• Title/Summary/Keyword: 화학발광법

Search Result 204, Processing Time 0.036 seconds

Determination of Glucose in Whole Blood by Chemiluminescence Method (화학발광법에 의한 전혈 중의 당 정량)

  • Lee, Sang Hak;Choi, Sang Seob
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.3
    • /
    • pp.223-229
    • /
    • 2001
  • A method for the determination of glucose in human whole blood by chemiluminescence method using a stopped flow injection system has been studied. The method is based on the differences in the chemiluminescence intensities of luminol due to the different amounts of hydrogen peroxide produced from the glucose oxidase catalyzed reaction. The enzyme reactor was prepared by immobilization of glucose oxidase on aminopropyl glass beads and the chemiluminescence from a flow cell was measured by means of an optical fiber bundle. In order to obtain the optimum experimental conditions, effects of pH for the chemiluminogenic solution and enzyme reactor, flow rate and temperature on the chemiluminescence intensity were investigated. The calibration curve obtained under optimum experimental conditions was linear over the range from $1.0{\times}10^{-1}$ mM to 7.0 mM and the detection limit was $6.0{\times}10^{-2}$ mM. The proposed method was applied to the determination of glucose in whole human blood sample and the results were compared with those obtained by an official method. The present method was also evaluated by the results of recovery experiments.

  • PDF

Preparation and Luminescent Properties of YNbO$_4$ : Bi Phosphors by Flux Technique with B$_2$O$_3$ (Boron Oxide Flux를 이용한 YNbO$_4$ : Bi 청색 형광체의 제조 및 발광 특성)

  • 한정화;김현정;박희동
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.3
    • /
    • pp.319-324
    • /
    • 1999
  • 기존의 고상 반응법에 의해 합성된 YNbO4 : Bi 형광체의 발광특성을 개선하기 위하여 B2O3 융체 첨가법으로 형광체를 합성하고, 빛발광(PL) 및 저전압 음극선발광(CL)을 측정하였다. PL 및 CL 모두 415~440 nm 영역에서 강한 청색 발광 스펙트럼을 나타냈으며, 고상 반응의 경우와 마찬가지로 Y/Nb 비율이 화학 양론상의 1:1인 경우보다 결함구조를 인위적으로 조절한 51/49나 54/46에서 최대의 발광강도를 보였다. 한편, 고상 반응에서는 125$0^{\circ}C$에서 4시간 열처리하는 것이 최대의 발광효과를 나타냈으나, B2O3융제를 첨가하고 110$0^{\circ}C$에서 열처리한 시료가 결정성이 좋고 입자의 크기 및 형태가 균일하여 PL뿐만 아니라 CL에서도 우수한 발광특성을 보였다. B2O3융제를 첨가하는 방법으로 열처리 온도를 낮추고 입자크기와 형태를 조절하여 형광체의 휘도를 개선할 수 있었다.

  • PDF

나트륨 Flux 혼합첨가에 따른 MgWO4:Tb3+ 형광체의 합성과 발광 특성

  • Gang, Dong-Gyun;Lee, Seong-Jae;Jo, Seon-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.221-221
    • /
    • 2016
  • 최근에 희토류 이온이 도핑된 텅스텐산(tungstates) 형광체에 대한 연구가 재조명되고 있다. 텅스텐산 형광체는 우수한 광학적 특성과 높은 화학적 안정성을 나타내기 때문에 X-선 증강 스크린(X-ray intensifying screens), 광고판용 형광 램프, 발광 다이오드, 레이저, 섬광체(scintillator), 전계방출 디스플레이 영역에 그 응용성을 넓히고 있다. 본 연구는 모체 결정 MgWO4에 희토류 이온인 Tb3+와 융제(flux)의 몰 비를 변화 시켜 고상반응법을 사용하여 합성을 하였다. 합성한 형광체를 여기 파장 281 nm로 제어하였을 시, 545 nm의 녹색 발광 스펙트럼을 관찰 하였다. Tb3+이온이 0.10 mol일 때, 가장 발광 세기가 컸으며, 몰비가 증가 할수록 발광의 세기는 점차 커지다가 0.12 mol에서 작아졌다. 주 발광 신호 이외에도 489 nm, 586 nm, 621 nm에서 상대적으로 작은 발광 스펙트럼을 보였다. XRD를 통해 분석한 결정구조는 단사정계임을 알 수 있었으며 주 피크는 $23.9^{\circ}$에서 발생 하였고 이는 (110)면에서 발생한 회절 신호이다.

  • PDF

Synthesis and Electrochemical Characterization of The New Luminescent Metal-Chelate Complexes (새로운 금속 킬레이트 착물 발광체의 합성과 전기화학적 특성 연구)

  • Park, Jee Young;Choi, Don Soo;Kim, Young Kwan;Ha, Yun Kyoung
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.3
    • /
    • pp.243-248
    • /
    • 2000
  • Oganic electroluminescent devices (OELD) with multilayer structures have been studied actively for the application to a flat-panel display. Netal-chelate complexes hrboxylate. These complexes were characterized by FT-IR, MS/FAB, $^1$H-NMR, UV-vis and photoluminescence (PL). More importantly, the electrochemical gap (Eg), electron affinity(EA) and ionization potential (IP) of these complex films were investigated. Data from cyclic voltammetry(CV) were compared with the bandgap obtained from UV-vis and discussed. Further studies on the EL of these new materials are now in progress.

  • PDF

Determination of Cr(Ⅲ) Iron by Chemiluminescence Method (화학발광법을 이용한 Cr(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Ju, Ik Su
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.2
    • /
    • pp.145-150
    • /
    • 2002
  • A Method to determine Cr(III)ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Cr(III) to a solution of lucigenin a nd hyrogen peroxide. The effects of pH, injection volumes of reagent and sample, and concentration of lucigenin and hyrogen peroxide on the chemiluminescence intensity have been investigated. The calibration curve for Cr(III) ion was linear over the range from 1.0${\times}$$10^{-6}$ to 1.0${\times}$$10^{-3}$M and the detection limit was 5.2${\times}$$10^{-8}$M under the optimal experimental condition of 437nm, 12.8,and 1.0${\times}$$10^{-6}$ and 2.0M for emission wavelength, pH, and concentration of lucigenin and hyrogen peroxide, respectively.

Determination of Fe(II) ion and Fe(III) ion by Chemiluminescence Method (화학발광법을 이용한 Fe(Ⅱ)이온과 Fe(Ⅲ)이온의 정량)

  • Lee, Sang Hak;Nam, Myeong Sik
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.6
    • /
    • pp.509-514
    • /
    • 2002
  • A method to determin Fe(II) and Fe(III) ion in aqueous solution by chemiluminescence method using a stopped flow system has been studied. The method is based on the increased chemiluminescence intensity with the addition of Fe(III) ion to a solution of lucigenin and hydrogen peroxide. The effects of KOH concentration, flow rate of reagents, $H_2O_2$ concentration and citric acid concentration used for the masking of Fe(II) ion on the chemilu-minescence intensity have been investigated. The calibration curve for total Fe was linear over the range from 1.0${\times}$$10^{-6}$ M to 1.0${\times}$$10^{-4}$M, coefficient of correlation was 0.996 and the detection limit was 1.0${\times}$$10^{-7}$M under the optimal exper-imental conditions of 4.0 M, 2.0 M, 3.5 mL/min for the concentration of $H_2O_2,$ KOH and flow rate of reagents, respec-tively. The calibration curve for Fe(Ⅲ) was linear over the range from 1.0${\times}$$10^{-6}$M to 1.0${\times}10^{-4}$ M, the coefficient of correlation was 0.997 and the detection limit was 5.0${\times}$$10^{-7}$M under the optimal experimental conditions.

Study on optical emission spectroscopic method for measuring OH radical distribution in rocket plume (로켓 플룸 내부 OH 라디칼 공간분포 계측을 위한 발광 분광 기법에 관한 연구)

  • Han, Kiwook;Hahn, Jae W.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1135-1139
    • /
    • 2017
  • Spatial distribution of chemical species in flame is a important indicator understanding the flame structure and combustion characteristics, and optical emission spectroscopy has been widely used for the measurement because of its simple and non-intrusive methodology. In this study, we suggest the feasibility of the measurement of chemical species (OH radical) distribution in rocket plume using optical emission spectrometer which was developed for the spatially resolved measurement along the line-of-sight. In order to predict the ground state concentration of species from the measured emission intensity by optical emission spectrometer, we consider thermal and chemical excitation mechanisms in flame, and assume thermodynamic equilibrium for the thermally excited species. We also present the spatial resolution and the correction of collection characteristics of the optical emission spectrometer depending on object distance.

  • PDF

Ca-test에 의한 유기발광소자 봉지용 분자층 증착 Alucone 박막의 투과 방지 특성

  • O, Seung-Sik;Park, Min-U;Park, Geun-Hui;Yeo, Dong-Hyeon;Jeong, Dong-Geun;Park, Jin-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.401-401
    • /
    • 2012
  • 유기발광소자는 유연 소자로의 적용, 자체 발광 등의 장점으로 차세대 디스플레이로서 각광받고 있다. 하지만 유기발광소자는 유기물을 발광층으로 하고 있기 때문에 수분에 취약하다는 단점이 있다. 그래서 봉지 기술(encapsulation)을 필요로 한다. 널리 알려진 방법으로는 유리로 소자를 감싸고 내부에 흡습제를 충진하여 수분 투습을 줄일 수 있다. 하지만 위 기술을 사용할 경우 유기발광소자의 장점인 유연 소자의 적용이 어렵다. 따라서 박막 봉지 기술을 이용하면 보다 얇은 두께의 소자 제작이 가능하고 유연 소자의 적용 역시 가능해진다. 박막 코팅을 이용한 봉지 기술 중 화학적 증착법(Chemical Vapor Deposition, CVD)이나 물리적 증착법(Physical Vapor Deposition, PVD)을 이용하는 방법이 널리 알려져 있지만 원자층 증착법(Atomic Layer Deposition, ALD)을 이용하면 보다 낮은 두께의 치밀한 박막을 제작 할 수 있다. 본 연구는 원자층 증착법을 응용한 분자층 증착법(Molecular Layer Deposition, MLD)을 이용하여 Trimethylaluminum과 Ethylene glycol을 순차적으로 주입함으로써 Alucone 유기 박막을 제작하고 유기발광소자의 봉지 기술로의 적용을 위해 투과 방지막 특성에 관하여 분석했다. 박막 봉지 기술로서 적용하기 위해 제작된 투과 방지막은 원자층 증착법으로 Al2O3무기 박막을 제작하고 분자층 증착법으로 Alucone 박막을 순차적으로 증착하였다. 이를 Ca를 이용하여 전도도를 측정하고, 투습도를 계산하여 투과 방지막 특성을 분석하였다. Alucone 박막은 우수한 투과 방지막 특성을 가지지는 못하지만 적층 구조로 제작함으로써 두 쌍의 Alucone/Al2O3일때, $6.07{\times}10^{-2}g/m^2day$의 투습도를 보여주고 있다. Alucone 박막의 존재는 수분이나 산소의 투과 경로 길이를 늘려줌으로써 Alucone/Al2O3 박막의 투과방지 특성이 향상되는 것으로 사료된다.

  • PDF

Preparation of Standard Phosphatidylcholine Hydroperoxide for Chemiluminescence-HPLC Assay (화학발광고속액체크로마토그래피법에 대한 표준물질인 포스파티딜콜린 하이드로퍼옥사이드의 조제)

  • Song, Jin Hyang;Choi, Hong Yeob;Park, Dong Ki
    • Analytical Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.474-477
    • /
    • 1998
  • A simple and rapid method for preparation of standard phosphatidylcholine hydroperoxide (PCOOH) in chemiluminescence-HPLC assay (CL-HPLC) was developed using the rose bengal dependent spectrofluorometric oxidation. The concentration of obtained PCOOH was determined by FOX (ferrous oxidation-xylenol orange) assay and then subjected to a CL-HPLC system.