 hours after treatment. Two standard sources of 37 and 74 MBq of I-131 were imaged simultaneously. Cummulated I-131 MIBG uptake in tumor tissue was calculated after the correction of background activity, attenuation, system sensitivity and count loss at a high count rate. Results: The calculated absorbed radiation dose was 32-63 Gy/ 74 GBq, which was lower than the known dose for tumor remission (150-200 Gy). follow-up studies at 1 month showed minimally reduced tumor size on computed tomography, and mildly reduced I-131 MIBG uptake. Conclusion: We estimated radiation absorbed dose after therapeutic I-131 MIBG using a gamma camera and MIRD formula, which can be peformed in a clinical nuclear medicine laboratory. Our results suggest that the measurement of radiation absorbed dose in I-131 MIBG therapy is feasible as a routine clinical practice that can guide further treatment plan. The accuracy of dose measurement and correlation with clinical outcome should be evaluated further.

  • PDF

A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET (N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구)

  • Kim, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Ju, Hee-Kyung;Kim, Yong-Jin;Kim, Byung-Tae;Choi, Yong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.73-82
    • /
    • 1997
  • Regional myocardial blood flow (rMBF) can be noninvasively quantified using N-13 ammonia and dynamic positron emission tomography (PET). The quantitative accuracy of the rMBF values, however, is affected by the distortion of myocardial PET images caused by finite PET image resolution and cardiac motion. Although different methods have been developed to correct the distortion typically classified as partial volume effect and spillover, the methods are too complex to employ in a routine clinical environment. We have developed a refined method incorporating a geometric model of the volume representation of a region-of-interest (ROI) into the two-compartment N-13 ammonia model. In the refined model, partial volume effect and spillover are conveniently corrected by an additional parameter in the mathematical model. To examine the accuracy of this approach, studies were performed in 9 coronary artery disease patients. Dynamic transaxial images (16 frames) were acquired with a GE $Advance^{TM}$ PET scanner simultaneous with intravenous injection of 20 mCi N-13 ammonia. rMBF was examined at rest and during pharmacologically (dipyridamole) induced coronary hyperemia. Three sectorial myocardium (septum, anterior wall and lateral wall) and blood pool time-activity curves were generated using dynamic images from manually drawn ROIs. The accuracy of rMBF values estimated by the refined method was examined by comparing to the values estimated using the conventional two-compartment model without partial volume effect correction rMBF values obtained by the refined method linearly correlated with rMBF values obtained by the conventional method (108 myocardial segments, correlation coefficient (r)=0.88). Additionally, underestimated rMBF values by the conventional method due to partial volume effect were corrected by theoretically predicted amount in the refined method (slope(m)=1.57). Spillover fraction estimated by the two methods agreed well (r=1.00, m=0.98). In conclusion, accurate rMBF values can be efficiently quantified by the refined method incorporating myocardium geometric information into the two-compartment model using N-13 ammonia and PET.

  • PDF