• Title/Summary/Keyword: 화학식

Search Result 87, Processing Time 0.042 seconds

Illite, Reviewed on the Chemical Compositions - The Mixed Phase among Muscovite, Pyrophyllite and Chlorite: EPMA Quantitative Analysis of Shale from the Jigunsan Formation at Seokgaejae in Samchuk-City, Gangwon-do (화학조성으로 다시 보는 일라이트-백운모, 파이로필라이트 및 녹니석의 혼합상: 강원도 삼척시 석개재에 분포하는 직운산층 셰일에 대한 EPMA 정량분석)

  • Choi, Seung-Hyun;Mun, Hyang-Ran;Lee, Young-Boo;Lee, Jung-Hoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.143-153
    • /
    • 2012
  • Mica-type minerals (illites) in the shales of the Jigunsan formation at Seokgaejae in Samchuk-City, Gangwon-do are studied using electron probe micro analysis (EPMA). The average chemical formula of the mica-type mineral obtained from the quantitative analysis is $(K_{1.17}Na_{0.04}Ca_{0.01})(Al_{2.80}Mg_{1.17}Fe_{0.78})(Si_{6.34}Al_{1.66})O_{20}(OH)_4$, which shows a chemical formula within the range of illite. These illites so called can be considered as mixed-phases among muscovite, pyrophyllite and chlorite due to the low contents of interlayer cations and high Mg, Fe. The formula of illite is separated into those three minerals and the method for the separation is newly formulated and proposed in this study. From the formula of illite, the content of muscovite is estimated from K (Na and Ca included), the content of chlorite by Mg+Fe, and the rest remains as pyrophyllite. The chemical formula of muscovite can be calculated by subtracting the compositions of pyrophyllite and chlorite from the analyzed composition of illite using an ideal formula for pyrophyllite and analyzed average formula for chlorite. The calculated formula of muscovite is supposed to be stoichiometric in principle. The result of the separation of analyzed illite is 61% muscovite, 27.3% chlorite and 11.7% pyrophyllite and the calculated formula of muscovite after separation is $(K,Na,Ca)_{2.00}Al_{3.69}(Si_{6.75}Al_{1.25})O_{20}(OH)_4$. The calculated formula of muscovite slightly low in Al content can be considered to be reasonable in general when the low content of Al in the rock and the uncertainties of chlorite compositions used in the calculation are counted. This supports that the method of separation proposed in this study is also applicable.

전기화학식 이산화탄소 센서

  • Park, Jong-Uk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.16.2-16.2
    • /
    • 2011
  • 이산화탄소는 인체에 무해하지만 인간의 신진대사와 깊은 관련이 있기 때문에 인간의 정신적 육체적 행동을 제어하는 분야에 많이 응용되고 있다. 따라서 지능형 빌딩이나 고급 공동주택 등의 실내공기를 제어하는 시스템에 적용되어 효율적으로 환기시스템을 운용하는데 사용되어져 왔다. 앞으로 이는 에너지절감과 연동되어 자동차나 가전제품 등 앞으로 점점 밀폐되어가는 구조에 사용이 늘어날 것으로 전망된다. 그러나 종래는 이산화탄소가 특정파장(4.2 um)의 적외선을 흡수하는 성질을 이용하여 Lambert law에 의해 이산화탄소의 양을 측정하였다. 따라서 가격이나 크기가 비교적 경제적이지 못한 측면이 많았다. 이와 반대로 전기화학적인 방식은 가격이나 크기의 측면에서 장점이 있었으나, 초기동작시간이나 안정성, 수명 등에서 상용화되기에는 아직 소비자가 이해하기 힘든면이 많았다. 이에 고체전해질을 이용하여 수명이나 초기시간 및 안정성을 획기적으로 개선하여 상용화가 가능하도록 만든 이산화탄소 센서를 소개하고자 한다. 이 센서는 전자회로와 결합되어 사용이 편리하도록 모듈화 하였고 이 모듈을 사용하여 "airwatch"라는 응용제품으로 판매되고 있다.

  • PDF

Series Stacking Techniques of Electrochemical Hydrogen Compressors (전기화학식 수소 압축기 직렬 스택 기술)

  • SANG HOON CHO;CHANG JONG KIM;MIN SOO KIM;DONG KYU KIM
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.2
    • /
    • pp.168-174
    • /
    • 2024
  • The electrochemical hydrogen compressor was run under diverse operating conditions in order to probe its capabilities and limitations. It was found that, unlike single-cell operations, the electrochemical hydrogen compressor stack performance improved with a rise in temperature. This improvement in performance was attributed to the gradual weakening of the electro-osmotic drag over time, impacting membrane resistance. As a result of these experiments, compression levels, up to an impressive 120 bar, using the electrochemical hydrogen serial stack were achieved.

XML 기반 과학기술 정보 처리

  • Chae, Jin-Seok
    • Journal of Scientific & Technological Knowledge Infrastructure
    • /
    • s.6
    • /
    • pp.42-57
    • /
    • 2001
  • XML을 사용하여 수학식을 표현하는데 사용되는 MathML에 대해 설명하고, 화학식을 표현하는데 사용되는 CML, 염기서열등의 분자 생물학적 정보를 표현하는데 사용되는 BSML과 BIOML에 대해 설명하고자 한다.

  • PDF

Nickel Oxide Nano-Flake Films Synthesized by Chemical Bath Deposition for Electrochemical Capacitors (CBD(Chemical Bath Deposition) 법으로 제조된 전기화학식 캐패시터용 NiO 나노박편 필름)

  • Kim, Young-Ha;Park, Soo-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.163.2-163.2
    • /
    • 2010
  • In this work, nano-flake shaped nickel oxide (NiO) films were synthesized by chemical bath deposition technique for electrochemical capacitors. The deposition was carried out for 1 and 2 h at room temperature using nickel foam as the substrate and the current collector. The structure and morphology of prepared NiO film were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). And, electrochemical properties were characterized by cyclic voltammetry, galvanostatic charge-discharge, and AC impedence measurement. It was found that the NiO film was constructed by many interconnected NiO nano-flakes which arranged vertically to the substrate, forming a net-like structure with large pores. The open macropores may facilitate the electrolyte penetration and ion migration, resulted in the utilization of nickel oxide due to the increased surface area for electrochemical reactions. Furthermore, it was found that the deposition onto nickel foam as substrate and curent collector led to decrease of the ion transfer resistance so that its specific capacitance of a NiO film had high value than NiO nano flake powder.

  • PDF

Crystal Structure of NASICON by Rietveld Structural Refinement (Rietveld Refinement에 의한 NASICON의 결정구조)

  • Kang, Eun-Tae;Cheong, Hoon;Choi, Jin-Sam;Choi, Jin-Beom
    • Korean Journal of Materials Research
    • /
    • v.6 no.5
    • /
    • pp.504-514
    • /
    • 1996
  • 고상반응법과 sol-gel법으로 제조된 NASICON의 상온과 25$0^{\circ}C$에서의 X선 회절 데이터를 리트벨트 분석을 행하였다. monoclinic에서 rhombohedral로 상전이가 일어나도 원자들의 변위는 매우 작았다. 이들 상간의 ZrO6 팔면체와 Si(P)O4 사면체고 구성된 골격은 다소 다르게 나타남으로 인하여 Na 이온의 자리도 변하였다. 이들 방법으로 제조된 NASICON은 Zr이 부족한 비화학양론 화학식, Na 1+x+4yZr2-xSixP3-xO12으로 표현될 수 있었다. 제조법에 따라 Na 이온들의 자리 점유율이 변화하였다. 상온에서는 Na(1)과 Na(3)자리의 자리 점유율의 합이 거의 1에 가까웠으나, 25$0^{\circ}C$에서는 Na(1)과 mid Na 자리를 단위 화학식 당 한 개를 약간 상회하는 Na 이온이 점유하였다. 상온과 25$0^{\circ}C$에서의 Na 이온의 이동 경로가 다름을 알 수 있었다. 또한 25$0^{\circ}C$에서는 Na(1)자리와 Na(2)자리 사이에 mid Na가 존재하며, 이 자리가 Na 이온의 이동에 중요한 역할을 함을 알 수 있었다.

  • PDF

A study of electrochemical characteristics for high voltage electric charge type hydrocarbon sensor (고전압 하전방식 hydrocarbon 센서의 전기화학적 특성연구)

  • Hong, Ji-Tae;Chon, Young-Kap;Kim, Jeong-Hoon;Seo, Hyun-Woong;Kim, Ho-Sung;Lee, Dong-Gil;Lee, Kyung-Jun;Son, Min-Gyu;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1358-1359
    • /
    • 2008
  • HC(hydrocarbon)센서는 최근 내연기관의 과도상태의 연소 효율 및 배기가스 저감 효율을 높이기 위하여 산소센서와 함께 연소제어 분야에서 많이 사용되고 있다. 현제 HC센서는 전기화학식 및 current limiting 방식을 많이 사용하고 있으며 이는 HC가스의 이온화를 유도하는 촉매를 매질로 하는 전기화학식 센서이다. 이러한 촉매의 경우 장기 사용 시 촉매의 열화 및 변형 등으로 신뢰도가 떨어지게 된다. 본 논문에서는 촉매를 이용하지 않고 HC 가스의 이온화를 위하여 고전압 하전방식의 hydrocarbon센서를 고안하였으며[1], 여러 배출가스를 통한 센서의 전기화학적 성능을 분석하였고 온도 및 HC성분에 따른 전류치 변화를 이용하여 이론적 계산식을 제안하였다.

  • PDF

A Study on Performance and Reactor Behavior of Chemical Refrigerator (화학식 냉동기의 성능 및 반응기 거동에 관한 연구)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-95
    • /
    • 1997
  • A chemical heat pump based on the reversible reactions between metal chlorides and ammonia gas is attractive alternative to compression system and liquid absorption systems in cooling and refrigerating fields. The advantages of chemical heat pump are no regulatory constants due to CFC refrigerants, utilization of gas, industrial waste heat, electricity, fuel oil etc. as heat sources and wide applications to energy storage system, large-scale energy managements for industrial process. The scale-up of chemical heat pump from laboratory prototype to pilot plants necessitates the interpretation of system performance and evaluation of dynamic behavior in the chemical reactor. This study contains the prediction of performance of chemical refrigerator according to operating condition, the dynamic simulations through reactor modelling, which is used for the calculation of reactive medium temperature and the conversion variation with reactor cooling temperature, and the effect survey of block parameters on the power of refrigerator.

  • PDF