• Title/Summary/Keyword: 환경측정기

Search Result 235, Processing Time 0.03 seconds

Development of the External Instrumentation System of a Fighter Aircraft for Flight Test (비행시험을 위한 전투기 외장형 계측시스템 개발)

  • Yeom, Hyeong-Seop;Oh, Jong-Hoon;Sung, Duck-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.9
    • /
    • pp.907-913
    • /
    • 2010
  • In this paper, we have described a development of the external instrumentation system of a fighter aircraft for flight test. The external instrumentation system consists of the instrumentation pod and the image pod. The instrumentation pod measures a flight data(attitude, velocity, altitude, etc) of the fighter aircraft by using GPS/AHRS sensor. The image pod takes high-speed images for the separation trajectory of a smart bomb with 2 high-speed cameras and video signal for it with one general camera. We have verified the performance of the external instrumentation system through the ground test, the environment test and the flight test.

플라즈마 처리에 의한 아라미드 섬유의 표면개질 연구

  • Park, Seong-Min;Kim, Ji-Yeon;Kim, Sang-Uk;Kim, Myeong-Sun;Gwon, Il-Jun
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.100-100
    • /
    • 2011
  • 아라미드 섬유는 고강도, 고내열성 등의 성능이 매우 우수하여 생산량이 제일 많은 수퍼 섬유이면서도 강직한 분자구조와 고결정성의 치밀한 구조 때문에 염색이나 기능성 가공이 어려워 의류 인테리어용, 타 산업으로의 다양한 전개가 어려운 실정이다. 최근에 사용이 급증되고 있는 아라미드 섬유를 상업적으로 염색 및 가공을 할 수 있는 공정 프로세스를 개발하여 표면 개질, 견뢰도의 향상 및 기능성 가공, 아라미드 및 관련 타 소재와의 교직을 통하여 기존제품의 성능개선 등의 기술 확보를 통해 선진국 및 대만 중국 등의 경쟁국 위주로 전개되고 있는 아라미드 염색가공기술을 조기에 확보하여 선진기술에 대응하여 우리나라의 섬유산업 인프라를 활용한 다양한 용도전개를 위해서 본 기술이 시급히 전개되어야 한다. 이에 본 연구에서는 환경친화적 건식처리 공정인 플라즈마 처리를 통해 아라미드 섬유의 표면개질 효과를 알아보았다. 플라즈마 처리에 의한 아라미드 섬유의 모폴로지 변화는 주사전자현미경(FE-SEM)으로 확인하였으며, 표면 개질 효과는 적외선분광기(FT-IR)과 접촉각 측정기로 평가하였다. 플라즈마 처리 가스나 출력이 증가함에 따라 아라미드 섬유 표면의 경시변화를 확인하였으며, 젖음성이 향상되는 것을 확인하였다.

  • PDF

Performance Analysis of UWB System using S-Function Builder (S-Function Builder를 이용한 UWB 시스템의 성능해석)

  • Lee Sung-Sin;Byon Kun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.516-521
    • /
    • 2005
  • The application of UWB not only complies with the requirements of remote sensors system(ECG), it also contributes to the effectiveness of the implementations through its unique qualities such as ultra low transmission power - an important factor when dealing with biomedical equipment. In this paper, the aim is to replace the wired ECG sensors with a wireless link and design wireless UWB communication system. The various pulse shapes are presented that satisfies the FCC spectral mask and FCC part 15 rule. It is shown that UWB can be a high rate transmission over short ranges using Rake receiver, with the capability for reliably transmitting 100Mbps over distance at about 10 meters.

Program Implementation for Efficient Calibration Management of Measuring Instruments (효율적 계측기기 교정검사 관리를 위한 프로그램 구현)

  • Roh, Su-Sung;Lee, Chil-Gee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.05a
    • /
    • pp.727-730
    • /
    • 2005
  • 계측기기의 사용업체들은 기기 관리부분 및 교정검사 주기가 상이한 계측기기 교정검사 관리부분의 어려움으로 인하여 교정검사 유효기간을 지나치는 경우가 많았으며, 국가교정검사 기관은 각 계측기기의 측정 데이터 결과 형식이 달라 교정검사 후 발행하는 성적서의 작성 및 발행 하는데 어려움이 많았다. 또한 계측기기 사용업체와 교정검사기관 모두 관리 프로그램과 교정검사 성적서 관리 프로그램을 별도로 사용하였다. 이러한 계측기기 및 성적서 관리를 하나의 시스템으로 쉽게 통합관리 할 수 있도록 구성 하였으며, 각각의 상이한 계측기기 주기 정보를 데이터베이스화 하여 주기별, 측정기기별, 업체별 검색 및 자동 팝업창으로 상태를 알려주게 하였고, 계측기기별 상이한 형식의 측정 데이터는 부서별, 유형별로 데이터베이스화 하여 응용프로그램과 연동될 수 있도록 구현 하였다. 계측기기 관리 및 교정검사 관리 부문에 있어서 사용 대상에 따라 GUI 환경으로 구현된 프로그램으로서 기본설정을 통하여 교정대상업체 및 교정검사기관 모두 하나의 통합된 프로그램으로 사용 및 관리를 할 수 있다.

  • PDF

Development of an Integrated Measurement and Analysis System for DTV Field Test (DTV 필드테스트를 위한 통합 측정 및 분석 시스템 개발)

  • Kim Young-Min;Suh Young-Woo;Kwon Tae-Hoon;Mok Ha-kyun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.253-257
    • /
    • 2004
  • 디지털 TV 방송이 본격적으로 보급됨에 따라 2004 년 후반부터 각 방송사들은 디지털 방송네트워크의 설계를 위해 본격적인 전계강도 실측을 실시하고 있다. DTV 신호 측정에는, 가장 기준이 되는 전계강도 측정기를 비롯하여 DTV 복조기(demodulator), 각종 셋톱박스, 위성항법장치(GPS)를 이용한 지형정보시스템(GIS) 등 많은 장비가 필요하고 측정항목도 다양하여, 한 지역을 측정하는데 많은 시간이 소요될 뿐 아니라 측정자의 숙련도에 따라 측정결과의 정확도와 신뢰도가 떨어질 수 있다. 본 논문에서는 이러한 문제들을 해결하기 위해 다양한 계측장비와 운용장비의 제어를 체계적으로 관리하고 측정절차를 일반화하며 측정결과 데이터를 데이터베이스화하여 측정결과를 용이하게 파악할 수 있는 통합 측정 시스템을 제안한다. 또한, 본 시스템은 측정 뿐 아니라 지형정보시스템과 전계강도 예측시스템을 도입하여 측정지점 주변의 수신환경 분석 및 최적 수신위치의 검색정보 등을 제공하며, 다량의 측정결과에 대한 다양한 분석이 가능하여 커버리지 분석 및 송신 네트워크의 설계 등에 활용될 수 있다.

  • PDF

A Comparison Study of Aerosol Samplers for PM10 Mass Concentration Measurement (PM10 질량농도 측정을 위한 시료채취기의 비교 연구)

  • Park, Ju-Myon;Koo, Ja-Kon;Jeong, Tae-Young;Kwon, Dong-Myung;Yoo, Jong-Ik;Seo, Yong-Chil
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • A PM10 (aerodynamic diameter${\leq}$10 ${\mu}m$) sampler is used to quantify the potential human exposure to suspended particulate matter (PM) and to comply with the governmental regulation. This study was conducted to compare and evaluate the same PM10 cutpoint and different slopes between United States Environmental Protection Agency (USEPA) PM10 sampling criterion and American Conference of Governmental Industrial Hygienists/$Comit\acute{e}$ $Europ\acute{e}en$ de Normalization/International Organization for Standardization thoracic PM10 sampling criterion through theory and experiment. Four PM10 samplers according to the USEPA criterion and one RespiCon sampler in accordance with the thoracic PM10 criterion were used in the present study. In addition, one DustTrak monitor was used to measure real time PM10 mass concentrations. All six aerosol samplers were tested in a PM generation chamber using polydisperse fly ash. Theoretical mass concentrations were calculated by applying the measured particle size distribution characteristics (geometric mean = 6.6 ${\mu}m$, geometric standard deviation = 1.9) of fly ash to each sampling criterion. The measured mass concentrations through a chamber experiment were consistent with theoretical mass concentrations in that a RespiCon sampler with the thoracic PM10 criterion collected less PM than a PM10 sampler with the USEPA criterion. The overall chamber experiment results indicated, when a PM10 sampler was used as a reference sampler, that (1) a RespiCon sampler had a normalizing factor of 1.6, meaning that this sampler underestimated an average 60% of PM10 mass sampled from a PM10 sampler, and (2) a DustTrak real-time monitor using a PM10 inlet had a calibration factor of 2.1.

The Study of noise and vibration on application of the method breaking & excavating rock(Super wedge) (암파쇄굴착공법(Super wedge) 적용에 따른 소음.진동에 대한 고찰)

  • Won, Yeon-Ho;Kang, Choo-Won;Ryu, Chang-Ha
    • Proceedings of the KSEE Conference
    • /
    • 2006.10a
    • /
    • pp.167-184
    • /
    • 2006
  • There is cattle shed and house structure of a country village in the vicinity of the construction site. that is why the environmental effect evaluation on blasting had been done in advance to prevent any harm to those from the work. As the result, it is impossible to apply to the blasting method, and the Super wedge method, a kind of a rock-splitting method which there is no secondary breaking by a breaker of the methods breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation, applied to decrease noise and vibration, and to the work classification, the extent of noise and vibration measured with the instrument only for noise(SC-310c) and with the instrument only for vibration(BLASTMATE) respectively. A drilling, splitting, collecting, loading works at the closest point(about 10m) is barely possible on the consideration of vibration to the result of measurement, but carefulness needs on moving of equipment. On the case of noise, even drilling, collecting, loading work except splitting at the comparatively close point(about 20m) is difficult. So, the method breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation has to apply in consideration of noise level in accordance with the work processing.

  • PDF

Development of Verification Method for ADCP (ADCP 유량 측정기기의 검정 방안 개발)

  • Noel Kang;Chi Young Kim;Kyung Min Kang;Yo Han Cho;Chang-Hwan Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.305-305
    • /
    • 2023
  • 수문조사기기 검정은 강수량, 수위, 유량 등과 같은 수문자료를 관측하는 수문조사기기가 대상지역의 수문상황을 정확하게 관측하는지를 검사하는 일련의 과정으로 「수자원의 조사 계획 및 관리에 관한 법률」 제12조에 법적 기반을 두고 있다. 검정 대상은 강수량, 수위, 유속, 유사량, 토양수분량, 증발산량, 증발량 측정기기 총 7종이며, 환경부장관으로부터 한강홍수통제소가 검정업무를 위임받고, 한국건설기술연구원과 한국수자원조사기술원이 위탁받아 운영중에 있다. 최근에는 증발산량, 토양수분량 및 유량 측정기기기 등이 첨단화되어 기존 검정 방식에 대한보완 및 신설에 대한 요구가 증가하고 있다. 특히, 유량 측정시 기존에 사용하였던 회전식 유속계는 ADCP(Acoustic Doppler Current Profiler) 유량측정기기로 대체되어 활용률이 2013년 24%에서2021년 67%로 약 2.8배 급격히 증가하였다. 하지만 수문조사기기 검정 관련 고시 내 ADCP에 대한검사방법 및 허용오차 등의 규정이 부재하여 수문조사기기의 검정 공백이 발생하는 등의 문제가 존재하고 있다. 이에 본 연구에서는 ADCP 운영 및 기술 현황, 현행 법령, 국외 사례 등을 검토하여 ADCP 유량측정기기의 검사방법 및 허용오차에 대한 방안을 제시하고자 한다. ADCP 검사방법은 총 5단계로 외관검사, 자가진단 검사, 온도센서 검사, 수심측정 검사, 유량비교측정 검사에 따라 검정을 실시한다. 첫 번째 외관검사시에는 기기 외관과 센서 등 물리적 손상을 점검하고, 두 번째 자가진단 검사에서는 센서 변환 매트릭스 값, 수신부 센서 테스트, RAM/ROM 테스트, 통신 테스트 등에 관한 정상값 산출 여부를 확인한다. 세 번째 온도센서 검사에서는 검증용 온도센서를 이용한 값과 ADCP에 부착된 온도센서 값과 차이를 확인하고 ±2℃초과시 재검사 또는 적절한 조치를 취한 후 다음 단계의 검사를 진행한다. 네 번째 수심측정 검사에서는 수조 내 수심 측정을 확인하여 실제 수심과의 오차를 확인하고 ±1% 초과시 재검사 또는 적절한 조치 후 다음 검사를 실시한다. 유량비교 측정검사에서는 각 기기 간의 평균유량의 상대오차를 평가하는 것으로 ±5%미만에는 합격, ±5이상 ±10%미만에서는 재검사, ±10%이상에서는 공장수리를 권고하도록 하고, 1~5 단계의 검사를 통과한 기기를 대상으로 인증서를 발급하도록 한다. 유량비교 측정검사시에는 매년 ADCP를 사용하는 일반기업 및 공공기관 등이 모여 ADCP의 성능을 상호간 비교하는 'ADCP 기술협력 워크숍'을 확장하여 실시할 수 있다. 각 검사 단계의 허용오차는 USGS 또는 제조사 기준과 2022년 ADCP 기술협력 워크숍 성능검사 분석 결과를 토대로 하였다. 본 ADCP 검정 방안은 향후 ADCP 모델별로 단계별 시범 검토를 통해 세부사항에 대한 제시가 필요하며, 온도센서 검사, 수심측정 검사, 유량 비교측정검사에 대한 허용오차에 대한 타당성에대한 검증 및 검토가 이루어져야 할 것으로 사료된다.

  • PDF

Development of Electro-Biosensor for the Residual Pesticides using Organic Carbon and Cobalt Phthalocyanine (Cobalt Phthalocyanine 탄소유기 전극을 이용한 농약 잔류량 측정 센서개발)

  • Yu, Young-Hun;Cho, Hyung-Jun;Park, Won-Pyo;Hyun, Hae-Nam
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.72-76
    • /
    • 2010
  • We have developed the bio-electrode measuring the variance of the amount of acetylcholine affected by residual pesticide. The working electrode of the biosensor was made by combination of cobalt phthalocyanine and carbon organic compounds. The biosensors were constructed by screen-printing method. The principle of working electrode is similar to thiocholine sensor. We have fabricated the biosensor using standard screen printing method. Generally, the biosensor made by printing method formed thick film biosensor. When the electrodes were made by electrochemical cells, the generation of current by the addition of enzyme substrate was inhibited by standard solutions of organo-phosphate pesticides. The detection limit of sensor is about 0.5 $\mu{g}/L$ for carbofuran. We could improve the responsibility of the sensor by controlling the cobalt phthalocyanine and thiocholine concentration ratio. Also we have tested the EPN and Chlorpyrifos pesticides and found that the biosensor is applicable to fast determination of residual pesticides.

Reduction Effect of CO2 Discharge of Green PC (그린 PC의 탄소(CO2) 배출량 감축효과)

  • Kim, Young-Geil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.2
    • /
    • pp.115-121
    • /
    • 2014
  • Since the rapid development of information age and information technology might be considered to cause environmental problems, Green IT is perceived as core technology for low carbon green growth and the minimum waste of electricity. In this vein, Green IT is becoming new paradigm of focusing on natural environment. This study examines current various IT required for green growth, and studies various methods for diminution of carbon discharge in Korea and other countries. Especially, it focuses on the diminution effect of carbon discharge by using Green PC, and compares the difference of voltage, voltaic current, and the use of electricity between Normal PC and Green PC by using HPM-300A, and measures carbon discharge of Normal PC and Green PC. The result shows that the diminution effect of $CO_2$ discharge of Green PC is amount to 11.5Kg per year, and the effect of green growth is up to the conservation of 2 or 3 pine trees.