• Title/Summary/Keyword: 확산초음파

Search Result 68, Processing Time 0.031 seconds

Effects of Moisture Content in Concrete on Diffuse Ultrasound (확산초음파의 콘크리트 함수율에 대한 의존성)

  • Ahn, Eunjong;Shin, Myoungsu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.142-147
    • /
    • 2020
  • This study investigates the effects of moisture content on diffuse ultrasound to be applied for the evaluation of micro-structural damage in concrete subjected to various environmental conditions. We monitored diffuse wave parameters for concrete samples in process of water saturation for 5 days. Dried samples were immersed in a water bath, and the change of moisture content in concrete were estimated by measuring the change of mass. For the diffuse wave analysis, a frequency range of 500 kHz, which represents a scattering regime of ultrasound in concrete, was selected. The test results reveal that the ultrasonic diffusivity slightly changed, and the ultrasonic dissipation significantly increased by approximately 120% in the process of water saturation. Therefore, the moisture content in concrete should be considered for the evaluation of micro-structural damage using diffuse wave techniques.

액체/초임계 이산화탄소의 QCM을 이용한 초음파 세척 효과 연구

  • 박광헌;고문성;윤청현;김홍두;김학원
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.2-2
    • /
    • 2002
  • Quartz Crystal Microbalance(QCM)은 표면에 묻은 물질의 미량의 무게변화도 간단히 측정 할 수 있어 반웅기 내에서 일어나는 현상올 in-situ로 즉시 알 수 있는 장점을 가진 장치이 다. 이 장치를 이용하면 초엄계 이산화탄소 내에서 용해도를 알 수 있고, 대상물질이 녹아냐 가는 속도를 측정하면 확산계수를 구할 수 있다. 그리고, 초음파 혼을 반응용기 내에 설치하 고, 초음파 효과를 알아보았다. 먼저 static system에서 초음파 효과를 알아보았다. Cu(acac)2를 대상으로, 밀폐된 용기에서 수행한 실험에서, 액체와 초임계 이산화탄소 내에서 용해속도를 QCM으로 구할 수 있었다. 용해속도로부터 Cu(acac)2의 확산계수를 측정할 수 있었다. 액체 내에선 $10^{-4}{\;}cm2/sec$, 초임계상태에서 $10^{-2}{\;}cm2/sec$의 값을 갖는 것으로 나타 났다. 그리고, 초음파를 사용할 경우 이 확산계수값이 4-5배정도 증가하는 것으로 냐타났다. 이어서 dynamic system에서 반응을 알아보았다. Cyanex를 함유한 C02를 반응용기에 흘리 면서 QCM표면에 묻은 Co이온의 용해속도를 측정하였다. 초음파는 용해도에 아무 역활을 안하는 것으로 나타났다. 주어진 조건에서 13 microgram/gram-cyanex의 용해도를 갖는 것 으로 나타났다.

  • PDF

Bubble Growth Analysis in Ultrasonic Foaming using Reaction Injection Molding (반응사출 성형을 이용한 초음파 발포시 기포성장해석)

  • 김찬중
    • The Korean Journal of Rheology
    • /
    • v.7 no.3
    • /
    • pp.237-249
    • /
    • 1995
  • 폴리우레탄 미세포 포움의 가공에 대한 연구를 수행하였으며 기체 과포화 수지 내 의 핵생성율을 증진시키기 위하여 폴리올과 이소시아네이트의 혼합물에 초음파 가진을 적용 하였다. 미세포 구조는 고압에서 질소 가스로 폴리올을 과포화ㅣ키고 폴리우레탄의 두 성분 을 충돌혼합시킨 직후 초음파에 의해 기포를 생성시켜 이루어진다. 낮은 포화 압력에서 질 소에 의해 포화된수지의 핵생성율을 증가시키기위하여 초음파 가진을 적용하였다. 확산에 의해 기포의 성장이 조절된다고 가정하고 금형이 충전되는 동안에 금형 내부에서의 기포성 장기구를 이해하기 위하여 수치적인 방법으로 이론적 연구를 수행하였다. 경화 시간과 확산 경계를 고려하여 최종적인 기포의 크기를 계산하였으며 반응속도론을 고려하여 중합반응 동 안의 폴리우레탄의 점도의 변화를 예측하고 경화 시간을 결정하였다. 이론적 및 실험적으로 결정된 기포의 수를 기준으로 하여 확산 경계를 예측하였다.

  • PDF

Connectivity Enhancement of Broken Structural Regions in Ultrasound Images (초음파 영상에서 끊어진 구조 영역 연결성 향상 방법)

  • Seo, Hyun-Gi;Song, Hye-Jeong;Kim, Baek-Sop
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.10
    • /
    • pp.751-759
    • /
    • 2010
  • This paper is to propose a method to enhance the connectivity of the broken structures. The pixels to be connected are found by a decision rule which is based on the intensity and gradient information of the neighboring pixels. The intensity of the pixel, if it is decided to be filled, is increased so that the pixel together with its neighbors looks connected. The anisotropic diffusion follows to make the connected structural region look more natural. The same structure matrices have been used both to get gradient information and to decide the direction of diffusion to improve the computational speed. It has been shown by the experiments on the real ultrasound images that the broken structural regions can be connected by the proposed method.

Field Study of Water Quality Improvement by Circulation, Sonication and Ozonation (수류확산과 초음파와 오존을 이용한 현장 수질 개선 평가)

  • Tekile, Andinet;Kim, Ilho;Lee, Jai-Yeop
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.170-180
    • /
    • 2017
  • The study used jet water flow, ultra-sonication and ozonation system units to investigate impact of the unit components on water quality of stagnant Yeo-cheon River reach, Korea. Samples were collected at six locations, before operation and after 1, 3 and 6 hrs of operation. By operating the water flow unit only, dissolved oxygen increased as high as 90% after 3 hr at 25 m downstream of the device and Chl-a was reduced by 80%. Incorporating sonication, greater than 80% of Chl-a was removed even at 100 m distance from the device. Besides, total dissolved phosphorus was reduced from an average value of $420({\pm}70){\mu}g/L$ before ultrasonic irradiation to $160({\pm}40){\mu}g/L$ after the treatment. Releasing ozone into the flow with sonication, Chl-a was considerably removed from the water column and ammonia nitrogen was also decreased to average value of $20{\mu}g/L$ from $60{\mu}g/L$. However, as only $3{\ast}10^{-3}mg/L$ of ozone was used for safety purpose and due to brief reaction time it takes, effect of integrating ozone to the system covered limited area. Generally, combining sonication to jet flow is promising in preventing algal bloom formation since it has effectively removed Chl-a from the water column.

Parametric Imaging with Respiratory Motion Correction for Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 호흡에 의한 흔들림을 보정한 파라미터 영상 생성 기법)

  • Kim, Ho-Joon;Cho, Yun-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • In this paper, we introduce a method to visualize the contrast diffusion patterns and the dynamic vascular patterns in a contrast-enhanced ultrasound image sequence. We present an imaging technique to visualize parameters such as contrast arrival time, peak intensity time, and contrast decay time in contrast-enhanced ultrasound data. The contrast flow pattern and its velocity are important for characterizing focal liver lesions. We propose a method for representing the contrast diffusion patterns as an image. In the methods, respiratory motion may degrade the accuracy of the parametric images. Therefore, we present a respiratory motion tracking technique that uses dynamic weights and a momentum factor with respect to the respiration cycle. Through the experiment using 72 CEUS data sets, we show that the proposed method makes it possible to overcome the limitation of analysis by the naked eye and improves the reliability of the parametric images by compensating for respiratory motion in contrast-enhanced ultrasonography.

A Parametric Imaging Technique for Characterizing Focal Liver Lesions in Contrast-Enhanced Ultrasound (간 병변 분석을 위한 조영증강 초음파 데이터의 영상화기법)

  • Park, So-Jeong;Sung, Myung-Chul;Lee, Seung-Kang;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.369-372
    • /
    • 2012
  • 조영증강 의료 초음파 영상에서 조영제의 확산효과에 대한 분석은 간질환과 연관된 각종 병변을 검출하고 분석하는 과정에서 매우 유용한 정보를 제공한다. 본 연구에서는 초음파 영상에서 조영제의 확산 패턴을 분석하고 이를 영상화하는 방법을 제안한다. 이 과정에서 부수적으로 호흡에 의한 흔들림 현상을 보정하고 노이즈의 영향을 극복할 수 있는 방법론을 고찰한다. 호흡주기에 따른 모멘텀 요소를 고려한 ROI 추적 기법은 측정과정에서의 흔들림과 노이즈에 의한 오류를 최소화 할 수 있게 한다. 조영제의 확산 단계에 따라 서로 다른 노이즈 비율을 고려하여 동적 가중치를 할당하는 방법으로써 흔들림을 보정하였으며, 조영제의 전이 시간과 패턴을 분석하고 그 특성을 분류함으로써 간 병변 분석을 위한 효과적인 영상화기법을 구현하였다. 또한 생성된 영상에서 노이즈를 제거하고 영상을 개선하는 방법으로서 MRF 기반의 최적화 알고리즘을 적용하는 영상 개선 기법을 제시한다.

Processing of Polyurhane Microcellular Foam for Thermal Insulation (단열재용 폴리우레탄 미세포 포움의 가공)

  • 윤재륜
    • The Korean Journal of Rheology
    • /
    • v.9 no.4
    • /
    • pp.190-199
    • /
    • 1997
  • 단열용도의 폴리우레탄 미세포 포움의 가공에 대한 연구를 수행하였다. 미세포 구조 를 얻기 위해서는 핵생성율을 증진시키고 균일한 분포의 기포를 생성시켜야 한다. 이를 위 해 이산화탄소 기체를 풀리올과 이소시아네이트에 각각 과포화시키고 충돌혼합하여 초음파 가진을 적용하였다. 이산화탄소 기체가 수지 내부에서 기포 내부로 확산함에 따라 기포의 성장이 조절된다고 가정하고 금형이 충전되는 동안에 금형 내부에서의 기포성장기구를 이해 하기 위하여 수치적인 방법으로 이론적 연구를 수행하였다. 경화 시간과 확산 경계를 고려 하여 최종적인 기포의 크기를 계산하였으며 반응속도론을 고려하여 중합반응동안의 폴리우 레탄의 점도의 변화를 예측하고 경화 시간을 결정하였다. 실험적으로 결정된 기체 분자수를 기준으로 하여 이론적으로 확산경계를 예측하였다. 화학적 발포제인 물과 함께 물리적 발포 제인 이산화탄소를 각각 1,2,3기압의 포화압력으로 변화시키면서 폴리올과 이소시아네이트에 포화시켜 폴리우레탄 포움을 제작하고 제작된 포움의 밀도, 열전도도, 및 기포의 수와 지름 을 측정하였다. 측정된 결과로부터 이산화탄소의 포화압력과 초음파 가진이 포움의 기포핵 생성에 미치는 영향을 살펴보았다.

  • PDF

Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence (조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.297-300
    • /
    • 2015
  • In medical ultrasonography, transit time and contrast enhancement patterns are considered as important parameters to analyze liver diseases. In many recent researches, time-intensity curves(TIC) have been used for calculating the transit time of the contrast agents. However, the intensity curve may include the variations which are caused by the micro-bubble effect of contrast agents. In this paper, we propose a complementary approach to diagnostic parameter extraction which utilizes a density information as well as the intensity data. The proposed technique improves the accuracy in extraction of the transit time and velocity of contrast agents for detection and characterization of focal liver lesions. Through the experiments using a set of clinical data, we show that the proposed methods can improve the reliability of the parametric image data.

Ultrasonic Backscattering Profiles from Zirconium Plate with Beryllium Diffusion Layer (베릴륨 표면확산 층을 가진 지르코늄 판재에서의 후방산란 프로파일)

  • Hwang, Y.H.;Choi, H.O.;Park, C.H.;Lee, Y.H.;Kwon, S.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.4
    • /
    • pp.342-348
    • /
    • 2003
  • Ultrasonic backscattering profiles of the Zr plates(with a thickness of 1.32mm) with/without Be-Zr alloy layer(with a thickness of $100{\mu}m$) were measured at various incidence positions to evaluate the characteristics of Be diffusion layer. Four principal subprofiles were observed in the backward ultrasound radiated from leaky Lamb waves. The angles and the intensities of the subprofile peaks decreased by the stiffening effect of Be layer. Generation and change of the subprofiles were explained by the acoustical property, collective group velocity and leaky factor difference of the plates under consideration. Backward radiation subprofiles turned out to be an useful method for evaluating thin diffusion layers on plates.